Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

Optical Signature Analysis of Tumbling Rocket Bodies via Laboratory Measurements

The NASA Orbital Debris Program Office has acquired telescopic lightcurve data on massive intact objects, specifically spent rocket bodies, in order to ascertain tumble rates in support of the Active Debris Removal (ADR) task to help remediate the LEO environment. Rotation rates are needed to plan and develop proximity operations for potential future ADR operations. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA/JSC emulates illumination conditions in space using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. The OMC employs a 75-watt Xenon arc lamp as a solar simulator, an SBIG CCD camera with standard Johnson/Bessel filters, and a robotic arm to simulate an object's position and rotation. The light source is mounted on a rotary arm, allowing access any phase angle between 0 -- 360 degrees. The OMC does not attempt to replicate the rotation rates, but focuses on how an object is rotating as seen from multiple phase angles. The two targets studied are scaled (1:48), SL-8 Cosmos 3M second stages. The first target is painted in the standard government "gray" scheme and the second target is primary white, as used for commercial missions. This paper summarizes results of the two scaled rocket bodies, each rotated about two primary axes: (a) a spin-stabilized rotation and (b) an end-over-end rotation. The two rotation states are being investigated as a basis for possible spin states of rocket bodies, beginning with simple spin states about the two primary axes. The data will be used to create a database of potential spin states for future works to convolve with more complex spin states. The optical signatures will be presented for specific phase angles for each rocket body and shown in conjunction with acquired optical data from multiple telescope sources.

Cowardin, H.↗

A self-seeded SRS system for the generation of 1.54-micron eye-safe radiation

A light source is described for the efficient generation of 1.54-micron for eye-safe aerosol lidar operation. The system is based upon an Nd:YAG laser at 1.06 micron which is then Raman-shifted in methane to produce light at the first Stokes wavelength of 1.54 micron. First Stokes light generated in the backward direction was retroreflected back into the Raman cell for amplification in the tail of the 10 ns pump beam. The energy conversion efficiency and the spatial beam quality of the amplified first Stokes were found to be adversely affected when operated at higher repetition rates due to a thermal gradient produced in the generation region. A Stokes energy of 25 mJ was obtained for a pumping energy of 140 mJ at a repetition rate of 10 Hz. The beam divergence of the amplified Stokes radiation was measured to be less than 1 mrad. The optimized results demonstrate the applicability of this radiation for eye-safe lidar measurements.

Chu, Z.↗

Low Mass Printable Devices for Energy Capture, Storage, and Use for Space Exploration Missions

The energy-efficient, environmentally friendly technology that will be presented is the result of a Space Act Agreement between -Technologies Worldwide, Inc., and the National Aeronautics and Space Administration s (NASA s) Marshall Space Flight Center (MSFC). This work combines semiconductor and printing technologies to advance lightweight electronic and photonic devices having excellent potential for commercial and exploration applications, and is an example of industry and government cooperation that leads to novel inventions. Device development involves three energy generation and consumption projects: 1) a low mass efficient (low power, low heat emission) micro light-emitting diode (LED) area lighting device; 2) a low-mass omni-directional efficient photovoltaic (PV) device with significantly improved energy capture; and 3) a new approach to building supercapacitors. These three technologies - energy capture, storage, and usage (e.g., lighting) - represent a systematic approach for building efficient local micro-grids that are commercially feasible; furthermore, these same technologies will be useful for lightweight power generation that enables inner planetary missions using smaller launch vehicles and facilitates surface operations. The PV device model is a two-sphere, light-trapped sheet approximately 2-mm thick. The model suggests a significant improvement over current thin film systems. All three components may be printed in line by printing sequential layers on a standard screen or flexographic direct impact press using the threedimensional printing technique (3DFM) patented by NthDegree. MSFC is testing the robustness of prototype devices in the harsh space and lunar surface environments, and available results will be reported. Unlike many traditional light sources, this device does not contain toxic compounds, and the LED component has passed stringent off-gassing tests required for potential manifesting on spacecraft such as the International Space Station. Future exploration missions will benefit from "green" technology lighting devices such as this, which show great promise for both terrestrial use and space missions.

Frazier, Donald O.↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Apparatus and Methods for Photoacoustic Measurement of Light Absorption of Particulate and Gaseous Species

In one embodiment, a photoacoustic effect measurement instrument for measuring a species (e.g., a species of PM) in a gas employs a pair of differential acoustic cells including a sample cell that receives sample gas including the species, and a reference cell that receives a filtered version of the sample gas from which the species has been substantially removed. An excitation light source provides an amplitude modulated beam to each of the acoustic cells. An array of multiple microphones is mounted to each of the differential acoustic cells, and measures an acoustic wave generated in the respective acoustic cell by absorption of light by sample gas therein to produce a respective signal. The microphones are isolated from sample gas internal to the acoustic cell by a film. A preamplifier determines a differential signal and a controller calculates concentration of the species based on the differential signal.

Yu, Zhenhong↗

Anatomical features of pepper plants (Capsicum annuum L.) grown under red light-emitting diodes supplemented with blue or far-red light

Pepper plants (Capsicum annuum L. cv., Hungarian Wax) were grown under metal halide (MH) lamps or light-emitting diode (LED) arrays with different spectra to determine the effects of light quality on plant anatomy of leaves and stems. One LED (660) array supplied 90% red light at 660 nm (25nm band-width at half-peak height) and 1% far-red light between 700-800nm. A second LED (660/735) array supplied 83% red light at 660nm and 17% far-red light at 735nm (25nm band-width at half-peak height). A third LED (660/blue) array supplied 98% red light at 660nm, 1% blue light between 350-550nm, and 1% far-red light between 700-800nm. Control plants were grown under broad spectrum metal halide lamps. Plants were gron at a mean photon flux (300-800nm) of 330 micromol m-2 s-1 under a 12 h day-night photoperiod. Significant anatomical changes in stem and leaf morphologies were observed in plants grown under the LED arrays compared to plants grown under the broad-spectrum MH lamp. Cross-sectional areas of pepper stems, thickness of secondary xylem, numbers of intraxylary phloem bundles in the periphery of stem pith tissues, leaf thickness, numbers of choloplasts per palisade mesophyll cell, and thickness of palisade and spongy mesophyll tissues were greatest in peppers grown under MH lamps, intermediate in plants grown under the 660/blue LED array, and lowest in peppers grown under the 660 or 660/735 LED arrays. Most anatomical features of pepper stems and leaves were similar among plants grown under 660 or 660/735 LED arrays. The effects of spectral quality on anatomical changes in stem and leaf tissues of peppers generally correlate to the amount of blue light present in the primary light source.

NASA Discipline Life Support Systems↗

Fiber optic sensing system

A fiber optic interferometer utilizes a low coherence light emitting diode (LED) laser as a light source which is filtered and driven at two RF frequencies, high and low, that are specific to the initial length of the resonator chamber. A displacement of a reflecting mirror changes the length traveled by the nonreferencing signal. The low frequency light undergoes destructive interference which reduces the average intensity of the wave while the high frequency light undergoes constructive interference which increases the average intensity of the wave. The ratio of these two intensity measurements is proportional to the displacement incurred.

Adamovsky, Grigory↗

Jet Evolution Visualized and Quantified Using Filtered Rayleigh Scattering

Filtered Rayleigh scattering was utilized as a flow diagnostic in an investigation of a method for enhancing mixing in supersonic jets. The primary objectives of the study were to visualize the effect of vortex generating tabs on supersonic jets, to exact quantitative data from these planar visualizations, and to detect the presence of secondary flows (i.e., streamwise vorticity) generated by the tabs. An injection seeded frequency-doubled Nd:YAG was the light source and a 14 bit Princeton Instruments iodine charge coupled display (ICCD) camera recorded the image through an iodine cell. The incident wave length of the laser was held constant for each flow case so that the filter absorbed unwanted background light, but permitted part of the thermally broadened Rayleigh scattering light to pas through. The visualizations were performed for axisymmetric jets (D=1.9 cm) operated at perfectly expanded conditions for Mach 1.0, 1.5, and 2.0. All data were recorded for the jet cross section at x/D=3. One hundred instantaneous images were recorded and averaged for each case, with a threshold set to eliminate unavoidable particulate scattering. A key factor in these experiments was that the stagnation air was heated such that the expansion of the flow in the nozzle resulted in the static temperature in the jet being equal to the ambient temperature, assuming isentropic flow. Since the thermodynamic conditions of the flow were approximately the same for each case, increases in the intensity recorded by the ICCD camera could be directly attributed to the Doppler shift, and hence velocity. Visualizations were performed for Mach 1.5 and Mach 2.0 jets with tabs inserted at the nozzle exit. The distortion of the jet was readily apparent and was consistent with Mie scattering-based visualizations. Asymmetry in the intensities of the images indicate the presence of secondary flow patterns which are consistent with the streamwise vortices measured using more traditional diagnostics in subsonic jets with the same tab configurations. Because each tab causes shocks to form, the assumption of isentropic flow is not valid for these cases. However, within a reasonable first-order estimation,the intensity across the illuminated plane for these cases can be related to a value combining density and velocity.

Reeder, Mark F.↗

Nonlinear optical processing with Fabry-Perot interferometers containing phase recording media

New techniques in nonlinear optical processing are explored, based on the operation of intensity level selection as performed by a Fabry-Perot interferometer containing a phase object. The image being processed is recorded on a medium between the mirrors as a spatially varying phase shift less than pi. The interferometer only transmits light through those portions of the object that corresponds to a single value of the phase and hence to a single intensity level in the input. More complicated operations such as thresholding and analog-to-digital conversion are performed by modulating the light source as the different levels are selected. Photoresist and lithium niobate have been used as phase objects, and experimental data for both are presented. Three kinds of Fabry-Perot interferometers have been used to demonstrate nonlinear processing using coherent and incoherent light. Color images have been produced with black and white inputs and white light illumination.

Bartholomew, B. J.↗

Passive Acoustic Tomography Tested for Measuring Gas Temperatures

The requirements of higher performance, better fuel economy, and lower emissions place an increasing premium on knowing the internal operating parameters of jet engines. One of the most important is the gas temperature in the post combustor section of the engine. Typically the gas temperature is measured with a thermocouple probe or by some optical technique such as Rayleigh scattering. Probes, while providing valuable information, have several limitations. The probe signal must be corrected for radiation and conduction losses, probes provide only a point measurement, and probes must be constructed of materials whose melting points are lower than the temperature of the environment into which they are inserted. Some of the disadvantages of probes are overcome by various optical techniques. Nothing needs to be inserted into the flow, and the temperature can be directly related to the signal by known physical laws. However, optical techniques require optical access (i.e., a window) and a light source (such as a laser), and they are very sensitive to the presence of particles in the flow. To overcome these problems, researchers from the NASA Glenn Research Center and The University of Nevada are developing a technique that uses sound instead of light to measure gas temperature. Like optical techniques, it is nonintrusive--no probe need be exposed to the combustion environment--and the temperature is directly related to a measured quantity--the speed of sound, which is proportional to the square root of the absolute temperature. The temperature profile inside the engine is constructed from the differences in arrival time between correlated signals from an array of microphones placed around the circumference of the engine. In much the same way as a complete picture of the inside of your body can be constructed from an array of x-ray photographs taken at different angles, the temperature profile in the engine is constructed from the angular array of microphones. It is tomography by sound waves. Active acoustic tomography, in which a sound pulse is injected into the flow and the time delays between members of an array of microphones are used to construct the temperature field has been used successfully in the stacks of power plants. However, the flow field inside a jet engine is much too noisy for it to be possible to detect an externally injected sound pulse. Instead we are developing passive acoustic tomography, which uses the sound already present in the flow.

Fralick, Gustave C.↗

Spacecraft Lighting to Mitigate Microbial Growth

ISS crew health research indicate risk for immune system degradation for long duration missions, necessitating the need to maximize countermeasures on microbial growth (1). This project will investigate applications using violet (400nm) LEDs to mitigate growth of bacteria on architectural surfaces. The application is primarily for architectures and surfaces where a higher amount of bacterial growth is expected. The project will build two different types of violet light sources that represent lamp types that could be installed in spacecraft applications. Under a controlled setting, using violet LEDs, the evaluation will test the effectiveness of a glowing work surface using LED Panel verses an LED array overhead lamp. The effectiveness of the lighting systems to attenuate bacterial growth will be compared to a control. The results of this study can be used to inform spacecraft system architects on novel ways to improve habitat health, and reduce reliance on manual cleaning methods.

Clark, Toni A.↗

Infrared viewing permits human iris response studies

Infrared image converter tube and a filtered light source monitor and measure the eye of a subject during experimental task-work operations to obtain a more natural measurement of unimpeded iris response. The device permits observation in the near infrared region, with little stimulation to the eye except by normal ambient lighting.

Schnass, E. R.↗

Monitoring Temperatures of Tires Using Luminescent Materials

A method of noncontact, optical monitoring of the surface temperature of a tire has been devised to enable the use of local temperature rise as an indication of potential or impending failures. The method involves the use of temperature-sensitive paint (or filler): Temperature-sensitive luminescent dye molecules or other luminescent particles are incorporated into a thin, flexible material coating the tire surface of interest. (Alternatively, in principle, the luminescent material could be incorporated directly into the tire rubber, though this approach has not yet been tested.) The coated surface is illuminated with shorter-wavelength light to excite longer-wavelength luminescence, which is observed by use of a charge-coupled-device camera or a photodetector (see Figure 1). If temporally constant illumination is used, then the temperature can be deduced from the known temperature dependence of the intensity response of the luminescence. If pulsed illumination is used, then the temperature can be deduced from the known temperature dependence of the time or frequency response of the luminescence. If sinusoidally varying illumination is used, then the temperature can be deduced from the known temperature dependence of the phase response of the luminescence. Unlike a prior method of monitoring the temperature at a fixed spot on a tire by use of a thermocouple, this method is not restricted to one spot and can, therefore, yield information on the spatial distribution of temperature: in particular, it enables the discovery of newly forming hot spots where damage may be starting. Also unlike in the thermocouple method, the measurements in this method are not vulnerable to breakage of wires in repeated flexing of the tire. Moreover, unlike in another method in which infrared radiation is monitored as an indication of surface temperature, the luminescence measurements in this method are not significantly affected by changes in infrared emissivity. This method has been demonstrated in application to the outside surface of a tire (see Figure 2), using both constant and pulsed light sources for illumination and cooled, slow-scan, gated CCD cameras for detection. For observing the temperature of the inside surface of a tire (this has not yet been done), it would probably be necessary to use fiber optics and/or windows for coupling excitation light into, and coupling luminescence out of, the interior volume.

Bencic, Timothy J↗

Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

English, T. C.↗

Global auroral imaging instrumentation for the Dynamics Explorer Mission

The instrumentation for obtaining global images of the auroral oval from the high-altitude spacecraft of the Dynamics Explorer Mission is described. It is noted that the three spin-scan auroral imaging photometers are expected to be able to effectively view the dim emissions from earth in the presence of strong stray light sources near their fields-of-view along the sunlit portion of the spacecraft orbit. A special optical design that includes an off-axis parabolic mirror as the focusing element and super-reflecting mirror surfaces is used to minimize the effects of stray light. The rotation of the spacecraft and an instrument scanning mirror provide the two-dimensional array of pixels making up an image frame. It is pointed out that the full width of the fields-of-view of the photometers corresponding to a single pixel is 0.29 deg and that the angular dimensions of a typical full frame are 30 deg x 30 deg and span 14,400 pixels.

Frank, L. A.↗

Laser Induced Fluorescence (LIF) as a Remote Sensing Tool: A Review

Vegetational changes are primary indicators of the present and future ecological status of the globe. These are changes which not only impact upon the primary productivity, but the total of the biogeochemical processes occurring on the planet. The impacts of global climatic and other environmental changes on vegetation must be monitored by some means in order to develop models which will allow us to predict long term effects. Large scale monitoring is now possible only with remote sensing systems, primarily passive reflectance, obtained by the use of satellite and aircraft platforms. However, passive reflectance techniques at this time are limited in their ability to detect subtle changes in the concentration and oxidation states of the many compounds involved in the light reactions of photosynthesis. Knowledge of these changes we consider to be fundamental in the remote assessment of both the rate and efficiency of photosynthesis and also the early detection of stress damage. The above factors pointed to the desirability of a sensing technique with the sensitivity and specificity necessary for detecting and quantifying those biological entities involved in photosynthesis. Another optical technique for vegetation monitoring is fluorescence. Previously, the lack of adequate excitation light sources and detector technologies have limited the use of fluorescence on intact plant leaves in the field. It is only recently with the advent of lasers with short pulse duration and advanced detector technologies that fluorescence measurements in the remote mode have become possible in the presence of ambient light.

Chappelle, E. W.↗

Planar Particle Imaging and Doppler Velocimetry System and Method

A planar velocity measurement system (100) is operative to measure all three velocity components of a flowing fluid (106) across an illuminated plane (108) using only a single line of sight. The fluid flow is seeded with small particles which accurately follow the flow field fluctuations. The seeded flow field is illuminated with pulsed laser light source (102) and the positions of the particles in the flow are recorded on CCD cameras (122,124). The in-plane velocities are measured by determining the in-plane particle displacements. The out-of-plane velocity component is determined by measuring the Doppler shift of the light scattered by the particles. Both gas and liquid velocities can be measured, as well as two-phase flows.

Wernet, Mark P.↗