Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study

Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.

47 OTHER INSTRUMENTATION↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pycheron: A Python-Based Seismic Waveform Data Quality Control Software Package

Supplementing an existing high-quality seismic monitoring network with openly available station data could improve coverage and decrease magnitudes of completeness; however, this can present challenges when varying levels of data quality exist. Without discerning the quality of openly available data, using it poses significant data management, analysis, and interpretation issues. Incorporating additional stations without properly identifying and mitigating data quality problems can degrade overall monitoring capability. If openly available stations are to be used routinely, a robust, automated data quality assessment for a wide range of quality control (QC) issues is essential. To meet this need, we developed Pycheron, a Python-based library for QC of seismic waveform data. Pycheron was initially based on the Incorporated Research Institutions for Seismology’s Modular Utility for STAtistical kNowledge Gathering but has been expanded to include more functionality. Pycheron can be implemented at the beginning of a data processing pipeline or can process stand-alone data sets. Its objectives are to (1) identify specific QC issues; (2) automatically assess data quality and instrumentation health; (3) serve as a basic service that all data processing builds on by alerting downstream processing algorithms to any quality degradation; and (4) improve our ability to process orders of magnitudes more data through performance optimizations. This article provides an overview of Pycheron, its features, basic workflow, and an example application using a synthetic QC data set.

58 GEOSCIENCES↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. For this reason, recent studies have investigated autonomous control by using adaptive model predictive control and multi-objective optimization for heat pipe–cooled microreactors under normal and heat pipe failure conditions. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this poster, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

Mechanisms of ultrafast GHz burst fs laser ablation

Gigahertz (GHz) femtosecond (fs) lasers have opened possibilities for enhancing and controlling the laser machining quality to engineer the physicochemical properties of materials. However, fundamental understanding of laser-material interactions by GHz fs laser has remained unsolved due to the complexity of associated ablation dynamics. Here, we study the ablation dynamics of copper (Cu) by GHz fs bursts using in situ multimodal diagnostics, time-resolved scattering imaging, emission imaging, and emission spectroscopy. A combination of probing techniques reveals that GHz fs bursts rapidly remove molten Cu from the irradiated spot due to the recoil pressure exerted by following fs pulses. Material ejection essentially stops right after the burst irradiation due to the limited amount of remnant matter, combined with the suppressed heat conduction into the target material. Our work provides insights into the complex ablation mechanisms incurred by GHz fs bursts, which are critical in selecting optimal laser conditions in cross-cutting processing, micro/nano-fabrication, and spectroscopy applications.

47 OTHER INSTRUMENTATION↗

Design and Characterization of a Burst Mode 20 Mfps Low Noise CMOS Image Sensor

This paper presents a novel ultra-high speed, high conversion-gain, low noise CMOS image sensor (CIS) based on charge-sweep transfer gates implemented in a standard 180 nm CIS process. Through the optimization of the photodiode geometry and the utilization of charge-sweep transfer gates, the proposed pixels achieve a charge transfer time of less than 10 ns without requiring any process modifications. Moreover, the gate structure significantly reduces the floating diffusion capacitance, resulting in an increased conversion gain of 183 µV/e−. This advancement enables the image sensor to achieve the lowest reported noise of 5.1 e− rms. To demonstrate the effectiveness of both optimizations, a proof-of-concept CMOS image sensor is designed, taped-out and characterized.

47 OTHER INSTRUMENTATION↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An iterative CMB lensing estimator minimizing instrumental noise bias

Noise maps from cosmic microwave background (CMB) experiments are generally statistically anisotropic, due to scanning strategies, atmospheric conditions, or instrumental effects. Any mismodeling of this complex noise can bias the reconstruction of the lensing potential and the measurement of the lensing power spectrum from the observed CMB maps. We introduce a new CMB lensing estimator based on the maximum (MAP) reconstruction that is minimally sensitive to these instrumental noise biases. By modifying the likelihood to rely exclusively on correlations between CMB map splits with independent noise realizations, we minimize autocorrelations that contribute to biases. In the regime of many independent splits, this maximum closely approximates the optimal MAP reconstruction of the lensing potential. In simulations, we demonstrate that this method is able to determine lensing observables that are immune to any noise mismodeling with a negligible cost in signal-to-noise ratio. Our estimator enables unbiased and nearly optimal lensing reconstruction for next-generation CMB surveys.

Legrand, Louis [University of Cambridge (United Ki↗