Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

URINARY EXCRETION OF PLUTONIUM IN MAYAK WORKERS DURING AND AFTER CA-DTPA ADMINISTRATION

Chelation therapy is sometimes used after potential exposures to plutonium to increase urinary excretion of the radionuclide to improve the accuracy of bioassay measurements. The purpose of this report is to describe the enhancement of urinary excretion of plutonium during and after the administration of the trisodium salt of calcium diethylenetriaminepentaacetate (Ca-DTPA) daily for 3 d to a group of male and female plutonium workers from the Mayak Production Association in Ozyorsk, Russia. One-hundred and two cases (18 females and 84 males) were selected where urinary contents of plutonium, prior to chelation, exceeded the detection threshold. Daily urine collections were obtained during the 3 d of Ca-DTPA treatments. In addition, 58 of these cases had urine bioassays at 1–45 d after chelation. The daily enhancement over baseline values excretion of plutonium was found to be 50.4×/1.4 (geometric mean and geometric standard deviation); 58.9×/1.2; 72.9×/1.4 in the first, second and third days of Ca-DTPA administration. The mean enhancement for the 3-d period was 60.1×/1.7. The rate of plutonium excretion from 1 to 45 d after chelation decreased with a half-period of 3.9 d and the chelation enhancement factor (Кenh-i) is described by the function Кenh-i = (0.79 ± 0.24) + (42.9 ± 1.2) × e-(0.18 ± 0.01) × day.

Environmental Sciences & Ecology↗

Electron paramagnetic resonance dose measurements in teeth of tissue donors to the United States Transuranium and Uranium Registries

Abstract The United States Transuranium and Uranium Registries (USTUR) is a research program that studies actinide biokinetics in occupationally exposed individuals with known intakes of these elements. Electron paramagnetic resonance (EPR) in tooth enamel was applied to reconstruct external doses of nine USTUR registrants. Only in two cases there is a reasonable agreement between the EPR-measured dose and the worksite external dose record. For two registrants, high EPR doses can be explained by possible cancer radiotherapy. For the remaining five cases, EPR doses significantly exceed official occupational doses with no plausible explanation for the observed discrepancy. More EPR dose measurements need to be done to explain this anomaly.

Environmental Sciences & Ecology↗

Latent bone modelling for estimation of plutonium concentration in skeleton of former nuclear workers

Abstract The skeleton is a major plutonium retention site in the human body. Estimation of the total plutonium activity in the skeleton is a challenging problem. For most tissue donors at the United States Transuranium and Uranium Registries, a limited number of bone samples is available. The skeleton activity is calculated using plutonium activity concentration (Cskel) and skeleton weight. In this study, latent bone modelling was used to estimate Cskel from the limited number of analysed bone samples. Data from 13 non-osteoporotic whole-body donors were used to develop latent bone model (LBM) to estimate Cskel for seven cases with four to eight analysed bone samples. LBM predictions were compared to Cskel estimated using an arithmetic mean in terms of accuracy and precision. For the studied cases, LBM offered a significant reduction of uncertainty of Cskel estimate.

Environmental Sciences & Ecology↗

EPR Investigation of Temporal and Thermal Stability of Irradiated Sweeteners

Abstract Electron paramagnetic resonance was used to study the dosimetric properties of commercial sweeteners (sucrose, saccharin, and stevia). The results concluded that sugar has dosimetric properties of interest, which makes it suitable for dose reconstruction, emergency response, and nuclear forensics applications. The radiation dose response was investigated by irradiating samples up to 10 Gy and found to be linear. The post-irradiation stability of samples was observed to be useful for the intended applications. The results showed that the post-irradiation intensities vary from one sample to another, with the general trend demonstrating a small increase in intensities shortly after irradiation followed by an approximately constant leveling out. Finally, the effect of isochronal annealing was studied by heating samples to various temperatures. The results showed an overall stable behavior of the signal below melting temperature.

Environmental Sciences & Ecology↗

Psychosomatic Bias in Low-dose Radiation Epidemiology: Assessing the Role of Radiophobia and Stress in Cancer Incidence

Abstract Historical assessment of radiation effects at low doses (below 0.2 Sv) are generally the result of back extrapolation from higher doses, which are known to have a linear relation between risk and dose. There are multiple counter-examples, and some literature argues that a threshold, nonlinear, or even a beneficial effect (hormeisis) can occur from radiation below these doses. The common theme found in all of these studies stems from the traditional approach of correlating disease rates to stimulus and then effectively curve-fitting the result toward zero dose. What has not been considered in general are the personal stress levels of the exposed individuals due to fear of cancer from low doses. The increased levels of cortisol due to the psychological stress from fear or depression has been shown in the literature to increase cancer probability. The extent to which low-dose exposed individuals were highly fearful or stressed from the radiation exposure would then give rise to elevated cancer based on stress rather than a fundamental radiogenic mechanism. If the population under epidemiological study is aware of a potential historical exposure (no matter how small) and has then lived under stress from fear or depression due to that exposure, the psychosomatic effects will bias the epidemiology accordingly and so should be quantified and accounted for as done with the effects of smoking. Health Phys. 129(0):000-000; 2025

Environmental Sciences & Ecology↗

A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters

Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.

Environmental Sciences & Ecology↗

Locoregional Treatment of Glioblastoma With Targeted α Therapy: [213Bi]Bi-DOTA–Substance P Versus [225Ac]Ac-DOTA–Substance P—Analysis of Influence Parameters

Background Glioblastoma (GB) is the most malignant primary brain tumor. Therefore, introduction of new treatment options is critically important. The aim of this study was to assess local treatment with α emitters [ 213 Bi]Bi-DOTA–substance P (SP) and [ 225 Ac]Ac-DOTA-SP. Methods Treatment was performed as salvage therapy in patients with recurrent primary and secondary GB. [ 213 Bi]Bi-DOTA-SP with injected activity 1.85 GBq per cycle was used in 20 primary (48.2 ± 11.8 years old) and in 9 secondary (38.8 ± 10.8 years old) GB patients and [ 225 Ac]Ac-DOTA-SP in 15 primary (45.1 ± 9.9 years old) and in 6 secondary (37.8 ± 6.4 years old) GB patients with a dose escalation scheme (10, 20, and 30 MBq). Results Local treatment with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP was well tolerated with only few adverse effects. There was no statistically significant difference between [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP groups in survival parameters. For primary GB, survival parameters of patients treated with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP were as follows(in months): progression-free survival time, 2.7 versus 2.4; OS-d (overall survival from time of diagnosis to death from any cause), 23.6 versus 21.0; OS-t (overall survival from the start of treatment to death from any cause), 7.5 versus 5.0; and OS-r (overall survival from recurrence in primary tumors to death from any cause), 10.9 versus 12.0. Survival parameters of secondary GB patients treated with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP were as follows (in months): progression-free survival time, 5.8 versus 2.4; OS-d, 52.3 versus 65.0; OS-t, 16.4 versus 16.0; and OS-c (overall survival from conversion into secondary GB multiforme to death from any cause), 18.4 versus 36.0. Conclusions The similarity results of 213 Bi or 225 Ac may suggest that the local treatment of brain tumors can be greatly simplified. The experience to date shows that local radioisotope treatment of brain tumors requires further dosimetry studies, taking into account the complexity of biological processes.

Radiology, Nuclear Medicine & Medical Imaging↗