Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Complete Phase Transformation of Ir Nanowire Network into Defect-Rich Oxide Catalyst for High-Performance PEM Water Electrolysis

Iridium-based catalysts remain the most reliable option for the oxygen evolution reaction (OER) in proton exchange membrane water electrolyzers (PEMWEs). However, their high cost and limited performance represent critical barriers to the commercialization of this green hydrogen production technology. Herein, we report the creation of a metallic Ir nanowire network (IrNWN), which exhibits superior OER performance through its in-situ transition into an oxide structure with high intrinsic activity. At a low loading of 0.25 mgIr/cm2 in PEMWEs, IrNWN achieved a current density of 3.13 A/cm2 at a cell voltage of 1.8 V, outperforming the commercial Ir-based catalyst and surpassing the Department of Energy (DOE) 2026 technical target. Moreover, the high activity of IrNWN was maintained for 900 hours in a durability test at 2 A/cm2, showing a low degradation rate of 0.042 mV/hour. Structural analysis of the electrochemically oxidized IrNWN revealed the presence of mixed Ir oxidation states and a high density of surface terminal oxygen groups (μ1-O), which contributed to a reduced energy barrier for the rate-determining O-O coupling step.

oxygen evolution reaction↗

Experimental workflow to estimate model parameters for evaluating long term viscoelastic response of CO2 storage caprocks

Understanding the time-dependent behavior of reservoir and sealing formations is critical to assessing risks associated with geological carbon storage since time-dependent deformation strongly influences mechanical responses of some rock types. Many studies have evaluated the risk of CO2 leakage and induced seismicity by assuming poroelastic rheology in sealing formations. Few have considered viscoelastic or other time-dependent responses, where the existing literature adopts 1D models to represent long-term time-dependent responses. This is primarily because to date, the general form of a reasonable 3D time-dependent model for rocks remains unclear. In this paper, we address this unclear issue by proposing a new workflow to select constitutive modeling parameters to evaluate if a 3D viscoelastic model is reasonable using several-hour-long experimental data and a power-law response to extrapolate to the decades-long time frames of interest in geologic carbon storage. To provide experimental data, we conducted multi-level loading/unloading triaxial relaxation tests with four rock types. The experimental results showed that the maximum load relaxation observed is approximately 49%, with some rock types showing as little as 1.4%. Using a simple linear viscoelastic model, parameters were chosen such that a maximum deviation of 1.5 MPa in axial stress and 7 MPa in radial stress was attained with the extrapolated 30-year data. We found that a reasonable parameter range for the normalized elastic modulus is 0.1~2 for rocks with significant time-dependent responses and 0.01~0.06 for those with small time-dependent responses. No matter how significant time-dependent responses are for rocks considered, our results showed that the relaxation time has a general range of 1~10^10 s, whose time scale can be one or two orders higher than a time frame typically envisioned for CO2 injection projects.

Stress relaxation, 3D time-dependent model, viscoe↗

CEM MARS 6 Microwave Incident

A fire occurred in a CEM MARS 6 analytical microwave during microwave-assisted, acid digestion of a soil sample in a Research and Development (R&D) laboratory. The soil sample had been pretreated at 550°C for approximately 4 hours in a furnace prior to digesting in the microwave. Less than 1-gram aliquots of the pretreated soil sample were placed into separate microwave reaction vessels along with an acid mixture used for digestion. The microwave was used to facilitate digestion of the samples. Microwave reaction vessels were loaded with acid and soil samples, sealed in cassettes, and the cassettes placed onto a microwave carousel. A temperature probe that senses the reaction temperature during the run was inserted into the Reference Cell thermowell. The contents of the Reference Cell were identical to the contents of the other reaction cells. The researcher initiated the run and then left the laboratory to perform other work. Upon returning to check the digestion run, flames and smoke were observed originating from the microwave. The researcher exited the lab, immediate emergency actions were taken, and the local fire department responded and extinguished the fire. No personnel were injured, and no facility structural damage occurred. The affected microwave is a total loss. The fire investigation revealed the most credible cause of the fire is an incompatible temperature probe that did not accurately measure temperature of the liquid phase of the Reference sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen-Battery Hybrid Energy System on Repurposed Offshore Platforms for Efficient Clean-Energy Transition

Due to the rising global energy demand and enhanced awareness of the environmental impact of fossil fuels, the Gulf of Mexico, traditionally known for oil extraction, offers a distinct chance to repurpose the existing offshore infrastructure. With the depletion of oil reserves, it is feasible to adapt previously utilized floating platforms for extraction to generate renewable energy, specifically through wind-generated power and hydrogen production. This adaptation seeks to promote a transport system that is more ecologically friendly in the future. Offshore wind turbines serve as the main energy source, with help from battery storage and hydrogen production to enhance the overall system performance, hydrogen creation, fuel, and electricity delivery for sustainable energy production. The system is divided into two distinct cases, each evaluated for cost, performance, and feasibility, with a focus on minimizing both the Levelized Cost of Energy (LCOE) and the Levelized Cost of Hydrogen (LCOH). The first case examines the integration of offshore wind turbines with hydrogen production. Excess electricity generated by wind turbines is directed toward hydrogen production via electrolysis. The hydrogen produced can be used as fuel for vehicles or transported to the shore via pipelines. The second case investigates a technology that combines wind turbines with battery storage. The batteries possess an ability to supply electricity for a continuous duration of 4 hours maximum each day. The main objective is to reduce the LCOE by considering the battery's charging and discharging cycles, together with the uncertain attributes of wind power and battery deterioration. The produced energy can be distributed for onshore applications or utilized for the purpose of offsetting offshore loads such as subsea oil and gas production, transportation, etc. The offshore hydrogen-battery hybrid system is improved via three advanced algorithms, Particle Swarm Optimization (PSO), and Grey Wolf Optimizer (GWO). In Case 1, PSO improves hydrogen production by efficiently managing the electrolyzer’s power consumption, decreasing production costs significantly. Particle Swarm Optimization (PSO) is applied to improve the efficiency of the electrolyzer, reducing production costs and achieving an optimized CAPEX of $240.00 million (from an initial $300.00 million) and OPEX of $9.60 million per year. This system produces 4,720,000 kg of hydrogen annually, with a Levelized Cost of Hydrogen (LCOH) of $6.40/kg and an annual profit of $9.27 million. In Case 2, GWO effectively reduces the overall energy cost by improving the charge-discharge management of batteries, which extends battery life and optimizes their use. The second case focuses on integrating battery storage, optimized using the Grey Wolf Optimizer (GWO), which enhances battery charge-discharge cycles, extending battery life and lowering costs. This system achieves an optimized CAPEX of $204.80 million (from an initial $256.00 million) and OPEX of $9.29 million per year, producing 310883.39 MWh of electricity annually at a Levelized Cost of Energy (LCOE) of $86.13/MWh, with an annual profit of $6.25 million. The implementation of a comprehensive strategy results in a substantial reduction in costs, improved energy efficiency, and a dependable supply of both electric power and hydrogen, emphasizing the benefits of converting offshore oil platforms for clean energy transition. This study explores a clean strategy to enable cost-effective repurposing of offshore O&G platforms. Both cases highlight the economic and technical feasibility of transitioning offshore oil platforms to clean energy systems, demonstrating substantial cost reductions and reliable energy and hydrogen supplies for sustainable energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Decomposing Loosely Coupled Mixed-Integer Programs for Optimal Microgrid Design

Microgrids are frequently employed in remote regions, in part because access to a larger electric grid is impossible, difficult, or compromises reliability and independence. Although small microgrids often employ spot generation, in which a diesel generator is attached directly to a load, microgrids that combine these individual loads and augment generators with photovoltaic cells and batteries as a distributed energy system are emerging as a safer, less costly alternative. In this work, we present a model that seeks the minimum-cost microgrid design and ideal dispatched power to support a small remote site for one year with hourly fidelity under a detailed battery model; this mixed-integer nonlinear program (MINLP) is intractable with commercial solvers but loosely coupled with respect to time. A mixed-integer linear program (MIP) approximates the model, and a partitioning scheme linearizes the bilinear terms. We introduce a novel policy for loosely coupled MIPs in which the system reverts to equivalent conditions at regular time intervals; this separates the problem into subproblems that we solve in parallel. We obtain solutions within 5% of optimality in at most six minutes across 14 MIP instances from the literature and solutions within 5% of optimality to the MINLP instances within 20 minutes.

97 MATHEMATICS AND COMPUTING↗

Status and Trends in the U.S. Voluntary Green Power Market (2021 Data)

Voluntary green power, for the purposes of this report, refers to renewable energy procurement by retail electricity customers above state renewable energy mandates. In this report, we present data and key trends for voluntary green power markets, except for a small portion of voluntary purchasing where no data are available. In 2021, about 8 million retail electricity customers procured about 244 million megawatt-hours (MWh) of voluntary green power (Figure ES-1), representing about 27% of all U.S. renewable energy sales, about 39% of non-hydro renewable energy sales, and about 6% of all U.S. retail electricity sales. Most of the remainder of U.S. renewable energy sales reflects renewable energy procured by load-serving entities to comply with state renewable energy mandates, also known as compliance-based procurement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Meter-Based Assessment of the Time and Locational Benefits of a Large Utility’s DSM Portfolio

As decarbonization goals drive increasing levels of renewable generation, there is a need to understand the time- and location-based savings benefits of demand-side management (DSM) programs. The challenges of the 'duck curve' are driving the utility industry to consider how programs can be optimized to match demand profiles with low carbon generation resources. From an infrastructure standpoint, time- and location-targeted DSM could serve as a ‘non-wires alternative’ (NWA) to defer equipment upgrades. Additional DSM value streams are motivating innovation in savings evaluation, providing more resolved insights beyond the total annual program impact. Methods grounded in the principles of billing analysis, leveraging hourly metering at the distribution grid, can provide new visibility into the spatial and temporal savings achieved through DSM. A large body of work has investigated related topics including interval meter-based savings analysis, the time- varying nature of efficiency measures, and NWA. A less studied topic concerns the impact of DSM on the grid, based on metered consumption. This paper presents an analysis of interval data across more than 25,000 customers and twelve substations, from the Sacramento Municipal Utility District. The results show for different locations on the grid: achieved savings and the impact on grid consumption; hourly savings shapes for DSM program participants and non-participants, and how those shapes vary with season; and the impact of the programs on peak demand. These findings show the current impact of DSM, with implications for future, more intentional targeting as the utility continues to pursue aggressive electrification, efficiency, load flexibility, and reliable NWA.

Granderson, Jessica↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Anomaly Detection in SCADA-Assisted OT Networks Using Ensemble-Based State Prediction Model

The cybersecurity threats of power system gradually grow due to the increased sophisticated interactions between Information Technology (IT) and Operational Technology (OT) networks. False data injection attack (FDIA) that aims to compromise the Supervisory Control and Data Acquisition (SCADA) measurement and disturb the system operation is one of such cyber threats. Such attacks can potentially lead to significant operational issues at the control centers and substations, and hence, result in severe physical consequences. To avoid catastrophic failure across the power grid resulting from these attacks, it is essential to arm the OT network with real-time vulnerability assessment tools. To this end, this paper outlines various drawbacks of the Purdue architecture model to defend against cyberattacks in the OT network. Furthermore, a novel ensemble-based state prediction model is proposed to detect cybersecurity anomalies in SCADA assisted OT networks. The proposed model uses control center level generation and load forecasts, scheduled, and forced outages, power flow solutions, and the substation level historical data. The hypothesis of the proposed scheme relies on the fact that additional control center and substation data can hardly be accessed and compromised by attackers. One of the vital features of the proposed scheme is an hour-ahead prediction of the operational feasibility of the SCADA measurement range at the control center and substation in real time helps in detecting anomalies in measurements across both substation and the control center.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Floating Solar at Lima's Twin Lakes Reservoir

The City of Lima, Ohio is developing a floating photovoltaic (FPV) facility on the surface of Twin Lake Reservoir, adjacent to the City’s water treatment plant. The FPV array is designed with a capacity of 2 megawatts (MW) and will consist of approximately 3,500 solar panels spanning more than four acres of water surface. Based on regional solar conditions, the system will generate 2,000 megawatt-hours (MWh) of electricity annually. While the FPV system will interconnect to the electrical infrastructure serving the water treatment plant, power produced by the system will be net-metered through the utility grid, with energy credits applied to offset the plant’s overall electrical demand rather than directly supplying all plant loads in real time.

14 SOLAR ENERGY↗

Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

The Viscoplastic Behavior of Natural Hydrate‐Bearing Sandy‐Silts Under Uniaxial Strain Compression ( K 0 Loading)

Abstract The in‐situ stress state and geomechanical properties of hydrate‐bearing sediments impact hydrate formation and gas production strategies. We explore the uniaxial strain compression and stress evolution of natural hydrate‐bearing sandy‐silts from Green Canyon Block 955 in the deep‐water Gulf of Mexico. We performed constant rate of strain uniaxial strain experiments, interrupted by periods where we held the axial stress constant, to explore the vertical deformation and the evolution of the ratio of lateral to axial effective stress ( K 0 ) with time. The hydrate‐bearing sandy‐silt is stiffer and has a larger K 0 than the equivalent hydrate‐free sediment upon loading. During stress holds, the void ratio decreases sigmoidally with the log of time, and K 0 converges to isotropic conditions. We interpret that during loading, the hydrate bears the load and deforms. With time, the hydrate redistributes the load and K 0 increases. We used a viscoelastic model to describe the behavior. The model accurately captures deformation and K 0 trends but does not reproduce all the complex interactions of the hydrate with the porous skeleton. We anticipate that viscous effects within hydrate sediments will impact reservoir compression and stresses during production (hours to days), result in isotropic stress state over geological timescales, and explain the creeping movement in submarine landslides.

58 GEOSCIENCES↗

Microstructure Experiments-Enabled MARMOT Simulations of SiC/SiC-based Accident Tolerant Nuclear Fuel System

We have undertaken an experimental-computational project that addresses a few key technology gaps associated with the use of SiC/SiC composites for light water reactor fuel cladding. Two principal endeavors in this project are to assess the irradiation-induced microstructural changes and swelling in SiC/SiC composites, and to characterize and model the porous oxide surface layer (when exposed to steam) along SiC recession that is detrimental to the clad integrity under accident conditions. The project tasks are: (i) ion irradiation and characterization (University of Tennessee, Knoxville), (ii) mechanical tests and analysis (University of South Carolina), (iii) steam exposure tests (Oak Ridge National Laboratory), (iv) electron microscopy and spectroscopic characterization (NC State University), (v) x-ray microscopy and reconstruction (University of South Carolina and NC State University), (vi) phase field modeling and simulations (NC State University and Idaho National Laboratory). The effects of 10 MeV Au ion irradiation at 350°C on the microstructure evolution in SiC/SiC composites are investigated at doses up to 400 displacements per atom (dpa) at the University of Tennessee, Knoxville. Atomic force microscopy and optical profilometry reveal irradiation induced axial and radial shrinkage of the fibers for doses greater than 10 dpa. Based on detailed electron microscopy characterization, the primary cause of the fiber shrinkage is attributed to irradiation-induced loss of carbon packets. Additionally, the multilayer PyC interface is observed to portray high resistance to irradiation damage. The mechanical response and failure mechanisms of un-irradiated samples is also assessed through loading tests and X-ray imaging at the University of South Carolina. Steam exposure tests are performed at the Oak Ridge National Laboratory in a facility that represents a reactor pressure vessel under a loss-of-coolant-accident scenario. The samples that are analyzed methodically in this report are tested for 32/31 hours at 1200°C with a velocity of 0.25 cm/s for the pressures: 0.1 MPa, 0.45 MPa, 0.92 MPa and 1.38 MPa. Scanning/transmission electron microscopy analysis conducted at the NC State University (NCSU) shows that the oxide layer thickness increases with the steam pressure. While the oxide layer is crystalline (α- cristobalite) for the pressures 0.45 MPa, 0.92 MPa and 1.38 MPa, the layer is amorphous at 0.1 MPa. Results from Raman spectroscopy have also confirmed the formation of α-cristobalite phase of SiO₂. The abrupt increase in the integrated Raman intensity ratio between steam pressures 0.1 and 0.45 MPa suggests the onset of accelerated crystallization. Non-destructive three dimensional X-ray microscopy/tomography (XCT) and computational image processing techniques are employed by the University of South Carolina to probe the porous oxidation features on SiC samples at varying pressures. Interestingly, most pores are observed to be located away from the surface as well as the oxide-SiC interface. The average oxide layer thickness assessed from the XCT analysis is seen to be in excellent agreement with the values determined through scanning electron microscopy analysis for the highest pressures where the oxide layer is relatively more uniform. A phase-field model developed by the NC State University and Idaho National Laboratory for simulating oxidation of SiC by steam captures the paralinear kinetics of SiC oxidation with a high degree of fidelity. Results from quasi-one-dimensional and two dimensional simulations show that the pores with oxidizing species lead to a higher volatilization rate. These simulations indicate that the enhanced apparent volatilization rates at higher pressures observed in experiments can be rationalized by the increased volatilization from the pores. The project team has also successfully developed the capability to import images from experiments for realistic evolution of the oxidizing microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗