Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Ozone Measurements with the US EPA UV-DIAL: Preliminary Results

A compact airborne down-looking lidar system was developed at the Environmental Protection Agency in Las Vegas. This differential absorption lidar (DIAL) was designed to simultaneously measure range-resolved concentrations of ozone (O3) and sulfur dioxide (SO2) in the lower troposphere, together with an indication of the aerosol distribution. The five laser wavelengths (i.e., lambda(sub 1) = 277 nm, lambda(sub 2) = 292 nm, lambda(sub 3) = 313 nm, lambda(sub4) = 319 nm, lambda(sub 5) = 369 nm) were generated via Raman conversion of a focused KrF excimer laser. The system is currently installed in a truck-based mobile laboratory. For the ground testing, an opening in the truck floor together with a folding mirror under the truck makes a horizontal, or upwardly inclined direction of measurement possible. Initial ground testing has been performed in the vicinity of a Desert Research Institute (DRI) ambient air monitoring site, located at Cottonwood Cove approximately 85 km south east of Las Vegas, Nevada. At this site O3 and SO2 concentrations are continuously monitored with an average accuracy better than +/- 10 percent. A temporary ozone measurement station with identical accuracy was set up at a distance to get a second point of comparison for the range-resolved DIAL measurements.

Moosmueller, H.↗

Experimental Characterization and Modeling of High Hole Mobility GeSn Quantum Wells: The Role of Alloy Disorder Scattering

Understanding mechanisms influencing electrical transport in material systems not only provides a scientific explanation for observed behavior but also offers insight into ways to enhance transport in devices. This study reports experimental hole mobility of 8 x 10 4 cm 2 V -1 s -1 in a Ge 0.92 Sn 0.08 , the highest recorded mobility for the GeSn system. A study of the material's quality is presented using structural and electrical characterization techniques, with transport data being supported by simulations using an extensive modeling framework. Quantum Hall measurements further indicate the material's high quality and potential spintronic applications, with extracted values of 0.0689$m$ 0 and 13.6 for the effective mass and effective g‐factor, respectively. It is observed that transport is limited by alloy disorder scattering at cryogenic temperatures. A comparative study between the presented structure and similar quantum well heterostructures revealed that the difference in hole mobilities is captured by a disparity in the reduced nominal alloy disorder scattering potential (Δ U alloy = 0.8 eV), that is lower than the value of a fully random alloy (Δ U alloy = 1.4–1.7 eV) potential. The difference in Δ U alloy suggests that heterostructures with similar geometries and alloy compositions can have different alloy disorder scattering, implying that an underlying mechanism, such as short‐range order, may be responsible and warrants further investigation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CHELAX-BNF: Fast Response Temperature by airborne measurements

The original data were collected on board the ARM Aerial Facility ArcticShark uncrewed aerial system (UAS; https://www.arm.gov/capabilities/observatories/aaf/uas ) during the “Characterizing HEterogeneous Land-Atmosphere eXchanges at BNF” field campaign (CHEAX-BNF; https://arm.gov/research/campaigns/aaf2025CHELAX-BNF ). The ARM Aerial Facility ArcticShark UAS was based at the public-use airport of Posey Field, AL (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from May 28 to June 23, 2025. The ArcticShark UAS performed 5 flights, including 4 research flights over the BNF Main Site (ARM Mobile Facility 3, https://arm.gov/capabilities/observatories/amf ) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration, and aerosol size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in the form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗

Initial Mobility Analysis for ORNL VA-EDH Synthetic Populations

Travel burdens are a major barrier to healthcare access among US Veteran patient populations, particularly those residing in rural areas. Spatial accessibility to points of care for US Veteran populations is commonly assessed in two ways. The first approach uses open data from the US Census to represent collective travel burdens, for example the distance between population-weighted census tract centroids and VHA points of care. The second approach uses restricted-access VHA patient data to measure travel costs (e.g., distance, time) for accessing points of care with respect to geolocated patient addresses and real or approximated transportation networks. While the advantage of the open data approach lies in its reproducibility, it has notable limitations in its tendency to infer individual travel behavior from aggregate population characteristics, a problem known as ecological fallacy. Conversely, while the patient data approach is able to account for individual travel behavior, its ability to account for localized access disparities (e.g., a neighborhood with exceptionally high transportation costs) and patient demographics is limited as protecting individual patient data requires their storage in closed systems with limited capacity for adequately modeling real-world travel patterns or for supplementing patient attributes. Additionally, the patient data approach cannot account for veterans who are not enrolled in the VHA system but who may be eligible for care. These challenges limit the ability to perform “what if” analyses on the effects of place-specific interventions on veteran populations with high access barriers to healthcare. To address these challenges, we explore the application of realistic synthetic populations to examine travel burdens and spatial accessibility issues among veteran patient populations. Synthetic populations provide a virtual, individually-resolved and cross-sectional representation of the veteran patient population that enables investigation of spatial access to points of care in ways in which aggregate data and patient data do not. First, synthetic populations allow one to directly assess how individuals access points of care, from synthesized residential locations to outpatient facilities on real-world transportation networks. Modeling access to points of care at the individual scale addresses the ecological fallacy problem associated with using aggregated census data to represent veteran populations and patterns of movement. Second, synthetic populations provide a means of completely representing an area’s veteran population using only publicly available, anonymized census microdata from the American Community Survey (ACS) to ensure the privacy of real-world individuals. Generating synthetic populations from the ACS also expands descriptive characteristics beyond what patient data typically offers to include socio-demographic, economic, housing, and mobility attributes. More detailed profiles of both VHA patient populations and veterans not enrolled in the VA system will provide a comprehensive picture of groups that may benefit from interventions or outreach. As an initial exercise for using synthetic populations to measure veteran travel burdens to VA care, we apply Oak Ridge National Laboratory’s (ORNL) UrbanPop capability to generate a series of synthetic VHA patient populations for 9 Veterans Integrated Services Networks (VISN) market areas in 9 Census Divisions across the continental United States, which are listed in Table 1. We use UrbanPop to produce synthetic populations for the VISN markets selected for each US Census Division, then assign VA outpatient clinic destinations to synthetic VHA patients based on travel about each VISN market’s road network. To demonstrate using the synthetic populations to evaluate healthcare travel burdens, we compare the time-based impedance between simulated home locations and VA outpatient clinics in each VISN market. We then perform validation exercises on the synthetic populations with respect to neighborhood (block group) demographic composition as well as patient mobility, comparing aggregate origin-destination statistics for the synthetic population to outpatient visits available in restricted patient data from the VA’s Corporate Data Warehouse (CDW) database.

97 MATHEMATICS AND COMPUTING↗

Unraveling the Effect of Conformational and Electronic Disorder in the Charge Transport Processes of Semiconducting Polymers

Charge transport in semiconducting polymers is inextricably linked to their microstructure, making the characterization of polymer morphology at all length-scales essential for understanding the factors that limit mobility in these materials. Indeed, charge transport depends both on the ability of polarons to delocalize at the approximately nanometer length-scale and navigate a complex energetic and morphological mesoscale landscape. While characterization of the mesoscale morphology of polymers is well-established, studies of the local chain packing and nanoscale disorder, which affect delocalization, can be significantly more difficult to carry out. Additionally, through infrared charge modulation spectroscopy and theoretical modeling, the effect of the local chain environment on polaron delocalization is directly measured and quantified. Using a series of polymers based on the model system, poly(3-hexylthiophene), the link between disorder and polaron localization is systematically explored. Polaron delocalization is correlated with known trends in mobility, revealing that while charge delocalization is always beneficial, the formation of tie-chains is necessary to reach the highest mobilities in semicrystalline polymers. The results provide direct evidence for the importance of both nanoscale (charge carrier delocalization) and mesoscale (tie-chains) orders, demonstrating the need to distinguish the key length-scale limiting charge transport in the design of new, high mobility polymers.

36 MATERIALS SCIENCE↗

Drones in Automation - Secured Unmanned Aerial Systems

Factories, refineries, utilities (water/wastewater, electric) and related industrial sites are complex systems and structures with inspection and maintenance procedures required for optimal operation and regulatory compliance. As a specific example, consider just the bulk electric power system which is comprised of more than 200,000 miles of highvoltage transmission lines, thousands of generation plants and millions of digital controls. More than 1,800 entities own and operate portions of the grid system, with thousands more involved in the operation of distribution networks across North America. The interconnected and interdependent nature of the bulk power system requires a consistent and systematic application of risk mitigation across the entire grid system to be truly effective. Similar situations are found throughout automation where frequently an aging infrastructure is in place too. Consider, for example, the situation present in a refinery or chemical processing setting with the requirement for leak detection inspection of pipes, interconnects and systems stretching across the plant. The current practices and challenges relating just to this task - leak detection and repair (LDAR) – of detecting any fugitive emissions present and documenting all measurements thereby meeting air compliance regulations are typically “handled” by a small army of individuals with handheld or backpack-sized detectors who crawl through piping racks conducting measurements at each flange. Such work is performed in difficult conditions (temperature, humidity, physically challenging) with frequently a high level of employee turnover. Finaly, enter low cost sensors and mobile platforms – in other words unmanned aerial systems (UASs, or drones) with enhanced sensing capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High thermoelectric performance in (Bi 0.25 Sb 0.75 ) 2 Te 3 due to band convergence and improved by carrier concentration control

Bi 2 Te 3 has been recognized as an important cooling material for thermoelectric applications. Yet its thermoelectric performance could still be improved. Here we propose a band engineering strategy by optimizing the converging valence bands of Bi 2 Te 3 and Sb 2 Te 3 in the (Bi 1-x Sb x ) 2 Te 3 system when x = 0.75. Band convergence successfully explains the sharp increase in density-of-states effective mass yet relatively constant mobility and optical band gap measurement. This band convergence picture guides the carrier concentration tuning for optimum thermoelectric performance. To synthesize homogeneous textured and optimally doped (Bi 0.25 Sb 0.75 ) 2 Te 3 , excess Te was chosen as the dopant. Uniform control of the optimized thermoelectric composition was achieved by zone-melting which utilizes separate solidus and liquidus compositions to obtain zT = 1.05 (at 300 K) without nanostructuring.

36 MATERIALS SCIENCE↗

X-ray fluorescence studies for the elemental composition and molecular organization of protein films on the surface of the liquid subphase

This paper reports on the results of the investigation of protein films that are based on alkaline phosphatase and glucose oxidase enzymes and formed on the surface of the liquid subphase. The experimental studies have been performed using total external reflection X-ray fluorescence spectrometry at the European Synchrotron Radiation Facility (Grenoble, France). The self-organization processes that occur in protein systems on the surface of the liquid subphase under the conditions where the protein molecules retain their mobility have been investigated using X-ray fluorescence measurements for the first time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress in utilization of a mobile laboratory for making storm electricity measurements

A mobile atmospheric science laboratory has been used to intercept and track storms on the Great Plains region of the U.S., with the intention of combining the data obtained with those from Doppler and conventional radars, NASA U-2 aircraft overflights, balloon soundings, and fixed-base storm electricity measurements. The mobile lab has proven to be valuable in the gathering of ground truth verifications for the two commercially operated lightning ground-strike locating systems. Data acquisition has recently been expanded by means of mobile ballooning before and during storms.

Rust, W. David↗

Lightning Instrumentation System

A new comprehensive lightning instrumentation system has been designed for the Mobile Launcher 1 (ML-1) at the Kennedy Space Center, Florida. This new instrumentation system includes the synchronized recording of three B-dot, 3-axis measurement stations, one D-dot sensor and eighteen vehicle measurement channels. Each vehicle measurement channel is comprised of two currents and one voltage measurements. The instrumentation system is composed of centralized transient recorders and digitizers, connected to the transient recorders via fiber optic cables. The transient recorders are triggered by the B-dot or D-dot sensors. When the Space Launch System (SLS) vehicle is present at the ML-1, the transient recorders record data on a dual sampling rate mode, continuous slow 5 kilo-samples per second (per channel) and event driven fast 100 mega-samples per second (per channel). Without the presence of the vehicle at the ML-1, the instrumentation system operates only as an event driven fast 100 mega-samples per second (per channel). In the absence of the vehicle, the only measurements recorded are the B-dot and D-dot stations. Additionally, a portable Lightning Monitoring System (LMS) is temporarily installed inside the Orion Crew Capsule module monitoring one portable B-dot, 3-axis measurement station, and 2 Crew Capsule BUS voltages. The portable LMS has a transient recorder independent of the ML-1 transient recorders, that is triggered by the portable B-dot sensor or transients on the vehicle BUS voltages. This portable instrumentation is removed while performing close out operations before the vehicle launch. For the ML-1 lightning instrumentation system, new custom B-dot and D-dot sensors were designed and prototypes were tested at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The Ground Special Power (GSP) vehicle measurement channels monitoring on the ML-1 is done via 1) Commercial off-the-shelf (COTS) current shunts and 2) custom Voltage Dividers. The new ML-1 lightning instrumentation system was designed, fabricated, deployed, and tested prior to the summer of 2019, in preparation for the first NASA's SLS mission to be launched from the Launch Complex 39B (LC-39B). The ML-1 lightning instrumentation was designed to complement the LC-39B lightning instrumentation system providing electromagnetic measurements closer to the vehicle, at different heights and inside the Crew capsule module.

Angel G Mata↗

An Observational Comparison of Level of Neutral Buoyancy and Level of Maximum Detrainment in Tropical Deep Convective Clouds

Tropical deep convective clouds are important drivers of large-scale atmospheric circulation representing the main vertical transport pathway through the depth of the troposphere for heat, momentum, water, and chemical species. The strength and depth of this transport are impacted by the convective updraft size and intensity that are driven by buoyancy, dynamical forcing, and mixing of environmental air, i.e., entrainment. In this paper, we identify tropical deep convective systems with well-defined forward anvils using Atmospheric Radiation Measurement (ARM) ground-based profiling radars, at three ARM fixed-sites in the Tropical Western Pacific (TWP; i.e., Manus, Nauru, Darwin) and three ARM Mobile Facility deployments in Niamey, Niger; Gan Island, Maldives; and Manacapuru, Brazil. We use the difference between the level of neutral buoyancy (LNB) and the level of maximum detrainment (LMD) as a proxy for the effective bulk convective entrainment (εproxy). The LNB, the theoretical height that a parcel raised above the level of free convection would reach with no mixing, is calculated based on pre-convection radiosonde measurements using parcel theory. The LMD is the height of the maximum reflectivity observed in forward anvil clouds by profiling radars. Deep convective systems over the TWP show higher LNBs that extend to 16.3 km on average and larger εproxy (median LNB minus LMD up to 6.5 km) compared to their continental counterparts in the Amazon and West Africa. Oceanic conditions show larger convective available potential energy (CAPE) coupled with higher moisture at low levels which favors larger εproxy. In contrast, continental cases initiate and develop under high convective inhibition, steeper environmental lapse rate, and high wind shear conditions, which show smaller offset between LNB and LMD. Deep convective cases that promote significant cold pools at the surface experience less εproxy. Using a Random Forest regression algorithm, CAPE is associated with the highest feature importance score for predicting convective εproxy, followed by low-level relative humidity. For continental cases, the low-level wind shear also indicates higher importance.

54 ENVIRONMENTAL SCIENCES↗

Wildfire Emission Transport and Its Impact on the Local Air Quality – Case Study Example from the LISTOS Campaign

The high O3 concentration and large aerosol backscatter were measured in New York City(NYC) region and Connecticut (CT) coastline between August 15-16, 2018 during the Long Island Sound Tropospheric Ozone Study (LISTOS) campaign. Two TOLNet ozone lidar systems, NASA Goddard Space Flight Center Tropospheric Ozone Differential Absorption Lidar (GSFC TROPOZ DIAL)and Langley Research Center (LaRC) Mobile Ozone Lidar (LMOL),were used to obtain vertical and temporal variation of local O3 concentration. The airborne High Altitude Lidar Observatory (HALO) system was used to detect the regional aerosol characteristic during this episode. The complex relationship between ozone and aerosol characteristics of wildfire emission layers was investigated. The HYSPLIT back-trajectory of the measured air parcel shows that the increase of the O3 concentration and aerosol backscatter are attributed to the significant wildfires in the Pacific Northwest and British Columbia regions during August 2018. Through correlation analyses, unique clustering relationships are identified between ozone and aerosol for different air mass types. This case study is further investigated in relation to satellite data from MODIS, MISR and CALIPSO to characterize plume behavior during transport. The importance of wildfire emission transport will be discussed in context of its impact to surface air quality at significant distances from fire events.

Liqiao Lei↗

Chemical, Biological, and Explosive Sensors for Field Measurements

Special Technologies Laboratory (STL) is developing handheld chemical, biological, and explosive (CBE) detection systems and sensor motes for wireless networked field operations. The CBE sensors are capable of detecting and identifying multiple targeted toxic industrial chemicals (TICs) and high-explosive vapor components. The CBE devices are based on differential mobility spectrometry (DMS) coupled with fast gas chromatography (GC) or mass spectrometry. The systems all include the concepts of: 1. Direct air/particulate “smart” sampling 2. Selective, continuous real-time (~1 sec) alert monitoring using DMS 3. Highly selective, rapid dual technology separation/verification analysis The biosensor technology is based on Raman aerosol particle flow cytometry for target detection and identification. Monitoring and identifying trace level chemical vapors directly from ambient air will allow First Responders to quickly adapt situational response strategies and personal protective equipment needs to the specific response scenario being encountered. First Responders require great confidence in the measurements and ability of a given system to detect CBE below threshold levels without interferences. The concept of determining the background matrix in near real-time to allow subsequent automated field-programmable method selection and cueing of high-value assets in a wide range of environs will be presented. This provides CBE information for decisions prior to First Responders entering the response site or sending a portable mobile unit for a remote site survey of the hazards. The focus is on real-time information needed by those responsible for emergency response and national security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation on oil migration and accumulation in tight sandstones

Here, this study presents an experimental investigation to simulate and analyze the physical processes of oil migration and accumulation with 19 tight sandstone cores. Characteristic curves of oil migration were obtained by using the experimental results. It shows that the curve variations were mainly influenced by two factors: the permeability of the core and the viscosity of the injected oil. Based on the experimental results, we introduced three important parameters to quantitatively characterize and determine the processes of oil migration and accumulation in tight sandstones. The apparent permeability was introduced to describe the level of oil migration during experiments. The minimum migration pressure gradient (MMPG) and the terminal oil saturation were proposed to evaluate the features of the beginning and final stages of the migration, respectively. The relationships between MMPG, terminal oil saturation and mobility were analyzed, all showed strong linear relationships in the double logarithmic coordinate system. Furthermore, a prediction map of tight oil accumulation was plotted according to the measured oil saturation data, which could be used for estimating the scale and size of oil accumulation in tight reservoirs. Lastly, the concepts and results in this study provide valuable insight for understanding and quantitatively analyzing the processes of oil migration and accumulation in tight sandstones.

58 GEOSCIENCES↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Imaging of the Coexistence of Ferromagnetism and Superconductivity at the LaA1O3/SrTiO3 Interface

LaAlO{sub 3} and SrTiO{sub 3} are insulating, nonmagnetic oxides, yet the interface between them exhibits a two-dimensional electron system with high electron mobility, superconductivity at low temperatures, and electric-field-tuned metal-insulator and superconductor-insulator phase transitions. Bulk magnetization and magnetoresistance measurements also suggest some form of magnetism depending on preparation conditions and suggest a tendency towards nanoscale electronic phase separation. Here we use local imaging of the magnetization and magnetic susceptibility to directly observe a landscape of ferromagnetism, paramagnetism, and superconductivity. We find submicron patches of ferromagnetism in a uniform background of paramagnetism, with a nonuniform, weak diamagnetic superconducting susceptibility at low temperature. These results demonstrate the existence of nanoscale phase separation as suggested by theoretical predictions based on nearly degenerate interface subbands associated with the Ti orbitals. The magnitude and temperature dependence of the paramagnetic response suggests that the vast majority of the electrons at the interface are localized, and do not contribute to transport measurements. In addition to the implications for magnetism, the existence of a 2D superconductor at an interface with highly broken inversion symmetry and a ferromagnetic landscape in the background suggests the potential for exotic superconducting phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗