Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Voltage Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Evaluation of Case Size 0603 BME Ceramic Capacitors

High volumetric efficiency of commercial base metal electrode (BME) ceramic capacitors allows for a substantial reduction of weight and sizes of the parts compared to currently used military grade precious metal electrode (PME) capacitors. Insertion of BME capacitors in space applications requires a thorough analysis of their performance and reliability. In this work, six types of cases size 0603 BME capacitors from three vendors have been evaluated. Three types of multilayer ceramic capacitors (MLCCs) were designed for automotive industry and three types for general purposes. Leakage currents in the capacitors have been measured in a wide range of voltages and temperatures, and measurements of breakdown voltages (VBR) have been used to assess the proportion and severity of defects in the parts. The effect of soldering-related thermal shock stresses was evaluated by analysis of distributions of VBR for parts in 'as is' condition and after terminal solder dip testing at 350 C. Highly Accelerated Life Testing (HALT) at different temperatures was used to assess the activation energy of degradation of leakage currents and predict behavior of the parts at life test and normal operating conditions. To address issues related to rework and manual soldering, capacitors were soldered onto different substrates at different soldering conditions. The results show that contrary to a common assumption that large-size capacitors are mostly vulnerable to soldering stresses, cracking in small size capacitors does happen unless special measures are taken during assembly processes.

testing↗

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗

Selecting Critical Scenarios of DER Adoption in Distribution Grids Using Bayesian Optimization

We develop a new methodology to select scenarios of DER adoption most critical for distribution grids. Anticipating risks of future voltage and line flow violations due to additional PV adopters is central for utility investment planning but continues to rely on deterministic or ad hoc scenario selection. We propose a highly efficient search framework based on multi-objective Bayesian Optimization. We treat underlying grid stress metrics as computationally expensive black-box functions, approximated via Gaussian Process surrogates and design an acquisition function based on probability of scenarios being Pareto-critical across a collection of line- and bus-based violation objectives. Our approach provides a statistical guarantee and offers an order of magnitude speed-up relative to a conservative exhaustive search. Case studies on realistic feeders with 200-400 buses demonstrate the effectiveness and accuracy of our approach.

Mulkin, Olivier↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗

Investigating the Performance of SF6 Replacement Gases to Enable the Next Generation of Pulsed Power

High voltage switches are essential components in pulsed power systems, where consistent and reliable performance is crucial—particularly as the field explores alternatives to SF 6 as an insulating gas. This project examines the self-break voltage distributions of various gases, with a focus on the low-voltage discharges observed in the lower tail of these distributions. Experimental results revealed that the specific housing design influenced the self-break behavior. Among the tested gases, air demonstrated a more favorable overall distribution compared to SF 6 , albeit requiring higher operating pressures. However, air also exhibited a greater likelihood of extremely low-voltage dropouts, raising concerns about its suitability as a direct replacement for SF 6 . Notably, all gases tested showed a higher-than-expected probability of low-voltage events when considering the tail of the distribution rather than the bulk behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Puncture discharges in surface dielectrics as contaminant sources in spacecraft environments

Spacecraft in geosynchronous orbits are known to become charged to large negative potentials during the local midnight region of the satellite orbit. Such discharges have been studied by the electron beam irradiation of dielectric samples in a vacuum environment. In addition to static measurements and photographic examination of the puncture discharges in Teflon samples, the transient characteristics of the electrical discharges are determined from oscillographs of voltage and current and by charged particle measurements employing a biased Faraday cup and a retarding potential analyzer. Using these latter techniques, studies of angular and energy distributions of charged particles have indicated an initial burst of high energy electrons (5 x 10 to the 13th power per discharge at energies greater than 300 eV) followed by a less intense burst of lower energy negative particles. Positive ions are emitted from the discharge site in an initial high velocity burst followed by a lower velocity burst tentatively identified as carbon.

Yadlowsky, E. J.↗

Manganese-rich high entropy oxides for lithium-ion batteries:materials design approaches to address voltage fade

Lithium- and manganese-rich oxides are of interest as lithium-ion battery cathode materials as Mn is earth abundant, low cost, and can deliver high capacity. Herein, a high entropy strategy was used to prepare Mn rich high entropy oxide (HEO) materials by including four additional metals (Ni, Co, Fe and Al) in the compositions using a mild co-precipitation method. Two HEOs (Li x Ni 0.1 Mn 0.6 Co 0.1 Al 0.1 Fe 0.1 O y , where x = 1.5 for HEO-L and x = 0.5 for HEO-H) with layered and spinel-layered hybrid structures were investigated where the morphology, elemental composition, structure, atomic level phase distribution, and electrochemistry were determined. The HEO-L samples involve a Li 2 TMO 3 layered structure with ~39% stacking faults. HEO-H is a hybrid structure comprised of 80 wt% spinel and 20 wt% LiMO 2 layered structure. The high entropy manganese-rich HEO-L showed higher capacity and 93% retention of the average voltage after 100 cycles while HEO-H showed higher capacity retention and near 100% average voltage retention. Finally, operando X-ray absorption spectroscopy revealed that the Ni, Co, and Mn are redox active in both materials while the Fe center remains at the Fe 3+ oxidation state throughout cycling, where the changes in the oxidation states for both materials during discharge were consistent with the delivered electrochemical capacity rationalizing the observed electrochemistry.

25 ENERGY STORAGE↗

Black-Starting Microgrids Using Inverter-Based Distributed Energy Resources

Recent trends in power systems show increasing deployment of inverter-based distributed energy resources (DERs) at the distribution level. Efforts have also been made to use inverter-based DERs for system restoration of critical sections of distribution feeders. In the past few years, there has been active consideration of using local grid-forming (GFM) DERs, which can form their own voltage and frequency, to black-start microgrids instead of waiting for the bulk system for supply restoration. However, using current-limited inverter-based DERs for black-start operations with high inrush currents can pose some technical challenges. This paper presents detailed electromagnetic transient studies on a digital real-time simulator to assess the operational feasibility of using local inverter-based GFM DERs for microgrid black-start operations as a bottom-up approach instead of a top-down approach where the substation is used to restore critical sections of the feeder. The paper presents key modeling details for distribution system components for studying GFM DER-based microgrid black-start operations. The paper presents simulation results comparing different black-start approaches using GFM DERs for two test systems: i) a simple test microgrid and ii) a real-world utility microgrid currently being designed and deployed by Holy Cross Energy in Colorado.

black start↗

Biomimetic composite architecture achieves ultrahigh rate capability and cycling life of sodium ion battery cathodes

Sodium ion batteries are an emerging candidate to replace lithium ion batteries in large-scale electrical energy storage systems due to the abundance and widespread distribution of sodium. Despite the growing interest, the development of high-performance sodium cathode materials remains a challenge. In particular, polyanionic compounds are considered as a strong cathode candidate owing to their better cycling stability, a flatter voltage profile, and stronger thermal stability compared to other cathode materials. Here, we report the rational design of a biomimetic bone-inspired polyanionic Na3V2(PO4)3-reduced graphene oxide composite (BI-NVP) cathode that achieves ultrahigh rate charging and ultralong cycling life in a sodium ion battery. At a charging rate of 1 C, BI-NVP delivers 97% of its theoretical capacity and is able to retain a voltage plateau even at the ultra-high rate of 200 C. It also shows long cycling life with capacity retention of 91% after 10 000 cycles at 50 C. The sodium ion battery cells with a BI-NVP cathode and Na metal anode were able to deliver a maximum specific energy of 350 W h kg−1 and maximum specific power of 154 kW kg−1. In situ and postmortem analyses of cycled BI-NVP (including by Raman and XRD spectra) HRTEM, and STEM-EELS, indicate highly reversible dilation–contraction, negligible electrode pulverization, and a stable NVP-reduced graphene oxide layer interface. The results presented here provide a rational and biomimetic material design for the electrode architecture for ultrahigh power and ultralong cyclability of the sodium ion battery full cells when paired with a sodium metal anode.

25 ENERGY STORAGE↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗

Accelerated life testing and reliability of high K multilayer ceramic capacitors

The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

Minford, W. J.↗

Active Piezoelectric Diaphragms

Several active piezoelectric diaphragms were fabricated by placing unelectroded piezoelectric disks between copper clad films patterned with Inter-Circulating Electrodes "ICE". When a voltage potential is applied to the electrodes, the result is radially distributed electric field that mechanically strains the piezo-ceramic along the Z-axis (perpendicular to the applied electric field), rather than the expected in-plane (XY-axis) direction. Unlike other out of plane piezoelectric actuators, which are benders, these Radial Field Diaphragms (RFDs) strain concentrically yet afford high displacements while maintaining a constant circumference. This paper covers the fabrication and characterization of these diaphragms as a function of poling field strength, ceramic diameter and line spacing, as well as the surface topography, the resulting strain field and displacement as a function of applied voltage ranging from DC to 10 Hz.

Bryant, Robert G.↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗