Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

373 records · Page 21

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant

A comprehensive front-end engineering design (FEED) study has been undertaken for a post-combustion capture (PCC) unit located at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in a full and unredacted FEED study report with all supporting documents, numbering over 150, also publicly available.

20 FOSSIL-FUELED POWER PLANTS↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗

ElectroCat: Platinum-Group-Metal-Free Engineered Framework Nano-Structure Catalyst (Final Technical Report)

Traditional synthesis methodologies that produce durable, highly active PGM-free electrocatalysts typically consist of a top-down approach utilizing a nitrogen-coordinating precursor, a metal precursor, and a support material. Nitrogen-coordinated transition metal complexes typically are absorbed onto a support material, which is then activated via high-temperature pyrolysis. Selection of the support and the nitrogen coordinating precursor has long been the focal point of efforts to maximize the number of accessible, catalytically active sites. In this project, GWE in collaboration with SRNL and NU will develop durable, highly active, low-cost, PGM-free electrocatalysts for polymer electrolyte membrane fuel cells designed and synthesized using a unique, bottom-up, rationally designed approach. Electrocatalysts are produced via polymerization reaction followed by a high-temperature pyrolysis step. Additionally, this project focuses on catalyst site and ORR mechanistic modeling to better understand the structure-property relationship.

08 HYDROGEN↗

Mathematical Optimization of NGCC Solvent-based Carbon Capture Processes to Explore High Capture Designs

For point-source capture, much of the work to date has focused on achieving 90% capture – a somewhat arbitrary target above which parasitic losses to drive carbon capture and compression systems were believed to be too great to be economically justifiable. The recent push for deep decarbonization has caused this target to be revisited, and existing literature is of limited usefulness as most published studies have focused on carbon capture percentages of 90%. In this work, numerous mathematical optimizations were performed between carbon capture targets between 90%-99.8% of a Natural Gas Combined Cycle (NGCC) plant to better understand incremental cost of these systems so they may be compared to other decarbonization technologies, and to inform technical risk associated with targeting higher capture performance for these types of systems.

carbon capture↗

Hydrogen Infrastructure Modeling and Optimization

HyET, established in 2008, is a small business developing electro-chemical hydrogen compressors. HyET’s goals are for a low-cost, efficient, high-pressure compressor ready for market and installation into hydrogen infrastructure stations servicing mobile fuel cell applications. NLR has been working on hydrogen infrastructure research for over a decade and includes electrolyzer production via electrolysis, storage, compression, dispensing, safety, and performance validation. Accelerating technologies into the marketplace is one goal of NLR’s hydrogen research. Therefore, HyET and NLR have teamed up to provide one year of support for HyET’s modeling and small-scale experiments optimization efforts for HyET’s next-generation electro-chemical compressor.

08 HYDROGEN↗

Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer

The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller.

which can introduce optical path length errors whe↗

Case Study: Systems Analysis of Y-12 Waste Sample Collection

The Environmental Management Organization has established a 90-Day Goal for characterizing, packaging, and dispositioning all waste after it has been declared. If adequate process knowledge is not available, a waste sample must be collected and analyzed. The objective of this case study is to reduce the cycle time for waste sample collection from 14.5 calendar days to 10 calendar days 95% of the time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗