Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Colossal piezoresistance in narrow-gap Eu 5 In 2 Sb 6

Piezoresistance, the change of the electrical resistance (R) of a material in response to an applied mechanical stress (σ), is the driving principle of electromechanical devices such as strain gauges, accelerometers, and cantilever force sensors. Enhanced piezoresistance has been traditionally observed in two classes of uncorrelated materials: nonmagnetic semiconductors and composite structures. In this study, we report the discovery of a remarkably large piezoresistance in Eu 5 In 2 Sb 6 single crystals, wherein anisotropic metallic clusters naturally form within a semiconducting matrix due to electronic interactions. Eu 5 In 2 Sb 6 shows a highly anisotropic piezoresistance, and uniaxial pressure along [001] of only 0.4 GPa leads to a resistivity drop of >99.95%, which results in a colossal piezoresistance factor of 5000×10 –11 Pa –1 . Our result not only reveals the role of interactions and phase separation in the realization of colossal piezoresistance, but it also highlights a route to multifunctional devices with large responses to both pressure and magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fluorescent-protein spin qubit

Quantum bits (qubits) are two-level quantum systems that support initialization, readout and coherent control1. Optically addressable spin qubits form the foundation of an emerging generation of nanoscale sensors. The engineering of these qubits has mainly focused on solid-state systems. However, fluorescent proteins, rather than exogenous fluorescent probes, have become the gold standard for in vivo microscopy because of their genetic encodability. Although fluorescent proteins possess a metastable triplet state, they have not been investigated as qubits. Here we realize an optically addressable spin qubit in enhanced yellow fluorescent protein. A near-infrared laser pulse enables triggered readout of the triplet state with up to 20% spin contrast. Using coherent microwave control of the enhanced-yellow-fluorescent-protein spin at liquid-nitrogen temperatures, we measure a (16 ± 2) μs coherence time under Carr–Purcell–Meiboom–Gill decoupling. We express the qubit in mammalian cells, maintaining contrast and coherent control despite the complex intracellular environment. Finally, we demonstrate optically detected magnetic resonance in bacterial cells at room temperature with contrast up to 8%. Our results introduce fluorescent proteins as a powerful qubit platform that paves the way for applications in the life sciences, such as nanoscale field sensing and spin-based imaging modalities.

Feder, Jacob S. [Univ. of Chicago, IL (United Stat↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Cyclic superconducting refrigerators using guided fluxon propagation

We propose cyclic refrigeration in solid state, employing a gas of magnetic field vortices in a type-II superconductor—also known as fluxons—as the cooling agent. Refrigeration cycles are realized by envisioning a racetrack geometry consisting of both adiabatic and isothermal arms, etched into a type-II superconductor. The guided propagation of fluxons in the racetrack is achieved by applying an external electrical current, in a Corbino geometry, through the sample. A gradient of magnetic field is set across the racetrack allowing one to adiabatically cool down and heat up the fluxons, which subsequently exchange heat with the cold and hot reservoirs, respectively. We characterize the steady state of refrigeration cycles thermodynamically for both s -wave and d -wave pairing symmetries, and present their figures of merit such as the cooling power delivered, and the coefficient of performance. Our cooling principle can offer significant cooling for on-chip microrefrigeration purposes, by locally cooling below the base temperatures achievable in a conventional dilution refrigerator. We estimate n W / m m 2 of cooling power per unit area assuming a tunnel coupling with ∼ M Ω µ m 2 specific resistance. Integrating the fluxon fridge to quantum circuits can enhance their coherence time by locally suppressing thermal fluctuations, and improve the efficiency of single photon detectors and charge sensors. Published by the American Physical Society 2024

Karmakar, Tathagata (ORCID:0000000187812017)↗

Electrostatic gate-controlled quantum interference in a high-mobility two-dimensional electron gas at the (La 0.3 ⁢Sr 0.7 )(Al 0.65 ⁢Ta 0.35 )O 3 /SrTiO 3 interface

Here, we report quantum oscillations in magnetoresistance that are periodic in magnetic field (𝐵), observed at the interface between (La 0.3 ⁢Sr 0.7 )(Al 0.65 ⁢Ta 0.35 )O 3 and SrTiO 3 . Unlike Shubnikov–de Haas oscillations, which appear at magnetic fields > 7 T and diminish quickly as the temperature rises, these 𝐵-periodic oscillations emerge at low fields and persist up to 10 K. Their amplitude decays exponentially with both temperature and field, specifying dephasing of quantum interference. Increasing the carrier density through electrostatic gating results in a systematic reduction in both the amplitude and frequency of the oscillations, with complete suppression beyond a certain gate voltage. We attribute these oscillations to the Altshuler-Aronov-Spivak effect, likely arising from naturally formed closed-loop paths due to the interconnected quasi-one-dimensional conduction channels along SrTiO 3 domain walls. The relatively long phase coherence length (≃ 1.8 µ⁢m at 0.1 K), estimated from the oscillation amplitude, highlights the potential of complex oxide interfaces as a promising platform for exploring quantum interference effects and advancing device concepts in quantum technologies, such as mesoscopic interferometers and quantum sensors.

36 MATERIALS SCIENCE↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Relaxation on Qutrit Transitions of Nitrogen-Vacancy Centers in Nanodiamonds

Thanks to their versatility, nitrogen-vacancy (N-𝑉) centers in nanodiamonds have been widely adopted as nanoscale sensors. However, their sensitivities are limited by their short coherence times relative to N-𝑉⁢s in bulk diamond. A more complete understanding of the origins of decoherence in nanodiamonds is critical to improving their performance. Here we present measurements of fast spin relaxation on qutrit transitions between the energy eigenstates composed of the 𝑚 𝑠 =|±1⟩ states of the N-𝑉 − electronic ground state in approximately 40-nm nanodiamonds under ambient conditions. For frequency splittings between these states of 20 MHz or less the maximum theoretically achievable coherence time of the N-𝑉 spin is approximately 2 orders of magnitude shorter than would be expected if the N-𝑉 spin is treated as a qubit. We attribute this fast relaxation to electric field noise. We observe a strong falloff of the qutrit relaxation rate with the splitting between the states, suggesting that, whenever possible, measurements with N-𝑉⁢s in nanodiamonds should be performed at moderate axial magnetic fields (>60 G). We also observe that the qutrit relaxation rate changes with time. As a result, these findings indicate that surface electric field noise is a major source of decoherence for N-𝑉⁢s in nanodiamonds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dipole-lattice nanoparticle resonances in finite arrays

We investigate how the periodic lattices define the collective optical characteristics of the silicon and titanium nanoparticle arrays. We examine the effects of dipole lattice on the resonances of optical nanostructures, including those made of lossy materials, such as titanium. Our approach involves employing coupled-electric-magnetic-dipole calculations for finite-size arrays, as well as lattice sums for effectively infinite arrays. Our model shows that the convergence to the infinite-lattice limit is faster when the resonance is broad, requiring fewer array particles. Our approach differs from previous works by altering the lattice resonance through modifications in the array period. We observed that a higher number of nanoparticles is necessary to achieve convergence to the infinite-array limit. Additionally, we observe that the lattice resonances excited next to higher diffraction orders (such as second order) converge more quickly toward the ideal case of an infinite array than the lattice resonances related to the first diffraction order. This work reports on the significant advantages of using a periodic arrangement of lossy nanoparticles and the role of collective excitation in enhancing response from transition metals, such as titanium, nickel, tungsten, and so on. The periodic arrangement of nanoscatterers allows for the excitation of strong dipoles, boosting the performance of nanophotonic devices and sensors by improving the strength of localized resonances.

36 MATERIALS SCIENCE↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computed Tomography Scanning and Geophysical Measurements of Appalachian Basin Core from the Jones and Laughlin #1 Well, Beaver County, PA

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Appalachian Basin core from Beaver County, Pennsylvania. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE) and the Pennsylvania Geological Survey to characterize and make publicly available core information from the Onondaga-Huntersville formations of the Appalachian Basin. This stratigraphic well and the core data produced in this report will aid in understanding the structural complexities of the Onondaga-Huntersville formations. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/jonesandlaughlin1well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with imaging performed with the NETL medical CT scanner over the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for further study. Targeted higher resolution CT scanning of select sections was performed with NETL’s micro-CT scanner. The combination of methods used provides a multiscale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Quantum sensing for fundamental physics efforts at SQMS

One of the areas of research of the Superconducting Quantum Systems and Materials (SQMS) center is the application of quantum sensing to fundamental physics searches, demonstrating that quantum sensors can greatly improve the sensitivity of experiments searching for Beyond the Standard Model (BSM) physics, or performing high-precision measurements. Theorists have developed many ideas for BSM physics that would result in interactions that can in principle be detected, but with signals small enough that they haven t been observed yet. In this field, the capability to lower the detector s thermal noise to few or dozens of mK, and to use QIS technologies such as Josephson Parametric Amplifiers and photon counters (in-situ or itinerant) enable us to reach unprecedented sensitivities and faster scan rates. Here is presented an overview of the quantum sensing efforts at SQMS [1], focusing on theoretical advancements and experimental searches for Dark Sector particles (as dark matter candidates and not), gravitational waves, and precision measurements. The experiments conducted, or under preparation, include axion dark matter (DM) [2, 3], dark photon DM searches [4,5], light-shining-through-wall experiments [6], cavity-based searches for high frequency gravitational waves [7], and measurements of the electron magnetic moment [8]. [1] Berlin, A., et al. "Searches for new particles, dark matter, and gravitational waves with SRF cavities." arXiv preprint arXiv:2203.12714 (2022). [2] Giaccone, B., et al. "Design of axion and axion dark matter searches based on ultra high Q SRF cavities." arXiv preprint arXiv:2207.11346 (2022). [3] Braggio, C., et al. "Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter." arXiv preprint arXiv:2403.02321 (2024). [4] Fan, X., et al. "One-electron quantum cyclotron as a milli-eV dark-photon detector." Physical review letters 129.26 (2022): 261801. [5] Cervantes, R., et al. "Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities." Physical Review D 110.4 (2024): 043022. [6] Romanenko, A., et al. "Search for dark photons with superconducting radio frequency cavities." Physical review letters 130.26 (2023): 261801. [7] Berlin, A., et al. "Electromagnetic cavities as mechanical bars for gravitational waves." Physical Review D 108.8 (2023): 084058. [8] Fan, X., et al. "Measurement of the electron magnetic moment." Physical review letters 130.7 (2023): 071801.

Giaccone, Bianca↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

Development of a new control rod drive mechanism design for the ISU AGN-201M reactor

The Aerojet General Nucleonics (AGN) model 201-Modified, known as the AGN-201M reactor, plays an essential role in the educational and research activities at Idaho State University (ISU). The ISU AGN-201M's original Control Rod Drive Mechanism (CRDM) has been in operation for more than fifty years with no large-scale redesigns. The CRDM is required to eject the fuel rods within one second during a SCRAM event (also known as a 'reactor trip') and adjust the control rods' insertion speed, and keeps the rod insertion sequence correct. The existing control rod drive mechanisms meet these criteria but experience a few concerns due to aging. Concerns include complex maintenance and costly repairs for old electromechanical components, rod position feedback errors, and the impediment of the plate during a SCRAM due to binding of the lead screws of the existing mechanism. During a binding event, the drive mechanism becomes locked, preventing the control rod's magnetic plate from moving in or out under the reactor's normal and emergency operating conditions. Although, the binding has no effect on the ability of the rod to exit the core during the SCRAM. To counteract the concerns and issues with the current CRDM, a new design has been proposed using newer components and a simplified design. The new design utilizes more advanced electric and mechanical components that are commercially available. The new CRDM system is divided into four main aspects: (1) control rod movement design (motor, lead screw, guide rods), (2) control rod ejection (springs, electromagnet), (3) control rod position and feedback (position transducer, microswitches), and (4) material selection and structural analysis. The new design aims to reduce the overall complexity and probability of failure to improve the reactor's overall reliability. With proper material selection and improved structural design, the new drives are lighter with little to no change in structural integrity. The new control rod drive mechanism eliminates binding scenarios by using a single lead screw and implementing additional guide rods. An advanced linear position sensor and microswitches replace the existing and aging synchro system for accurate rod position feedback resulting in better reactivity control. The new design meets the reactor's operational limits by having an average reactivity insertion of 0.065% Δk/k per second, which corresponds to a total control rod insertion time of 19.23 s, while the control rod's ejection time remains less than one second during a SCRAM event. The new design ensures the reactor's long-term viability for educational and research activities by increasing the reliability and safety of operation for years to come.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Roadmap on Atomtronics: State of the art and perspective

Atomtronics deals with matter-wave circuits of ultracold atoms manipulated through magnetic or laser-generated guides with different shapes and intensities. In this way, new types of quantum networks can be constructed in which coherent fluids are controlled with the know-how developed in the atomic and molecular physics community. In particular, quantum devices with enhanced precision, control, and flexibility of their operating conditions can be accessed. Concomitantly, new quantum simulators and emulators harnessing on the coherent current flows can also be developed. Here, the authors survey the landscape of atomtronics-enabled quantum technology and draw a roadmap for the field in the near future. The authors review some of the latest progress achieved in matter-wave circuits' design and atom-chips. Atomtronic networks are deployed as promising platforms for probing many-body physics with a new angle and a new twist. The latter can be done at the level of both equilibrium and nonequilibrium situations. Numerous relevant problems in mesoscopic physics, such as persistent currents and quantum transport in circuits of fermionic or bosonic atoms, are studied through a new lens. The authors summarize some of the atomtronics quantum devices and sensors. Finally, the authors discuss alkali-earth and Rydberg atoms as potential platforms for the realization of atomtronic circuits with special features.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗