Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Polyvinyl pyridine microspheres

Microspheres are produced by cobalt gamma radiation initiated polymerization of a dilute aqueous vinyl pyridine solution. Addition of cross-linking agent provides higher surface area beads. Addition of monomers such as hydroxyethylmethacrylate acrylamide or methacrylamide increases hydrophilic properties and surface area of the beads. High surface area catalytic supports are formed in the presence of controlled pore glass substrate.

Rembaum, Alan↗

Cross-linked polyvinyl pyridine coated glass particle catalyst support and aqueous composition or polyvinyl pyridine adducted microspheres

Microspheres are produced by cobalt gamma radiation initiated polymerization of a dilute aqueous vinyl pyridine solution. Addition of cross-linking agent provides higher surface area beads. Addition of monomers such as hydroxyethylmethacrylate acrylamide or methacrylamide increases hydrophilic properties and surface area of the beads. High surface area catalytic supports are formed in the presence of controlled pore glass substrate.

Rembaum, Alan↗

Microsphere insulation systems

A new insulation system is provided that contains microspheres. This insulation system can be used to provide insulated panels and clamshells, and to insulate annular spaces around objects used to transfer, store, or transport cryogens and other temperature-sensitive materials. This insulation system provides better performance with reduced maintenance than current insulation systems.

Allen, Mark S.↗

Hybrid microspheres

Substrates, particularly inert synthetic organic resin beads (10) or sheet (12) such as polystyrene are coated with a covalently bound layer (24) of polyacrolein by irradiation a solution (14) of acrolein or other aldehyde with high intensity radiation. Individual microspheres (22) are formed which attach to the surface to form the aldehyde containing layer (24). The aldehyde groups can be converted to other functional groups by reaction with materials such as hydroxylamine. Adducts of proteins such as antibodies or enzymes can be formed by direct reaction with the surface aldehyde groups.

Rembaum, Alan↗

Polyvinyl pyridine microspheres

Microspheres are produced by cobalt gamma radiation initiated polymerization of a dilute aqueous vinyl pyridine solution. Addition of cross-linking agent provides higher surface area beads. Addition of monomers such as hydroxyethylmethacrylate acrylamide or methacrylamide increases hydrophilic properties and surface area of the beads. High surface area catalytic supports are formed in the presence of controlled pore glass substrate.

Rembaum, Alan↗

Preparation of small bio-compatible microspheres

Small, round, bio-compatible microspheres capable of covalently bonding proteins and having a uniform diameter below about 3500 A are prepared by substantially instantaneously initiating polymerization of an aqueous emulsion containing no more than 35% total monomer including an acrylic monomer substituted with a covalently bondable group such a hydroxyl, amino or carboxyl and a minor amount of a cross-linking agent.

Rembaum, Alan↗

Polarization Dependent Coupling of Whispering Gallery Modes in Microspheres

Two sets of resonances in glass microspheres attached to a standard communication-grade single-mode optical fiber have been observed. It has been found that the strength of the resonances depends strongly on the polarization of the coupled light. Furthermore, the position of the resonances in the wavelength domain depends on the polarization of light in the optical fiber with maximum magnitudes shifted by approximately 45 .

Adamovsky, G.↗

Characterization of Fluorescent Polystyrene Microspheres for Advanced Flow Diagnostics

Fluorescent dye-doped polystyrene latex microspheres (PSLs) are being developed for velocimetry and scalar measurements in variable property flows. Two organic dyes, Rhodamine B (RhB) and dichlorofluorescence (DCF), are examined to assess laser-induced fluorescence (LIF) properties for flow imaging applications and single-shot temperature measurements. A major interest in the current research is the application of safe dyes, thus DCF is of particular interest, while RhB is used as a benchmark. Success is demonstrated for single-point laser Doppler velocimetry (LDV) and also imaging fluorescence, excited via a continuous wave 2 W laser beam, for exposures down to 10 ms. In contrast, when exciting with a pulsed Nd:YAG laser at 200 mJ/pulse, no fluorescence was detected, even when integrating tens of pulses. We show that this is due to saturation of the LIF signal at relatively low excitation intensities, 4-5 orders of magnitude lower than the pulsed laser intensity. A two-band LIF technique is applied in a heated jet, indicating that the technique effectively removes interfering inputs such as particle diameter variation. Temperature measurement uncertainties are estimated based upon the variance measured for the two-band LIF intensity ratio and the achievable dye temperature sensitivity, indicating that particles developed to date may provide about +/-12.5 C precision, while future improvements in dye temperature sensitivity and signal quality may enable single-shot temperature measurements with sub-degree precision.

Maisto, Pietro M. F.↗

Reduction of Wind Tunnel Contamination During Flow Visualization Experiments Using Polystyrene Microspheres

Evaluation of novel methods and materials for seeding tracer particles for particle image velocimetry (PIV) was carried out in the Basic Aerodynamic Research Tunnel (BART) at NASA’s Langley Research Center (LaRC). Seeding of polystyrene latex microspheres (PSLs) from ethanol/water suspensions and from the dry state was carried out using custom built seeders. PIV data generated using the novel methods were found to be in general agreement with data collected using the current seeding methods. Techniques for assessing PSL fouling of wind tunnel surfaces were identified and refined. Initial results suggest that dry seeding PSLs may allow comparable data quality to wet seeding while reducing wind tunnel screen fouling. Results also indicate that further developments to the dry seeding system should focus on increasing single particle flux into the wind tunnel. Modifications to PSLs and seeding equipment to achieve this have been identified and are discussed.

Schmitz, Russell C.↗

Topological Control of Polystyrene-Silica Core-Shell Microspheres

Controllable surface morphology is requisite across a gamut of processes, industries, and applications. The surface morphology of silica-coated polystyrene microspheres was controllably modified to enable generation of both smooth and bumpy, or raspberry-like, surfaces. Although smooth and raspberry-like silica shells on polystyrene templates have been demonstrated extensively, the method described here used readily available materials to produce radical changes in surface morphology from a single polystyrene template coated in silica through a facile sol-gel reaction processes. Silica shells were deposited via a sol-gel process (using tetraethyl orthosilicate as the silica precursor) onto 1 to 2 m diameter anionic polystyrene spheres, fabricated by emulsifier-free polymerization. By varying of the concentration of silica precursor and ammonium hydroxide catalyst and altering the electrostatic surface interactions via addition of a cationic polymeric brush, an array of surface topologies was generated. The resulting silica shells ranged from 100 to 200 nm in thickness, as measured by calcination of the polystyrene template. Empirical relations between reaction conditions and the resulting silica colloid diameter were utilized to understand the resultant silica shell topology. These results may serve as a guide to generate a versatile platform for research in the multitude of applications where polystyrene-silica core-shell particles are utilized.

Zane A. Grady↗

Mesoporous TiO2-B Microspheres with Superior Rate Performance for Lithium Ion Batteries

Mesoporous TiO2-B microsperes with a favorable material architecture are designed and synthesized for high power lithium ion batteries. This material, combining the advantages of fast lithium transport with a pseudocapacitive mechanism, adequate electrode-electrolyte contact and compact particle packing in electrode layer, shows superior high-rate charge-discharge capability and long-time cyclability for lithium ion batteries.

25 ENERGY STORAGE↗

Biocompatibility and Recanalization Characteristics of Hydrogel Microspheres with Polyzene-F as Polymer Coating

The objective of this study was to evaluate inflammatory response and recanalization after embolization with a new spherical embolic agent based on a core and shell design with a hydrogel core of polymethylmethacrylate (PMMA) and a Polyzene-F nanoscale coating in a porcine kidney model. Thirty-six minipigs were enrolled for superselective renal embolization. Polyzene-F-coated PMMA particles and uncoated PMMA particles with a diameter of 300-600 {mu}m were used. Either 4 or 12 weeks post-embolization, arteriography of the embolized kidneys was performed and then compared with pre- and immediate post-embolization arteriograms using a specific recanalization score to determine the extent of recanalization. Using a microscopic inflammation score (Banff classification), the embolized organs were examined for local inflammatory effects which occurred in response to the embolic agent. In Polyzene-F-coated particles, the Banff classification showed an average inflammation score of 0.26 {+-} 0.58 at 4 weeks and of 0.08 {+-} 0.28 at 12 weeks. In uncoated particles, the Banff score measured 0.37 {+-} 0.6 at 4 weeks, which was higher, but without a statistically significant difference. According to the recanalization score used in this study, mild angiographic recanalization was evident in all groups, without statistically significant differences (3.0 {+-} 0.71 in coated particles, 3.09 {+-} 0.81 in uncoated particles; p = 0.74). We conclude that both uncoated hydrogel particles and Polyzene-F-coated embolic agents triggered virtually no inflammatory response and effectively occluded target arteries. This study demonstrates good biocompatibility of the new embolic material. As in other spherical embolic agents, recanalization can occur to some degree.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Toxicity After Radioembolization of the Liver Using {sup 90}Y-Microspheres: Sequential Lobar Versus Whole Liver Approach

Purpose: {sup 90}Y-radioembolization (RE) is a promising technique for delivering high doses of radiation to liver tumors but may result in compromise of liver function. To gain further perspective, we evaluated the toxicity rates of sequential lobar versus 'whole liver' {sup 90}Y-radioembolization. Methods: Thirty-four patients with liver malignancy in noncirrhotic livers were included; {sup 90}Y-radioembolization was performed as either whole liver or sequential lobar treatment in 17 patients each. Standard clinical and liver specific laboratory parameters as well as MR imaging before treatment and at follow-up (6 and 12 weeks) after radioembolization were evaluated for toxicity using the Common Terminology Criteria for Adverse Events (CTCAE). Volumetry of the liver, tumor, and spleen and measurement of portal vein diameter also were performed. Results: Three months after whole liver RE, 14 liver-related grade 3/4 events were recorded versus 2 events after sequential lobar treatment (P < 0.05). Three patients treated with whole liver RE suffered from radioembolization-induced liver disease (REILD). Pathological increases in bilirubin at 3 months were observed for the whole liver group only (52.3 vs. 18.7 {mu}mol/l, P = 0.012). Total liver volume did not change significantly in either group, but shrinkage of the initially treated hepatic lobe with compensatory hypertrophy of the subsequently treated lobe was observed in the sequential lobar group (P < 0.05). Portal vein diameter increased significantly in whole liver-treated patients only (+17% vs. +6.6%, P = 0.043). Conclusions: Noncirrhotic patients undergoing sequential lobar radioembolization had less hepatic toxicity compared to whole liver embolization. The sequential approach should be the preferred strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doxorubicin-Loaded 70–150 μm Microspheres for Liver-Dominant Metastatic Breast Cancer: Results and Outcomes of a Pilot Study

PurposePatients with breast cancer liver metastasis have a poor prognosis. Local therapy for liver metastasis increases survival. The purpose of this pilot prospective study was to evaluate the efficacy and safety of doxorubicin drug-eluting beads chemoembolization for liver-dominant breast cancer metastasis (LdBM) refractory to chemotherapy.Materials and MethodsAll patients with LdBM refractory to of two or more lines of systemic chemotherapy were screened. Two chemoembolizations at 1-month intervals were scheduled for each patient. Tumor responses were evaluated by MRI every 3 months until progression or death. Adverse events were recorded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.02) 1 month after each chemoembolization. All patients were free from systemic treatment until progression. Patients with hormone-positive receptors and/or HER-positive disease status continued their targeted therapy.ResultsOut of 23 patients enrolled (mean age: 57.5 ± 11.5 years), 17 completed two chemoembolizations and six underwent only one because of severe adverse events. At 3-month follow-up, the disease control rate was 83 %. The median progression-free survival from the first chemoembolization was 8 months, and the median overall survival was 17 months. Nineteen patients remained free from any systemic chemotherapy for a mean of 209 ± 92 days until progression. Eight grade 3 (asthenia n = 3, anemia n = 2, thrombocythemia n = 2, liver toxicity n = 1) (Rev 1 Comment 1) occurred after the first procedure. No patient died directly due to the procedure.ConclusionWhile chemoembolization with doxorubicin eluding beads for refractory LdBM leads to an 83 % disease control rate, it also causes severe side effects that need to be adequately managed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioembolization with {sup 90}Y Resin Microspheres of Neuroendocrine Liver Metastases: International Multicenter Study on Efficacy and Toxicity

Purpose: Radioembolization of liver metastases of neuroendocrine neoplasms (NEN) has shown promising results; however, the current literature is of limited quality. A large international, multicentre retrospective study was designed to address several shortcomings of the current literature. Materials: 244 NEN patients with different NEN grades were included. Methods: Primary outcome parameters were radiologic response 3 and 6 months after treatment according to RECIST 1.1 and mRECIST. Secondary outcome parameters included clinical response, clinical and biochemical toxicities. Results: Radioembolization resulted in CR in 2%, PR in 14%, SD in 75% and PD 9% according to RECIST 1.1 and in CR in 8%, PR in 35%, SD in 48% and PD in 9% according to mRECIST. Objective response rates improved over time in 20% and 26% according to RECIST 1.1. and mRECIST, respectively. Most common new grade 3–4 biochemical toxicity was lymphocytopenia (6.7%). No unexpected clinical toxicities occurred. Radioembolization-specific complications occurred in < 4%. In symptomatic patients, improvement and resolution of symptoms occurred in 44% and 34%, respectively. Median overall survival from first radioembolization was 3.7, 2.7 and 0.7 years for G1, G2 and G3, respectively. Objective response is independent of NEN grade or primary tumour origin. Significant prognostic factors for survival were NEN grade/Ki67 index, ≥ 75% intrahepatic tumour load, the presence of extrahepatic disease and disease control rate according to RECIST 1.1. Conclusion: Safety and efficacy of radioembolization in NEN patients was confirmed with a high disease control rate of 91% in progressive patients and alleviation of NEN-related symptoms in 79% of symptomatic patients. Level of evidence: 4.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Five-Years Outcome Analysis of 142 Consecutive Hepatocellular Carcinoma Patients Treated with Doxorubicin Eluting Microspheres 30–60 μm: Results from a Single-Centre Prospective Phase II Trial

Purpose: To assess prospectively long-term results of doxorubicin-loaded HepaSphere 30–60 μm in consecutive patients with hepatocellular carcinoma (HCC) not amenable to curative treatments. Patients and Methods: Single-center study from June 2011 to December 2015 in 151 patients treated with 75 mg of doxorubicin per HepaSphere vial. Baseline: Barcelona Clinic Liver Cancer BCLC A/B was 49.3%/50.7%, and median diameter 6.1 cm (mean 6.7 ± 2.0). Liver function, local response (mRECIST), liver time to progression (LTTP), progression-free survival (PFS), overall survival (OS) and adverse events (AEs) were recorded. Results: Final analysis included 142 patients with median follow-up of 46.8 months (range 4–72) without grade 4/5 AEs, and 30-day mortality was 0%. Mean number of scheduled treatments was 2.6 (range 1–3) and on demand 3 (range 1–8). Complete response for single tumor ≤ 5 cm was 75.0% and 66.7% for Child A and Child B, while for > 5 cm was 28.6% and 11.8%, respectively. OS was 31.0 months (mean 33.3 ± 15.2; range 8–69), notably for BCLC A 41 months (mean 41.1 ± 15.3; range 13–69) and for BCLC B 26.0 (mean 26.0 ± 10.5; range 8–51). OS at 1, 3 and 5 years: 95.8%, 75.7% and 21.4% for BCLC A, and 94.4%, 36.1% and 2.7% for BCLC B. Median LTTP for BCLC A was 11 months (mean 11.9 ± 4.7; range 3–24) and 7.5 for BCLC B (mean 7.9 ± 2.9). Local response was significant for OS and LTTP (p < 0.0001), while size and lesion number affected LPFS and OS (p < 0.001). Conclusions: HepaSphere 30–60 μm loaded with doxorubicin provides a safe and effective treatment option for patients with HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗