Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Electron microscopy analyses and electrical properties of the layered Bi{sub 2}WO{sub 6} phase

The bismuth tungstate Bi{sub 2}WO{sub 6} was synthesized using a classical coprecipitation method followed by a calcination process at different temperatures. The samples were characterized by X-ray diffraction, simultaneous thermogravimetry and differential thermal analysis (TGA/DTA), scanning and transmission electron microscopy (SEM, TEM) analyses. The Rietveld analysis and electron diffraction clearly confirmed the Pca2{sub 1} non centrosymmetric space group previously proposed for this phase. The layers Bi{sub 2}O{sub 2}{sup 2+} and WO{sub 4}{sup 2−} have been directly evidenced from the HRTEM images. The electrical properties of Bi{sub 2}WO{sub 6} compacted pellets systems were determined from electrical impedance spectrometry (EIS) and direct current (DC) analyses, under air and argon, between 350 and 700 °C. The direct current analyses showed that the conduction observed from EIS analyses was mainly ionic in this temperature range, with a small electronic contribution. Electrical change above the transition temperature of 660 °C is observed under air and argon atmospheres. The strong conductivity increase observed under argon is interpreted in terms of formation of additional oxygen vacancies coupled with electron conduction. - Graphical abstract: High resolution transmission electron microscopy: inverse fast Fourier transform giving the layered structure of the Bi{sub 2}WO{sub 6} phase, with a representation of the cell dimensions (b and c vectors). The Bi{sub 2}O{sub 2}{sup 2+} and WO{sub 4}{sup 2−} sandwiches are visible in the IFFT image. - Highlights: • Using transmission electron microscopy, we visualize the layered structure of Bi{sub 2}WO{sub 6}. • Electrical analyses under argon gas show some increase in conductivity. • The phase transition at 660 °C is evidenced from electrical modification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A facile electron microscopy method for measuring precipitate volume fractions in AlCuMg alloys

Precipitate volume fraction is an important parameter to estimate the strength of precipitation-hardened metals. In this study, a facile method was applied to measure the precipitate volume fractions in an age-hardened AlCuMg alloy. In this method, the precipitate volume fraction values can be obtained by multiplying the volume precipitate number densities with the averaged precipitate volumes, which can be easily measured in scanning electron microscopy and transmission electron microscopy, respectively. Compared with the conventional method, in which the specimen thickness has to be measured in transmission electron microscopy, the method proposed in this study is more facile to perform. - Highlights: Black-Right-Pointing-Pointer We have proposed a facile method to measure precipitate volume fractions for precipitation-hardened metals. Black-Right-Pointing-Pointer This technique works well for the square-shaped {theta} Prime -phase nano-precipitates in 2xxx aluminum alloys. Black-Right-Pointing-Pointer Interesting is that the proposed method is easy for materials scientists and engineers to perform.

36 MATERIALS SCIENCE↗

Structural evolution and strain induced mixing in Cu–Co composites studied by transmission electron microscopy and atom probe tomography

A Cu–Co composite material is chosen as a model system to study structural evolution and phase formations during severe plastic deformation. The evolving microstructures as a function of the applied strain were characterized at the micro-, nano-, and atomic scale-levels by combining scanning electron microscopy and transmission electron microscopy including energy-filtered transmission electron microscopy and electron energy-loss spectroscopy. The amount of intermixing between the two phases at different strains was examined at the atomic scale using atom probe tomography as complimentary method. It is shown that Co particles are dissolved in the Cu matrix during severe plastic deformation to a remarkable extent and their size, number, and volume fraction were quantitatively determined during the deformation process. From the results, it can be concluded that supersaturated solid solutions up to 26 at.% Co in a fcc Cu–26 at.% Co alloy are obtained during deformation. However, the distribution of Co was found to be inhomogeneous even at the highest degree of investigated strain. - Highlights: • Structural evolution in a deformed Cu–Co composite is studied on all length scales. • Amount of intermixing is examined by atom-probe tomography. • Supersaturated solid solutions up to 26 at.% Co in Cu are observed.

36 MATERIALS SCIENCE↗

Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

36 MATERIALS SCIENCE↗

Friction force microscopy study of annealed diamond-like carbon film

In this paper we introduce mechanical and structural characteristics of diamond-like carbon (DLC) films which were prepared on silicon substrates by radio frequency (RF) plasma enhanced chemical vapor deposition (PECVD) method using methane (CH{sub 4}) and hydrogen (H{sub 2}) gas. The films were annealed at various temperatures ranging from 300 to 900 °C in steps of 200 °C using rapid thermal processor (RTP) in nitrogen ambient. Tribological properties of the DLC films were investigated by atomic force microscopy (AFM) in friction force microscopy (FFM) mode. The structural properties of the films were obtained by high resolution transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS). The wettability of the films was obtained using contact angle measurement. XPS analysis showed that the sp{sup 3} content is decreased from 75.2% to 24.1% while the sp{sup 2} content is increased from 24.8% to 75.9% when the temperature is changed from 300 to 900 °C. The contact angles of DLC films were higher than 70°. The FFM measurement results show that the highest friction coefficient value was achieved at 900 °C annealing temperature.

36 MATERIALS SCIENCE↗

Anti-contamination device for cryogenic soft X-ray diffraction microscopy

Cryogenic microscopy allows one to view frozen hydrated biological and soft matter specimens with good structural preservation and a high degree of stability against radiation damage. We describe a liquid nitrogen-cooled anti-contamination device for cryogenic X-ray diffraction microscopy. The anti-contaminator greatly reduces the buildup of ice layers on the specimen due to condensation of residual water vapor in the experimental vacuum chamber. We show by coherent X-ray diffraction measurements that this leads to fivefold reduction of background scattering, which is important for far-field X-ray diffraction microscopy of biological specimens.

36 MATERIALS SCIENCE↗

Electron microscopy techniques employed to explore mitochondrial defects in the developing rat brain following ketamine treatment

Ketamine, an FDA-approved N-methyl-D-aspartate (NMDA) receptor antagonist, is commonly used for general pediatric anesthesia. Accumulating evidence has indicated that prolonged exposure to ketamine induces widespread apoptotic cell death in the developing brains of experimental animals. Although mitochondria are known to play a pivotal role in cell death, little is known about the alterations in mitochondrial ultrastructure that occur during ketamine-induced neurotoxicity. The objective of this pilot study was to utilize classic and contemporary methods in electron microscopy to study the impact of ketamine on the structure of mitochondria in the developing rat brain. While transmission electron microscopy (TEM) was employed to comprehensively study mitochondrial inner membrane topology, serial block-face scanning electron microscopy (SBF-SEM) was used as a complementary technique to compare the overall mitochondrial morphology from a representative treated and untreated neuron. In this study, postnatal day 7 (PND-7) Sprague-Dawley rats were treated with ketamine or saline (6 subcutaneous injections × 20 mg/kg or 10 ml/kg, respectively, at 2-h intervals with a 6-h withdrawal period after the last injection, n=6 each group). Samples from the frontal cortex were harvested and analyzed using TEM or SBF-SEM. While classic TEM revealed that repeated ketamine exposure induces significant mitochondrial swelling in neurons, the newer technique of SBF-SEM confirmed the mitochondrial swelling in three dimensions (3D) and showed that ketamine exposure may also induce mitochondrial fission, which was not observable in the two dimensions (2D) of TEM. Furthermore, 3D statistical analysis of these reconstructed mitochondria appeared to show that ketamine-treated mitochondria had significantly larger volumes per unit surface area than mitochondria from the untreated neuron. The ultrastructural mitochondrial alterations demonstrated here by TEM and SBF-SEM support ketamine’s proposed mechanism of neurotoxicity in the developing rat brain.

60 APPLIED LIFE SCIENCES↗

Bayesian Active Learning for Scanning Probe Microscopy: From Gaussian Processes to Hypothesis Learning

Recent progress in machine learning methods and the emerging availability of programmable interfaces for scanning probe microscopes (SPMs) have propelled automated and autonomous microscopies to the forefront of attention of the scientific community. However, enabling automated microscopy requires the development of task-specific machine learning methods, understanding the interplay between physics discovery and machine learning, and fully defined discovery workflows. This, in turn, requires balancing the physical intuition and prior knowledge of the domain scientist with rewards that define experimental goals and machine learning algorithms that can translate these to specific experimental protocols. Here, we discuss the basic principles of Bayesian active learning and illustrate its applications for SPM. We progress from the Gaussian process as a simple data-driven method and Bayesian inference for physical models as an extension of physics-based functional fits to more complex deep kernel learning methods, structured Gaussian processes, and hypothesis learning. These frameworks allow for the use of prior data, the discovery of specific functionalities as encoded in spectral data, and exploration of physical laws manifesting during the experiment. Here, the discussed framework can be universally applied to all techniques combining imaging and spectroscopy, SPM methods, nanoindentation, electron microscopy and spectroscopy, and chemical imaging methods and can be particularly impactful for destructive or irreversible measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron microscopy analysis of crystalline silicon islands formed on screen-printed aluminum-doped p-type silicon surfaces

The origin of a not yet understood concentration peak, which is generally measured at the surface of aluminum-doped p{sup +} regions produced in a conventional screen-printing process is investigated. Our findings provide clear experimental evidence that the concentration peak is due to the microscopic structures formed at the silicon surface during the firing process. To characterize the microscopic nature of the islands (lateral dimensions of 1-3 {mu}m) and line networks of self-assembled nanostructures (lateral dimension of {<=}50 nm), transmission electron microscopy, scanning electron microscopy, scanning transmission electron microscopy, and energy dispersive x-ray analysis are combined. Aluminum inclusions are detected 50 nm below the surface of the islands and crystalline aluminum precipitates of {<=}7 nm in diameter are found within the bulk of the islands. In addition, aluminum inclusions (lateral dimension of {approx}30 nm) are found within the bulk of the self-assembled line networks.

36 MATERIALS SCIENCE↗

Soft x-ray holographic microscopy

We present a new x-ray microscopy technique based on Fourier transform holography (FTH), where the sample is separate from the optics part of the setup. The sample can be shifted with respect to the holography optics, thus large-scale or randomly distributed objects become accessible. As this extends FTH into a true microscopy technique, we call it x-ray holographic microscopy (XHM). FTH allows nanoscale imaging without the need for nanometer-size beams. Simple Fourier transform yields an unambiguous image reconstruction. We demonstrate XHM by studying the magnetic domain evolution of a Co/Pt multilayer film as function of locally varied iron overlayer thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electromechanical response of amorphous LaAlO{sub 3} thin film probed by scanning probe microscopies

The electromechanical response of a 3 nm thick amorphous LaAlO{sub 3} layer obtained by molecular beam epitaxy has been studied using scanning probe microscopies. Although this kind of sample is not ferroelectric due to its amorphous nature, the resulting images are identical to what is generally obtained on truly ferroelectric samples probed by piezoresponse force microscopy: domains of apparently opposite polarisation are detected, and perfect, square shaped hysteresis loops are recorded. Moreover, written patterns are stable within 72 h. We discuss in the general case the possible origins of this behaviour in terms of charge injection, ionic conduction and motion of oxygen vacancies. In the case presented in this paper, since the writing process has been conducted with applied voltages lower than the injection threshold measured by conductive atomic force Microscopy, allowing to withdraw the hypothesis of charge injection in the sample, we propose that a bistable distribution of oxygen vacancies is responsible for this contrast.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three axis vector magnet set-up for cryogenic scanning probe microscopy

We describe a three axis vector magnet system for cryogenic scanning probe microscopy measurements. We discuss the magnet support system and the power supply, consisting of a compact three way 100 A current source. We obtain tilted magnetic fields in all directions with maximum value of 5T along z-axis and of 1.2T for XY-plane magnetic fields. We describe a scanning tunneling microscopy-spectroscopy (STM-STS) set-up, operating in a dilution refrigerator, which includes a new high voltage ultralow noise piezodrive electronics and discuss the noise level due to vibrations. STM images and STS maps show atomic resolution and the tilted vortex lattice at 150 mK in the superconductor β-Bi{sub 2}Pd. We observe a strongly elongated hexagonal lattice, which corresponds to the projection of the tilted hexagonal vortex lattice on the surface. We also discuss Magnetic Force Microscopy images in a variable temperature insert.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of individual molecular adsorption geometries by atomic force microscopy: Cu-TCPP on rutile TiO{sub 2} (110)

Functionalized materials consisting of inorganic substrates with organic adsorbates play an increasing role in emerging technologies like molecular electronics or hybrid photovoltaics. For such applications, the adsorption geometry of the molecules under operating conditions, e.g., ambient temperature, is crucial because it influences the electronic properties of the interface, which in turn determine the device performance. So far detailed experimental characterization of adsorbates at room temperature has mainly been done using a combination of complementary methods like photoelectron spectroscopy together with scanning tunneling microscopy. However, this approach is limited to ensembles of adsorbates. In this paper, we show that the characterization of individual molecules at room temperature, comprising the determination of the adsorption configuration and the electrostatic interaction with the surface, can be achieved experimentally by atomic force microscopy (AFM) and Kelvin probe force microscopy (KPFM). We demonstrate this by identifying two different adsorption configurations of isolated copper(II) meso-tetra (4-carboxyphenyl) porphyrin (Cu-TCPP) on rutile TiO{sub 2} (110) in ultra-high vacuum. The local contact potential difference measured by KPFM indicates an interfacial dipole due to electron transfer from the Cu-TCPP to the TiO{sub 2}. The experimental results are verified by state-of-the-art first principles calculations. We note that the improvement of the AFM resolution, achieved in this work, is crucial for such accurate calculations. Therefore, high resolution AFM at room temperature is promising for significantly promoting the understanding of molecular adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving amorphous solid-liquid interfaces by atomic force microscopy

Recent advancements in liquid atomic force microscopy make it an ideal technique for probing the structure of solid-liquid interfaces. Here, we present a structural study of a two-dimensional amorphous silica bilayer immersed in an aqueous solution utilizing liquid atomic force microscopy with sub-nanometer resolution. Structures show good agreement with atomically resolved ultra-high vacuum scanning tunneling microscopy images obtained on the same sample system, owing to the structural stability of the silica bilayer and the imaging clarity from the two-dimensional sample system. Pair distance histograms of ring center positions are utilized to develop quantitative metrics for structural comparison, and the physical origin of pair distance histogram peaks is addressed by direct assessment of real space structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mind the gap: Bridging the divide between AI aspirations and the reality of autonomous microscopy

What does materials science look like in the “Age of Artificial Intelligence?” Each material’s domain—synthesis, characterization, and modeling—has a different answer to this question, motivated by unique challenges and constraints. This work focuses on the tremendous potential of autonomous characterization within electron microscopy. We present our recent advancements in developing domain-aware, multimodal models for microscopy analysis capable of describing complex atomic systems. We then address the critical gap between the theoretical promise of autonomous microscopy and its current practical limitations, showcasing recent successes while highlighting the necessary developments to achieve robust, real-world autonomy.

2D materials↗

Electron microscopy methods in studies of cultural heritage sites

The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transmission Electron Microscopy Study of Eu-Doped Y2O3 Nanosheets and Nanotubes

A hydrothermal method was used to synthesize high-purity Eu-doped Y{sub 2}O{sub 3} nanosheets and nanotubes with an approximate molar ratio of (0.1):(1.0) for Eu:Y. High-resolution transmission electron microscopy, energy dispersive X-ray spectroscopy analysis and synchrotron X-ray diffraction were used to characterize these nanomaterials. A body-centered cubic structure was confirmed for the nanotubes. The lattice parameter of Eu-doped Y{sub 2}O{sub 3} nanotubes were 0.12% larger as compared to that of pure Y{sub 2}O{sub 3} which was attributed to the larger ionic radius of Eu{sup 3+} (0.947 {angstrom}) than that of Y{sup 3+} (0.900 {angstrom}). The nanosheets had a similar structure. Nanosheets of approximate dimensions 600 to 800 nm length and width were obtained using a slightly lower pH value, and they were highly textured. The high resolution transmission electron microscopy images showed that the nanotubes are fully crystalline. The nanotubes were typically 1.5-3 {micro}m in length and 50-200 nm in diameter. Using a pH value of approximately 10, stable nanotubes were obtained. It is anticipated that nanosheets might have rolled to form more stable nanotubes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Engineering solar cells based on correlative X-ray microscopy

In situ and operando measurement techniques combined with nanoscale resolution have proven invaluable in multiple fields of study. We argue that evaluating device performance as well as material behavior by correlative X-ray microscopy with <100 nm resolution can radically change the approach for optimizing absorbers, interfaces and full devices in solar cell research. Here, we thoroughly discuss the measurement technique of X-ray beam induced current and point out fundamental differences between measurements of wafer-based silicon and thin-film solar cells. Based on reports of the last years, we showcase the potential that X-ray microscopy measurements have in combination with in situ and operando approaches throughout the solar cell lifecycle: from the growth of individual layers to the performance under operating conditions and degradation mechanisms. Enabled by new developments in synchrotron beamlines, the combination of high spatial resolution with high brilliance and a safe working distance allows for the insertion of measurement equipment that can pave the way for a new class of experiments. When applied to photovoltaics research, we highlight today’s opportunities and challenges in the field of nanoscale X-ray microscopy, and give an outlook on future developments.

36 MATERIALS SCIENCE↗