Nb 3 Sn Superconducting Cavities by Bronze Routes for Accelerator Stewardship

This project explored the challenges of making Nb 3 Sn superconducting radio-frequency (SRF) cavities by bronze routes. The SRF research community has prioritized Nb 3 Sn for many reasons, including the possibility to operate linacs for stewardship applications in continuous-wave mode with compact cryogenic systems. Existing Nb 3 Sn approaches use a cavity body made of niobium and apply tin to the polished cavity interior, a starting point that contains the main costs of present niobium cavity technology. Further complexity is then added because a high vacuum and temperature >1100 °C must be used to prevent formation of undesirable Nb-Sn phases, de-gas interstitial contaminants, and maintain the high purity of the Nb body. The project sought a more cost-effective solution for the same performance opportunities by exploiting the Cu-Sn-Nb diffusion reactions used to make Nb 3 Sn superconducting wires for magnets, which can be carried out at ~700 °C and are compatible with much cheaper copper cavity bodies. The project also sought understanding of the materials science and factors that affect superconducting properties. The project has impacted SRF cavity technology by demonstrating feasibility of alternative routes that enable compact, high-power electron accelerators for energy, security, environment, medical, and commercial applications.

43 PARTICLE ACCELERATORS↗

Production and Purification of Terbium-155 Using Natural Gadolinium Targets

Terbium-155 (t 1/2 = 5.32 days) is one of four medically relevant radioisotopes of terbium. It is of interest to the field as a suitable diagnostic counterpart for therapeutic radiolanthanides, as its decay scheme includes γ-rays that are suitable for single photon emission computed tomography (SPECT) imaging. Additionally, 155 Tb has an Auger electron (AE) yield that is viable for AE therapy. There are several direct and indirect production routes that can produce 155 Tb. Two possible direct routes include proton irradiation on gadolinium targets via 155 Gd(p,n) 155 Tb and 156 Gd(p,2n) 155 Tb. The 155 Gd(p,n) 155 Tb reaction is accessible at incident proton beam energies of ∼10 MeV, whereas the 156 Gd(p,2n) 155 Tb nuclear reaction requires ∼18 MeV. This study aims to investigate the production of 155 Tb from natGd through the nat Gd(p,x) nuclear reaction, wherein both (p,n) and (p,2n) reactions were leveraged, and the purification using a three-column ion chromatography method. Using this system, recoveries of radioterbium of up to 97% were achieved in addition to high recoveries of the Gd target material, illustrating the suitability of this technique for enriched targets.

36 MATERIALS SCIENCE↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Computational Thermal Hydraulics of a High-Performance Low-Enriched-Uranium Annular Target for HFIR Irradiation

Molybdenum-99 has historically been generated via isolation from fissioned highly enriched uranium (HEU) targets. Here, this isotope is in high demand due to its daily use across the world in radiopharmaceutical medical procedures. The primary objective of this work was to design and analyze an experimental target assembly containing one low-enriched-uranium (LEU) annular target for irradiation at the High Flux Isotope Reactor (HFIR). Efforts included incorporating spatially dependent energy sources from neutron and gamma interactions, quantifying thermal contact conductance at material interfaces, performing grid-independent studies, comparing turbulence models, and simulating various steady-state and transient scenarios relevant for irradiation qualification and eventual insertion. These models provide velocity, pressure, and temperature distributions in both space and time. Such results enable the selection of an appropriate irradiation location, fission rate density, and flow-limiting orifice size and demonstrate compliance with HFIR safety requirements such that insertion into the reactor can be approved. This analysis shows that across all scenarios, wetted surface temperatures remain below the coolant saturation temperature with no net vapor formation in the coolant. In every scenario, all components stay below 30% of the aluminum 6061 melting temperature. Computational fluid dynamics and system-level models predict peak target temperatures that agree within 4%, though the predicted axial location of the peak differs by about 10% of the heated length due to differences in flow development length. These results de-risk the irradiation of LEU (annular targets) and strengthen a domestic, HEU-independent 99 Mo supply by providing important fuel performance data to form the foundation for a robust licensing basis.

Molybdenum-99↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

Symptoms and Systemic Drug Reactions in Persons Receiving Weekly Rifapentine Plus Isoniazid (3HP) Treatment for Latent Tuberculosis Infection

Abstract Background Three months of weekly rifapentine plus isoniazid (3HP) therapy for latent tuberculosis infection (LTBI) is recommended worldwide. The development of symptoms and systemic drug reactions (SDRs) on 3HP have not been fully characterized. We aimed to determine the patterns of symptom development and identify SDRs and associated factors in patients taking 3HP. Methods We analyzed symptoms data in participants receiving 3HP in the Tuberculosis Trials Consortium's iAdhere study (Study 33). We examined the patterns of symptom reporting across participants from baseline and 4 monthly visits. Bivariate analyses and multivariable regression models were used to identify factors associated with SDRs. Risk ratios (RRs) and 95% confidence intervals (CIs) were calculated. Results Among 1002 participants receiving 3HP, 768 (77%) reported at least 1 symptom; 97% of these symptoms were grade 1 (79%) or grade 2 (18%). Most symptoms developed in the first month and resolved. A total of 111 (11%) participants had symptoms that met criteria for SDRs; however, 53 (48%) of these participants completed therapy. Factors associated with SDRs and discontinuation included female sex (RR: 2.05; 95% CI: 1.19–3.54), age ≥45 years (RR: 1.99; 95% CI: 1.19–3.31), and use of concomitant medications (RR: 2.26; 95% CI: 1.15–4.42). Conclusions Although most patients receiving 3HP reported symptoms, most were mild, occurred early, and resolved without stopping treatment. Among patients experiencing SDRs, nearly half were able to complete therapy. Patient and provider education should focus on differentiating severe reactions where 3HP should be stopped from minor symptoms that will resolve. Clinical Trials Registration. NCT01582711.

Immunology↗

PRIMED for the Future: Purposing Raw Intake for Machine Learning-Enabled Detection

The COVID-19 pandemic demonstrated how a novel, elusive, and diffuse biological threat can engender uncertainty and misinformation, and it underscored the need for flexible analytical modalities agnostic to the identity of biological material. Yet even before the pandemic recognition of the limitations of the current, list-based approach, which focuses on known pathogens and biotoxins, and of the importance of agent-agnostic biodetection, was growing within the biosecurity community. In a 2018 report on “Biodefense in the Age of Synthetic Biology,” for example, the National Academy of Sciences stated that “an overreliance on the Select Agent List is a systematic weakness affecting many aspects of the United States’ current biodefense mitigation capability." More recently, a group of biodefense researchers proposed the identification and adoption of “bioagent-agnostic signatures (BASs)” as a way of detecting and characterizing not only existing agents but also novel ones, an approach they believe will “enable a more flexible and resilient biodefense posture." Indeed, the future of biodetection requires us to begin developing novel analytics that can identify anomalies and/or characteristics that indicate a potential threat, whether known or unknown, without looking for a specific signature that has been identified previously. To assess potential threats more rapidly, it is critical to develop agnostic artificial intelligence (AI)/machine learning (ML) systems that can be employed for real-time assessment of the nature and source of a perturbation. Such systems should be multiscale and multi-dimensional, integrating sensor data from a range of biological, chemical, and physical application spaces. Emerging deep learning (DL) models demonstrate exceptional promise for identification of discriminatory features within multi-dimensional datasets. DL models have the capacity to recognize and encode highly complex patterns in a wide range of input data modalities, including images, text, and biological/chemical/physical spectra. As such, they can execute a wide range of assessments and determinations that have traditionally required a human operator.

59 BASIC BIOLOGICAL SCIENCES↗

Development of an accelerator-based neutron source to prototype Mo-99 production, part I: A liquid LBE windowless target

In this article, Molybdenum-99 (Mo-99)’s decay product, technetium-99 (Tc-99 m), is one of the most critical isotopes for medical diagnostics. To provide U.S. domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. This study discusses the development of the accelerator-based neutron source. The high-energy electrons from the accelerator irradiate a liquid lead-bismuth eutectic (LBE) target to produce neutrons. Part I of this work focuses on numerical and experimental analysis towards the development of a liquid LBE windowless target. Unlike the existing windowless targets in literature, the current design creates a vertical free surface for a beam to irradiate. First, a hydrodynamic analysis of the LBE windowless target is performed. Simplified analytical calculations are assisted by 2D computational fluid dynamics (CFD) simulations to design the target, with the focus on eliminating recirculation zones and avoiding cavitation. With the optimized geometry, the experimental study is performed to investigate the flow hydrodynamics using liquid LBE. The experiments (1) compare pressure drop in the system to correlation predictions; (2) visualize the free surface liquid LBE flow from the beam view; (3) validate the LBE flow profile using temperature sensitive paint from the side view; and (4) validate the liquid LBE film thickness using gamma densitometer measurements. Second, the power handling capability of the designed windowless target is investigated. The divider plate in the current design is susceptible to overheating due to the thin LBE film in front. As LBE erosion and corrosion is likely to occur at an LBE velocity of 2.0 m/s and temperature above 500 °C, a power limit of 10 kW of beam power was established to prevent this corrosion from occurring, which is calculated by a Nusselt number correlation. The divider plate surface temperature at 10 kW agrees well with the 3D CFD simulation results. Part I demonstrates the fundamental physics in liquid LBE windowless target design and associated testing. A companion paper, Part II will demonstrate how to couple this windowless target into the Mo-99 production system, including an accelerator system operating under an ultra-high vacuum and the UTA cooled by water at room temperature.

43 PARTICLE ACCELERATORS↗

Cytogenetic follow-up studies on humans with internal and external exposure to ionizing radiation

Cells exposed to ionizing radiation have a wide spectrum of DNA lesions that include DNA single-strand breaks, DNA double-strand breaks (DSBs), oxidative base damage and DNA-protein crosslinks. Among them, DSB is the most critical lesion, which when mis-repaired leads to unstable and stable chromosome aberrations. Currently, chromosome aberration analysis is the preferred method for biological monitoring of radiation-exposed humans. Here, stable chromosome aberrations, such as inversions and balanced translocations, persist in the peripheral blood lymphocytes of radiation-exposed humans for several years and, therefore, are potentially useful tools to prognosticate the health risks of radiation exposure, particularly in the hematopoietic system. In this review, we summarize the cytogenetic follow-up studies performed by REAC/TS (Radiation Emergency Assistance Center/Training site, Oak Ridge, USA) on humans exposed to internal and external radiation. In the light of our observations as well as the data existing in the literature, this review attempts to highlight the importance of follow-up studies for predicting the extent of genomic instability and its impact on delayed health risks in radiation-exposed victims.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design Optimization of A generic Fissile Solution for Mo99 production using Electron Beam-based Neutron Generator using MCNP+CFD

Molybdenum-99 ( 99 Mo) is a medical isotope used in 80% of all medical imaging procedures today. However, 99 Mo is not directly administered to patients for imaging; its decay product, technetium-99m ( 99 mTc), is a metastable isotope with a half-life of ~6 hours. Such a short half-life does not allow for production, separation, and application to a patient before decaying further. Therefore, the solution is to produce the precursor to 99 mTc, 99 Mo. 99 Mo has a half-life of 66 hours, long enough to produce the material and send it to the desired location before it fully decays. Under National Nuclear Security Administration’s (NNSA) highly enriched uranium (HEU) minimization mission, the Material Management and Minimization (M3) office leads the Molybdenum-99 (Mo-99) program. A major goal of the Mo-99 program is to develop methods of producing 99 Mo using low enriched uranium (LEU) opposed to the traditionally used HEU domestically in the U.S. Internationally, LEU is the new standard for use in research reactors and isotope production facility. In this study, we introduce a generic fissile solution system for 99 Mo production facility meeting the design requirement of 1) LEU usage as fissile material and 2) subcritical fissile system coupled with a horizontal electron beam (E-beam) accelerator. The focus of this research is to optimize a fissile solution configuration for maximum 99 Mo production yield using MCNP model, and ultimately implement the optimized design with computational fluid dynamics (CFD) model to understand thermal hydraulic behavior and solution convection characteristic. The report consists of two parts: 1) isotope yield calculation and criticality analysis with a wide range of parametric test matrix, and 2) thermal hydraulic analysis for solution mixing and cooling assessment.

60 APPLIED LIFE SCIENCES↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Platform for Ultra-Fast Proton Probing of Matter in Extreme Conditions

Recent developments in ultrashort and intense laser systems have enabled the generation of short and brilliant proton sources, which are valuable for studying plasmas under extreme conditions in high-energy-density physics. However, developing sensors for the energy selection, focusing, transport, and detection of these sources remains challenging. This work presents a novel and simple design for an isochronous magnetic selector capable of angular and energy selection of proton sources, significantly reducing temporal spread compared to the current state of the art. The isochronous selector separates the beam based on ion energy, making it a potential component in new energy spectrum sensors for ions. Analytical estimations and Monte Carlo simulations validate the proposed configuration. Due to its low temporal spread, this selector is also useful for studying extreme states of matter, such as proton stopping power in warm dense matter, where short plasma stagnation time (<100 ps) is a critical factor. The proposed selector can also be employed at higher proton energies, achieving final time spreads of a few picoseconds. This has important implications for sensing technologies in the study of coherent energy deposition in biology and medical physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile allelic replacement and self-excising integrative vectors for plasmid genome mutation and complementation

ABSTRACT The ability to better understand the function of proteins expressed by bacteria has typically relied upon the development of genetic mutant strains. This approach has been especially challenging for plasmid-encoded genes, as most of the previously described allelic replacement vectors are inefficient for plasmid genome mutation as they either rely on plasmid-derived counterselection toxins or depend on other strategies suchsacB,tetA, andrpsLwhich have been proven to be less efficient for mutant selection. Integrative vectors lack chromophore indicators, thus requiring laborious screening or excision of the vector’s backbone relies on the introduction of a flippase (FLP)-expressing plasmid. The allelic replacement vector, designated here as pDG1, expresses an X-Gal hydrolyzing enzyme (BgaB) that can be used for blue/white screening allowing identification of colonies that integrated and successfully removed the mutagenesis plasmid without a bias for those still carrying it. pDG1 was further improved by including the rhamnose-inducible Tse2 toxin as a potent counterselection system. The efficacy of pDG1 was validated by deleting portions of the plasmid-encoded VirB4/D4 type IV secretion system and aerobactin-synthesizing operons inSalmonella enterica. The integrative vectors, which contain an ΦC31attPsite and genes encoding ΦC31 integrase (int), can seamlessly integrate to target ΦC31attBonSalmonellaplasmids or chromosome. These vectors were improved by insertingbgaBand FLP-encoding genes so that, following integration, most of the vector’s backbone encompassingint,bgaB, and FLP genes can be excised by FLP, without the need for another FLP-expressing vector, creating white colonies carrying a stably integrated target gene. As such, we were able to integrate a 9.3-kb DNA fragment toSalmonellachromosome and flipped out most of the integrated vector in one step, leaving the target fragment in the chromosome. IMPORTANCE In spite of the dissemination of multidrug-resistant plasmids among Gram-negative pathogens, including those carrying virulence genes, vector tools for studying plasmid-born genes are lacking. The allelic replacement vectors can be used to generate plasmid or chromosomal mutations including markless point mutations. This is the first report describing a self-excising integrative vector that can be used as a stable single-copy complementing tool to study medically important pathogens includingin vivostudies without the need for antibiotic selection. Overall, our newly developed vectors can be applied for the assessment of the function of plasmid-encoded genes by specifically creating mutations, moving large operons between plasmids and to/from the chromosome, and complementing phenotypes associated with gene mutation. Furthermore, the vectors express chromophores for the detection of target gene modification or colony isolation, avoiding time-consuming screening procedures.

Microbiology↗

Antimicrobial Peptide Mimics for Clinical Use: Does Size Matter?

The search for efficient antimicrobial therapies that can alleviate suffering caused by infections from resistant bacteria is more urgent than ever before. Infections caused by multi-resistant pathogens represent a significant and increasing burden to healthcare and society and researcher are investigating new classes of bioactive compounds to slow down this development. Antimicrobial peptides from the innate immune system represent one promising class that offers a potential solution to the antibiotic resistance problem due to their mode of action on the microbial membranes. However, challenges associated with pharmacokinetics, bioavailability and off-target toxicity are slowing down the advancement and use of innate defensive peptides. Improving the therapeutic properties of these peptides is a strategy for reducing the clinical limitations and synthetic mimics of antimicrobial peptides are emerging as a promising class of molecules for a variety of antimicrobial applications. These compounds can be made significantly shorter while maintaining, or even improving antimicrobial properties, and several downsized synthetic mimics are now in clinical development for a range of infectious diseases. A variety of strategies can be employed to prepare these small compounds and this review describes the different compounds developed to date by adhering to a minimum pharmacophore based on an amphiphilic balance between cationic charge and hydrophobicity. These compounds can be made as small as dipeptides, circumventing the need for large compounds with elaborate three-dimensional structures to generate simplified and potent antimicrobial mimics for a range of medical applications. This review highlights key and recent development in the field of small antimicrobial peptide mimics as a promising class of antimicrobials, illustrating just how small you can go.

60 APPLIED LIFE SCIENCES↗

Viral Dynamic Models During COVID‐19: Are We Ready for the Next Pandemic?

Mathematical models have been used for about 30 years to improve our understanding of virus-host interaction, in particular during chronic infections. During the COVID-19 pandemic, these models have been used to provide insights into the natural history of acute SARS-CoV-2 infection, optimize antiviral treatment strategies, understand factors associated with transmission, and optimize surveillance systems. The impact of modeling has been accelerated by the availability of unprecedented multidimensional immune data from animal and human systems, which enhanced partnerships between experimentalists and theorists and led to exciting new modeling and statistical developments. In this mini review, we examine the lessons learned from the COVID-19 pandemic and discuss the main insights provided by mathematical models of viral dynamics at the different stages of the outbreak. Although we focus on respiratory infection, we also consider the new areas for development in anticipation of future acute infections from new or reemerging pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

In situ tumor model for longitudinal in silico imaging trials

Abstract Objective.In this article, we introduce a computational model for simulating the growth of breast cancer lesions accounting for the stiffness of surrounding anatomical structures.Approach.In our model, ligaments are classified as the most rigid structures while the softer parts of the breast are occupied by fat and glandular tissues As a result of these variations in tissue elasticity, the rapidly proliferating tumor cells are met with differential resistance. It is found that these cells are likely to circumvent stiffer terrains such as ligaments, instead electing to proliferate preferentially within the more yielding confines of the breast’s soft topography. By manipulating the interstitial tumor pressure in direct proportion to the elastic constants of the tissues surrounding the tumor, this model thus creates the potential for realizing a database of unique lesion morphology sculpted by the distinctive topography of each local anatomical infrastructure. We modeled the growth of simulated lesions within volumes extracted from fatty breast models, developed by Graffet alwith a resolution of 50μm generated with the open-source and readily available Virtual Imaging Clinical Trials for Regulatory Evaluation (VICTRE) imaging pipeline. To visualize and validate the realism of the lesion models, we leveraged the imaging component of the VICTRE pipeline, which replicates the siemens mammomat inspiration mammography system in a digital format. This system was instrumental in generating digital mammogram (DM) images for each breast model containing the simulated lesions.Results.By utilizing the DM images, we were able to effectively illustrate the imaging characteristics of the lesions as they integrated with the anatomical backgrounds. Our research also involved a reader study that compared 25 simulated DM regions of interest (ROIs) with inserted lesions from our models with DM ROIs from the DDSM dataset containing real manifestations of breast cancer. In general the simulation time for the lesions was approximately 2.5 hours, but it varied depending on the lesion’s local environment.Significance.The lesion growth model will facilitate and enhance longitudinal in silico trials investigating the progression of breast cancer.

Engineering↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.