Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N{sub KS}) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C{sub p}) and a number of impacting factors: the number of repeated scans (N{sub R}), number of slices (N{sub S}), number of respiratory phase bins (N{sub P}), N{sub KS}, F, R, and initial respiratory phase at image acquisition (P{sub 0}). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C{sub p} and N{sub R} was found best represented by an exponential function (C{sub P}=100(1−e{sup −0.18N{sub R}}), when N{sub S} = 30, N{sub P} = 6). At a C{sub P} value of 95%, the relative error in tumor volume was 0.66%, indicating that N{sub R} at a C{sub P} value of 95% (N{sub R,95%}) is sufficient. It was found that N{sub R,95%} is approximately linearly proportional to N{sub P} (r = 0.99), and nearly independent of all other factors. The 4D-MRI images of the healthy volunteer clearly demonstrated respiratory motion in the diaphragm region with minimal motion induced noise or aliasing. Conclusions: It is feasible to generate respiratory correlated 4D-MRI by retrospectively reordering k-space based on respiratory phase. This new technology may lead to the next generation 4D-MRI with high spatiotemporal resolution and optimal tumor contrast, holding great promises to improve the motion management in radiotherapy of mobile cancers.

60 APPLIED LIFE SCIENCES↗

An improved nuclear magnetic resonance spectrometer

Cylindrical sample container provides a high degree of nuclear stabilization to a nuclear magnetic resonance /nmr/ spectrometer. It is placed coaxially about the nmr insert and contains reference sample that gives a signal suitable for locking the field and frequency of an nmr spectrometer with a simple audio modulation system.

Elleman, D. D.↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

Analysis of the transient response of nuclear spins in GaAs with/without nuclear magnetic resonance

As an alternative to studying the steady-state responses of nuclear spins in solid state systems, working within a transient-state framework can reveal interesting phenomena. The response of nuclear spins in GaAs to a changing magnetic field was analyzed based on the time evolution of nuclear spin temperature. Simulation results well reproduced our experimental results for the transient oblique Hanle signals observed in an all-electrical spin injection device. The analysis showed that the so called dynamic nuclear polarization can be treated as a cooling tool for the nuclear spins: It works as a provider to exchange spin angular momentum between polarized electron spins and nuclear spins through the hyperfine interaction, leading to an increase in the nuclear polarization. In addition, a time-delay of the nuclear spin temperature with a fast sweep of the external magnetic field produces a possible transient state for the nuclear spin polarization. On the other hand, the nuclear magnetic resonance acts as a heating tool for a nuclear spin system. This causes the nuclear spin temperature to jump to infinity: i.e., the average nuclear spins along with the nuclear field vanish at resonant fields of {sup 75}As, {sup 69}Ga and {sup 71}Ga, showing an interesting step-dip structure in the oblique Hanle signals. These analyses provide a quantitative understanding of nuclear spin dynamics in semiconductors for application in future computation processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural characterization of ion-vapor deposited hydrogenated amorphous carbon coatings by solid state {sup 13}C nuclear magnetic resonance

In the present study, unique structural heterogeneity was observed in ion-vapor deposited a-C:H coatings by performing {sup 13}C MAS and {sup 1}H-{sup 13}C CPMAS experiments on solid state nuclear magnetic resonance devices. Two distinct types of sp{sup 2} C clusters were discovered: one of them denoted as sp{sup 2} C′ in content of 3–12 at. % was non-protonated specifically localized in hydrogen-absent regions, while the other dominant one denoted as sp{sup 2} C″ was hydrogenated or at least proximate to proton spins. On basis of the notably analogous variation of sp{sup 2} C′ content and Raman parameters as function of substrate bias voltage in the whole range of 0.5 kV–3.5 kV, a model of nano-clustering configuration was proposed that the sp{sup 2} C′ clusters were embedded between sp{sup 2} C″ clusters and amorphous sp{sup 3} C matrix as trapped interfaces or boundaries where the sp{sup 2} carbon bonds were highly distorted. Continuous increase of bias voltage would promote the nano-clustering and re-ordering of dominant sp{sup 2} C″ clusters, thus results in a marked decrease of interspace and a change of the content of sp{sup 2} C′ clusters. Further investigation on the {sup 13}C magnetization recovery showed typical stretched-exponential approximation due to the prominent presence of paramagnetic centers, and the stretched power α varied within 0.6–0.9 from distinct types of sp{sup 2} C clusters. Differently, the magnetization recovery of {sup 1}H showed better bi-exponential approximation with long and short T{sub 1}(H) fluctuated within 40–60 ms and 0.1–0.3 ms approximately in content of 80% ± 5% and 20% ± 5%, respectively, varying with various bias voltages. Meanwhile, the interrupted {sup 13}C saturation recovery with an interval of short T{sub 1}(H) showed that most of quick-relaxing protons were localized in sp{sup 2} C″ clusters. Such a short T{sub 1}(H) was only possibly resulted from a relaxation mechanism associated with electron-nuclear dipolar interaction or spinning diffusion, and its partial distribution in sp{sup 2} C″ clusters may imply more complex configurations of unpaired electrons in studied a-C:H coatings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2018. Part 1 of 2: Positron emission tomography, computed tomography, and magnetic resonance

In this review, we summarize key articles that have been published in the Journal of Nuclear Cardiology in 2018 pertaining to nuclear cardiology with advanced multi-modality and hybrid imaging including positron emission tomography, cardiac-computed tomography, and magnetic resonance. In an upcoming review, we will summarize key articles that relate to the progress made in the field of single-photon emission computed tomography. We hope that these sister reviews will be useful to the reader to navigate the literature in our field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗

Parity violation in nuclear magnetic resonance frequencies of chiral tetrahedral tungsten complexes NWXYZ (X, Y, Z = H, F, Cl, Br or I)

Density functional theory within the two-component quasi-relativistic zeroth-order regular approximation (ZORA) is used to predict parity violation shifts in {sup 183}W nuclear magnetic resonance shielding tensors of chiral, tetrahedrally bonded tungsten complexes of the form NWXYZ (X, Y, Z = H, F, Cl, Br or I), as well as for the heavier systems NWHAtF and NWH(117)F for comparison. The calculations reveal that sub-mHz accuracy is required to detect such tiny effects in this class of compounds, and that parity violation effects are very sensitive to the choice of ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of triangularity on the plasma response to resonant magnetic perturbations

The effect of the axisymmetric plasma shape on the non-axisymmetric plasma response to resonant magnetic perturbations is investigated in experiment and modeling for the DIII-D, EAST and ASDEX Upgrade tokamaks. Systematically modeling the effect of the triangularity, whilst keeping other equilibrium quantities largely unchanged, reveals that the plasma response is strongly suppressed at high triangularity compared to that at low triangularity. This is validated through targeted comparison with experiments at DIII-D, EAST, and ASDEX Upgrade. DIII-D and EAST magnetic measurements are used to validate simulations, while at ASDEX Upgrade the plasma edge displacement is measured. Both experiments and modeling find a reduced magnetic plasma response on the high-field side at high triangularity across devices. Multi-modal analysis of the simulation results extracts the mode structure and applied spectrum dependence of each mode. The amplitude of the dominant mode reveals similar trends with the edge resonance and radial displacement near the X-point, which suggests that the multi-mode plasma response provides another way to understand the edge localized mode (ELM) control physics. The plasma response is strongly reduced at high triangularity compared to that at low triangularity, which implies different ELM control effects as shaping is varied. Furthermore, these findings indicate that the plasma shape should be taken into consideration when designing an RMP-ELM control strategy in experiment, and that predictive plasma response calculations can be used to maximize access to RMP-ELM control in future devices by maximizing the coupling between coils and the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision and accuracy of magnetic resonance imaging for lobar classification of benign prostatic hyperplasia

Purpose: To validate the application of a magnetic resonance imaging (MRI)-based lobar classification of benign prostatic hyperplasia (BPH) for use in research and clinical management. Methods: Two radiologists with 5 and 11 years post-fellowship experience were trained in the lobar classification of BPH using an internally developed atlas of prostate anatomy with example MRI images edited by a third senior radiologist designated as the “administrator” of the study. A study population of 140 patients referred to a tertiary academic medical center with known or suspected prostate cancer was selected by the administrator to test the interrater reliability (IRR; precision) of the classification as well as accuracy of the two readers compared to the administrator as the “gold” standard. The intrarater reliability of repeat readings of the administrator was also examined. Percentage of agreement, proportion of agreement, and Cohen’s κ were applied. This was a retrospective IRB-approved study. Results: IRR (precision) between the two interpreting radiologists was 64% agreement, corresponding to unweighted κ of 0.52. Composite proportion of agreement across all BPH types (categories) for interpreting radiologists was 0.67. Observer accuracy was 62% agreement, unweighted κ 0.49, for observer 1 and 67%, unweighted κ 0.58, for observer 2. Intrarater reliability for the administrator was 87% agreement, unweighted κ 0.81 with composite proportion of agreement across all categories of 0.87. Conclusions: MRI lobar classification of BPH is a reproducible and reliable tool for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Uterine Contractility by Magnetic Resonance Imaging in Women Undergoing Embolization of Uterine Fibroids

Purpose: To assess uterine contractility using ultrafast magnetic resonance imaging (cine MRI) before and after uterine fibroid embolization (UFE). Materials and Methods: This is a prospective study of uterine contractility in 26 patients (age 30–41 years) undergoing UFE for symptomatic uterine fibroids. Cine MRI was performed before and 6 months after UFE. Two radiologists evaluated uterine contractility and classified it as absent, ordered, or disordered. Patients were then grouped into three distinct patterns of progression: unchanged contractility (group A), modified contractility (B), and loss of contractility (C). These findings were then confronted with factors that might have interfered with uterine contractility pattern (uterine volume, location of dominant fibroid, fibroid/myometrium index, and fibroid necrosis pattern). Results: Of the 26 patients, 8 (30.7%) had no contractility before the procedure, while 18 (69.2%) exhibited some form of contractility (11 [61%] ordered, 7 [39%] disordered). All 8 patients who had no contractility at baseline exhibited contractility after UFE (5 ordered, 3 disordered). Of the 11 who had ordered contractility at baseline, 9 remained ordered and 2 lost contractility after UFE. Of the 7 with disordered contractility at baseline, 1 remained disordered, 5 progressed to ordered contractility, and 1 lost contractility. Overall, 10 patients (38%) had no change in contractility after UFE (group A), 13 (50%) had a positive change (group B), and 3 (11%) lost contractility (group C). The potential interference factors assessed had no statistically significant effect in any group. Conclusion: In women of reproductive age with symptomatic fibroids, uterine contractility improved significantly after UFE. Level of Evidence: Level 3—non-randomized controlled cohort/follow-up study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Study of the Utility of Magnetic Resonance Imaging in Determining Candidacy for Partial Breast Irradiation

Purpose: Retrospective data have demonstrated that breast magnetic resonance imaging (MRI) may change a patient's eligibility for partial breast irradiation (PBI) by identifying multicentric, multifocal, or contralateral disease. The objective of the current study was to prospectively determine the frequency with which MRI identifies occult disease and to establish clinical factors associated with a higher likelihood of MRI prompting changes in PBI eligibility. Methods and Materials: At The University of Chicago, women with breast cancer uniformly undergo MRI in addition to mammography and ultrasonography. From June 2009 through May 2011, all patients were screened prospectively in a multidisciplinary conference for PBI eligibility based on standard imaging, and the impact of MRI on PBI eligibility according to National Surgical Adjuvant Breast and Bowel Project protocol B-39/Radiation Therapy Oncology Group protocol 0413 entry criteria was recorded. Univariable analysis was performed using clinical characteristics in both the prospective cohort and in a separate cohort of retrospectively identified patients. Pooled analysis was used to derive a scoring index predictive of the risk that MRI would identify additional disease. Results: A total of 521 patients were screened for PBI eligibility, and 124 (23.8%) patients were deemed eligible for PBI based on standard imaging. MRI findings changed PBI eligibility in 12.9% of patients. In the pooled univariable analysis, tumor size ≥2 cm on mammography or ultrasonography (P=.02), age <50 years (P=.01), invasive lobular histology (P=.01), and HER-2/neu amplification (P=.01) were associated with a higher likelihood of MRI changing PBI eligibility. A predictive score was generated by summing the number of significant risk factors. Patients with a score of 0, 1, 2, and 3 had changes to eligibility based on MRI findings in 2.8%, 13.2%, 38.1%, and 100%, respectively (P<.0001). Conclusions: MRI identified additional disease in a significant number of patients eligible for PBI, based on standard imaging. Clinical characteristics may be useful in directing implementation of MRI in the staging of PBI candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of screening of resonant magnetic perturbations in three dimensional edge plasma transport simulations for DIII-D

The impact of resonant magnetic perturbations (RMPs) on the plasma edge can be analyzed in detail by three dimensional computer simulations, which take the underlying magnetic field structure as input. Previously, the 'vacuum approximation' has been used to calculate the magnetic field structure although plasma response effects may result in a screening (or even an amplification) of the external perturbations. Simulation results for an ITER similar shape plasma at the DIII-D tokamak are presented for the full vacuum perturbation field and an ad hoc screening case in comparison to the unperturbed configuration. It is shown that the RMP induced helical patterns in the plasma edge and on the divertor target shrink once screening is taken into account. However, a flat temperature profile is still found in the 'open field line domain' inside the separatrix, while the 'density pump out effect' found in the vacuum RMP case is considerably weakened.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear magnetic resonance studies of pseudospin fluctuations in URu 2 Si 2

Here, we report 29 Si nuclear magnetic resonance measurements in single crystals and aligned powders of URu 2 Si 2 in the hidden order and paramagnetic phases. The spin-lattice relaxation data reveal evidence of pseudospin fluctuations of U moments in the paramagnetic phase. We find evidence for partial suppression of the density of states below 30 K and analyze the data in terms of a two-component spin-fermion model. We propose that this behavior is a realization of a pseudogap between the hidden-order transition T HO and 30 K. This behavior is then compared to other materials that demonstrate precursor fluctuations in a pseudogap regime above a ground state with long-range order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sealed magic angle spinning nuclear magnetic resonance probe and process for spectroscopy of hazardous samples

A magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) probe is described that includes double containment enclosures configured to seal and contain hazardous samples for analysis. The probe is of a modular design that ensures containment of hazardous samples during sample analysis while preserving spin speeds for superior NMR performance and convenience of operation.

36 MATERIALS SCIENCE↗