Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Unstructured Grid Adaptation and Solver Technology for Turbulent Flows

Unstructured grid adaptation is a tool to control Computational Fluid Dynamics (CFD) discretization error. However, adaptive grid techniques have made limited impact on production analysis workflows where the control of discretization error is critical to obtaining reliable simulation results. Issues that prevent the use of adaptive grid methods are identified by applying unstructured grid adaptation methods to a series of benchmark cases. Once identified, these challenges to existing adaptive workflows can be addressed. Unstructured grid adaptation is evaluated for test cases described on the Turbulence Modeling Resource (TMR) web site, which documents uniform grid refinement of multiple schemes. The cases are turbulent flow over a Hemisphere Cylinder and an ONERA M6Wing. Adaptive grid force and moment trajectories are shown for three integrated grid adaptation processes with Mach interpolation control and output error based metrics. The integrated grid adaptation process with a finite element (FE) discretization produced results consistent with uniform grid refinement of fixed grids. The integrated grid adaptation processes with finite volume schemes were slower to converge to the reference solution than the FE method. Metric conformity is documented on grid/metric snapshots for five grid adaptation mechanics implementations. These tools produce anisotropic boundary conforming grids requested by the adaptation process.

Park, Michael A.↗

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Dynamic Grid Impedance and Its Impacts on Harmonics and Stability of Inverter Based Resources Plant

Nowadays, a large number of inverter-based resources (IBRs) are integrated into the grid at a single connection point as an IBR plant. In this article, a virtual dynamic grid impedance concept is introduced to evaluate the harmonics and stability for grid integration of an IBR plant containing multiple IBRs. First, a detailed theoretical study is conducted to build a foundation of the virtual grid impedance concept, which is a dynamic impedance that changes with the number of IBRs added into an IBR plant. Then, based on the new virtual dynamic grid impedance concept, frequency spectrum analysis is performed to explore harmonic impact at the interconnection point for an IBR plant with IBRs having L, LC, and LCL filters, respectively. An electromagnetic transient (EMT) simulation model of a grid-connected IBR plant is developed to explore the harmonics and stability of the IBR plant connected to the grid as well as the reliable operation of IBRs within the plant from the novel virtual equivalent dynamic grid impedance point of view. Hardware experiments are conducted to validate the EMT simulation evaluation. The results show that the number of IBRs added into an IBR plant influences the grid impedance, i.e., grid strength, and the grid impedance variation has multiple impacts on the IBR plant and IBRs within the plant depending on the grid-connected filters of the IBRs.

grid impedance↗

Sustainable Data Evolution Technology (SDET) for Power Grid Optimization (Final Report)

This project develops an innovative sustainable data evolution technology (SDET) to create open-access power grid datasets and facilitate updates to these datasets by the power grid community. The lack of open-access, realistic large-scale datasets significantly limits the ability of researchers, developers and ultimately end users to develop, benchmark and compare new methods and tools for optimizing the operation and planning of the grid, which leads to slow adoption by end users. Available open datasets include the IEEE sponsored 14-300 bus transmission test cases and distribution test feeders, the Edinburgh Power Systems Test Case Archive (39-2224 buses), and the Polish cases (2383-3375 buses) available with MATPOWER. These datasets serve certain purposes, but for power grid optimization, they are insufficient in one or more of these aspects: 1) they are too small; 2) they are incomplete in both models and scenarios for optimization purposes; and 3) they are static and are not keeping up with grid needs. The SDET technology delivers large-scale realistic datasets and data-creation tools capable of generating new datasets. We work closely with the Category-2 data repository project awarded by the same GRID DATA program. The generated datasets and data creation tools are compatible with and available through the data repository. The objective is to make this a sustained effort within and beyond the ARPA-E GRID DATA program so that the datasets can evolve over time and meet the current and future needs for power grid optimization and potentially other applications in power grid operation and planning. The novel and disruptive features of SDET differentiate itself from prior work in the following aspects: 1) SDET derives features and metrics for both transmission and distribution (T&D) systems by analyzing many public and private datasets provided by our industry partners National Rural Electric Cooperative Association (NRECA) and PJM Interconnection (PJM). 2) SDET develops data-creation tools and use these tools to generate large-scale open-access realistic datasets that comply with the metrics for both T&D systems. 3) SDET validates the created datasets using industry tools provided by our vendor partner GE Energy Solution. The data creation tools, as well as the created datasets, are integrated into the data repository (DR. POWER) funded by ARPA-E GRID DATA program in Category 2. Users can use the datasets and access these data creation tools to create and update datasets, thus datasets can evolve per user requirements and power grid development. The SDET is a novel and disruptive technology compared to current ad hoc and static dataset generation. It is expected the SDET technology will fundamentally enhance the development, assessment, and adoption of new methods and tools for power grid optimization and other applications, which in turn would significantly improve the reliability, resiliency, and efficiency of the power grid – a major ARPA-E mission objective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ion beamlet steering for two-grid electrostatic thrusters

An experimental study of ion beamlet steering in which the direction of beamlets emitted from a two grid aperture system is controlled by relative translation of the grids, is described. The results can be used to design electrostatic accelerating devices for which the direction and focus of emerging beamlets are important. Deflection and divergence angle data are presented for two grid systems as a function of the relative lateral displacement of the holes in these grids. At large displacements, accelerator grid impingements become excessive and this determines the maximum allowable displacement and as a result the useful range of beamlet deflection. Beamlet deflection is shown to vary linearly with grid offset angle over this range. The divergence of the beamlets is found to be unaffected by deflection over the useful range of beamlet deflection. The grids of a typical dished grid ion thruster are examined to determine the effects of thermally induced grid distortion and prescribed offsets of grid hole centerlines on the characteristics of the emerging beamlets. The results are used to determine the region on the grid surface where ion beamlet deflections exceed the useful range. Over this region high accelerator grid impingement currents and rapid grid erosion are predicted.

Homa, J. M.↗

Composite grid and finite-volume LU implicit scheme for turbine flow analysis

A composite grid was generated in an attempt to improve grid quality for a typical turbine blade with large camber in terms of mesh control, smoothness, and orthogonality. This composite grid consists of the C grid (or O grid) in the immediate vicinity of the blade and the H grid in the upstream region and in the middle of the blade passage between the C grids. It provides a good boundary layer resolution around the leading edge region for viscous calculation, has orthogonality at the blade surface and slope continuity at the C-H (or O-H) interface, and has flexibility in controlling the mesh distribution in the upstream region without using excessive grid points. This composite grid eliminates the undesirable qualities of a single grid when generated for a typical turbine geometry. A finite-volume lower-upper (LU) implicit scheme can be used in solving for the turbine flows on the composite grid. This grid has a special grid node that is connected to more than four neighboring nodes in two dimensions and to more than six nodes in three dimensions. But the finite-volume approach poses no problem at the special point because each interior cell has only four neighboring cells in two dimensions and only six cells in three dimensions. The finite-volume LU implicit scheme was demonstrated to be robust and efficient for both external and internal flows in a broad flow regime.

Choo, Yung K.↗

Composite grid and finite-volume LU implicit scheme for turbine flow analysis

A composite grid was generated in an attempt to improve grid quality for a typical turbine blade with large camber in terms of mesh control, smoothness, and orthogonality. This composite grid consists of the C grid (or O grid) in the immediate vicinity of the blade and the H grid in the upstream region and in the middle of the blade passage between the C grids. It provides a good boundary layer resolution around the leading edge region for viscous calculation, has orthogonality at the blade surface and slope continuity at the C-H (or O-H) interface, and has flexibility in controlling the mesh distribution in the upstream region without using excessive grid points. This composite grid eliminates the undesirable qualities of a single grid when generated for a typical turbine geometry. A finite-volume lower-upper (LU) implicit schemes can be used in solving for the turbine flows on the composite grid. This grid has a special grid node that is connected to more than four neighboring nodes in two dimensions and to more than six nodes in three dimensions. But the finite-volume approach poses no problem at the special point because each interior cell has only four neighboring cells in two dimensions and only six cells in three dimensions. The finite-volume LU implicit scheme was demonstrated to be robust and efficient for both external and internal flows in a broad flow regime.

Choo, Yung K.↗

Grid generation research at OSU

In the last two years, effort was concentrated on: (1) surface modeling; (2) surface grid generation; and (3) 3-D flow space grid generation. The surface modeling shares the same objectives as the surface modeling in computer aided design (CAD), so software available in CAD can in principle be used for solid modeling. Unfortunately, however, the CAD software cannot be easily used in practice for grid generation purposes, because they are not designed to provide appropriate data base for grid generation. Therefore, we started developing a generalized surface modeling software from scratch, that provides the data base for the surface grid generation. Generating surface grid is an important step in generating a 3-D space for flow space. To generate a surface grid on a given surface representation, we developed a unique algorithm that works on any non-smooth surfaces. Once the surface grid is generated, a 3-D space can be generated. For this purpose, we also developed a new algorithm, which is a hybrid of the hyperbolic and the elliptic grid generation methods. With this hybrid method, orthogonality of the grid near the solid boundary can be easily achieved without introducing empirical fudge factors. Work to develop 2-D and 3-D grids for turbomachinery blade geometries was performed, and as an extension of this research we are planning to develop an adaptive grid procedure with an interactive grid environment.

Nakamura, S.↗

On Accuracy of Adaptive Grid Methods for Captured Shocks

The accuracy of two grid adaptation strategies, grid redistribution and local grid refinement, is examined by solving the 2-D Euler equations for the supersonic steady flow around a cylinder. Second- and fourth-order linear finite difference shock-capturing schemes, based on the Lax-Friedrichs flux splitting, are used to discretize the governing equations. The grid refinement study shows that for the second-order scheme, neither grid adaptation strategy improves the numerical solution accuracy compared to that calculated on a uniform grid with the same number of grid points. For the fourth-order scheme, the dominant first-order error component is reduced by the grid adaptation, while the design-order error component drastically increases because of the grid nonuniformity. As a result, both grid adaptation techniques improve the numerical solution accuracy only on the coarsest mesh or on very fine grids that are seldom found in practical applications because of the computational cost involved. Similar error behavior has been obtained for the pressure integral across the shock. A simple analysis shows that both grid adaptation strategies are not without penalties in the numerical solution accuracy. Based on these results, a new grid adaptation criterion for captured shocks is proposed.

Yamaleev, Nail K.↗

Description of the F-16XL Geometry and Computational Grids Used in CAWAPI

The objective of the Cranked-Arrow Wing Aerodynamics Project International (CAWAPI) was to allow a comprehensive validation of Computational Fluid Dynamics methods against the CAWAP flight database. A major part of this work involved the generation of high-quality computational grids. Prior to the grid generation an IGES file containing the air-tight geometry of the F-16XL aircraft was generated by a cooperation of the CAWAPI partners. Based on this geometry description both structured and unstructured grids have been generated. The baseline structured (multi-block) grid (and a family of derived grids) has been generated by the National Aerospace Laboratory NLR. Although the algorithms used by NLR had become available just before CAWAPI and thus only a limited experience with their application to such a complex configuration had been gained, a grid of good quality was generated well within four weeks. This time compared favourably with that required to produce the unstructured grids in CAWAPI. The baseline all-tetrahedral and hybrid unstructured grids has been generated at NASA Langley Research Center and the USAFA, respectively. To provide more geometrical resolution, trimmed unstructured grids have been generated at EADS-MAS, the UTSimCenter, Boeing Phantom Works and KTH/FOI. All grids generated within the framework of CAWAPI will be discussed in the article. Both results obtained on the structured grids and the unstructured grids showed a significant improvement in agreement with flight test data in comparison with those obtained on the structured multi-block grid used during CAWAP.

Boelens, O. J.↗

Hydraulic performance evaluation of rod bundle with a concept spacer grid design

In a pressurized water reactor the spacer grid has a great influence on the thermal-hydraulic and mechanical properties of the fuel assembly. In order to improve the overall performance of the fuel assembly, a new concept spacer grid design names CATF with 'non-bending' guide vane is proposed. The hydraulic performance of the CATF grid design is evaluated by using a commercially computational fluid dynamics (CFD) code, ANSYS CFX12.1, and the evaluation result is compared with ordinary spacer grid including bending guide vane. Three dimensional rod bundles including CATF spacer grid and ordinary spacer grid have been simulated. The analysis results show that local resistance coefficient of CATF spacer grid is smaller than that of ordinary spacer grid by about 29.7% because of the non-bending guide vanes. Furthermore, the cross flow strength between subchannels near the outer strap area, the swirl strength and cross flow strength in subchannels near the outer strap area in 1-10 times hydraulic diameter downstream the spacer grid area of the ordinary grid, are larger than that of CATF spacer grid. The two types of spacer grids appear to have the same mixing characteristics in inner-grid area. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of grid growth on PWR spent fuel pool criticality analysis

Zircaloy based grids tend to grow with increasing fuel burnup. Grid growth increases the fuel pin pitch, which can increase fuel reactivity in the spent fuel pool. The amount of grid growth is dependent on the grid material. Zircaloy-4 grids tend to grow more than modern alloys such as Westinghouse Zirlo{sup TM} or AREVA M5{sup TM}, that have been developed, in part, to reduce irradiation growth. Grid growth has been included in the recent criticality analysis of the North Anna and Indian Point Unit 2 spent fuel pools. Grid growth is temperature dependent so the grid growth is not uniform over the axial length of the fuel. Above the active fuel is an Inconel grid which grows insignificantly. It has been conservatively assumed that the fuel pin pitch increases uniformly at all axial planes consistent with the maximum grid growth of any grid. Although this may seem overly conservative, the reactivity in the spent fuel pool for heavily burned fuel is dominated by the top few feet where the maximum grid growth occurs. At 50 GWd/MTU the grid growth is approximated as 0.47% for the Indian Point Unit 2 analysis. Assuming a uniform increase in pitch of 0.47% for 50 GWd/MTU fuel, the pool reactivity increases about 0.003 in k or about 0.6 GWd/MTU. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impacts of Sub‐Grid Topographic Representations on Surface Energy Balance and Boundary Conditions in the E3SM Land Model: A Case Study in Sierra Nevada

Abstract Sub‐grid topographic heterogeneity has large impacts on surface energy balance and land‐atmosphere interactions. However, the impacts of representing sub‐grid topographic effects in land surface models (LSMs) on surface energy balance and boundary conditions remain unclear. This study analyzed and evaluated the impacts of sub‐grid topographic representations on surface energy balance, turbulent heat flux, and scalar (co‐)variances in the Energy Exascale Earth System Model (E3SM) land model (ELM). Three sub‐grid topographic representations in ELM were compared: (a) the default sub‐grid structure (D), (b) the recently developed sub‐grid topographic structure (T), and (c) high spatial resolution (1KM). Additionally, two different solar radiation schemes in ELM were compared: (a) the default plane‐parallel radiative transfer scheme (PP) and (b) the parameterization scheme (TOP) that accounts for sub‐grid topographic effects on solar radiation. A series of offline simulations with the three grid discretization structures (D, T, and 1KM) and two schemes of solar radiation (TOP and PP) were carried out using the Sierra Nevada, California. 1KM simulations with TOP well capture the spatial heterogeneity of surface fluxes compared to Moderate Resolution Imaging Spectroradiometer remote sensing data. There are significant differences between TOP and PP in the 1‐km simulated surface energy balance, but the differences in mean values and standard deviations become small when aggregated to the grid scale (i.e., 0.5°). The T configuration better mimics the 1KM simulations with TOP than the D configuration and better captures the sub‐grid topographic effects on surface energy balance and boundary conditions. These results underline the importance of representing sub‐grid topographic heterogeneities in LSMs and motivate future research to understand the sub‐grid topographic effects on land‐atmosphere interactions over mountainous areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Refinement Techniques for the 𝜸-Re𝜽𝒕 Transition Model in FUN3D

There has been an increased focus on the overall accuracy and grid convergence of Reynolds-averaged Navier-Stokes (RANS)-based transition models from the recent AIAA and NATO-AVT workshops. Even though satisfactory grid convergence could be achieved for simple two-dimensional flow configurations, it required mesh counts that are substantially larger than those used in typical applications. In this paper, we focus our efforts on understanding how the grid resolution and topology influences the accuracy and convergence of results by studying the Schubauer and Skramstad flat-plate configuration and the NLF-0416 airfoil at an angle of attack equal to five degrees using FUN3D, a second-order finite-volume code. By focusing on these cases, we can analyze both natural and separation-induced transition scenarios. Multiple grid refinement strategies are investigated. First, we determine the relative effectiveness of zonal streamwise refinement in the transition region within structured grids as an alternative to the costly option of globally uniform refinement of a baseline grid. We also complement this zonal technique by globally varying the wall-normal resolution keeping the streamwise resolution fixed. The zonal streamwise refinement can accurately model natural transition in a flat-plate boundary layer and separation-induced transition, but struggles to accurately model natural transition in airfoil flows. A series of unstructured prismatic grids that have similar node counts and viscous wall spacings as the structured hexahedral grids are also tested, and they do not achieve grid convergence until an extremely fine resolution. Last, we employ adjoint-based unstructured grid adaptation in FUN3D to natural and separation-induced transition on the NLF-0416 airfoil. The adjoint-based refinement process converges to the same solution as the baseline family of structured grids, but leads to smaller errors on coarser grids.

Grid Adaptation↗

Grid Refinement Techniques for the 𝜸-Re 𝜽 𝒕 Transition Model in FUN3D

There has been an increased focus on the overall accuracy and grid convergence of Reynolds-averaged Navier-Stokes (RANS)-based transition models from the recent AIAA and NATO-AVT workshops. Even though satisfactory grid convergence could be achieved for simple two-dimensional flow configurations, it required mesh counts that are substantially larger than those used in typical applications. In this paper, we focus our efforts on understanding how the grid resolution and topology influences the accuracy and convergence of results by studying the Schubauer and Skramstad flat-plate configuration and the NLF-0416 airfoil at an angle of attack equal to five degrees using FUN3D, a second-order finite-volume code. By focusing on these cases, we can analyze both natural and separation-induced transition scenarios. Multiple grid refinement strategies are investigated. First, we determine the relative effectiveness of zonal streamwise refinement in the transition region within structured grids as an alternative to the costly option of globally uniform refinement of a baseline grid. We also complement this zonal technique by globally varying the wall-normal resolution keeping the streamwise resolution fixed. The zonal streamwise refinement can accurately model natural transition in a flat-plate boundary layer and separation-induced transition, but struggles to accurately model natural transition in airfoil flows. A series of unstructured prismatic grids that have similar node counts and viscous wall spacings as the structured hexahedral grids are also tested, and they do not achieve grid convergence until an extremely fine resolution. Last, we employ adjoint-based unstructured grid adaptation in FUN3D to natural and separation-induced transition on the NLF-0416 airfoil. The adjoint-based refinement process converges to the same solution as the baseline family of structured grids, but leads to smaller errors on coarser grids.

Grid Adaptation↗

Control, Operation, and Stability Characteristics of Grid-Forming Type III Wind Turbines: Preprint

This paper explores the control, operation, and stability characteristics of grid-forming Type III wind turbines. The paper shows that the grid-forming operation mode requires redesign of only the slower control loops for active and reactive power control, whereas the faster current control implementation can stay the same as grid-following turbines. The paper also shows that grid-forming wind turbines face higher mechanical stress than grid-following wind turbines because of the slower speed of the active power control. This stress, however, can be mitigated using advanced pitch control. The paper compares the stability characteristics of the grid-forming and grid-following operation modes of Type III turbines by comparing sequence impedance responses for both operation modes. It is found that, unlike standard Type III wind turbines, the grid-forming mode substantially reduces the risks of subsynchronous oscillations during operation with series-compensated transmission lines. Moreover, the grid-forming Type III turbines can operate stably with extremely weak grids. The findings of this paper are validated using EMT-PSCAD simulations of a 2.5-MW turbine operating in both grid-forming and grid-following modes.

49 EE - Wind and Water Power Program - Wind (EE-4W↗