Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments & Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Improved instrumentation for intensity-, wavelength-, temperature-, and magnetic field-resolved photoconductivity spectroscopy

We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe a rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.

36 MATERIALS SCIENCE↗

BEYONDPLANCK X. Planck Low Frequency Instrument frequency maps with sample-based error propagation

We present Planck Low Frequency Instrument (LFI) frequency sky maps derived within the BEYONDPLANCK framework. This framework draws samples from a global posterior distribution that includes instrumental, astrophysical, and cosmological parameters, and the main product is an entire ensemble of frequency sky map samples, each of which corresponds to one possible realization of the various modeled instrumental systematic corrections, including correlated noise, time-variable gain, as well as far sidelobe and bandpass corrections. This ensemble allows for computationally convenient end-to-end propagation of low-level instrumental uncertainties into higher-level science products, including astrophysical component maps, angular power spectra, and cosmological parameters. We show that the two dominant sources of LFI instrumental systematic uncertainties are correlated noise and gain fluctuations, and the products presented here support – for the first time – full Bayesian error propagation for these effects at full angular resolution. We compared our posterior mean maps with traditional frequency maps delivered by the Planck Collaboration, and find generally good agreement. The most important quality improvement is due to significantly lower calibration uncertainties in the new processing, as we find a fractional absolute calibration uncertainty at 70 GHz of Δg 0 /g 0 = 5 x 10 -5 , which is nominally 40 times smaller than that reported by Planck 2018. However, we also note that the original Planck 2018 estimate has a nontrivial statistical interpretation, and this further illustrates the advantage of the new framework in terms of producing self-consistent and well-defined error estimates of all involved quantities without the need of ad hoc uncertainty contributions. We describe how low-resolution data products, including dense pixel-pixel covariance matrices, may be produced from the posterior samples directly, without the need for computationally expensive analytic calculations or simulations. We conclude that posterior-based frequency map sampling provides unique capabilities in terms of low-level systematics modeling and error propagation, and may play an important role for future Cosmic Microwave Background (CMB) B-mode experiments aiming at nanokelvin precision.

79 ASTRONOMY AND ASTROPHYSICS↗

BeyondPlanck: I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BEYONDPLANCK project in terms of our motivation, methodology, and main products, and provide a guide to a set of companion papers that describe each result in more detail. Building directly on experience from ESA’s Planck mission, we implemented a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a full joint posterior distribution P(ω | d), where ω represents the set of all free instrumental (gain, correlated noise, bandpass, etc.), astrophysical (synchrotron, free-free, thermal dust emission, etc.), and cosmological (cosmic microwave background – CMB – map, power spectrum, etc.) parameters. Some notable advantages of this approach compared to a traditional pipeline procedure are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-ℓ CMB polarization reconstruction with Planck LFI. In this process, we identify several important new effects that have not been accounted for in previous pipelines, including gain over-smoothing and time-variable and non-1/f correlated noise in the 30 and 44 GHz channels. Modeling and mitigating both previously known and newly discovered systematic effects, we find that all results are consistent with the ΛCDM model, and we constrained the reionization optical depth to τ = 0.066 ± 0.013, with a low-resolution CMB-based χ 2 probability to exceed of 32%. This uncertainty is about 30% larger than the official pipelines, arising from taking a more complete instrumental model into account. The marginal CMB solar dipole amplitude is 3362.7 ± 1.4 μK, where the error bar was derived directly from the posterior distribution without the need of any ad hoc instrumental corrections. We are currently not aware of any significant unmodeled systematic effects remaining in the Planck LFI data, and, for the first time, the 44 GHz channel is fully exploited in the current analysis. We argue that this framework can play a central role in the analysis of many current and future high-sensitivity CMB experiments, including LiteBIRD, and it will serve as the computational foundation of the emerging community-wide COSMOGLOBE effort, which aims to combine state-of-the-art radio, microwave, and submillimeter data sets into one global astrophysical model.

79 ASTRONOMY AND ASTROPHYSICS↗

The superTIGER instrument: Measurement of elemental abundances of ultra-heavy galactic cosmic rays

The SuperTIGER (Super Trans-Iron Galactic Element Recorder) instrument was developed to measure the abundances of galactic cosmic-ray elements from {sub 10}Ne to {sub 40}Zr with individual element resolution and the high statistics needed to test models of cosmic-ray origins. SuperTIGER also makes exploratory measurements of the abundances of elements with 40 < Z ≤ 60 and measures the energy spectra of the more abundant elements for Z ≤ 30 from about 0.8 to 10 GeV/nucleon. This instrument is an enlarged and higher resolution version of the earlier TIGER instrument. It was designed to provide the largest geometric acceptance possible and to reach as high an altitude as possible, flying on a standard long-duration 1.11 million m{sup 3} balloon. SuperTIGER was launched from Williams Field, McMurdo Station, Antarctica, on 2012 December 8, and made about 2.7 revolutions around the South Pole in 55 days of flight, returning data on over 50 × 10{sup 6} cosmic-ray nuclei with Z ≥ 10, including ∼1300 with Z > 29 and ∼60 with Z > 49. Here, we describe the instrument, the methods of charge identification employed, the SuperTIGER balloon flight, and the instrument performance.

79 ASTRONOMY AND ASTROPHYSICS↗

A BLIND METHOD TO DETREND INSTRUMENTAL SYSTEMATICS IN EXOPLANETARY LIGHT CURVES

The study of the atmospheres of transiting exoplanets requires a photometric precision, and repeatability, of one part in ∼10{sup 4}. This is beyond the original calibration plans of current observatories, hence the necessity to disentangle the instrumental systematics from the astrophysical signals in raw data sets. Most methods used in the literature are based on an approximate instrument model. The choice of parameters of the model and their functional forms can sometimes be subjective, causing controversies in the literature. Recently, Morello et al. (2014, 2015) have developed a non-parametric detrending method that gave coherent and repeatable results when applied to Spitzer/IRAC data sets that were debated in the literature. Said method is based on independent component analysis (ICA) of individual pixel time-series, hereafter “pixel-ICA”. The main purpose of this paper is to investigate the limits and advantages of pixel-ICA on a series of simulated data sets with different instrument properties, and a range of jitter timescales and shapes, non-stationarity, sudden change points, etc. The performances of pixel-ICA are compared against the ones of other methods, in particular polynomial centroid division, and pixel-level decorrelation method. We find that in simulated cases pixel-ICA performs as well or better than other methods, and it also guarantees a higher degree of objectivity, because of its purely statistical foundation with no prior information on the instrument systematics. The results of this paper, together with previous analyses of Spitzer/IRAC data sets, suggest that photometric precision and repeatability of one part in 10{sup 4} can be achieved with current infrared space instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Incompatibility as a Resource for Programmable Quantum Instruments

Quantum instruments represent the most general type of quantum measurement, as they incorporate processes with both classical and quantum outputs. In many scenarios, it may be desirable to have some “on-demand” device that is capable of implementing one of many possible instruments whenever the experimenter desires. We refer to such objects as programmable instrument devices (PIDs), and this paper studies PIDs from a resource-theoretic perspective. A physically important class of PIDs are those that do not require quantum memories to implement, and these are naturally “free” in this resource theory. Additionally, these free objects correspond precisely to the class of unsteerable channel assemblages in the study of channel steering. The traditional notion of measurement incompatibility emerges as a resource in this theory since any PID controlling an incompatible family of instruments requires a quantum memory to build. We identify an incompatibility preorder between PIDs based on whether one can be transformed into another using processes that do not require additional quantum memories. Necessary and sufficient conditions are derived for when such transformations are possible based on how well certain guessing games can be played using a given PID. Ultimately our results provide an operational characterization of incompatibility, and they offer semi-device-independent tests for incompatibility in the most general types of quantum instruments. Published by the American Physical Society 2024

Physics↗

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)↗

Technical Challenges and Gaps in Integration of Advanced Sensors, Instrumentation, and Communication Technologies with Digital Twins for Nuclear Application

This paper explores integrating advanced sensor, instrumentation, and communication technologies with digital twin technologies for nuclear energy application. Digital twins and digital-twin-enabling technologies are expected to integrate with future nuclear reactor designs and have the potential to impact currently operating nuclear power plants. Greater digital integration, advanced instrumentation and control systems, and advanced operations and maintenance practices are all associated with digital-twin-enabling technologies. Advanced sensors, instrumentation, and communication technology are expected to comprise important elements of the infrastructure required to develop and operate a nuclear digital twin system. This paper identifies and discusses challenges and gaps in developing and implementing advanced sensors and instrumentation and communication technology to be integrated with a digital twin in current and advanced reactor applications. It is important to address some challenge and gap to enable a successful near-term deploying advanced sensors, instrumentation, and communication technologies integrated with digital twins.

Yadav, Vaibhav↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Instrumental phase-based method for Fourier transform spectrometer measurements processing

Phase correction is a critical procedure for most space-borne Fourier transform spectrometers (FTSs) whose accuracy (owing to often poor signal-to-noise ratio, SNR) can be jeopardized from many uncontrollable environmental conditions. This work considers the phase correction in an FTS working under significant temperature change during the measurement and affected by mechanical disturbances. The implemented method is based on the identification of an instrumental phase that is dependent on the interferometer temperature and on the extraction of a linear phase component through a least-squares approach. The use of an instrumental phase parameterized with the interferometer temperature eases the determination of the linear phase that can be extracted using only a narrow spectral region selected to be immune from disturbances. The procedure, in this way, is made robust against phase errors arising from instrumental effects, a key feature to reduce the disturbances through spectra averaging. The method was specifically developed for the Mars IR Mapper spectrometer, that was designed for operation onboard a rover on the Mars surface; the validation was performed using ground and in-flight measurements of the Fourier transform IR spectrometer planetary Fourier spectrometer, onboard the MarsExpress mission. The symmetrization has been exploited also for the spectra calibration, highlighting the issues deriving from the cases of relevant beamsplitter emission. The applicability of this procedure to other instruments is conditional to the presence in the spectra of at least one spectral region with a large SNR along with a negligible (or known) beamsplitter emission. For the PFS instrument, the processing of data with relevant beamsplitter emission has been performed exploiting the absorption carbon dioxide bands present in Martian spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ARM Climate Research Facility Quarterly Instrument Report Fourth Quarter: October 1–December 30, 2010

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Optical Depth Value-Added Product for the SAS-He Instrument

The Shortwave Array Spectroradiometer – Hemispheric (SAS-He) is a ground-based, shadowband instrument that measures the direct and diffuse solar irradiance. In this regard, the instrument is similar to the Multi-Filter Rotating Shadowband Radiometer (MFRSR) – an instrument that has been in the ARM suite of instruments for more than 15 years. However, the two instruments differ significantly in wavelength resolution and range. In particular, the MFRSR only observes the spectrum in six discrete wavelength channels of about 10 nm width from 415 to 940 nm. The SAS-He, in contrast, incorporates two fiber-coupled grating spectrometers: a Si CCD spectrometer with over 2000 pixels covering the range from 325-1040 nm with ~ 2.5 nm resolution ,and an InGaAs array spectrometer with 256 pixels covering the wavelength range from 960-1700 nm with ~ 6 nm resolution.

Ermold, B↗

Wind Energy Instrumentation Atlas

The US Department of Energy (DOE) A2e program is focused on developing the next generation of predictive tools to better understand wind plant performance and help industry lower the overall cost of energy. A formal verification and validation process is required to demonstrate improved accuracy of these new models beyond those currently employed. And a critical part of model validation is utilization of a diverse set of accurate observations of atmospheric forcing and wind plant response. A number of existing data sets that will be used for this purpose, as highlighted by Schreck and Maniaci (2017) but A2e researchers also realize that new datasets will be required to meet validation objectives. As such, plans for new experiments based on model validation priorities (NALU validation plan, 2017) are currently being developed. This document is intended to serve as a reference to experimental study planners that describes the capability, accuracy and resolution of existing and developing measurement technologies to observe quantities of interest for wind plant model validation. Such systems can be broken into two major categories: those that measure the flow field and surrounding atmosphere around and within a wind plant and those that measure the turbine response within the wind plant. The A2e validation team will use this catalogue of instrument capability in conjunction with the validation plan, to choose the optimal set of instruments to be deployed, inform instrument placement and operation and estimate the types of validation that may be gathered through new field campaigns. Where existing instrumentation is deficient, the document will also help guide DOE towards potential areas where instrumentation development is required to meet validation objectives and A2e technology development funding may be required. The domain of interest is the wind plant microscale, within and surrounding a single wind plant, typically, tens of kilometers on a side in horizontal directions and to the top of the atmospheric boundary layer (about 1km) in the vertical. Some observations of dominant mesoscale forcing phenomena are required, with the highest resolution measurements occurring in the wind turbine wakes and on the turbines themselves. The simulation tools to be validated are mesoscale driven large-eddy simulations of the atmosphere with full aeroelastic response of individual turbines within the plant. Use cases vary slightly among tool users, but should focus on the primary end customers of the simulations and research insights, which would be turbine manufacturers, wind plant developers and owners. Broadly speaking their interests are maximizing energy output, while maintaining turbine reliability and lifetime.

17 WIND ENERGY↗

Kilonova Detectability with Wide-Field Instruments [Slides]

A diverse set of instruments increase the chances of detecting and identifying a kilonova. Early observations increase the probability of detection. More sensitive wide-field ultraviolet instruments are needed as GW detectors reach design sensitivity. There is a dearth of wide-field infrared instruments. These results are useful for guiding kilonova searches following a GW detection and sGRD observation, proposals for time on current and upcoming instruments, and planning future wide-field instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Shielding development for the VENUS imaging instrument

VENUS is an imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold, will include enhanced contrast mechanisms, and will offer novel energy-selective imaging techniques that directly connect the structures, properties, and function of complex engineering materials and systems to reveal practical and fundamental answers about their real-world performance. The instrument is to be built at SNS beam line 10 and will face the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beam line and instrument cave shielding. Initial scoping analyses were performed to estimate thickness and composition of shielding materials for the instrument cave and beam line. In light of the upcoming Proton Power Upgrade (PPU) project, these transport analyses were performed for proton beam on target at 1.3 GeV and 2 MW.

Popova, Irina I.↗

Development of an in situ dual-channel thermal desorption gas chromatography instrument for consistent quantification of volatile, intermediate-volatility and semivolatile organic compounds

Abstract. Aerosols are a source of great uncertainty in radiative forcing predictions and have poorly understood health impacts. Most aerosol mass is formed in the atmosphere from reactive gas-phase organic precursors, forming secondary organic aerosol (SOA). Semivolatile organic compounds (SVOCs) (effective saturation concentration, C*, of 10−1–103 µg m−3) comprise a large fraction of organic aerosol, while intermediate-volatility organic compounds (IVOCs) (C* of 103–106 µg m−3) and volatile organic compounds (VOCs) (C* ≥ 106 µg m−3) are gas-phase precursors to SOA and ozone. The Comprehensive Thermal Desorption Aerosol Gas Chromatograph (cTAG) is the first single instrument simultaneously quantitative for a broad range of compound-specific VOCs, IVOCs and SVOCs. cTAG is a two-channel instrument which measures concentrations of C5–C16 alkane-equivalent-volatility VOCs and IVOCs on one channel and C14–C32 SVOCs on the other coupled to a single high-resolution time-of-flight mass spectrometer, achieving consistent quantification across 15 orders of magnitude of vapor pressure. cTAG obtains concentrations hourly and gas–particle partitioning for SVOCs every other hour, enabling observation of the evolution of these species through oxidation and partitioning into the particle phase. Online derivatization for the SVOC channel enables detection of more polar and oxidized species. In this work we present design details and data evaluating key parameters of instrument performance such as I/VOC collector design optimization, linearity and reproducibility of calibration curves obtained using a custom liquid evaporation system for I/VOCs and the effect of an ozone removal filter on instrument performance. Example timelines of precursors with secondary products are shown, and analysis of a subset of compounds detectable by cTAG demonstrates some of the analytical possibilities with this instrument.

54 ENVIRONMENTAL SCIENCES↗

Analysis of instrumentation error effects on the identification accuracy of aircraft parameters

An analytical investigation is presented of the effect of unmodeled measurement system errors on the accuracy of aircraft stability and control derivatives identified from flight test data. Such error sources include biases, scale factor errors, instrument position errors, misalignments, and instrument dynamics. Two techniques (ensemble analysis and simulated data analysis) are formulated to determine the quantitative variations to the identified parameters resulting from the unmodeled instrumentation errors. The parameter accuracy that would result from flight tests of the F-4C aircraft with typical quality instrumentation is determined using these techniques. It is shown that unmodeled instrument errors can greatly increase the uncertainty in the value of the identified parameters. General recommendations are made of procedures to be followed to insure that the measurement system associated with identifying stability and control derivatives from flight test provides sufficient accuracy.

Sorensen, J. A.↗

Earth Observatory Satellite system definition study. Report 2: Instrument constraints and interfaces

The instrument constraints and interface specifications for the Earth Observatory Satellite (EOS) are discussed. The Land Use Classification Mission using a 7 band Thematic Mapper and a 4 band High Resolution Pointable Imager is stressed. The mission and performance of the instruments were reviewed and expanded to reflect the instrument as a part of the total remote sensing system. A preliminary EOS interface handbook is provided to describe the mission and system, to specify the spacecraft interfaces to potential instrument contractors, and to describe the instrument interface data required by the system integration contractor.

Source record↗