Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

NSUF RTE completion report for 23-4780: Microstructural Defect Induced Thermal Conductivity Reduction in Uranium Nitride and Thorium Nitride

Uranium nitride (UN) is known to have a higher thermal conductivity than traditional oxide fuels, which could lead to a more efficient energy transport and lower local temperature during its lifetime. But the thermal transport performance of UN in extreme environments has not been systematic studied. This study investigated the irradiation induced microstructural defects in UN and the impacts on thermal conductivity. The samples were produced by spark plasma sintering at University of Texas-San Antonio (UTSA), Los Alamos National Laboratory (LANL), and Idaho National Laboratory (INL). Thermal conductivity of UN before and after 2MeV proton irradiation were measured by using laser metrology at INL in a temperature range of 77-295K. Thermal conductivity measurements in this wide, cryogenic temperature range is critical to understand the phonon scattering mechanisms between the thermal energy carrier, phonons, and different types of irradiation-induced defects. In order to ensure the measurements were conducted in the same grains and minimize the impact of the local heterogeneities, the measurement locations were highlighted by fiducial marks using the focused ion beam (FIB) with grain orientation identified using the electron backscatter diffraction (EBSD) at the Center of Advanced Energy Studies (CAES). Irradiation experiment was conducted at the Ion Beam Laboratory at Texas A&M University (TAMU). A total of 6 samples were irradiated with different irradiation doses and temperatures. After irradiation, the microstructure was characterized by using Transmission Electron Microscope (TEM) at CAES (also in the FIB marks).

36 - MATERIALS SCIENCE↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bridging the length scales on mechanical property evaluation (Final Report)

The development of small-scale mechanical testing in combination with microstructural investigation is of great interest to the nuclear materials community for both materials development and monitoring applications. Dramatically reducing the sample sizes to reduce radioactivity and obtaining mechanical properties of irradiated samples is truly intriguing. Moreover, such studies promise a range of benefits including cost reduction, fundamental insight in structure-property relationships, increased statistics on less sample material, and reinvestigation of prior irradiated and tested reactor samples while simultaneously enabling the generation of mechanical test data on ion beam irradiated materials with limited penetration depths. Small scale materials testing on sub-sized samples has been studied for several decades, though it has only been after the development of micro-testing based on Focused Ion Beam (FIB) sample manufacturing in that orders of magnitude smaller samples could really be investigated in a quantitative manner. In recent years, small scale mechanical testing techniques at a number of length scales has been developed for both unirradiated and irradiated (ion and neutron) materials. Technological advances made in this field have enabled ex-situ and in-situ transmission electron microscopy (TEM) and scanning electron microscopy (SEM) examination, thus leading to more accurate measurements as well as additional mechanistic information. A recent review of the benefits of these techniques show that these techniques are at a stage to tackle multi-scale ranges of materials investigations and can be utilized to obtain fundamental science-based understanding of nuclear materials. Considering the tremendous advances made, one can see how small-scale mechanical testing techniques combined with modeling can enable true small scale to bulk scale mechanical property correlations. However, for the engineering community to adapt this approach fully, one needs to demonstrate that a) that these techniques can produce results with high fidelity and reproducibility, b) generate engineering stress-strain data that one can utilize to understand bulk behavior, and c) generate new insight into relevant phenomena fostering the true understanding of radiation damage and microstructure in materials for nuclear applications. It is the objective of this proposal to bridge the length scale between macro- and micro- scale mechanical testing of unirradiated and irradiated materials. This involves the development and demonstration of procedures for multi-scale mechanical testing that enable high fidelity reproducibility of data and the generation bulk property data from small-scale mechanical tests. Through this, the proposal aims to enhance the confidence in the obtained data at the smaller length scales and enhance the insight provided from these techniques for bulk scale applications on both unirradiated and irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

β decay of neutron-rich 76 Cu and the structure of 76 Zn

In this work, the β decay of 76 Cu to the levels of 76 Zn was studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). A purified 76 Cu beam was developed and data were recorded for the decay of the A=76 decay chain using four high-purity germanium (HPGe) clover detectors at the Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS). In this measurement, data on γ-ray emission following β decay, including βγ and γγ coincidences, were collected and γγ spectra were analyzed to identify the statistically significant coincidences. From this analysis, we propose a level scheme for 76 Zn which contains a total of 59 energy levels up to 6.0 MeV containing 105 γ rays. We have identified an additional 53 γ rays associated with this decay which could not be place in the decay scheme due to insufficient coincidence information or no energy match to identified levels. No γ rays from states in 75 Zn fed in the delayed-neutron branch were observed even though other γ rays in the A=75 decay chain were observed. Spin and parity assignments are proposed for some levels based on comparison to systematics and shell model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ytterbium Ion Collection on Graphite Plates

Surface characterization and analysis of the graphite collection and strike plates was conducted in this report. These plates were from an electromagnetic isotope separation collector that had been irradiated with an ytterbium ion beam. The results of this study are reported along with analysis and discussion of the potential growth mechanism of the ytterbium layer on graphite. It is proposed that directional deposition of ytterbium ions occurs first in the defect regions of the graphite plate. As deposition continues, it leads to the eventual formation of directional globs that elongate and grow into plates, then stacks, and finally into sheets of ytterbium. The ytterbium layer appears to have a definite phase boundary with the graphite layer. It was also determined that during irradiation with the ytterbium ion beam, the sputtered carbon becomes interpolated in the ytterbium surface layer on the graphite plate and has an amorphous microstructure.

36 MATERIALS SCIENCE↗

Comparison of PID Shunting in Polycrystalline and Single-Crystal Silicon Modules via Multi-Scale, Multi-Technique Characterization

We used the methods we reported last year to investigate potential-induced degradation (PID). We have now applied these methods to single-crystalline silicon modules that have degraded during field deployment, as well as in minimodules stressed in the laboratory. We will compare these results to the polycrystalline results presented last year. Small cores have been removed from the modules and subjected to analysis. We use a combination of photoluminescence and dark lock-in thermography imaging, laser marking, electron-beam induced current measurements, and subsequent focused ion-beam marking to allow analysis of individual defects via time-of-flight secondary-ion mass spectrometry (TOF-SIMS) to investigate the root-cause mechanism for PID shunting. We see a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiN/Si interface and is consistently observed at a concentration of 0.1%-1% in shunted areas. TOF-SIMS data taken on degraded and non-degraded single-crystalline sample areas show a similar trend as in the polycrystalline samples: more sodium is seen in the degraded areas.

14 SOLAR ENERGY↗

Laser-driven collisionless shock acceleration of ions from near-critical plasmas

Here, this paper overviews experimental and numerical results on acceleration of narrow energy spread ion beams by an electrostatic collisionless shockwave driven by 1 μm (Omega EP) and 10 μm (UCLA Neptune Laboratory) lasers in near critical density CH and He plasmas, respectively. Shock waves in CH targets produced high-energy ~50 MeV protons (ΔE/E of ≤30%) and 314 MeV C 6+ ions (ΔE/E of ≤10%). Observation of acceleration of both protons and carbon ions to similar velocities is consistent with reflection of particles off the moving potential of a shock front. For shocks driven by CO 2 laser in a gas jet, ~30 MeV peak in He ion spectrum was detected. Particle-in-cell simulations indicate that regardless of the target further control over its density profile is needed for optimization of accelerated ion beams in part of energy spread, yield and maximum kinetic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space Charge Effects in Low Energy Magnetized Electron Beams

Magnetized electron cooling of the ion beam is one of the major approaches towards obtaining the required high luminosity in the proposed Electron-Ion Collider (EIC). To increase the cooling efficiency, a bunched electron beam with a high bunch charge and high repetition rate is required. However, these features can combine to enhance the collective interactions, such as the space charge effect. A magnetized electron beam was successfully generated at the Thomas Jefferson National Accelerator Facility (JLab) using a compact, 300 kV DC high voltage photo-gun with an inverted insulator geometry and bi-alkali antimonide photocathode. The beam magnetization was characterized using a modest diagnostic beamline to measure beam sizes, rotation angles, and normalized transverse emittance as a function of magnetic field at the photocathode, laser spot size, and gun high-voltage. Simultaneously, simulations were performed using the A Space Charge Tracking Algorithm (ASTRA) and General Particle Tracer (GPT) programs. Further, sustained high average current magnetized beam up to 28 mA was demonstrated, and the photocathode lifetime for different magnetized electron beam currents was investigated. In the second part of the project, the space charge effect in low-energy magnetized electron beams was studied and compared with GPT simulations. The high bunch charge studies showed evidence of space charge current limitations starting at 0.3 nC and limited the maximum delivered bunch charge to 0.7 nC. To reach the high bunch charge goal of a few nC, the existing DC photo-gun design was modified using CST Studio Suite’s electromagnetic field solver, and a way to cancel the beam deflection exerted by the non-symmetric nature of the inverted insulator photo-gun geometry was discovered. This thesis presents a detailed description of the generation, characterization, and simulation of high current, high bunch charge magnetized electron beams at JLab, as well as the modified photo-gun design. Together with measurements and simulations, the purpose of this thesis is to provide a solid background on the theoretical aspects and the experimental challenges associated with magnetized electron beams for accelerator applications.

Wijethunga, W M Sajini↗

Isotopic mass effects of tritium-fueled high-performance TFTR supershots

An increase in total stored energy correlated with the addition of tritium fuel was observed in supershots during the TFTR DT campaign. This supershot regime had strikingly high, centrally peaked ion and electron temperatures, and the largest neutron emission rates observed in TFTR. This paper presents a study of the causes of this increase in stored energy in supershots. Twenty-six supershots have been recently reanalyzed with the TRANSP plasma analysis code. Early TRANSP simulations did not accurately match the measured magnitude and time evolutions of the neutron emission rates. This mismatch is attributed to neglecting apparent increases of trace amounts of heavy impurities during neutral beam injection. The new TRANSP runs were tuned to accommodate this and match the measured global neutron emission rates. These new runs also had improved fidelity in predicting the time histories and radial dependencies of measured DT neutron emission rates. That in turn adds confidence in the simulated thermal deuterium and tritium density profiles that are needed for calculating the average hydrogenic atomic mass profiles. Six subsets of these supershots had well matched toroidal field B tor , plasma current I p , flux geometry, and total injected neutral beam power. The mix of D and T beam ions was varied for different discharges. The magnitude of the increase of the thermal ion energy W i with added tritium was relatively small, and the total W tot increase is dominated by the increase in fast beam ions with T. Analyses at times before the occurrences of deleterious MHD instabilities yielded scaling of W tot with the volume-average isotopic mass consistent with previous publications. The relative fraction of fast energy ions is expected to be small in practical tokamak reactors. Thus the increase in stored energy W tot observed in TFTR supershots does not appear likely to be significantly helpful for producing useful fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiscale Cryo Electron Microscopy Reveals Interfacial Degradation and Stabilization in Battery Electrodes

Electrochemical interfaces are dynamic systems, evolving based on their local environment and reactant surface structures. The electrode-electrolyte interface in Li-ion batteries can be protective, limiting parasitic reactions with the electrolyte to passivate the surface [1]. Additionally, this interphase has an impact on the Li-ion transport through that layer based on its composition, bonding environment, and thickness. These parameters are challenging to collect and may vary depending on the electrode surface site investigated relative to its spatial position in a coin cell. This study will detail a multiscale cryogenic electron microscopy approach where millimeter-scale cross-sections through the coin cell batteries were made using a cryogenic stage within a fs-laser plasma focused ion beam (laser PFIB) with complementary energy dispersive X-ray spectroscopy able to detect variations in the composition at electrode interfaces [2]. Microscale cross-sectioning and lamella sample preparation of battery electrodes was conducted at the Center for Integrated Nanotechnologies using a Ga-ion focused ion beam (FIB) with air-free and cryo-transfer [3], followed by nanoscale mapping of composition and bonding within the CEI through cryo-scanning transmission electron microscopy (cryo-STEM) electron energy loss spectroscopy [4]. This multiscale approach enabled identification of millimeter-scale features of a battery stack with visualization of degradation in electrodes such as cracks in cathode particles, gas evolution, and SEI evolution; microscale interfacial characteristics, such as heterogeneity in the SEI or barrier layer and identification of electrolyte networks to the electrode surfaces; and nanoscale measurement of the CEI thickness, mapping of transition metal bonding within the cathode particles to identify loss of active materials, and identification of beneficial electrolyte additives incorporated into the CEI structure. This multiscale approach allows for a statistical understanding of the primary mechanisms and parasitic degradation pathways that impact performance by limiting the ion transport pathways within Li+ batteries.

36 MATERIALS SCIENCE↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

The role of chalcogen vacancies for atomic defect emission in MoS 2

For two-dimensional (2D) layered semiconductors, control over atomic defects and understanding of their electronic and optical functionality represent major challenges towards developing a mature semiconductor technology using such materials. Here, we correlate generation, optical spectroscopy, atomic resolution imaging, and ab initio theory of chalcogen vacancies in monolayer MoS 2 . Chalcogen vacancies are selectively generated by in-vacuo annealing, but also focused ion beam exposure. The defect generation rate, atomic imaging and the optical signatures support this claim. We discriminate the narrow linewidth photoluminescence signatures of vacancies, resulting predominantly from localized defect orbitals, from broad luminescence features in the same spectral range, resulting from adsorbates. Vacancies can be patterned with a precision below 10 nm by ion beams, show single photon emission, and open the possibility for advanced defect engineering of 2D semiconductors at the ultimate scale.

36 MATERIALS SCIENCE↗

Cytochrome Nanowire XRD

Microbial metabolism plays an important role in the global cycling of carbon, nutrients, and metals. Recent discovery of microorganisms sharing energy using direct electrical connections might represent a prominent strategy by which anaerobic microorganisms interact with the diversity of environments. The purpose of the proposed research is to apply these newly developed principles of electron exchange in microbial communities to the study of biogeochemical cycling in climate and subsurface systems. Previous studies revealed that soil bacteria Geobacter sulfurreducens produce conductive pili nanofilaments that facilitate long-range electron transport to extracellular electron acceptors and other cells. This discovery has already transformed our understanding of the function of microbial communities in diverse environments, making basic contributions to microbial ecology and helping to improve practical applications such as increasing current output of microbial fuel cells and enhancing the conversion of organic waste to methane. Microbial electron exchange via pili may also contribute to methane production in terrestrial environments that are major sources of atmospheric methane. However, the mechanism of electron transport through pili is not well understood. Initial studies have suggested that pili exhibit metallic-like conductivity similar to conducting polymer polyaniline. However, these studies were limited to electrical measurements. X-ray diffraction studies have suggested that aromatic amino acids tyrosine and phenylalanine are closely packed in pili. But these studies used homology modeling to predict the pilus assembly and information about the number of monomers in each pilus assembly unit and their organization are still lacking. The central hypothesis of this proposal is aromatics in pili enable intermolecular electron delocalization due to pi-stacking that can give rise to metallic-like conductivity. By analyzing pili structure using infrared scattering-scanning near field optical microscope (IR s-SNOM) and combining with solution NMR, Focused Ion Beam (FIB and computational capabilities, this work will provide comprehensive understanding of the conduction mechanism from a structure-function perspective. The specific aims are: 1) With infrared scattering scanning near field optical microscope (IR s-SNOM), image the organization and density of pilin monomers and pH-induced conformational changes in a pilus filament. 2) With solution NMR, resolve pH-induced structural changes in the pilin monomer. 3) Using Focused Ion Beam (FIB), draw electrodes on single pili to measure their conductivity. 4) With computational modeling using the NWChem, simulate the effect of environment on the electronic properties of pili as a function of pH. The proposed work will gain the nanoscale insight into the structure of the pili, as the basis for understanding interspecies electrical communications. The improved understanding will be harnessed to accelerate bioenergy production and bioremediation using pili as well as for predictive modeling of carbon cycling in diverse environments to reach the central goals of DOE-BER to develop sustainable energy sources, regulate the contaminants in the subsurface and understand the effects of greenhouse gas emissions on biosphere. The proposed studies will provide design principles for engineering of electrical interactions among these communities by manipulating the amino acid composition of pili. Moreover, these studies will identify the forces that maintain the function of these communities in the face of environmental perturbation. Therefore, these studies will help to address the need "to incorporate process understanding of biogeochemical cycling into a scalable hierarchy of predictive capabilities" specified in EMSL's Science Themes.

59 BASIC BIOLOGICAL SCIENCES↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Creation of color centers in diamond by recoil implantation through dielectric films

The need of near-surface color centers in diamond for quantum technologies motivates the controlled doping of specific extrinsic impurities into the crystal lattice. Further, recent experiments have shown that this can be achieved by momentum transfer from a surface precursor via ion implantation, an approach known as “recoil implantation.” Here, we extend this technique to incorporate dielectric precursors for creating nitrogen-vacancy (NV) and silicon-vacancy (SiV) centers in diamond. Specifically, we demonstrate that gallium focused-ion-beam exposure to a thin layer of silicon nitride or silicon dioxide on the diamond surface results in the introduction of both extrinsic impurities and carbon vacancies. These defects subsequently give rise to near-surface NV and SiV centers with desirable properties after annealing.

42 ENGINEERING↗

Recent Developments in Femtosecond Laser-Enabled TriBeam Systems

Streams of multimodal three-dimensional (3D) and four-dimensional (4D) data are revolutionizing our ability to design and predict the behavior of a broad array of advanced materials systems. Over the last 10 years, a new 3D imaging platform consisting of a femtosecond (fs) pulsed laser coupled with a focused ion beam scanning electron microscope (FIB SEM) has been developed by UC Santa Barbara in collaboration with Thermo Fisher Scientific (formerly FEI). The femtosecond-laser-enabled FIB SEM, called the TriBeam, has become one of the only 3D serial sectioning methods available that can gather millimeter-scaled multimodal datasets at sub-μm voxel resolutions; these length scales are critical for many materials problems. Multimodal chemical, crystallographic, and morphological information can be gathered rapidly on a layer-by-layer basis and reconstructed in 3D. Large (gigabyte to terabyte scale) 3D datasets have been generated for a broad array of materials systems, including metallic alloys, ceramics, biomaterials, polymer- and ceramic-matrix composites, and semiconductors. The research tasks conducted have resulted in a completely new design, operating with a dual-wavelength femtosecond-pulsed laser on a plasma focused ion beam (PFIB) platform.

36 MATERIALS SCIENCE↗

Birefringent Glass‐Engraved Quasi‐Linear Nanograting Metasurface Based on Self‐Organizing Process for Large Aperture High Power Laser Applications

All-glass metasurface “nanograting” structures that exhibit birefringence in the formed layer are reported. The key enabler of this work is ion beam processing at an angle sufficiently off-normal incidence, inducing self-assembly of a deposited metal layer into quasi-linear metallic features that can function as an etching mask. As a result, a fused silica metasurface, monolithic to the underlying substrate, is demonstrated at 375 nm wavelength to exhibit a phase delay angle of 30° between the principal axes. The capability of an angled etch mask replenishment process is also demonstrated for achieving deeper etch depth and for increasing the grating period, another first – to the best of the knowledge. This is the first display of a technology capable of fabricating glass-engraved near-linear grating structure with a feature-to-feature period as small as 118.6 nm. Furthermore, this technology has the potential to generate grating-like structures with periods as small as 12.4 nm, as demonstrated here with reactive ion beam processing assisted mask assembly. Furthermore, these structures are shown to have reflectivity < 0.4% across the wavelength band 350 nm – 1000 nm. Such a technology can enable laser-durable grating structures for the deep-UV and even down to soft X-ray wavelengths.

Ray, Nathan J. [Lawrence Livermore National Labora↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗