Lensless Image Scanner

Image scanner uses moving and stationary parallel slits to produce pictures of visible, infrared, X-ray microwave, or acoustic sources. No lenses or mirrors required. Single detector views all parts of image simultaneously rather than raster making relatively-short exposure times possible. Potential applications of system include medical x-ray imaging.

Schindler, R. A.↗

Magnetic refrigeration for low-temperature applications

The application of refrigeration at low temperatures ranging from production of liquid helium for medical imaging systems to cooling of infrared sensors on surveillance satellites is discussed. Cooling below about 15 K with regenerative refrigerators is difficult because of the decreasing thermal mass of the regenerator compared to that of the working material. In order to overcome this difficulty with helium gas as the working material, a heat exchanger plus a Joule-Thomson or other exponder is used. Regenerative magnetic refrigerators with magnetic solids as the working material have the same regenerator problem as gas refrigerators. This problem provides motivation for the development of nonregenerative magnetic refrigerators that span approximately 1 K to approximately 0 K. Particular emphasis is placed on high reliability and high efficiency. Calculations indicate considerable promise in this area. The principles, the potential, the problems, and the progress towards development of successful 4 to 20 K magnetic refrigerators are discussed.

Barclay, J. A.↗

Lunar and Mars missions - Challenges for advanced life support

The development of a suite of scenarios is a prerequisite to the studies that will enable an informed decision by the United States on a program to meet the recently announced space policy goal to expand human presence beyond earth orbit. NASA's Office of Exploration is currently studying a range of initiative options that would extend the sphere of human activity in space to Mars and include permanent bases or outposts on the moon and on Mars. This paper describes the evolutionary lunar base and the Mars expedition scenarios in some detail so that an evaluation can be made from the point of view of human support and opportunities. Alternative approaches in the development of lunar outposts are outlined along with Mars expeditionary scenarios. Human environmental issues are discussed, including: closed loop life support systems; EVA systems; mobility systems; and medical support, physiological deconditioning, and psychological effects associated with long-duration missions.

Duke, Michael B.↗

Evaluation of cardiopulmonary resuscitation techniques in microgravity

Cardiopulmonary resuscitation (CPR) techniques were investigated in microgravity with specific application to planned medical capabilities for Space Station Freedom (SSF). A KC-135 parabolic flight test was performed with the goal of evaluating and quantifying the efficacy of different types of microgravity CPR techniques. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. Three experiments were involved chosen for their clinical background, certification, and practical experience in prior KC-135 parabolic flight. The CPR evaluation was performed using a standard training mannequin (recording resusci-Annie) which was used in practice prior to the actual flight. Aboard the KC-135, the prototype medical restraint system (MRS) for the SSF Health Maintenance Facility (HMF) was used for part of the study. Standard patient and crew restraints were used for interface with the MRS. During the portion of study where CPR was performed without MRS, a set of straps for crew restraint similar to those currently employed for the Space Shuttle program were used. The entire study was recorded via still camera and video.

Billica, Roger↗

Fluid handling 2: Surgical applications

The methods proposed for managing fluids and particulate debris during minor surgery on Space Station Freedom (SSF) were investigated and demonstrated. A KC-135 parabolic flight test was performed, in which the flight followed the standard 40 parabola profile with 20 to 25 seconds in near-zero gravity in each parabola. The equipment (suction and laminar flow device) was evaluated. While this equipment performed satisfactorily previously in the dental simulation, the purpose of the current flight was to reconfigure the equipment in support of a minor surgical situation in order to evaluate its efficacy and establish clear requirements for the actual flight hardware. To accomplish the study the Health Maintenance Facility medical restraint system was deployed as for surgical use and mannequin suture arm was restrained to its surface. The surgical area was established as for performing minor surgery with standard tray and suture instruments employed.

Billica, Roger↗

Medical concerns for exploration-class missions

The Space Exploration initiative will challenge life scientists with a diverse set of crew medical risks. The varied sources of this cumulative risk are identified and briefly discussed in terms of risk assessment and preliminary plans for risk management. The roles of Space Station Freedom and other flight programs are discussed in the context of exploration medical objectives. The significant differences between Space Station era (second generation) and exploration medical support systems (third generation) are reviewed.

Stewart, Donald F.↗

US-USSR telemedicine consultation spacebridge to Armenia and Ufa

The Final Report on the U.S.-U.S.S.R. Telemedicine Consultation Spacebride to Armenia and Ufa is presented. The goal of this activity was to provide expert medical consultation to the Armenian medical personnel in the areas of plastic and reconstructive surgery, physical and psychological rehabilitation, public health, and epidemiology following the devastating earthquake in Dec. 1988. The U.S. and U.S.S.R. implementation teams developed new standards for medical information transmittal as well as protocols and schedules on how to conduct medical consultations. The consultations were provided to the Republic Diagnostic Center in Yerevan, U.S.S.R. by four U.S. medical centers: University of Utah/LDS Hospital, University of Texas, Maryland Institute for Emergency Medical Service Systems, and Uniformed Services University of the Health Sciences.

Source record↗

Software Design Improvements: Software Benefits and Limitations - Part 1

Computer hardware and associated software have been used for many years to process accounting information, to analyze test data and to perform engineering analysis. Now computers and software also control everything from automobiles to washing machines and the number and type of applications are growing at an exponential rate. The size of individual program has shown similar growth. Furthermore, software and hardware are used to monitor and/or control potentially dangerous products and safety-critical systems. These uses include everything from airplanes and braking systems to medical devices and nuclear plants. The question is: how can this hardware and software be made more reliable? Also, how can software quality be improved? What methodology needs to be provided on large and small software products to improve the design and how can software be verified?

Lalli, Vincent R.↗

Breaking the Wavelength Barrier

Under an SBIR (Small Business Innovative Research) contract with Goddard Space Flight Center, Focused Research, Inc. and New Focus, Inc., developed a single mode tunable diode laser from 1.9 to 4.0 microns. As an offshoot from this work, they were able to introduce a 2.0 micron diode laser into their commercial product line. These lasers are useful in trace gas detection, environmental monitoring, seeding of lidar systems, and medical diagnostic experiments.

Source record↗

Control Software

Real-Time Innovations, Inc. (RTI) collaborated with Ames Research Center, the Jet Propulsion Laboratory and Stanford University to leverage NASA research to produce ControlShell software. RTI is the first "graduate" of Ames Research Center's Technology Commercialization Center. The ControlShell system was used extensively on a cooperative project to enhance the capabilities of a Russian-built Marsokhod rover being evaluated for eventual flight to Mars. RTI's ControlShell is complex, real-time command and control software, capable of processing information and controlling mechanical devices. One ControlShell tool is StethoScope. As a real-time data collection and display tool, StethoScope allows a user to see how a program is running without changing its execution. RTI has successfully applied its software savvy in other arenas, such as telecommunications, networking, video editing, semiconductor manufacturing, automobile systems, and medical imaging.

Source record↗

New Help for MS Patients

The Mark VII MicroClimate Medical Personal Cooling system enables multiple sclerosis' victims, as well as cerebral palsy, spinabifida patients and others to lower their body temperatures. Although this is not a cure, cooling can produce a dramatic improvement in symptoms. The Multiple Sclerosis Association of America has placed cool suits in MS research care centers. This technology originated in the need for cooling systems in spa@esuits. "Cool Suits" are now used by hazardous materials workers, armored vehicle crews, firefighters and crop dusters. A surgical personal cooling system has also been developed for medical personnel working in hot operating room environments.

Source record↗

Better Physician's 'Black Bags'

The "black bag" is outgrowth of astronaut monitoring technology from NASA's Johnson Space Center. Technically known as the portable medical status system, a highly advanced physician's "black bag" weighs less than 30 pounds, yet contains equipment for monitoring and recording vital signs, electrocardiograms, and electroencephalograms. Liquid crystal displays are used to present 15 digits of data simultaneously for long periods of time without excessive use of battery power. Single printed circuit card contains all circuitry required to measure and display vital signs such as heart and respiration rate, temperature, and blood pressure.

Source record↗

Keeping a Beat on the Heart

Feel the relief of a patient suffering from heart arrhythmia, who is able to return home while having her heart monitored by health professionals 24 hours a day, without the fear that she will miss an important indicator and suffer a fatal heart attack - using technology originally developed to conduct experiments on the Space Shuttle. Approximately 400,000 Americans die every year from sudden heart attacks . Medical research revealed that patterns of electrical activity in the heart can act as predictors of these lethal cardiac events known as arrhythmias. Fortunately, certain arrhythmias such as ventricular fibrillation (loss of regular heartbeat and subsequent loss of function) and ventricular tachycardia (rapid heartbeats), can be detected and appropriately treated. Today, patients at moderate risk of arrhythmias can benefit from technology that would permit long- term continuous monitoring of electrical cardiac rhythms outside the hospital environment in the comfort of their own homes. Medical telemetry systems, also known as telemedicine, are evolving rapidly as wireless communication technology advances, evidenced by the commercial products and research prototypes for remote health monitoring that have appeared in recent years. Wireless systems allow patients to move freely in their home and work environment while being monitored remotely by health care professionals.

Liszka, Kathy J.↗

Cardiology Mannequin

Education of medical students in cardiology requires access to patients having a variety of different forms of heart disease. But bringing together student, instructor and patient is a difficult and expensive process that does not benefit the patient. An alternate approach is substitution of a lifelike mannequin capable of simulating many conditions of heart disease. The mannequin pictured below, together with a related information display, is an advanced medical training system whose development benefited from NASA visual display technology and consultative input from NASA's Kennedy Space Center. The mannequin system represents more than 10 years of development effort by Dr. Michael S. Gordon, professor of cardiology at the University of Miami (Florida) School of Medicine.

Source record↗

Axial Halbach Magnetic Bearings

Axial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control.

Eichenberg, Dennis J.↗

Radial Halbach Magnetic Bearings

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Radial Halbach magnetic bearings are based on the same principle as that of axial Halbach magnetic bearings, differing in geometry as the names of these two types of bearings suggest. Both radial and axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control. Axial Halbach magnetic bearings were described in Axial Halbach Magnetic Bearings (LEW-18066-1), NASA Tech Briefs, Vol. 32, No. 7 (July 2008), page 85. In the remainder of this article, the description of the principle of operation from the cited prior article is recapitulated and updated to incorporate the present radial geometry. In simplest terms, the basic principle of levitation in an axial or radial Halbach magnetic bearing is that of the repulsive electromagnetic force between (1) a moving permanent magnet and (2) an electric current induced in a stationary electrical conductor by the motion of the magnetic field. An axial or radial Halbach bearing includes multiple permanent magnets arranged in a Halbach array ("Halbach array" is defined below) in a rotor and multiple conductors in the form of wire coils in a stator, all arranged so the rotary motion produces an axial or radial repulsion that is sufficient to levitate the rotor. A basic Halbach array (see Figure 1) consists of a row of permanent magnets, each oriented so that its magnetic field is at a right angle to that of the adjacent magnet, and the right-angle turns are sequenced so as to maximize the magnitude of the magnetic flux density on one side of the row while minimizing it on the opposite side. The advantage of this configuration is that it makes it possible to approach the theoretical maximum force per unit area that could be exerted by a given amount of permanent-magnet material. The configuration is named after physicist Klaus Halbach, who conceived it for use in particle accelerators. Halbach arrays have also been studied for use in magnetic-levitation ("maglev") railroad trains. In a radial Halbach magnetic bearing, the basic Halbach arrangement is modified into a symmetrical arrangement of sector-shaped permanent magnets mounted on the outer cylindrical surface of a drum rotor (see Figure 2). The magnets are oriented to concentrate the magnetic field on their radially outermost surface. The stator coils are mounted in a stator shell surrounding the rotor.

Eichenberg, Dennis J.↗