Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HISTOGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

An Electron Backscatter Diffraction Analysis of Grain Boundary Initiated Discontinuous Precipitation in U-10Mo

The effect of varied thermomechanical processing on discontinuous precipitation (DP) in U-10Mo was investigated, with specific emphasis on understanding the role of grain boundary misorientation in DP. Varied prior homogenization heat treatment and thermomechanical processing resulted in differences in both the fraction of DP and the colony width, and was attributed to variations in the grain boundary misorientation distribution. Regardless of the degree of DP-based transformation, extensive growth of DP colonies was dominant on 30°–45° misorientation boundaries. Interestingly, misorientation histograms of the deformed and annealed specimens suggest the processing steps involved may have inhibited DP colony growth along a small fraction of these high angle boundaries. Large-area electron backscatter diffraction montages coupled with high resolution mapping suggest symmetric {110}-type interfaces may be important considerations for mitigating extensive DP growth in this alloy system.

Discontinuous Precipitation, Uranium, Electron Bac↗

Uranium Oxide Synthetic Pathway Discernment through Unsupervised Morphological Analysis

We present a novel unsupervised machine learning method for quantitative representation of scanning electron micrographs and its applications and performance for nuclear forensic analysis of uranium ore concentrates. The method uses a vector quantizing variational autoencoder followed by a histogram operation to encode a micrograph into a single dimensional representation, called the latent vector. The method requires no extant labeling of the data and can be applied over large datasets of micrographs with minimal human interaction. The representations generated are broadly descriptive of each micrograph and the microstructure of the material imaged. In the case of uranium ore concentrate analysis, the representations were amenable to processing reagent and ore concentrate species classification with accuracy of 81:8%, which is competitive with state-of-the-art supervised networks. The representations were also used to classify previously unseen processing routes, were able to classify imaging parameters such as magnification (to 76:0% accuracy), were able to classify fine grained process parameters such as calcining temperature (to 74:4% accuracy), and their informatic properties indicate that they are generally descriptive of the image represented. This method can be applied across microstructure analysis fields to perform quantitative analysis without the need for labor intensive and possibly biased human analysis.

Scanning Electron Microscopy, Vector Quantizing Va↗

Prediction of electric and magnetic fields from spectral data using machine learning algorithms for Doppler-free saturation spectroscopy diagnostics

The prediction of electric and magnetic field amplitudes from atomic spectral data is critical for plasma control in fusion devices such as tokamaks. Conventional approaches that rely on physics-based models are computationally expensive and unsuitable for real-time applications. In this work, we develop and benchmark three machine learning algorithms—simulation-based inference (SBI), fully connected neural networks (FCNN), and histogram-based gradient boosting regression (GBR-Hist)—to infer field intensities directly from Doppler-free saturation spectroscopy (DFSS) spectra. Synthetic datasets of spectra were generated using the EZSSS code and evaluated both with and without added Poisson noise to mimic experimental conditions. We find that SBI achieves the highest accuracy and robustness, FCNN provides a strong balance of accuracy and computational efficiency for real-time applications, and GBR-Hist offers the fastest inference but is more sensitive to noise. Furthermore, these results demonstrate the potential of machine learning to accelerate DFSS analysis and enhance its utility for plasma diagnostics and control.

Doppler-free saturation spectroscopy↗

Abnormal grain growth in AISI 304L stainless steel

The microstructural evolution during abnormal grain growth (secondary recrystallization) in 304L stainless steel was studied in a wide range of annealing temperatures and times. At relatively low temperatures, the grain growth mode was identified as normal. However, at homologous temperatures between 0.65 (850 °C) and 0.7 (900 °C), the observed transition in grain growth mode from normal to abnormal, which was also evident from the bimodality in grain size distribution histograms, was detected to be caused by the dissolution/coarsening of carbides. The microstructural features such as dispersed carbides were characterized by optical metallography, X-ray diffraction, scanning electron microscopy, energy dispersive X-ray analysis, and microhardness. Continued annealing to a long time led to the completion of secondary recrystallization and the subsequent reappearance of normal growth mode. Another instance of abnormal grain growth was observed at homologous temperatures higher than 0.8, which may be attributed to the grain boundary faceting/defaceting phenomenon. It was also found that when the size of abnormal grains reached a critical value, their size will not change too much and the grain growth behavior becomes practically stagnant. - Highlights: • Abnormal grain growth (secondary recrystallization) in AISI 304L stainless steel • Exaggerated grain growth due to dissolution/coarsening of carbides • The enrichment of carbide particles by titanium • Abnormal grain growth due to grain boundary faceting at very high temperatures • The stagnancy of abnormal grain growth by annealing beyond a critical time.

36 MATERIALS SCIENCE↗

Microstructural evolution and grain growth kinetics of GZ31 magnesium alloy

Grain growth behavior of Mg–3Gd–1Zn (GZ31) magnesium alloy was studied in a wide range of annealing time and temperature to clarify the kinetics of grain growth, microstructural evolution and related metallurgical phenomena. This material exhibited typical normal grain growth mode under annealing conditions with annealing temperature of lower than 300 °C and soaking time of lower than 240 min. However, the abnormality in grain growth was also evident at annealing temperature of 400 °C and 500 °C. The dependence of abnormal grain growth (AGG) at mentioned annealing temperatures upon microstructural features such as dispersed precipitates, which were rich in Zn and Gd, was investigated by optical micrographs, X-ray diffraction patterns, scanning electron microscopy images, and energy dispersive X-ray analysis spectra. The bimodality in grain-size distribution histograms also signified the occurrence of AGG. Based on the experimental data on grain growth obtained by annealing treatments, the grain growth exponent and the activation energy were also figured out.

36 MATERIALS SCIENCE↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Applicator-guided volumetric-modulated arc therapy for low-risk endometrial cancer

The aim of this study was to report the feasibility of volumetric-modulated arc therapy (VMAT) in the postoperative irradiation of the vaginal vault. Moreover, the VMAT technique was compared with 3D conformal radiotherapy (3D-CRT) and fixed-field intensity-modulated radiotherapy (IMRT), in terms of target coverage and organs at risk sparing. The number of monitor units and the delivery time were analyzed to score the treatment efficiency. All plans were verified in a dedicated solid water phantom using a 2D array of ionization chambers. Twelve patients with endometrial carcinoma who underwent radical hystero-adenexectomy and fixed-field IMRT treatments were retrospectively included in this analysis; for each patient, plans were compared in terms of dose-volume histograms, homogeneity index, and conformity indexes. All techniques met the prescription goal for planning target volume coverage, with VMAT showing the highest level of conformity at all dose levels. VMAT resulted in significant reduction of rectal and bladder volumes irradiated at all dose levels compared with 3D-CRT. No significant differences were found with respect to IMRT. Moreover, a significant improvement of the dose conformity was reached by VMAT technique not only at the 95% dose level (0.74 vs. 0.67 and 0.62) but also at 50% and 75% levels of dose prescription. In addition, VMAT plans showed a significant reduction of monitor units by nearly 28% with respect to IMRT, and reduced treatment time from 11 to <3 minutes for a single 6-Gy fraction. In conclusion, VMAT plans can be planned and carried out with high quality and efficiency for the irradiation of vaginal vault alone, providing similar or better sparing of organs at risk to fixed-field IMRT and resulting in the most efficient treatment option. VMAT is currently our standard approach for radiotherapy of low-risk endometrial cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-modulated arc therapy (RapidArc) vs. conventional fixed-field intensity-modulated radiotherapy for {sup 18}F-FDG-PET-guided dose escalation in oropharyngeal cancer: A planning study

Fluorine-18-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG-PET)–guided focal dose escalation in oropharyngeal cancer may potentially improve local control. We evaluated the feasibility of this approach using volumetric-modulated arc therapy (RapidArc) and compared these plans with fixed-field intensity-modulated radiotherapy (IMRT) focal dose escalation plans. Materials and methods: An initial study of 20 patients compared RapidArc with fixed-field IMRT using standard dose prescriptions. From this cohort, 10 were included in a dose escalation planning study. Dose escalation was applied to {sup 18}F-FDG-PET–positive regions in the primary tumor at dose levels of 5% (DL1), 10% (DL2), and 15% (DL3) above standard radical dose (65 Gy in 30 fractions). Fixed-field IMRT and double-arc RapidArc plans were generated for each dataset. Dose-volume histograms were used for plan evaluation and comparison. The Paddick conformity index (CI{sub Paddick}) and monitor units (MU) for each plan were recorded and compared. Both IMRT and RapidArc produced clinically acceptable plans and achieved planning objectives for target volumes. Dose conformity was significantly better in the RapidArc plans, with lower CI{sub Paddick} scores in both primary (PTV1) and elective (PTV2) planning target volumes (largest difference in PTV1 at DL3; 0.81 ± 0.03 [RapidArc] vs. 0.77 ± 0.07 [IMRT], p = 0.04). Maximum dose constraints for spinal cord and brainstem were not exceeded in both RapidArc and IMRT plans, but mean doses were higher with RapidArc (by 2.7 ± 1 Gy for spinal cord and 1.9 ± 1 Gy for brainstem). Contralateral parotid mean dose was lower with RapidArc, which was statistically significant at DL1 (29.0 vs. 29.9 Gy, p = 0.01) and DL2 (29.3 vs. 30.3 Gy, p = 0.03). MU were reduced by 39.8–49.2% with RapidArc (largest difference at DL3, 641 ± 94 vs. 1261 ± 118, p < 0.01). {sup 18}F-FDG-PET–guided focal dose escalation in oropharyngeal cancer is feasible with RapidArc. Compared with conventional fixed-field IMRT, RapidArc can achieve better dose conformity, improve contralateral parotid sparing, and uses fewer MU.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry estimation on variations of patient size in prostate volumetric-modulated arc therapy

This study investigated the dosimetric variations of the target and critical organs of patients who had weight loss associated with prostate volumetric-modulated arc therapy (VMAT). Five patients with prostate volumes ranging from 32–86.5 cm{sup 3} were selected from a group of 30 patients. Prostate VMAT plans were carried out on each patient using the 6-MV photon beam with a single 360° arc. Decrease of patient size as a result of weight loss was mimicked by contracting the patient's external contour in the anterior, left, and right directions with depths from 0.5–2 cm. Soft tissue excluded by the contracted external contour was replaced by air and the dose distribution was recalculated using the same beam geometry and dose prescription. Dose-volume histograms and dose-volume points such as D99% and D5% for the planning target volume (PTV), clinical target volume (CTV), rectum, bladder, and femoral heads were calculated with variations of reduced depth. In addition, the minimum, maximum, and mean doses for the target and critical organs were determined. PTV and CTV D99% were found to have increased 2.86 ± 0.30% per cm and 2.75 ± 0.38% per cm of reduced depth ranging from 0.5–2 cm. Moreover, the rectal and bladder D30% increased 2.20 ± 0.20% per cm and 2.31 ± 0.83% per cm, and the femoral head D5% increased 3.30 ± 0.11% per cm of reduced depth. Results from variations of the minimum, maximum, and mean doses of the PTV, CTV, rectum, bladder, and femoral heads showed that there was a >5% increase of dose when the reduced depth reached 2 cm. This study provided dosimetry estimation for radiation oncology staff to justify dose variations of the target and critical organs when patients' weight loss occurred in prostate VMAT. Dose variations >5% were seen when the patients' reduced depth was equal to 2 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Maximizing dosimetric benefits of IMRT in the treatment of localized prostate cancer through multicriteria optimization planning

We examine the quality of plans created using multicriteria optimization (MCO) treatment planning in intensity-modulated radiation therapy (IMRT) in treatment of localized prostate cancer. Nine random cases of patients receiving IMRT to the prostate were selected. Each case was associated with a clinically approved plan created using Corvus. The cases were replanned using MCO-based planning in RayStation. Dose-volume histogram data from both planning systems were presented to 2 radiation oncologists in a blinded evaluation, and were compared at a number of dose-volume points. Both physicians rated all 9 MCO plans as superior to the clinically approved plans (p<10{sup −5}). Target coverage was equivalent (p = 0.81). Maximum doses to the prostate and bladder and the V50 and V70 to the anterior rectum were reduced in all MCO plans (p<0.05). Treatment planning time with MCO took approximately 60 minutes per case. MCO-based planning for prostate IMRT is efficient and produces high-quality plans with good target homogeneity and sparing of the anterior rectum, bladder, and femoral heads, without sacrificing target coverage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy

To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV) (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of the IMNs. Refinement of radiation techniques in reconstructed patients who require comprehensive nodal irradiation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

A study on planning organ at risk volume for the rectum using cone beam computed tomography in the treatment of prostate cancer

In this study, we analyzed planning organ at risk volume (PRV) for the rectum using a series of cone beam computed tomographies (CBCTs) acquired during the treatment of prostate cancer and evaluated the dosimetric effect of different PRV definitions. Overall, 21 patients with prostate cancer were treated radically with 78 Gy in 39 fractions had in total 418 CBCTs, each acquired at the end of the first 5 fractions and then every alternate fraction. The PRV was generated from the Boolean sum volume of the rectum obtained from first 5 fractions (PRV-CBCT-5) and from all CBCTs (PRV-CBCT-All). The PRV margin was compared at the superior, middle, and inferior slices of the contoured rectum to compare PRV-CBCT-5 and PRV-CBCT-All. We also compared the dose received by the planned rectum (Rectum-computed tomography [CT]), PRV-CBCT-5, PRV-CBCT-All, and average rectum (CBCT-AV-dose-volume histogram [DVH]) at critical dose levels. The average measured rectal volume for all 21 patients for Rectum-CT, PRV-CBCT-5, and PRV-CBCT-All was 44.3 ± 15.0, 92.8 ± 40.40, and 121.5 ± 36.7 cm{sup 3}, respectively. For PRV-CBCT-All, the mean ± standard deviation displacement in the anterior, posterior, right, and left lateral directions in centimeters was 2.1 ± 1.1, 0.9 ± 0.5, 0.9 ± 0.8, and 1.1 ± 0.7 for the superior rectum; 0.8 ± 0.5, 1.1 ± 0.5, 1.0 ± 0.5, and 1.0 ± 0.5 for the middle rectum; and 0.3 ± 0.3; 0.9 ± 0.5; 0.4 ± 0.2, and 0.5 ± 0.3 for the inferior rectum, respectively. The first 5 CBCTs did not predict the PRV for individual patients. Our study shows that the PRV margin is different for superior, middle, and the inferior parts of the rectum, it is wider superiorly and narrower inferiorly. A uniform PRV margin does not represent the actual rectal variations during treatment for all treatment fractions. The large variation in interpatient rectal size implies a potential role for adaptive radiotherapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicriteria optimization informed VMAT planning

We developed a patient-specific volumetric-modulated arc therapy (VMAT) optimization procedure using dose-volume histogram (DVH) information from multicriteria optimization (MCO) of intensity-modulated radiotherapy (IMRT) plans. The study included 10 patients with prostate cancer undergoing standard fractionation treatment, 10 patients with prostate cancer undergoing hypofractionation treatment, and 5 patients with head/neck cancer. MCO-IMRT plans using 20 and 7 treatment fields were generated for each patient on the RayStation treatment planning system (clinical version 2.5, RaySearch Laboratories, Stockholm, Sweden). The resulting DVH of the 20-field MCO-IMRT plan for each patient was used as the reference DVH, and the extracted point values of the resulting DVH of the MCO-IMRT plan were used as objectives and constraints for VMAT optimization. Weights of objectives or constraints of VMAT optimization or both were further tuned to generate the best match with the reference DVH of the MCO-IMRT plan. The final optimal VMAT plan quality was evaluated by comparison with MCO-IMRT plans based on homogeneity index, conformity number of planning target volume, and organ at risk sparing. The influence of gantry spacing, arc number, and delivery time on VMAT plan quality for different tumor sites was also evaluated. The resulting VMAT plan quality essentially matched the 20-field MCO-IMRT plan but with a shorter delivery time and less monitor units. VMAT plan quality of head/neck cancer cases improved using dual arcs whereas prostate cases did not. VMAT plan quality was improved by fine gantry spacing of 2 for the head/neck cancer cases and the hypofractionation-treated prostate cancer cases but not for the standard fractionation–treated prostate cancer cases. MCO-informed VMAT optimization is a useful and valuable way to generate patient-specific optimal VMAT plans, though modification of the weights of objectives or constraints extracted from resulting DVH of MCO-IMRT or both is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlating planned radiation dose to the cochlea with primary site and tumor stage in patients with head and neck cancer treated with intensity-modulated radiation therapy

The aim of the study was to determine tumor characteristics that predict higher planned radiation (RT) dose to the cochlea in patients with head and neck cancer (HNC) treated with intensity-modulated radiotherapy (IMRT). From 2004 to 2012, 99 patients with HNC underwent definitive IMRT to a median dose of 69.96 Gy in 33 fractions, with the right and left cochlea-vestibular apparatus contoured for IMRT optimization as avoidance structures. If disease involvement was adjacent to the cochlea, preference was given to tumor coverage by prescription dose. Descriptive statistics were calculated for dose-volume histogram planning data, and mean planning dose to the cochlea (from left or right cochlea, receiving the greater amount of RT dose) was correlated to primary site and tumor stage. Mean (standard deviation) cochlear volume was 1.0 (0.60) cm{sup 3} with maximum and mean planned doses of 31.9 (17.5) Gy and 22.1 (13.7) Gy, respectively. Mean planned dose (Gy) to cochlea by tumor site was as follows: oral cavity (18.6, 14.4), oropharynx (21.7, 9.1), nasopharynx (36.3, 10.4), hypopharynx (14.9, 7.1), larynx (2.1, 0.62), others including the parotid gland, temporal bone, and paranasal sinus (33.6, 24.0), and unknown primary (25.6, 6.7). Average mean planned dose (Gy) to the cochlea in T0-T2 and T3-T4 disease was 22.0 and 29.2 Gy, respectively (p = 0.019). By site, a significant difference was noted for nasopharynx and others (31.6 and 50.7, p = 0.012) but not for oropharynx, oral cavity, and hypopharynx. Advanced T category predicted for higher mean cochlear dose, particularly for nasopharyngeal, parotid gland, temporal bone, and paranasal sinus HNC sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneity index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗