Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Predicting SLS Launch Environment using a Novel Multiphase Formulation

Powerful acoustic waves generated during ignition of launch vehicles may be dangerous to the vehicle, its payload, or the surrounding structures. The water-based Ignition Overpressure and Sound Suppression (IOP/SS) system at Kennedy Space Center’s (KSC) Launch Complex 39B (LC-39B) will be used to protect the Space Launch System (SLS) from the acoustic vibrations generated during launch. The IOP/SS system uses enormous amounts of water to dampen and attenuate these sound waves. To better understand the launch environment risks and to study the effectiveness of the IOP/SS system it is desirable to have time-accurate unsteady simulations of the vehicle ignition with water-based sound suppression. This paper presents results obtained with a novel, high-order accurate, and robust numerical method designed for simulating compressible multiphase flows. A positivity-preserving finite difference scheme is utilized which is formally high-order accurate and also provably robust. Robustness is critical due to the extreme nature of the flow which exhibits highly nonlinear shock and rarefaction waves interacting with liquid-gas interfaces with density ratios of the order of 1000:1. Furthermore, the high-order accuracy (and the high resolution property) is desirable for predicting wave phenomena like IOP waves since the signal can be resolved accurately and propagated long distances with fewer grid points. This finite-difference method was developed using NASA’s Launch, Ascent, and Vehicle Aerodynamics (LAVA) Cartesian immersed boundary framework. We present a validation case by applying our solver to the SLS Scale Model Acoustic Test (SMAT). The SLS SMAT is a well-instrumented 5% scale model test meant to represent the SLS at NASA KSC’s LC-39B pad. Scale IOP tests were performed with and without the sound suppression water and included many sensors which recorded the pressure waves produced during ignition. For this validation case we conduct two simulations, likewise with and without sound suppression water, and compare the SLS SMAT pressure sensor signals with our numerical signals at identical locations. Following this validation case we present a study of the SLS launch environment to examine engineering safety concerns about the mobile launch pad. Engineers at KSC redesigned the main flame deflector at LC-39B anticipating the increased loads from the SLS and to repair damage from prior Shuttle missions. This deflector redesign made use of surface pressure and temperature data from LAVA full-scale SLS simulations without the sound suppression system. The engineers were questioning the possibility of increased pressure loads on the underside of the mobile launcher due to the water in the flame trench. Based on the results established in our simulations of the SLS SMAT, we performed updated calculations for SLS at LC-39B with and without water systems active to assess the readiness of the launch pad for Artemis I launch. Our results show that the IOP/SS system is effective at reducing the overpressure signal and overall sound pressure levels felt by the vehicle and additionally that the pressure loads experienced by the mobile launcher (ML) during engine startup is not increased by the presence of water.

EGS↗

Photo-switchable membrane and method

Switchable gas permeation membranes in which a photo-switchable low-molecular-weight liquid crystalline (LC) material acts as the active element, and a method of making such membranes. Different LC eutectic mixtures were doped with mesogenic azo dyes and infused into track-etched porous membranes with regular cylindrical pores. Photo-induced isothermal phase changes in the imbibed mesogenic material afforded large, reversible changes in the permeability of the photo-switchable membrane to nitrogen. For example, membranes imbibed with a photo-switchable cyanobiphenyl LC material demonstrated low permeability in the nematic state, while the photo-generated isotropic state demonstrated a 16.times.-greater sorption coefficient. Both states obey a high linear sorption behavior in accordance with Henry's Law. In contrast, membranes imbibed with a photo-switchable phenyl benzoate LC material showed the opposite permeability behavior to the biphenyl-imbibed membrane, along with nonlinear sorption behavior.

36 MATERIALS SCIENCE↗

Field induced heliconical structure of cholesteric liquid crystal

A diffraction grating comprises a liquid crystal (LC) cell configured to apply an electric field through a cholesteric LC material that induces the cholesteric LC material into a heliconical state with an oblique helicoid director. The applied electric field produces diffracted light from the cholesteric LC material within the visible, infrared or ultraviolet. The axis of the heliconical state is in the plane of the liquid crystal cell or perpendicular to the plane, depending on the application. A color tuning device operates with a similar heliconical state liquid crystal material but with the heliconical director axis oriented perpendicular to the plane of the cell. A power generator varies the strength of the applied electric field to adjust the wavelength of light reflected from the cholesteric liquid crystal material within the visible, infrared or ultraviolet.

36 MATERIALS SCIENCE↗

A 1D analysis of two high order MOC methods

The work presented here provides two different methods for evaluating angular fluxes along long characteristics. One is based off a projection of the 1D transport equation onto a complete set of Legendre polynomials, while the other uses the 1D integral transport equation to evaluate the angular flux values at specific points along each track passing through a cell. The Moment Long Characteristic (M-LC) method is shown to provide 2(P+1) spatial convergence and significant gains in accuracy with the addition of only a few spatial degrees of freedom. The M-LC method, though, is shown to be ill-conditioned at very high order and for optically thin geometries. The Point Long Characteristic (P-LC) method, while less accurate, significantly improves stability to problems with optically thin cells. The P-LC method is also more flexible, allowing for extra angular flux evaluations along a given track to give a more accurate representation of the shape along each track. This is at the expense of increasing the degrees of freedom of the system, though, and requires an increase in memory storage. This work concludes that both may be used simultaneously within the same geometry to provide the best mix of accuracy and stability possible. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Capillary Liquid Chromatography-Mass Spectrometry for Proteomics

The liquid chromatography (LC)-mass spectrometric (MS) analysis of peptides has become a routine method for proteomics – the study of the entire complement of proteins e.g., expressed by a cell under a specific set of conditions at a specific time. Mixtures of peptides, such as those generated from enzymatic (e.g., trypsin) digestion of globally recovered proteins (i.e. a proteome), are typically very complex and >100,000 different molecular species may be observable using MS detection [1]. LC separations implemented prior to MS for broad protein identification have three major roles: 1) to isolate individual components or reduce complexity as much as possible, 2) to increase sensitivity by concentrating the components into narrow zones prior to MS, and 3) to eliminate or displace interfering species (e.g., salts and polymers) that may be present in proteomics samples. A desired quality of LC separation can be achieved from the use of either multiple steps of moderate quality separations, or fewer steps of high power separations. The former approach is generally more easily accessible for very high quality separations due to the variety of commercialized LC platforms available, while the latter still often requires considerable developmental efforts (for both columns and instrumentation). In addition to proteomics data quality, other differences between these two approaches include proteomics analysis time and sample consumption (and subsequent analysis costs), as well as direct impact on potential proteomics applications that have special requirements in terms of analysis coverage, sample size, dynamic range, sensitivity, and throughput.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Coupling of Nanodroplet Sample Preparation with Liquid Chromatography–Mass Spectrometry for High-Throughput Single-Cell Proteomics

Single-cell proteomics can provide critical biological insight into the cellular heterogeneity that is masked by bulk-scale analysis. Here, we have developed a nanoPOTS (nanodroplet processing in one pot for trace samples) platform and demonstrated its broad applicability for single-cell proteomics. However, because of nanoliter-scale sample volumes, the nanoPOTS platform is not compatible with automated LC-MS systems, which significantly limits sample throughput and robustness. To address this challenge, we have developed a nanoPOTS autosampler allowing fully automated sample injection from nanowells to LC-MS systems. We also developed a sample drying, extraction, and loading workflow to enable reproducible and reliable sample injection. The sequential analysis of 20 samples containing 10 ng tryptic peptides demonstrated high reproducibility with correlation coefficients of >0.995 between any two samples. The nanoPOTS autosampler can provide analysis throughput of 9.6, 16, and 24 single cells per day using 120, 60, and 30 min LC gradients, respectively. As a demonstration for single-cell proteomics, the autosampler was first applied to profiling protein expression in single MCF10A cells using a label-free approach. At a throughput of 24 single cells per day, an average of 256 proteins was identified from each cell and the number was increased to 731 when the Match Between Runs algorithm of MaxQuant was used. Using a multiplexed isobaric labeling approach (TMT-11plex), ~77 single cells could be analyzed per day. We analyzed 152 cells from three acute myeloid leukemia cell lines, resulting in a total of 2558 identified proteins with 1465 proteins quantifiable (70% valid values) across the 152 cells. These data showed quantitative single-cell proteomics can cluster cells to distinct groups and reveal functionally distinct differences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Demonstration of waferscale voltage amplifier and electrostatic quadrupole focusing array for compact linear accelerators

Compact linear accelerators, with beam energies in the kiloelectron volt to megaelectron volt range, have applications in medicine, neutron/X-ray generation, surface modifications, etc. The size, weight, and power of existing accelerators preclude them from mass availability in portable formats. This paper presents a specific implementation of an ion accelerator architecture based on planar wafers with accelerating and focusing sections. Our low cost approach allows the control of the final ion beam energy with potential applications, for example, for accelerator-based ion implantation. In this paper, we demonstrate two important waferscale modules required to build a linear particle accelerator; these include (1) on-wafer voltage amplification for beam acceleration using Inductor-Capacitor (LC) resonators and (2) waferscale electrostatic quadrupole arrays (ESQA) to refocus the ion beams during transport. On-board LC resonators were developed using Printed Circuit Board fabrication processes to implement an LC element resonant at ~ 16.6 MHz with a quality factor of 25. An energy gain of ~ 250 eV was observed using a two wafer acceleration unit with an argon ion beam with 6.5 keV initial energy. A 3 × 3 ESQA was fabricated on a glass wafer with metal electrodes formed by depositing copper metal around the beam apertures. The ESQA was used to focus and defocus an argon ion beam, demonstrating a field gradient of ~ 500 V over a gap of ~ 250 μm.

43 PARTICLE ACCELERATORS↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exceptional Alignment in a Donor–Acceptor Conjugated Polymer via a Previously Unobserved Liquid Crystal Mesophase

Abstract Orienting polymer semiconductors is desirable to optimize device characteristics, provide insight into microstructure, and magnify subtle phase behavior. Here, a combination of uniaxial strain and subsequent heating of the donor–acceptor (DA) polymer PBnDT‐FTAZ is discovered to lead to exceptional optical dichroic ratios of up to 38 (and close to 50 near the polymer's absorption edge). This alignment is achieved due to the existence of a previously undetected thermotropic liquid crystal (LC) mesophase. The LC transition, not discernable through calorimetry, is uncovered through a combination of in situ UV–vis spectroscopy, X‐ray scattering, and dynamic mechanical analysis (DMA). Comparing PBnDT‐FTAZ to the non‐fluorinated PBnDT‐HTAZ and the homo polymer PBnDT, all of which show similar thermal transitions, reveals that exceptional alignment is only found in PBnDT‐FTAZ. This is attributed to the PBnDT‐FTAZ film having two distinct liquid crystal populations, and the polymer templating to a highly aligned, high‐clearing temperature population when heated. The DMA thermal relaxation behavior observed here is also seen in other DA conjugated polymers suggesting that such thermotropic LC mesophases may be common in these materials. These findings demonstrate a polymer semiconductor with remarkable alignment and uncover phase behavior with broad implications for process‐structure‐property relationships in polymer semiconductors.

36 MATERIALS SCIENCE↗

Enhancing Bottom-up and Top-down Proteomic Measurements with Ion Mobility Separations

Proteomic measurements with greater throughput, sensitivity and additional structural information enhance the in-depth characterization of complex mixtures and targeted studies with additional information and higher confidence. While liquid chromatography separation coupled with mass spectrometry (LC-MS) measurements have provided information on thousands of proteins in different sample types, the additional of another rapid separation stage providing structural information has many benefits for analyses. Technical advances in ion funnels and multiplexing have enabled ion mobility separations to be easily and effectively coupled with LC-MS proteomics to enhance the information content of measurements. Finally, herein, we report on applications illustrating increased sensitivity, throughput, and structural information by utilizing IMS-MS and LC-IMS-MS measurements for both bottom-up and top-down proteomics measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the structural complexity of isomeric bile acids with ion mobility spectrometry

Bile acids (BAs) play an integral role in digestion through the absorption of nutrients, emulsification of fats and fat-soluble vitamins, and maintenance of cholesterol levels. Metabolic disruption, diabetes, colorectal cancer, and numerous other diseases have been linked with BA disruption, making improved BA analyses essential. To date, most BA measurements are performed using liquid chromatography separations in conjunction with mass spectrometry measurements (LC-MS). However, 10–40 min LC gradients are often used for BA analyses and these may not even be sufficient for distinguishing all the important isomers present in the human body. Ion mobility spectrometry (IMS) is a promising tool for BA evaluations due to its ability to quickly separate isomeric molecules with subtle structural differences. In this study, we utilized drift tube IMS (DTIMS) coupled with MS to characterize 56 different unlabeled BA standards and 16 deuterated versions. In the DTIMS-MS analyses of 12 isomer groups, BAs with smaller m/z values were easily separated in either their deprotonated or sodiated forms (or both). However, as the BAs grew in m/z value, they became more difficult to separate with two isomer groups being inseparable. Metal ions such as copper and zinc were then added to the overlapping BAs, and due to different binding sites, the resulting complexes were separable. Thus, the rapid structural measurements possible with DTIMS-MS show great potential for BAs measurements with and without prior LC separations.

Zheng, Xueyun↗

Impact of DNA demethylation of the G0S2 gene on the transcription of G0S2 in squamous lung cancer cell lines with or without nuclear receptor agonists

We recently identified that DNA methylation of the G0S2 gene was significantly more frequent in squamous lung cancer than in non-squamous lung cancer. However, the significance of G0S2 methylation levels on cancer cells is not yet known. We investigated the effect of G0S2 methylation levels on cell growth, mRNA expression, and chromatin structure using squamous lung cancer cell lines and normal human bronchial epithelial cells. DNA methylation and mRNA expression of G0S2 were inversely correlated, and in one of the squamous lung cancer cell lines, LC-1 sq, G0S2 was completely methylated and suppressed. Overexpression of G0S2 in LC-1 sq did not show growth arrest or apoptosis. The G0S2 gene has been reported to be a target gene of all-trans retinoic acid and peroxisome proliferator-activated receptor agonists. We treated LC-1 sq with 5-Aza-2'-deoxycytidine, Trichostatin A, all-trans retinoic acid, Wy 14643, or Pioglitazone either alone or in combination. Only 5-Aza-2'-deoxycytidine restored mRNA expression of G0S2. Chromatin immunoprecipitation revealed that histone H3 lysine 9 was methylated regardless of DNA methylation or mRNA expression. In summary, mRNA expression of G0S2 was regulated mainly by DNA methylation in squamous lung cancer cell lines. When the G0S2 gene was methylated, nuclear receptor agonists could not restore mRNA expression of G0S2 and did not show any additive effect on mRNA expression of G0S2 even after the treatment with 5-Aza-2'-deoxycytidine.

60 APPLIED LIFE SCIENCES↗

Peptidome analysis of human skim milk in term and preterm milk

Highlights: •A method was developed for preparation of peptide extracts from human milk. •Analysis of the extracts by LC–MS/MS resulted in the detection of 1000–3000 peptide-like features. •419 Peptides were identified by LC–MS/MS from 34 proteins. •Isotope dimethyl labeling analysis revealed 41 peptides differentially expressed. -- Abstract: The abundant proteins in human milk have been well characterized and are known to provide nutritional, protective, and developmental advantages to both term and preterm infants. Due to the difficulties associated with detection technology of the peptides, the expression of the peptides present in human milk is not known widely. In recent years, peptidome analysis has received increasing attention. In this report, the analysis of endogenous peptides in human milk was done by mass spectrometry. A method was also developed by our researchers, which can be used in the extraction of peptide from human milk. Analysis of the extracts by LC–MS/MS resulted in the detection of 1000–3000 Da peptide-like features. Out of these, 419 peptides were identified by MS/MS. The identified peptides were found to originate from 34 proteins, of which several have been reported. Analysis of the peptides’ cleavage sites showed that the peptides are cleaved with regulations. This may reflect the protease activity and distribution in human body, and also represent the biological state of the tissue and provide a fresh source for biomarker discovery. Isotope dimethyl labeling analysis was also used to test the effects of premature delivery on milk protein composition in this study. Differences in peptides expression between breast milk in term milk (38–41 weeks gestation) and preterm milk (28–32 weeks gestation) were investigated in this study. 41 Peptides in these two groups were found expressed differently. 23 Peptides were present at higher levels in preterm milk, and 18 were present at higher levels in term milk.

60 APPLIED LIFE SCIENCES↗

Intact mass spectrometry screening to optimize hydroxyl radical dose for protein footprinting

Hydroxyl radical protein footprinting (HRPF) using synchrotron radiation is a well-validated method to assess protein structure in the native solution state. In this method, X-ray radiolysis of water generates hydroxyl radicals that can react with solvent accessible side chains of proteins, with mass spectrometry used to detect the resulting labeled products. An ideal footprinting dose provides sufficient labeling to measure the structure but not so much as to influence the results. The optimization of hydroxyl radical dose is typically performed using an indirect Alexa488 fluorescence assay sensitive to hydroxyl radical concentration, but full evaluation of the experiment's outcome relies upon bottom-up liquid chromatography mass spectrometry (LC-MS) measurements to directly determine sites and extent of oxidative labeling at the peptide and protein level. A direct evaluation of the extent of labeling to provide direct and absolute measurements of dose and “safe” dose ranges in terms of, for example, average numbers of labels per protein, would provide immediate feedback on experimental outcomes prior to embarking on detailed LC-MS analyses. To this end, we describe an approach to integrate intact MS screening of labeled samples immediately following exposure, along with metrics to quantify the extent of observed labeling from the intact mass spectra. Intact MS results on the model protein lysozyme were evaluated in the context of Alexa488 assay results and a bottom-up LC-MS analysis of the same samples. In conclusion, this approach provides a basis for placing delivered hydroxyl radical dose metrics on firmer technical grounds for synchrotron X-ray footprinting of proteins, with explicit parameters to increase the likelihood of a productive experimental outcome. Further, the method directs approaches to provide absolute and direct dosimetry for all types of labeling for protein footprinting.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanical properties and durability performance of concretes with Limestone Calcined Clay Cement (LC3)

The adoption of any binder system for structural concrete depends on the performance characteristics desired for addressing the long-term deformation and durability concerns. The major properties influencing the performance includes the shrinkage characteristics governing the long-term deformation, and durability characteristics related to various transport mechanisms, governing the performance in different service conditions. This paper describes the potential of Limestone Calcined Clay Cement (LC{sup 3}) for use in structural concrete in comparison with Ordinary Portland Cement (OPC) and fly ash based blended cement (FA30). Three types of concrete mixtures were designed for the study, two based on achieving an equivalent strength grade (M30 and M50 concrete grade) with each binder, and the third with equal binder content and w/b ratio. Mechanical properties such as compressive strength and elastic modulus, and autogenous and drying shrinkage, along with various durability parameters of the different concretes were assessed. Oxygen permeability, rapid chloride penetration, chloride migration, resistivity development and water sorptivity were the various parameters considered for evaluation of durability performance. The results indicate the superiority of LC{sup 3} binder over other binders in producing durable concrete, especially in a chloride laden environment. The major reason for the better performance was attributed to the more compact and dense microstructure of the system with the LC{sup 3} binder against OPC and FA30. The drying shrinkage performance was seen to be similar for concrete with all three binders.

36 MATERIALS SCIENCE↗

The hydration, microstructure, and mechanical properties of vaterite calcined clay cement (VC 3 )

Limestone (calcite) calcined clay cement (LC 3 ) is a promising low-CO 2 binder, but the low activity of calcite cannot compensate the reduction in clinker factor, resulting in low one-day strength and limiting its broad applications. As recent carbon capture and utilization technologies allow scalable production of vaterite, a more reactive CaCO 3 polymorph, we overcome the challenge by introducing vaterite calcined clay cement (VC 3 ), inspired by the vaterite-calcite phase change. In the present study, VC 3 exhibits higher compressive strengths and faster hydration than LC 3 . Compared to hydrated LC 3 , hydrated VC 3 exhibits increased amount of hemi- and mono-carboaluminate formation and decreased amount of strätlingite formation. With gypsum adjustment, the 1-day strength of VC 3 is higher than that of pure cement reference. Finally, VC 3 , a low-CO 2 binder, presents great potential as a host of the metastable CaCO 3 for carbon storage and utilization and as an enabler of carbon capture at gigaton scales.

36 MATERIALS SCIENCE↗