Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Minimum variance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

An Evaluation of the Quality of Halogen Occultation Experiment Ozone Profiles in the Lower Stratosphere

The archived ozone profiles from the Halogen Occultation Experiment (HALOE) have already been corrected for the effects of the spectrally varying, interfering absorption due to aerosols composed of aqueous sulfuric acid, and agreement with correlative measurements in the stratosphere is generally excellent. However, comparisons of sets of coincident HALOE and ozonesonde profiles indicate occasional large differences at the lowest levels of the stratosphere. Most of those instances occur at altitudes just below a well-defined minimum in the 5.26 microns channel aerosol extinction profile, whose wavelength dependence is not represented by a sulfuric acid aerosol model. Further, when the aerosol extinction exceeds about 10(exp 3)/ km, the aerosol correction to the ozone channel transmittances is both large and uncertain. After screening out the HALOE ozone profile segments whose corresponding aerosol/cirrus corrections are likely uncertain and after averaging lie ozonesonde profiles into 2.5 km thick layers, we find that the HALOE ozone areas, on average, to within 10% of their coincident ozonesonde measurements down to 100 hPa at tropical/subtropical latitudes and to 200 hPa at extratropical latitudes. A tightening of the coincidence criteria for the comparisons does not improve the mean differences for the sets nearly as much. Part of the variance of the paired differences was also accounted for when the ozonesonde profile values were integrated into those 2.5 km layers, prior to taking differences. This improvement is due mainly to the vertical averaging of the local, higher-resolution ozonesonde data, matching the lower resolution for HALOE ozone in the lower stratosphere. It is concluded that HALOE is providing accurate ozone profiles throughout the lower stratosphere, when its correction for interfering aerosols has been well characterized and when cirrus layers are not indicated.

Bhatt, Praful P.↗

Robustness analysis of an air heating plant and control law by using polynomial chaos

This paper presents a robustness analysis of an air heating plant with a multivariable closed-loop control law by using the polynomial chaos methodology (MPC). The plant consists of a PVC tube with a fan in the air input (that forces the air through the tube) and a mass flux sensor in the output. A heating resistance warms the air as it flows inside the tube, and a thermo-couple sensor measures the air temperature. The plant has thus two inputs (the fan's rotation intensity and heat generated by the resistance, both measured in percent of the maximum value) and two outputs (air temperature and air mass flux, also in percent of the maximal value). The mathematical model is obtained by System Identification techniques. The mass flux sensor, which is nonlinear, is linearized and the delays in the transfer functions are properly approximated by non-minimum phase transfer functions. The resulting model is transformed to a state-space model, which is used for control design purposes. The multivariable robust control design techniques used is the LQG/LTR, and the controllers are validated in simulation software and in the real plant. Finally, the MPC is applied by considering some of the system's parameters as random variables (one at a time, and the system's stochastic differential equations are solved by expanding the solution (a stochastic process) in an orthogonal basis of polynomial functions of the basic random variables. This method transforms the stochastic equations in a set of deterministic differential equations, which can be solved by traditional numerical methods (That is the MPC). Statistical data for the system (like expected values and variances) are then calculated. The effects of randomness in the parameters are evaluated in the open-loop and closed-loop pole's positions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of cosmic variance on the galaxy-halo connection for Lyα emitters

In this paper we study the impact of cosmic variance and observational uncertainties in constraining the mass and occupation fraction, f{sub occ}, of dark matter (DM) halos hosting Lyα-emitting galaxies (LAEs) at high redshift. To this end, we construct mock catalogs from an N-body simulation to match the typical size of observed fields at z = 3.1 (∼1 deg{sup 2}). In our model a DM halo with mass in the range M{sub min}<M{sub h}<M{sub max} can only host one detectable LAE at most. We proceed to explore the parameter space determined by M{sub min}, M{sub max}, and f{sub occ} with a Markov Chain Monte Carlo algorithm using the angular correlation function and the LAEs’ number density as observational constraints. We find that the preferred minimum and maximum masses in our model span a wide range 10{sup 10.0}h{sup −1}M{sub ⊙}⩽M{sub min}⩽10{sup 11.1}h{sup −1}M{sub ⊙}, 10{sup 11.0}h{sup −1}M{sub ⊙}⩽M{sub max}⩽10{sup 13.0}h{sup −1}M{sub ⊙}, followed by a wide range in the occupation fraction 0.02⩽f{sub occ}⩽0.30. As a consequence, the median mass, M {sub 50}, of all the consistent models has a large uncertainty M{sub 50}=3.16{sub −2.37}{sup +9.34}×10{sup 10} h{sup −1}M{sub ⊙}. However, we find that the same individual models have a relatively tight 1σ scatter around the median mass ΔM{sub 1σ}=0.55{sub −0.31}{sup +0.11} dex. We are also able to show that f{sub occ} is uniquely determined by M{sub min}, regardless of M{sub max}. We argue that upcoming large surveys covering at least 25 deg{sup 2} should be able to put tighter constraints on M{sub min} and f{sub occ} through the LAE number density distribution width constructed over several fields of ∼1 deg{sup 2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data-driven predictive probability density function control of fiber length stochastic distribution shaping in refining process

Pulp is the most important raw material in paper in paper industries, whose Fiber Length Stochastic Distribution (FLSD) shaping directly determines the energy consumption and paper quality of the subsequent papermaking processes. However, the mean and variance are insufficient to describe the output FLSD shaping, which display non-Gaussian distribution properties. Therefore, the traditional control, method based on the mean and variance of fiber length is difficult to control the FLSD shaping effectively. In this paper, a novel data-driven predictive probability density function (PDF) control method is proposed for output FLSD shaping in refining process. Primarily, in order to improve the approximation accuracy of the PDF employing RBF neural network, the parameters (center value and width) of each RBF basis functions are tuned via utilizing iterative learning control (ILC) law, and the corresponding estimations of weights law can be obtained. Secondly, considering that the conventional linear model of weights vector has drawbacks of low accuracy and weak generalization ability, random vector functional link networks (RVFLNs) based data driven nonlinear modelling method is employed to characterize the prediction model between the input variables and weights vector. Finally, in order to reduce the randomness of the output FLSD, a minimum entropy control method under mean constraint is employed to design the predictive PDF controller for the output FLSD shaping with the help of the established nonlinear stochastic distribution model. Both simulations and experiments are given to illustrate the effectiveness and practicability of the proposed method.

Probability debsity function, Fiber length distrib↗

Evaluation of multiple reduced-order models to enhance confidence in global sensitivity analyses

Variance-based global sensitivity analysis (e.g., the Sobol' sensitivity index) can be used to identify the important parameters over the entire parameter space. However, one often cannot afford the computational costs of sampling-based approaches in combination with expensive high-fidelity forward models. Reduced-order models (ROM) can substantially accelerate calculation of these sensitivities. However, it is usually difficult to determine what type of ROM should be used and how accurately the ROM represents the high-fidelity model (HFM) results. Here in this paper, we propose to concurrently use multiple ROMs as a way to assess the robustness of the model-reduction method. Two sets of HFM simulations are needed, one set for building ROMs and the other for validating ROMs. Our goal is to keep the total number of HFM simulations to a minimum. Ideally some of the HFM simulations in the first set can be shared by different ROMs. Based on validation results, the ROMs can be combined with different schemes. We demonstrate that we can achieve the goal by using four different ROMs and still considerably save computational time compared to using traditional HFM simulation for calculating sensitivity indices. We apply the approach to an example problem of a large-scale geological carbon dioxide storage system, in which the objective is to calculate a sensitivity index to identify important parameters. For this problem, the locally best ROM provides better estimates than the weighted average from all ROMs.

54 ENVIRONMENTAL SCIENCES↗

Transmission estimation at the quantum Cramér-Rao bound with macroscopic quantum light

The field of quantum metrology seeks to apply quantum techniques and/or resources to classical sensing approaches with the goal of enhancing the precision in the estimation of a parameter beyond what can be achieved with classical resources. Theoretically, the fundamental minimum uncertainty in the estimation of a parameter for a given probing state is bounded by the quantum Cramér-Rao bound. From a practical perspective, it is necessary to find physical measurements that can saturate this fundamental limit and to show experimentally that it is possible to perform measurements with the required precision to do so. Here we perform experiments that saturate the quantum Cramér-Rao bound for transmission estimation over a wide range of transmissions when probing the system under study with a continuous wave bright two-mode squeezed state. To properly take into account the imperfections in the generation of the quantum state, we extend our previous theoretical results to incorporate the measured properties of the generated quantum state. For our largest transmission level of 84%, we show a 62% reduction over the optimal classical protocol in the variance in transmission estimation when probing with a bright two-mode squeezed state with -8 dB of intensity-difference squeezing. Given that transmission estimation is an integral part of many sensing protocols, such as plasmonic sensing, spectroscopy, calibration of the quantum efficiency of detectors, etc., the results presented promise to have a significant impact on a number of applications in various fields of research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Classical spin glass system in external field with taking into account relaxation effects

We study statistical properties of disordered spin systems under the influence of an external field with taking into account relaxation effects. For description of system the spatial 1D Heisenberg spin-glass Hamiltonian is used. In addition, we suppose that interactions occur between nearest-neighboring spins and they are random. Exact solutions which define angular configuration of the spin in nodes were obtained from the equations of stationary points of Hamiltonian and the corresponding conditions for the energy local minimum. On the basis of these recurrent solutions an effective parallel algorithm is developed for simulation of stabile spin-chains of an arbitrary length. It is shown that by way of an independent order of N{sup 2} numerical simulations (where N is number of spin in each chain) it is possible to generate ensemble of spin-chains, which is completely ergodic which is equivalent to full self-averaging of spin-chains' vector polarization. Distributions of different parameters (energy, average polarization by coordinates, and spin-spin interaction constant) of unperturbed system are calculated. In particular, analytically is proved and numerically is shown, that for the Heisenberg nearest-neighboring Hamiltonian model, the distribution of spin-spin interaction constants as opposed to widely used Gauss-Edwards-Anderson distribution satisfies Levy alpha-stable distribution law. This distribution is nonanalytic function and does not have variance. In the work we have in detail studied critical properties of an ensemble depending on value of external field parameters (from amplitude and frequency) and have shown that even at weak external fields the spin-glass systemis strongly frustrated. It is shown that frustrations have fractal behavior, they are selfsimilar and do not disappear at scale decreasing of area. By the numerical computation is shown that the average polarization of spin-glass on a different coordinates can have values which can lead to catastrophes in the equation ofClausius-Mossotti for dielectric constant. In other words, for some values of external field parameter, a critical phenomenon occurs in the system which is impossible to describe by the real-valued Heisenberg spin-glass Hamiltonian. For the solution of this problem at first the complex-valued disordered Hamiltonian is used. Physically this type of extension of Hamiltonian allows to consider relaxation effects which occur in the system under the influence of an external field. On the basis of developed approach an effective parallel algorithm is developed for simulation of statistic parameters of spin-glass system under the influence of an external field.

74 ATOMIC AND MOLECULAR PHYSICS↗

A regional (land–ocean) comparison of the seasonal to decadal variability of the Northern Hemisphere jet stream 1871–2011

Seasonal to decadal variations in Northern Hemisphere jet stream latitude and speed over land (Eurasia, North America) and oceanic (North Atlantic, North Pacific) regions are presented for the period 1871–2011 from the Twentieth Century Reanalysis dataset. Significant regional differences are seen on seasonal to decadal timescales. Seasonally, the jet latitude range is lower over the oceans compared to land, reduced from 20° over Eurasia to 10° over the North Atlantic where the ocean meridional heat transport is greatest. The mean jet latitude range is at a minimum in winter (DJF), particularly along the western boundary of the North Pacific and North Atlantic, where the land-sea contrast and SST gradients are strongest. The 141-year trends in jet latitude and speed show differences on a regional basis. The North Atlantic has significant increasing jet latitude trends in all seasons, up to 3° in winter. Eurasia has significant increasing trends in winter and summer, however, no increase is seen across the North Pacific or North America. Jet speed shows significant increases evident in winter (up to 4.7 ms –1 ), spring and autumn over the North Atlantic, Eurasia and North America however, over the North Pacific no increase is observed. Long term trends are generally overlaid by multidecadal variability, particularly evident in the North Pacific, where 20-year variability in jet latitude and jet speed are seen, associated with the Pacific Decadal Oscillation which explains 50% of the winter variance in jet latitude since 1940. The results highlight that northern hemisphere jet variability and trends differ on a regional basis (North Atlantic, North Pacific, Eurasia and North America) on seasonal to decadal timescales, suggesting that different mechanisms are influencing the jet latitude and speed. This is important from a climate modelling perspective and for climate predictions in the near and longer term.

54 ENVIRONMENTAL SCIENCES↗

A hierarchical analysis of the impact of methodological decisions on statistical downscaling of daily precipitation and air temperatures

Despite the widespread application of statistical downscaling tools, uncertainty remains regarding the role of model formulation in determining model skill for daily maximum and minimum temperature (Tmax and Tmin), and precipitation occurrence and intensity. Impacts of several key aspects of statistical transfer function form on model skill are evaluated using a framework resistant to model overspecification. We focus on: (a) model structure: simple (generalized linear models, GLMs) versus complex (artificial neural networks, ANNs) models. (b) Predictor selection: Fixed number of predictors chosen a priori versus stepwise selection of predictors and inclusion of grid point values versus predictors derived from application of principal components analysis (PCA) to spatial fields. We also examine the influence of domain size on model performance. For precipitation downscaling, we consider the role of the threshold used to characterize a wet day and apply three approaches (Poisson and Gamma distributions in GLM and ANN) to downscale wet-day precipitation amounts. While no downscaling formulation is optimal for all predictands and at 10 locations representing diverse U.S. climates, and due to the exclusion of variance inflation all of the downscaling formulations fail to reproduce the range of observed variability, models with larger suites of prospective predictors generally have higher skill. For temperature downscaling, ANNs generally outperform GLM, with greater improvements for T min than T max . Furthermore, use of PCA-derived predictors does not systematically improve model skill, but does improve skill for temperature extremes. Model skill for precipitation occurrence generally increases as the wet-day threshold increases and models using PCA-derived predictors tend to outperform those based on grid cell predictors. Each model for wet-day precipitation intensity overestimates annual total precipitation and underestimates the proportion derived from extreme precipitation events, but ANN-based models and those with larger predictor suites tend to have the smallest bias.

54 ENVIRONMENTAL SCIENCES↗

Reliability Evaluation of Base-Metal-Electrode Multilayer Ceramic Capacitors for Potential Space Applications

Base-metal-electrode (BME) ceramic capacitors are being investigated for possible use in high-reliability spacelevel applications. This paper focuses on how BME capacitors construction and microstructure affects their lifetime and reliability. Examination of the construction and microstructure of commercial off-the-shelf (COTS) BME capacitors reveals great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and 0.5 m, which is much less than that of most PME capacitors. BME capacitors can be fabricated with more internal electrode layers and thinner dielectric layers than PME capacitors because they have a fine-grained microstructure and do not shrink much during ceramic sintering. This makes it possible for BME capacitors to achieve a very high capacitance volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT). Most BME capacitors were found to fail with an early avalanche breakdown, followed by a regular dielectric wearout failure during the HALT test. When most of the early failures, characterized with avalanche breakdown, were removed, BME capacitors exhibited a minimum mean time-to-failure (MTTF) of more than 105 years at room temperature and rated voltage. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically around 12 for a number of BME capacitors with a rated voltage of 25V. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. The leakage current characterization and the failure analysis results suggest that most of these early avalanche failures are due to the extrinsic minor construction defects introduced during fabrication of BME capacitors. The concentration of the extrinsic defects must be reduced if the BME capacitors are considered for high reliability applications. There are two approaches that can reduce or prevent the occurrence of early failure in BME capacitors: (1) to reduce the defect concentration with improved processing control; (2) to prevent the use of BME capacitors under harsh external stress levels so that the extrinsic defects will never be triggered for a failure. In order to do so appropriate dielectric layer thickness must be determined for a given rated voltage.

Liu, David (Donhang)↗

A Multi-State Model for Catalyzing the National Home Energy Retrofit Market (Final Technical Report)

In the fall of 2010, the Alabama Department of Economic and Community Affairs (ADECA) launched the Multi-State Model for Catalyzing the National Home Energy Retrofit Market Project (Multi-State Project). This residential energy efficiency pilot program was a collaborative effort among the states of Alabama, Massachusetts, Virginia, and Washington, and was funded by competitive State Energy Program (SEP) awards through the U.S. Department of Energy (DOE). The objective of this project was to catalyze the home energy efficiency retrofit market in select areas within the state of Alabama. To achieve this goal, the project addressed a variety of marketplace elements that did not exist, or were underdeveloped, at the outset of the effort. These included establishing minimum standards and credentials for marketplace suppliers, educating and engaging homeowners on the benefits of energy efficiency and addressing real or perceived financial barriers to investments in whole-home energy efficiency, among others. The anticipated effect of the activities would be increased market demand for retrofits, improved audit to retrofit conversion rates and growth in overall community understanding of energy efficiency. The four-state collaborative was created with the intent of accelerating market transformation by allowing each state to learn from their peers, each of whom possessed different starting points, resources, and strategies for achieving the overall objective. The four partner states engaged the National Association of State Energy Officials (NASEO) to oversee a project steering committee and to manage the project evaluation for all four states. The steering committee, comprised of key program partners, met on a regular basis to provide overall project coordination, guidance, and progress assessment. While there were variances in program design among the states, there were several common elements: use of the Energy Performance Score (EPS) platform; an audit and home energy rating tool; emphasis on community based coordination and partnerships; marketing and outreach to increase homeowner participation; training for market actors; access to financing options including rebates, incentives, and loan products; and an in depth process evaluation to support continual program improvement and analysis. In Alabama, Nexus Energy Center operated energy efficiency retrofit programs in Huntsville and Birmingham. In the Huntsville community the AlabamaWISE program was available in five Alabama counties: Cullman, Lawrence, Limestone, Madison, and Morgan. In Birmingham, the program was available to residents in Jefferson and Shelby Counties. In both communities, the program was similar in terms of program design but tailored marketing and partnerships to address the unique local conditions and population of each community. ADECA and the Southeast Energy Efficiency Alliance (SEEA) provided overall project management services and common resources to the local program administrator Nexus Energy Center, including contracted services for contractor training, quality assurance testing, data collection and reporting, and compliance. The fundamental components of the AlabamaWISE program included a vertical contractor-based business model; comprehensive energy assessments; third-party quality assurance; rebates for installation of energy saving measures; accessible, low-interest financing; targeted and inbound marketing; Energy Performance Score (EPS) tool to engage and educate homeowners; training for auditors, contractors, and real estate professionals; and online resources for education and program enrollment. Program participants were eligible to receive rebates or financing toward the assessments and upgrades to their home provided they reached at least 20 percent deemed or modeled energy savings. The design of each program focused on addressing several known barriers including: limited homeowner knowledge on the benefits of energy efficiency, lack of financing options, lack of community support for energy efficiency programs, and lack of trained market actors including contractors and real estate professionals. The programs were able to make progress on addressing all of these barriers and were most successful in offering financing options and training market actors. The most challenging barriers proved to be the act of building a market for energy efficiency where none previously existed, convincing homeowners of the value in investing in energy efficiency (and therefore completing retrofits), engaging electric and natural gas utilities to partner on delivery, and achieving the overall project target of 1,365 completed retrofits. The components that proved to be the most valuable to program success were engaged contractor networks that could promote and endorse the program, partnerships with local business and organizations, and the access to rebates, incentives and financing mechanisms. The programs were successful in building relationships with a variety of community participants including: local contractors, Associations of REALTORS, home builders associations, universities, utilities, local and state governments, and other non-profit organizations. Throughout this program, 933 building audits and 795 building retrofits were completed making homes in Alabama more comfortable, less expensive to operate, more valuable to the marketplace, and safer and healthier for families. Continuing on this momentum, Nexus Energy Center plans to continue operating and expanding operations in Alabama as a Home Performance with ENERGY STAR sponsor and will continue to provide energy services and education to communities in Alabama.

Grimes, Elizabeth M.↗

A DNS evaluation of mixing models for transported PDF modelling of turbulent nonpremixed flames

Transported probability density function (TPDF) approaches are well suited to modelling turbulent, reacting, variable density flows. One of the main challenges to the successful deployment of TPDF methods is accurately modelling the unclosed molecular mixing term. This study examines three of the most widely used mixing models: the Interaction by Exchange with the Mean (IEM), Modified Curl (MC) and Euclidean Minimum Spanning Tree (EMST) models. Direct numerical simulation (DNS) data-sets were used to provide both initial conditions and inputs needed over the course of the runs, including the mean flow velocities, mixing frequency, and the turbulent diffusion coefficient. The same chemical mechanism and thermodynamic properties were used, allowing the study to focus on the mixing model. The simulation scenario was a one-dimensional, nonpremixed, turbulent jet flame burning either a syngas or ethylene fuel stream that featured extinction and reignition. This test scenario was selected because extinction and reignition phenomena are sensitive to the mixing model. Three DNS cases were considered for both the syngas and ethylene cases with a parametric variation of Reynolds and Damköhler numbers, respectively. Extinction events became more popular with increasing Reynolds number in the syngas cases and with decreasing Damköhler number in the ethylene cases. The model was first tested with the mixing frequency defined from the dissipation rate and variance of mixture fraction. With this definition, for the syngas cases this study finds that the TPDF method is successful at predicting flame extinction and reignition using all three mixing models for the relatively lower and intermediate Reynolds number cases, but that all models under-predict reignition in the relatively higher Reynolds number case. In the ethylene fuelled cases, only the EMST mixing model correctly predicts the reignition event for the two higher Damköhler number cases, yet, in the lowest Damköhler number case the EMST model over-predicts reignition and the IEM and MC models under-predict it. Mixing frequency was then modelled based on the turbulence frequency and a model constant $C_{\phi}$, the ratio of scalar to mechanical mixing rates. The DNS cases were reexamined with this definition and the findings suggested that the optimal value for $C_{\phi}$ is mixing model and case dependent. In particular, it was found in the ethylene case considered that reignition could be achieved with the IEM and MC models by adjusting the value of $C_{\phi}$.

42 ENGINEERING↗

Reliability Evaluation of Base-Metal-Electrode (BME) Multilayer Ceramic Capacitors for Space Applications

This paper reports reliability evaluation of BME ceramic capacitors for possible high reliability space-level applications. The study is focused on the construction and microstructure of BME capacitors and their impacts on the capacitor life reliability. First, the examinations of the construction and microstructure of commercial-off-the-shelf (COTS) BME capacitors show great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and approximately 0.5 micrometers, which is much less than that of most PME capacitors. The primary reasons that a BME capacitor can be fabricated with more internal electrode layers and less dielectric layer thickness is that it has a fine-grained microstructure and does not shrink much during ceramic sintering. This results in the BME capacitors a very high volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT) and regular life testing as per MIL-PRF-123. Most BME capacitors were found to fail· with an early dielectric wearout, followed by a rapid wearout failure mode during the HALT test. When most of the early wearout failures were removed, BME capacitors exhibited a minimum mean time-to-failure of more than 10(exp 5) years. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically between 10 and 20. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. Since BME capacitors have a much smaller grain size than PME capacitors, it is reasonable to predict that BME capacitors with thinner dielectric layers may have an equivalent life expectancy to that of PME capacitors with thicker dielectric layers.

Liu, David (Donghang)↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Receiver Operating Characteristic Curves to Optimize Discovery-Based Software with Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry

We report a quantitative approach to optimize implementation of discovery-based software for comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS). The software performs a tile-based Fisher ratio (F-ratio) analysis, and facilitates a supervised non-targeted analysis based upon the experimental design to aid in the discovery of analytes whose variances are statistically different between sample classes. The quantitative approach for software optimization uses receiver operating characteristic (ROC) curves. The area under the curve (AUC) of each ROC curve serves as a quantitative metric to optimize two key algorithm parameters: the signal-to-noise ratio (S/N) threshold of the baseline corrected and normalized data prior to calculating F-ratios at each m/z mass channel, and the number of these F-ratios per m/z to include in the calculation of the average F-ratio of a tile. A total of 25 combinations of S/N threshold by number of m/z were studied. Fifty analytes were spiked into a diesel fuel at two concentration spike levels to produce two sample classes that should in principle produce 50 positive instances in the ROC curves (30 native/20 non-native compounds, at spike levels of 200/20 and100/10 ppm native/non-native, respectively). The “sweet spot” for F-ratio analysis was determined to be a S/N threshold of 10 coupled with a maximum of the 10 most chemically selective m/z (requiring a minimum of 3 m/z), corresponding to a ~ 21% improvement in the discovery rate of true positives relative to prior studies. Furthermore, it was observed that optimization of these software parameters did not depend upon a priori determination of the statistically correct number of positive instances in the sample classes. The AUC metric appears to be suitable for the evaluation of all data analysis methods that utilize the proper experimental design.

3D-GS/TOFMS, Data discovery, ROC curves, Fisher ra↗