Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverse Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Multi-Electron Transfer at H-Terminated p-Si Electrolyte Interfaces: Large Photovoltages under Inversion Conditions

Here, photovoltages for hydrogen terminated p-Si(111) in an acetonitrile electrolyte were quantified with methyl viologen [1,1'-(CH 3 ) 2 -4,4'-bipyridinium](PF 6 ) 2 , abbreviated MV 2+ , and [Ru(bpy) 3 ](PF 6 ) 2 , where bpy is 2,2'-bipyridine, that respectively undergo two and three one-electron transfer reductions. The reduction potentials, E°, of the two MV 2+ reductions occurred at energies within the forbidden bandgap, while the three [Ru(bpy) 3 ] 2+ reductions occurred within the continuum of conduction band states. Bandgap illumination resulted in reduction that were more positive than that measured with a degenerately doped n + -Si demonstrative of a photovoltage, Vph, that increased in the order: MV 2+/+ (260 mV) < MV +/0 (400 mV) < Ru 2+/+ (530 mV) ~ Ru +/0 (540 mV) ~ Ru 0/– (550 mV). Pulsed 532 nm excitation generated electron-hole pairs whose dynamics were nearly constant under depletion conditions and increased markedly as the potential was raised or lowered. A long wavelength absorption feature assigned to conduction band electrons provided additional evidence for the presence of an inversion layer. Collectively, the data reveal that the most optimal photovoltage, as well at the longest electron-hole pair lifetime and the highest surface electron concentration, occur when E° lies energetically within the unfilled conduction band states where an inversion layer is present. The bell-shaped dependence for electron-hole pair recombination with the surface potential was predicted by the time-honored SRH model providing a clear indication that this interface provides access to all four bias conditions, i.e., accumulation, flat band, depletion, and inversion. The implications of these findings for photocatalysis applications and solar energy conversion are discussed.

14 SOLAR ENERGY↗

Efficient Neural Network Approaches for Conditional Optimal Transport with Applications in Bayesian Inference

In this work, we present two neural network approaches that approximate the solutions of static and dynamic conditional optimal transport (COT) problems. Both approaches enable conditional sampling and conditional density estimation, which are core tasks in Bayesian inference—particularly in the simulation-based (“likelihood-free”) setting. Our methods represent the target conditional distribution as a transformation of a tractable reference distribution. Obtaining such a transformation, chosen here to be an approximation of the COT map, is computationally challenging even in moderate dimensions. To improve scalability, our numerical algorithms use neural networks to parameterize candidate maps and further exploit the structure of the COT problem. Our static approach approximates the map as the gradient of a partially input convex neural network. It uses a novel numerical implementation to increase computational efficiency compared to state-of-the-art alternatives. Our dynamic approach approximates the conditional optimal transport via the flow map of a regularized neural ODE; compared to the static approach, it is slower to train but offers more modeling choices and can lead to faster sampling. We demonstrate both algorithms numerically, comparing them with competing state-of-the-art approaches, using benchmark datasets and simulation-based Bayesian inverse problems.

97 MATHEMATICS AND COMPUTING↗

A hybrid data-driven and model-based approach for computationally efficient stochastic unit commitment and economic dispatch under wind and solar uncertainty

Stochastic unit commitment (UC) and economic dispatch (ED) are imperative in dealing with uncertainty in renewable forecast for power system operation and planning such that the overall expected production cost is minimized over the planning horizon. However, accurate calculation of the expected production cost requires assessment of a very large number of different scenarios of uncertain renewable resources, such as solar and wind, which is practically infeasible to simulate in real time. This article proposes a hybrid datadriven and physics-based model-predictive paradigm to efficiently solve for stochastic unit commitment and economic dispatch considering uncertainty in wind and solar power forecasts. Here, the novelty of the approach lies in decoupling the production cost estimation from the unit commitment and economic dispatch optimization problems under uncertainty without compromising on the fidelity of the solutions. A data-driven machine learning model is first developed to predict the mean optimal production cost. A physics-based inverse problem is then solved to get the stochastic UC and ED profiles from the expected cost. The presented approach considers, for the first time, solar uncertainty in UC/ED determination and enables efficient and accurate propagation of wind and solar uncertainty to estimate the statistics of the production cost. The effectiveness of the developed approach is demonstrated systematically on a stylized RTS-GMLC single-node system. The overall framework predicts the expected cost 62.5% more accurately than the existing state-of-the-art, on unforeseen days during the entire year, and yields, for the first time, the associated physically consistent UC and ED profiles. The solutions are also shown to be flexible in providing adequate daily reserves to address any statistical deviations from probabilistic power forecasts. The computational time associated with the presented method is only about 10 s compared to over 24 h needed for a conventional stochastic UC/ED determination under uncertainty on an Intel Core i9 processor with 32 GB of RAM.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Particle size effect of Ni-rich cathode materials on lithium ion battery performance

Graphical abstract: The preparation condition of Ni-rich cathode materials was investigated. When the retention time was short, a poor cathode performance was observed. For long retention time condition, cathode performance displayed a best result at pH 12. Highlights: Black-Right-Pointing-Pointer Ni-rich cathode materials (LiNi{sub 0.8}Co{sub 0.15}Al{sub 0.05}O{sub 2}) were prepared by co-precipitation method using separate addition of Al salt. Black-Right-Pointing-Pointer Particle size of Ni-rich cathode materials became larger with increase of retention time and solution pH. Black-Right-Pointing-Pointer Cathode performance was poor for low retention time. Black-Right-Pointing-Pointer Optimal pH for co-precipitation was 12. -- Abstract: Herein, Ni-rich cathode materials (LiNi{sub 0.8}Co{sub 0.15}Al{sub 0.05}O{sub 2}) in lithium ion batteries are prepared by a separate addition of Ni/Co salt and Al sol solution using a continuously stirred tank reactor. Retention time and solution pH were controlled in order to obtain high performance cathode material. Particle size increase was observed with a higher retention time of the reactants. Also, primary and secondary particles became smaller according to an increase of solution pH, which was probably due to a decrease of growth rate. From the cathode application, a high discharge capacity (175 mAh g{sup -1}), a high initial efficiency (90%) and a good cycleability were observed in the cathode material prepared under pH 12 condition, which was attributed to its well-developed layered property and the optimal particle size. However, rate capability was inversely proportional to the particle size, which was clarified by a decrease of charge-transfer resistance measured in the electrochemical impedance spectroscopy.

36 MATERIALS SCIENCE↗

Anisotropic colloidal interactions & assembly in AC electric fields

In this work, we match experimental and simulated configurations of anisotropic epoxy colloidal particles in high frequency AC electric fields by identifying analytical potentials for dipole-field and dipole-dipole interactions. We report an inverse Monte Carlo simulation algorithm to determine optimal fits of analytical potentials by matching simulated and experimental distribution functions for non-uniform liquid, liquid crystal, and crystal microstructures in varying amplitude electric fields. Two potentials that include accurate particle volume and dimensions along with a concentration dependent prefactor quantitatively capture experimental observations. At low concentrations, an effective ellipsoidal point dipole potential works well, whereas a novel stretched point dipole potential is found to be suitable at all concentrations, field amplitudes, and degrees of ordering. The simplicity, accuracy, and adjustability of the stretched point dipole potential suggest it can be applied to model field mediated microstructures and assembly of systematically varying anisotropic particle shapes.

42 ENGINEERING↗

Growth of high quality N-polar AlN(0001) on Si(111) by plasma assisted molecular beam epitaxy

High quality N-polar AlN epilayers were grown and characterized on Si(111) substrates by plasma assisted molecular beam epitaxy as a first step toward growth of N-polar nitrides on Si(111). Polarity inversion to N-face by an optimized predeposition of Al adatoms on the reconstructed 7x7 Si(111) surface was investigated. Al adatoms can saturate the dangling bonds of Si atoms, resulting in growth of AlN in (0001) direction on subsequent exposure to N{sub 2} plasma. N-polarity was confirmed by observing strong 3x3 and 6x6 reflection high-energy electron diffraction reconstructions, convergent beam electron diffraction imaging and KOH etching studies. The structural properties were investigated by x-ray diffraction measurements, cross section and plan-view TEM studies.

36 MATERIALS SCIENCE↗

Recovery of fluctuation spectrum evolution from tomographic shear spectra

Forthcoming large angle surveys are planned to obtain high precision tomographic shear data. In principle, they will allow us to recover the spectra of matter density fluctuation, at various redshift, through the inversion of the expressions yielding shear spectra from fluctuation spectra. This was discussed in previous work, where SVD techniques for matrix inversion were also shown to be the optimal tool to this aim. Here we show the significant improvements obtainable by using a 7 bin tomography, as allowed by future Euclid data, and discuss error propagation from shear to fluctuation spectra. We find that the technique is a promising tool, namely for the analysis of baryon physics through high–l shear spectra and to test the consistency between expansion rate and fluctuation growth.

79 ASTRONOMY AND ASTROPHYSICS↗

Convolutional Neural Network Surrogate Models for the Mechanical Properties of Periodic Structures

The work in this paper describes neural network surrogate models for calculating the effective mechanical properties of a periodic composites. The models achieve good accuracy even when only provided with training data sampling a small portion of the design space. As an example, the surrogate models are applied to solving the inverse design problem of finding structures with optimal mechanical properties. The surrogate models are sufficiently accurate to recover optimal solutions in general agreement with established topology optimization methods. However, improvements will be required to develop robust, efficient neural network-based surrogate models and several directions for future research are highlighted here.

42 ENGINEERING↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Roundtable on Producing and Managing Large Scientific Data with Artificial Intelligence and Machine Learning (Brochure)

The US Department of Energy’s (DOE’s) twelve Basic Energy Sciences (BES) scientific user facilities provide access to the world’s most advanced research instruments, annually serving over 16,000 users with impact reported in nearly 7,000 publications and producing unprecedented quantities of scientific data. While impressive, reaching the full potential of these rapidly growing facilities will require new innovations to solve a variety of technical challenges in data acquisition, control, modeling, and analysis. Artificial intelligence and machine learning (AI/ML) have opened corresponding new avenues in optimization, efficient surrogate models, data analytics, and inverse problems. These intriguing capabilities suggest that AI/ML can greatly accelerate the quest to probe and understand fundamental phenomena across a vast range of lengths and timescales, potentially leading to transformative advances across scientific disciplines.

97 MATHEMATICS AND COMPUTING↗

Noninvasive cross section reconstruction with transport theory constraints

We consider the inverse problem of identifying the spatially variable absorption and scattering properties of a medium by measuring the exiting radiation when the body is actively interrogated. We formulate this inverse problem as a PDE-constrained optimization problem and solve it iteratively with Newton's method. The constraint is given by the radiative transport equation for neutral particles. Two examples are considered. The first is a dual inclusion domain with no scattering. This problem explores the convergence patterns of the method. The second problem is a central inclusion problem with scattering. This problem explores the optical thickness limit of the method. This optical thickness was determined to be 2-3 mean free paths. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multicriteria Optimization in Intensity-Modulated Radiation Therapy Treatment Planning for Locally Advanced Cancer of the Pancreatic Head

Purpose: Intensity-modulated radiation therapy (IMRT) affords the potential to decrease radiation therapy-associated toxicity by creating highly conformal dose distributions. However, the inverse planning process can create a suboptimal plan despite meeting all constraints. Multicriteria optimization (MCO) may reduce the time-consuming iteration loop necessary to develop a satisfactory plan while providing information regarding trade-offs between different treatment planning goals. In this exploratory study, we examine the feasibility and utility of MCO in physician plan selection in patients with locally advanced pancreatic cancer (LAPC). Methods and Materials: The first 10 consecutive patients with LAPC treated with IMRT were evaluated. A database of plans (Pareto surface) was created that met the inverse planning goals. The physician then navigated to an 'optimal' plan from the point on the Pareto surface at which kidney dose was minimized. Results: Pareto surfaces were created for all 10 patients. A physician was able to select a plan from the Pareto surface within 10 minutes for all cases. Compared with the original (treated) IMRT plans, the plan selected from the Pareto surface had a lower stomach mean dose in 9 of 10 patients, although often at the expense of higher kidney dose than with the treated plan. Conclusion: The MCO is feasible in patients with LAPC and allows the physician to choose a satisfactory plan quickly. Generally, when given the opportunity, the physician will choose a plan with a lower stomach dose. The MCO enables a physician to provide greater active clinical input into the IMRT planning process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a ''modified TG-43'' (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an ''isotropic plan'' with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V{sub 200} by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. Conclusions: In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively.

60 APPLIED LIFE SCIENCES↗

SU-F-T-337: Accounting for Patient Motion During Volumetric Modulated Ac Therapy (VMAT) Planning for Post Mastectomy Chest Wall Irradiation

Purpose: To evaluate two dose optimization strategies for maintaining target volume coverage of inversely-planned post mastectomy radiotherapy (PMRT) plans during patient motion. Methods: Five patients previously treated with VMAT for PMRT at our clinical were randomly selected for this study. For each patient, two plan optimization strategies were compared. Plan 1 was optimized to a volume that included the physician’s planning target volume (PTV) plus an expansion up to 0.3 cm from the bolus surface. Plan 2 was optimized to the PTV plus an expansion up to 0.3 cm from the patient surface (i.e., not extending into the bolus). VMAT plans were optimized to deliver 95% of the prescription to 95% of the PTV while sparing organs at risk based on clinical dose limits. PTV coverage was then evaluated following the simulation of patient shifts by 1.0 cm in the anterior and posterior directions using the treatment planning system. Results: Posterior patient shifts produced a difference in D95% of around 11% in both planning approaches from the non-shifted dose distributions. Coverage of the medial and lateral borders of the evaluation volume was reduced in both the posteriorly shifted plans (Plan 1 and Plan 2). Anterior patient shifts affected Plan 2 more than Plan 1 with a difference in D95% of 1% for Plan 1 versus 6% for Plan 2 from the non-shifted dose distributions. The least variation in PTV dose homogeneity for both shifts was obtained with Plan 1. However, all posteriorly shifted plans failed to deliver 95% of the prescription to 95% of the PTV. Whereas, only a few anteriorly shifted plans failed this criteria. Conclusion: The results of this study suggest both planning volume methods are sensitive to patient motion, but that a PTV extended into a bolus volume is slightly more robust for anterior patient shifts.

60 APPLIED LIFE SCIENCES↗

Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emulating the Deutsch-Josza algorithm with an inverse-designed terahertz gradient-index lens

An all-dielectric photonic metastructure is investigated for application as a quantum algorithm emulator (QAE) in the terahertz frequency regime; specifically, we show implementation of the Deustsh-Josza algorithm. The design for the QAE consists of a gradient-index (GRIN) lens as the Fourier transform subblock and patterned silicon as the oracle subblock. First, we detail optimization of the GRIN lens through numerical analysis. Then, we employed inverse design through a machine learning approach to further optimize the structural geometry. Through this optimization, we enhance the interaction of the incident light with the metamaterial via spectral improvements of the outgoing wave.

Blackwell, Ashley N.↗

Solving geosteering inverse problems by stochastic Hybrid Monte Carlo method

The inverse problems arise in almost all fields of science where the real-world parameters are extracted from a set of measured data. The geosteering inversion plays an essential role in the accurate prediction of oncoming strata as well as a reliable guidance to adjust the borehole position on the fly to reach one or more geological targets. This mathematical treatment is not easy to solve, which requires finding an optimum solution among a large solution space, especially when the problem is non-linear and non-convex. Nowadays, a new generation of logging-while-drilling (LWD) tools has emerged on the market. The so-called azimuthal resistivity LWD tools have azimuthal sensitivity and a large depth of investigation. Hence, the associated inverse problems become much more difficult since the earth model to be inverted will have more detailed structures. The conventional deterministic methods are incapable to solve such a complicated inverse problem, where they suffer from the local minimum trap. Alternatively, stochastic optimizations are in general better at finding global optimal solutions and handling uncertainty quantification. In this article, we investigate the Hybrid Monte Carlo (HMC) based statistical inversion approach and suggest that HMC based inference is more efficient in dealing with the increased complexity and uncertainty faced by the geosteering problems.

97 MATHEMATICS AND COMPUTING↗