Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Technique for Performing Dielectric Property Measurements at Microwave Frequencies

A method, system, apparatus, and computer readable medium has been provided with the ability to obtain a complex permittivity dielectric or a complex permeability micron of a sample in a cavity. One or more complex-valued resonance frequencies f(sub m) of the cavity, wherein each f(sub m) is a measurement, are obtained. Maxwell's equations are solved exactly for dielectric, and/or micron, using the f(sub m) as known quantities, thereby obtaining the dielectric and/or micron of the sample.

Barmatz, Martin B.↗

Microwave-Mediated Extraction of Critical Metals from LED E-Waste

This study introduces a microwave-assisted technique for extracting critical minerals from LED electronic waste. The process begins with microwave irradiation, which thermally decomposes the LED’s plastic lens into a brittle, charred residue. During this stage, the LED chip undergoes deflagration—being rapidly ejected from the reflective cavity and becoming embedded within the decomposed lens material. Consequently, the chip is encapsulated in the resulting charred residue. This composite, consisting of the charred lens and the LED chip, can be easily separated from the metallic pins (Fe, Ni, Ag), which remain almost undamaged. Subsequent calcination of the charred material in air exposes the materials making up the LED chip, which contain critical metals (e.g., Ga, As, In, Y, Au). These metals are then extracted through a two-step acid leaching process involving aqua regia followed by hot concentrated hydrochloric acid, yielding them in potentially recoverable forms. The synergistic effect of microwave irradiation and acid treatment achieves an average extraction efficiency of 96% for critical metals. Notably, this approach enables complete and loss-free recovery of the LED chip, offering a practical and efficient solution for LED e-waste recycling.

Bourlinos, Athanasios B.↗

Mode Orientation Control For Sapphire Dielectric Ring Resonator

Small sapphire tuning wedge used in technique for solving mode-purity problem associated with sapphire dielectric-ring resonator part of cryogenic microwave frequency discriminator. Breaks quasi-degeneracy of two modes and allows selective coupling to just one mode. Wedge mounted on axle entering resonator cavity and rotated while resonator cryogenically operating in vacuum. Furthermore, axle moved vertically to tune resonant frequency.

Santiago, David G.↗

Nearly Quantum-Limited Josephson-Junction Frequency-Comb Synthesizer

While coherently driven Kerr microcavities have rapidly matured as a platform for frequency-comb formation, such microresonators generally possess weak Kerr coefficients; consequently, triggering comb generation requires millions of photons to be circulating inside the cavity. This suppresses the role of quantum fluctuations in the dynamics of the comb. In this paper, we realize a minimal version of coherently driven Kerr-mediated microwave-frequency combs in the circuit quantum electrodynamics (cQED) architecture, where the fluctuations of the quantum vacuum are the primary limitation on comb coherence. We achieve a comb phase coherence of up to 35 μs, approaching the theoretical device quantum limit of 55 μs and vastly longer than the inherent lifetimes of the modes, of 13 ns. The ability within cQED to engineer stronger nonlinearities than optical microresonators, together with operation at cryogenic temperatures, and the excellent agreement of comb dynamics with quantum theory indicates a promising platform for the study of complex dynamics of quantum nonlinear systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, construction and evaluation of a 12.2 GHz, 4.0 kW-CW high efficiency klystron amplifier

An analytical and experimental program is described, for studying design techniques for optimizing the conversion efficiency of klystron amplifiers, and to utilize these techniques in the development and fabrication of an X-band 4 kW cw klystron, for use in satellite-borne television broadcast transmitters. The design is based on a technique for increasing the RF beam current by using the second harmonic space charge forces in the bunched beam. Experimental analysis was also made of a method to enhance circuit efficiency in the klystron cavities. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments employing an axisymmetric, electrostatic collector for linear beam microwave tubes.

Vishida, J. M.↗

Apparatus for Use in Determining Surface Conductivity at Microwave Frequencies

An apparatus is provided for use in determining surface conductivity of a flat or shaped conductive material at microwave frequencies. A plate has an electrically conductive surface with first and second holes passing through the plate. An electrically conductive material under test (MUT) is maintained in a spaced apart relationship with the electrically conductive surface of the plate by one or more nonconductive spacers. A first coupling loop is electrically shielded within the first hole while a second coupling loop is electrically shielded within the second hole. A dielectric resonator element is positioned between the first and second coupling loops, while also being positioned closer to the MUT than the electrically conductive surface of the plate. Microwave energy at an operating frequency f is supplied from a signal source to the first coupling loop while microwave energy received at the second coupling loop is measured. The apparatus is capable of measuring the Q-factor of the dielectric resonator situated in the 'cavity' existing between the electrically conductive surface of the plate and the MUT. Surface conductivity of the electrically conductive surface can be determined via interpolation using: 1 ) the measured Q-factor with the electrically conductive surface in place, and 2) the measured Q-factor when the MUT is replaced with reference standards having known surface conductivities.

Hearn, Chase P.↗

Apparatus for use in determining surface conductivity at microwave frequencies

An apparatus is provided for use in determining surface conductivity of a flat or shaped conductive material at microwave frequencies. A plate has an electrically conductive surface with first and second holes passing through the plate. An electrically conductive material under test (MUT) is maintained in a spaced apart relationship with the electrically conductive surface of the plate by one or more non-conductive spacers. A first coupling loop is electrically shielded within the first hole while a second coupling loop is electrically shielded within the second hole. A dielectric resonator element is positioned between the first and second coupling loops, while also being positioned closer to the MUT than the electrically conductive surface of the plate. Microwave energy at an operating frequency f is supplied from a signal source to the first coupling loop while microwave energy received at the second coupling loop is measured. The apparatus is capable of measuring the Q-factor of the dielectric resonator situated in the cavity existing between the electrically conductive surface of the plate and the MUT. Surface conductivity of the electrically conductive surface can be determined via interpolation using: 1) the measured Q-factor with the electrically conductive surface in place, and 2) the measured Q-factor when the MUT is replaced with reference standards having known surface conductivities.

Hearn, Chase P.↗

Quantum State Transfer between Heterogeneous 3D QPUs

We present detailed analyses and microwave simulations of a quantum interconnect architecture that couples two distinct three-dimensional quantum processing units (QPUs): (i) a two-cell superconducting radio-frequency (SRF) cavity coupled to multiple transmon qubits and (ii) a waveguide-based cavity hosting a planar circuit with transmons and resonators. The modules are linked via a low-loss superconducting coaxial cable, which serves as a quantum bus. Finite-element electromagnetic simulations are performed to optimize coupling strengths and mode frequencies for high-fidelity quantum state transfer between cavities. These simulation results provide a comprehensive blueprint for the experimental realization of a flexible quantum interconnect architecture, coupling heterogeneous QPUs.

Yaker, Joey [Fermilab]↗

Accelerated Weak Signal Search Using Mode Entanglement and State Swapping

Quantum fluctuations constitute the primary noise barrier limiting cavity-based axion-dark-matter searches. In an experiment designed to mimic a real axion search, we employ a quantum enhanced sensing technique to detect a synthetic axionlike microwave tone at an unknown frequency weakly coupled to a resonator, demonstrating a factor-of-5.6 acceleration relative to a quantum limited search for the same tone. This speed-up is achieved by dynamically coupling the resonator mode to a second (readout) mode with balanced swapping and two-mode squeezing interactions, which results in both visibility-bandwidth and peak-visibility increase. A small fractional imbalance between the two interaction rates yields further scan-rate enhancement and we demonstrate that an eightfold acceleration can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zr‐Porphyrin Metal–Organic Framework as nanoreactor for boosting the formation of hydrogen clathrates

Abstract We report the first experimental evidence for rapid formation of hydrogen clathrates under mild pressure and temperature conditions within the cavities of a zirconium‐metalloporphyrin framework, specifically PCN‐222. PCN‐222 has been selected for its 1D mesoporous channels, high water‐stability, and proper hydrophilic behavior. Firstly, we optimize a microwave (MW)‐assisted method for the synthesis of nanosized PCN‐222 particles with precise structure control (exceptional homogeneity in morphology and crystalline phase purity), taking advantage of MW in terms of rapid/homogeneous heating, time and energy savings, as well as potential scalability of the synthetic method. Second, we explore the relevance of the large mesoporous 1D open channels within the PCN‐222 to promote the nucleation and growth of confined hydrogen clathrates. Experimental results show that PCN‐222 drives the nucleation process at a lower pressure than the bulk system (1.35 kbar vs 2 kbar), with fast kinetics (minutes), using pure water, and with a nearly complete water‐to‐hydrate conversion. Unfortunately, PCN‐222 cannot withstand these high pressures, which lead to a significant alteration of the mesoporous structure while the microporous network remains mainly unchanged.

Carrillo‐Carrión, Carolina↗

Zr‐Porphyrin Metal–Organic Framework as nanoreactor for boosting the formation of hydrogen clathrates

Abstract We report the first experimental evidence for rapid formation of hydrogen clathrates under mild pressure and temperature conditions within the cavities of a zirconium‐metalloporphyrin framework, specifically PCN‐222. PCN‐222 has been selected for its 1D mesoporous channels, high water‐stability, and proper hydrophilic behavior. Firstly, we optimize a microwave (MW)‐assisted method for the synthesis of nanosized PCN‐222 particles with precise structure control (exceptional homogeneity in morphology and crystalline phase purity), taking advantage of MW in terms of rapid/homogeneous heating, time and energy savings, as well as potential scalability of the synthetic method. Second, we explore the relevance of the large mesoporous 1D open channels within the PCN‐222 to promote the nucleation and growth of confined hydrogen clathrates. Experimental results show that PCN‐222 drives the nucleation process at a lower pressure than the bulk system (1.35 kbar vs 2 kbar), with fast kinetics (minutes), using pure water, and with a nearly complete water‐to‐hydrate conversion. Unfortunately, PCN‐222 cannot withstand these high pressures, which lead to a significant alteration of the mesoporous structure while the microporous network remains mainly unchanged.

Carrillo‐Carrión, Carolina↗

Mechanical Purcell filters for microwave quantum machines

In circuit quantum electrodynamics, measuring the state of a superconducting qubit introduces a loss channel, which can enhance spontaneous emission through the Purcell effect, thus decreasing the qubit lifetime. This decay can be mitigated by performing the measurement through a Purcell filter, which strongly suppresses signal propagation at the qubit transition frequency. If the filter is also well-matched at the readout cavity frequency, it will protect the qubit from decoherence channels without sacrificing measurement bandwidth. In this work, we propose and analyze design for a mechanical Purcell filter, which we also fabricate and characterize at room temperature. The filter is composed of an array of nanomechanical resonators in thin-film lithium niobate, connected in a ladder topology, with series and parallel resonances arranged to produce a bandpass response. Their modest footprint, steep band edges, and lack of cross talk make these filters an appealing alternative to analogous electromagnetic versions currently used in microwave quantum machines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dielectric image-resonator multiplexer

A two, three or four channel multiplexer can be operated in the TE 01δ or HE 11δ modes, each channel of the multiplexer has one bandpass filter, with each filter usually having a plurality of cavities. One cavity of each filter is a common cavity with all of the other filters of the multiplexer. The common cavity contains one independent dielectric quarter-cut or half-cut image resonator for each filter representing a channel- of the multiplexer. Each resonator is mounted on a suitable support the common cavity provides a common junction and contains a loop coupling to couple electromagnetic energy between the various· channels. The multiplexer has at least one input and at least one output. Previous microwave multiplexers have a plurality of bandpass filters arranged on a coaxial manifold. With the multiplexer of the present invention, the manifold can be eliminated. Further, at the S-band or L-band, substantial weight and volume savings can be achieved using the multiplexer of the present invention without sacrificing performance. This can be very important for space applications.

Wai-Cheung Tang↗

3D superconducting radio-frequency resonators for quantum computing

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. In this presentation, I will review the current technology and progress towards the three dimensional SRF cavities to enhance the coherence time.

Dhakal, Pashupati↗

EM and beam dynamics modeling of CCL with CST Studio

The 800-MeV proton linac at LANSCE consists of a drift-tube linac, which brings the beam to 100 MeV, followed by a coupled-cavity linac (CCL). Each of 44 CCL modules contain multiple tanks, and it is fed by a single 805-MHz klystron. CCL tanks are multi-cell blocks of identical re-entrant sidecoupled cavities, which are followed by drifts with magnetic quadrupole doublets. Bridge couplers – special cavities displaced from the beam axis – electromagnetically couple CCL tanks over such drifts. We have developed 3D CST models of CCL tanks of the LANSCE linac. Their electromagnetic analysis is performed using MicroWave Studio. Beam dynamics is modeled with Particle Studio for bunch trains with realistic beam distributions using the CST calculated RF fields and quadrupole magnetic fields to determine the output beam parameters.

42 ENGINEERING↗

Search for Postinflationary QCD Axions with a Quantum-Limited Tunable Microwave Receiver

A search for cosmological axions has been performed by scanning a frequency region of 38 MHz centered at about 10.2 GHz, corresponding to an axion mass 𝑚 𝑎 ≃ 42 μ ⁢eV. The QUAX experimental apparatus, a haloscope comprised of a 1-liter volume tunable cavity immersed in an 8 T magnetic field and a quantum-limited detection chain, set limits on the axion-photon coupling at the 10 −14 GeV −1 level. As no signal candidate has been observed, viable hadronic axion models are ruled out in a currently preferred postinflationary region 𝑚 𝑎 > 40 μ ⁢eV.

Sardo Infirri, Giosue [INFN, Sezione di Padova; Un↗