Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

The Role of Radiation-Induced Non-Equilibrium Plutonium Oxidation States in Solution

Plutonium plays a key role in global actinide research and nuclear fuel cycle technologies, and yet, our fundamental understanding of its inherent radiation-induced chemical behavior is limited. These radiation-induced processes cannot simply be switched off, as they are as fundamentally inherent to plutonium as the impact of relativistic effects on its f-electrons. In less chemically complex actinide systems, such as aqueous solutions of neptunium and americium, both steady-state and transient radiolysis products play a significant role in the redox cycling of their oxidation states, which ultimately impacts their chemistry and transport. However, plutonium's multiple, coexisting, and chemically active oxidation states, which comprise of bare ions and dioxo cations, provide additional redox pathways that complicate the aforementioned radiation-induced competition kinetics. Mechanistically understanding the response of these multiple oxidation states, both equilibrium and non-equilibrium, to intense ionizing radiation fields is essential for predicting the behavior of plutonium under a host of conditions that support technological innovation in global nuclear energy and non-proliferation efforts. Here, advances in radiation-induced plutonium solution chemistry will be presented, including new results from time-resolved electron pulse and steady-state gamma and alpha irradiations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-LET radiation-induced aberrations in prematurely condensed G2 chromosomes of human fibroblasts

PURPOSE: To determine the number of initial chromatid breaks induced by low- or high-LET irradiations, and to compare the kinetics of chromatid break rejoining for radiations of different quality. MATERIAL AND METHODS: Exponentially growing human fibroblast cells AG1522 were irradiated with gamma-rays, energetic carbon (290MeV/u), silicon (490MeV/u) and iron (200 and 600 MeV/u). Chromosomes were prematurely condensed using calyculin A. Chromatid breaks and exchanges in G2 cells were scored. PCC were collected after several post-irradiation incubation times, ranging from 5 to 600 min. RESULTS: The kinetics of chromatid break rejoining following low- or high-LET irradiation consisted of two exponential components representing a rapid and a slow time constant. Chromatid breaks decreased rapidly during the first 10min after exposure, then continued to decrease at a slower rate. The rejoining kinetics were similar for exposure to each type of radiation. Chromatid exchanges were also formed quickly. Compared to low-LET radiation, isochromatid breaks were produced more frequently and the proportion of unrejoined breaks was higher for high-LET radiation. CONCLUSIONS: Compared with gamma-rays, isochromatid breaks were observed more frequently in high-LET irradiated samples, suggesting that an increase in isochromatid breaks is a signature of high-LET radiation exposure.

Non-NASA Center↗

Effect of fast neutron, gamma-ray and combined radiations on the thermal decomposition of ammonium perchlorate single crystals

The thermal decomposition kinetics have been determined for ammonium perchlorate crystals subjected to a fast neutron irradiation or to a fast neutron irradiation followed by a gamma-ray irradiation. Qualitatively, the radiation induced changes are similar to those obtained in this and in previous studies, with samples exposed only to gamma rays. The induction period is shortened and the rate constants, obtained from an Avrami-Erofeyev kinetic analysis, are modified. The acceleratory period constant increases and the decay period constant decreases. When compared on an equal deposited energy basis, the fast neutron induced changes are appreciably larger than the gamma-ray induced changes. Some, or all, of the fast neutron induced effects might be attributable to the introduction of localized regions of concentrated radiation damage ('spikes') by lattice atom recoils which become thermal decomposition sites when the crystals are heated.

Herley, P. J.↗

Gamma-Weighted Discrete Ordinate Two-Stream Approximation for Computation of Domain Averaged Solar Irradiance

An algorithm is developed for the gamma-weighted discrete ordinate two-stream approximation that computes profiles of domain-averaged shortwave irradiances for horizontally inhomogeneous cloudy atmospheres. The algorithm assumes that frequency distributions of cloud optical depth at unresolved scales can be represented by a gamma distribution though it neglects net horizontal transport of radiation. This algorithm is an alternative to the one used in earlier studies that adopted the adding method. At present, only overcast cloudy layers are permitted.

Kato, S.↗

Multi-Omics Analysis of Mouse Retina Following Low Dose Radiation and/or Hindlimb Unloading

Rodent models have been used as analogs for studying the effects of spaceflight. NASA’s GeneLab provides access to omics datasets generated from spaceflight and ground-based experiments allowing for additional retrospective analysis. We used GeneLab’s GLDS-203, a dataset generated by researchers at Loma Linda University to study the impact of prolonged unloading and/or low-dose radiation on mouse retina. The purpose of this study was to understand the effect of gamma radiation and/or hindlimb unloading on mice retinas through a multi-omics analysis. In the experiment that generated the omics data, mice were irradiated with gamma-ray and/or subjected to hindlimb unloading for 21 days and multi-omics analysis was performed at 7 days, 1 month, or 4 months post exposure. In the current study, for each of the three timepoints, we compared epigenomic profiles for retinas from exposed mice against timepoint-matched controls. We identified a total of 5,271 differentially methylated loci (DML) and 321 differentially methylated regions (DMR; using a sliding window and step size of 500 bp) with methylation difference > 10% and q-value < 0.05 (sliding linear model corrected p-value) across the nine exposure groups. Highest correlation in methylation difference was seen for significant DMLs (q-value < 0.05) across different conditions at same post exposure timepoint (Figure 1).The location of DMLs and DMRs were characterized with respect to CpG islands and shores, putative promoters, gene body, and intergenic regions (Table 1). We analyzed RNA-seq counts and performed gene set enrichment analysis using differential expression results from comparing each exposure group to its timepoint-matched control group. Significant pathways (adjusted p-value <0.05) enriched in all three microgravity-only groups were related to morphogenesis of a branching epithelium, skeletal muscle cell differentiation, and response to fibroblast growth factor. Common processes across all timepoints in the radiation-only groups were retina homeostasis, synaptic vesicle exocytosis-endocytosis, and chemotaxis. In the combination groups, regulation of trans-synaptic signaling, and Rho protein signal transduction were enriched at all three timepoints. Processes related to purine nucleotide metabolism were enriched in all nine exposure groups, with activation at 1 month, and suppression at 7 days and 4 months. A total of 14 genes contained at least one DML and were differentially expressed at adjusted p-value < 0.05, including genes implicated in cataract development (Sipa1l3, Crybb3) and those involved in cytoskeletal organization (Plec, Flnb, Eef1a1). This analysis is part of a larger effort to understand the molecular mechanisms following spaceflight exposures that can help translate effects observed in animal models to human impacts.

Prachi Kothiyal↗

Neutron, gamma ray, and temperature effects on the electrical characteristics of thyristors

Experimental data showing the effects of neutrons, gamma rays, and temperature on the electrical and switching characteristics of phase-control and inverter-type SCR's are presented. The special test fixture built for mounting, heating, and instrumenting the test devices is described. Four SCR's were neutron irradiated at 300 K and four at 365 K for fluences up to 3.2 x 10 exp 13 n/sq. cm, and eight were gamma irradiated at 300 K only for gamma doses up to 5.1 Mrads. The electrical measurements were made during irradiation and the switching measurements were made only before and after irradiation. Radiation induced crystal defects, resulting primarily from fast neutrons, caused the reduction of minority carrier lifetime through the generation of R-G centers. The reduction in lifetime caused increases in the on-state voltage drop and in the reverse and forward leakage currents, and decreases in the turn-off time.

Frasca, A. J.↗

Neutron, gamma ray, and temperature effects on the electrical characteristics of thyristors

Experimental data showing the effects of neutrons, gamma rays, and temperature on the electrical and switching characteristics of phase-control and inverter-type SCR's are presented. The special test fixture built for mounting, heating, and instrumenting the test devices is described. Four SCR's were neutron irradiated at 300 K and four at 365 K for fluences up to 3.2 x 10 exp 13 pn/sq. cm, and eight were gamma irradiated at 300 K only for gamma doses up to 5.1 Mrads. The electrical measurements were made during irradiation and the switching measurements were made only before and after irradiation. Radiation induced crystal defects, resulting primarily from fast neutrons, caused the reduction of minority carrier lifetime through the generation of R-G centers. The reduction in lifetime caused increases in the on-state voltage drop and in the reverse and forward leakage currents, and decreases in the turn-off time.

Frasca, A. J.↗

Kinetics of chromatid break repair in G2-human fibroblasts exposed to low- and high-LET radiations

The purpose of this study is to determine the kinetics of chromatid break rejoining following exposure to radiations of different quality. Exponentially growing human fibroblast cells AG1522 were irradiated with gamma-rays, energetic carbon (290 MeV/u), silicon (490 MeV/u) and iron (200 MeV/u, 600 MeV/u). Chromosomes were prematurely condensed using calyculin A. Prematurely condensed chromosomes were collected after several post-irradiation incubation times, ranging from 5 to 600 minutes, and the number of chromatid breaks and exchanges in G2 cells were scored. The relative biological effectiveness (RBE) for initial chromatid breaks per unit dose showed LET dependency having a peak at 55 keV/micrometers silicon (2.4) or 80 keV/micrometers carbon particles (2.4) and then decreased with increasing LET. The kinetics of chromatid break rejoining following low- or high-LET irradiation consisted of two exponential components. Chromatid breaks decreased rapidly after exposure, and then continued to decrease at a slower rate. The rejoining kinetics was similar for exposure to each type of radiation, although the rate of unrejoined breaks was higher for high-LET radiation. Chromatid exchanges were also formed quickly.

NASA Center JSC↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Irradiation performance of nonfertile (Pu-MA-Zr) fast reactor metal fuels

This work was part of a program begun in 2001 to develop advanced nuclear fuels, originally as carriers for plutonium and minor actinides (neptunium, curium, and americium) taken from spent commercial light-water reactors (LWR) so that the plutonium and minor actinides could be ‘burned’ or transmuted in an accelerator or a fast nuclear reactor. A central part of these experiment programs has been the development of advanced fast reactor fuels, because a fast reactor was considered the most efficient vehicle to transmute the actinide waste products, and metallic fuels is a central focus of these tests. An experiment design was developed in which a thermal test reactor, the Advanced Test Reactor (ATR), was used to test small fuel pin prototypes, by creating areas in the core shielded by cadmium filters to produce a largely epithermal and fast neutron spectrum environment in which the pins could be irradiated. The results of non-fertile metallic fuel (no uranium) tests are presented here. Pu-Am-Np-Zr fuels were irradiated to fission densities up to 33 × 10 20 fission/cm 3 and Pu-239 depletions of up to 39%. The depletions were created by roughly 2/3 by fission and 1/3 by transmutation neutron capture. Up to five fuel ‘rodlets’ were irradiated in three sealed capsules stacked axially in the core, and the peak cladding temperatures ranged from 300°C to 500°C, depending on axial location as those near the core centerline are operating hotter and to higher fission densities. Several post-irradiation examinations (precision gamma scanning and fission gas release) were similar to other historical metal fuel experiments in fast reactors. However, optical metallography indicated that two of the rodlets had breached. The exact reasons are unclear. Due to the design of this irradiation experiment a rodlet breach could have increased the temperature in others in the same capsule by contaminating the thermal gap helium with heavier and less conductive fission product gases. Finally, some of those rodlets showed high amounts of fuel/cladding chemical interaction (FCCI).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Energy Dependent Fission Product Yields

This project utilized a 10-meter Fast Transfer System (called RABITTS) and Decay Station. FPYs are measured using neutron activation of U-235 and Pu-239 followed by gamma ray spectroscopy. We irradiated targets with mono-energetic neutrons produced at the TUNL tandem accelerator laboratory. The gamma spectra collected in these target irradiations are being analyzed to determine FPY values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Transcriptomic Analysis of Irradiated Mouse Retina Following Readaptation

Rodent models are used as analogs for studying the effects of spaceflight. NASA GeneLab provides access to relevant omics datasets generated from spaceflight and ground-based experiments allowing for additional retrospective analysis. In this study, we used GeneLab’s GLDS-203, a dataset generated by researchers at Loma Linda University to study the impact of prolonged unloading and/or low-dose radiation on mouse retina. We analyzed transcriptomics data from retina of mice irradiated with gamma-rays for 21 days followed by 7 days, 1 month, or 4 months of readaptation. We obtained raw gene counts from GeneLab and performed differential gene expression analysis after data normalization. For each of the three timepoints, we performed differential expression analysis to compare transcriptional profiles for retina from irradiated vs. non-irradiated (controls) mice, all exposed to gravity. We observed the highest number of differentially expressed genes at 7 days, followed by 1 month and 4 months. Enrichment analysis showed top pathways (adjusted p-value < 0.05) were related to transport along microtubule and photoreceptor cell development in the 7-day readaptation group. Fewer significantly enriched pathways were observed for the 1-month group and included mRNA metabolic processes and neuron differentiation. No significantly enriched pathways were found in the 4-month group. The Gene Ontology biological processes common between the 7 days and 1-month groups include visual perception, synapse organization, and perception of light stimulus. This analysis is part of a larger effort to characterize the molecular mechanisms involved in retinal readaptation following radiation exposure. Future analyses will include other related retina datasets in GeneLab repository to assess whether gene expression patterns are consistent across different study cohorts.

Prachi Kothiyal↗

Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV–Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV–Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗