Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLANDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Social Isolation Impacts Select Responses to Simulated Weightlessness

The rodent hindlimb unloading (HU) model was initially developed to simulate the cephalad fluid shift and musculoskeletal disuse in astronauts. Since then, the HU model has been applied to explore how other systems (e.g. immune, cardiovascular and CNS) respond to weightlessness. Most HU studies are performed with singly-housed animals, although social isolation also can substantially impact behavior and physiology, and therefore may confound HU experimental results. We hypothesized that relative to social housing, single housing exacerbates HU-induced dysfunction in select organ systems. We refined the standard NASA-Ames HU model to accommodate social housing in HU pairs, retaining advantageous features of traditional housing but using commercial off-the-shelf components to facilitate adoption by others. We conducted a 30 day HU experiment with adult, female C57Bl6/NJ mice that were either singly or socially housed. HU animals in both single and social HU housing displayed expected musculoskeletal deficits compared to housing matched, normally loaded (NL) controls. However, select immune, HPA axis, and CNS responses were differentially impacted by the HU social environment relative to NL controls. HU reduced % CD4+ T cells in singly-housed, but not socially-housed mice. Surprisingly, HU increased adrenal gland mass in socially-housed but not singly-housed mice, while social isolation increased adrenal gland mass in NL controls. HU also increased plasma corticosterone levels (day 30) in both singly and socially-housed mice. Thus, the social environment altered select adrenal and immune, but not musculoskeletal, responses to simulated weightlessness. We refine our original hypothesis since our results show combined stressors can mask, not only exacerbate, tissue responses to HU. These findings further expand the utility of the HU model for studying possible combined effects of the various spaceflight stressors.

Tahimic, Candice↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

Thyroid Function in Women after Multimodal Treatment for Breast Cancer Stage II/III: Comparison With Controls From a Population Sample

Purpose: A possible association between thyroid diseases (TD) and breast cancer (BC) has been debated. We examined prevalence and development of TD in women after multimodal treatment for Stage II/III BC compared with women from a general population. Secondarily, we explored the impact of two different radiotherapy (RT) techniques (standardized field arrangements vs. computed tomography [CT]-based dose planning) on TD in BC patients examined 35-120 months after primary BC treatment. Methods and Materials: A total of 403 BC patients completed a questionnaire about TD and had blood samples taken for analyses of thyroid function. All had undergone postoperative RT with or without (2%) adjuvant systemic treatment. The results in the BC patients were compared with a cancer-free, age-matched control group from a general population (CGr). Results: There was higher prevalence of self-reported hypothyroidism in the BC patients as compared with the CGr (18% vs. 6%, p < 0.001). The raised prevalence was predominantly due to a substantial increase in the development of hypothyroidism after BC diagnosis, whereas the prevalence of hypothyroidism before BC diagnosis was similar to that observed in the CGr. Patients treated with CT-based RT showed a trend for increased post-BC development of hypothyroidism as compared with those treated with standardized field arrangements (p = 0.08). Conclusions: Hypothyroidism is significantly increased in women after multimodal treatment for Stage II/III BC. Radiation to the thyroid gland may be a contributing factor. BC patients should be routinely screened for hypothyroidism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cancer epidemiology update, following the 2011 IARC evaluation of radiofrequency electromagnetic fields (Monograph 102)

Highlights: • Increased risk of brain, vestibular nerve and salivary gland tumors are associated with mobile phone use. • Nine studies (2011–2017) report increased risk of brain cancer from mobile phone use. • Four case-control studies (3 in 2013, 1 in 2014) report increased risk of vestibular nerve tumors. • Concern for other cancers: breast (male & female), testis, leukemia, and thyroid. • Based on the evidence reviewed it is our opinion that IARC's current categorization of RFR as a possible human carcinogen (Group 2B) should be upgraded to Carcinogenic to Humans (Group 1). Epidemiology studies (case-control, cohort, time trend and case studies) published since the International Agency for Research on Cancer (IARC) 2011 categorization of radiofrequency radiation (RFR) from mobile phones and other wireless devices as a possible human carcinogen (Group 2B) are reviewed and summarized. Glioma is an important human cancer found to be associated with RFR in 9 case-control studies conducted in Sweden and France, as well as in some other countries. Increasing glioma incidence trends have been reported in the UK and other countries. Non-malignant endpoints linked include acoustic neuroma (vestibular Schwannoma) and meningioma. Because they allow more detailed consideration of exposure, case-control studies can be superior to cohort studies or other methods in evaluating potential risks for brain cancer. When considered with recent animal experimental evidence, the recent epidemiological studies strengthen and support the conclusion that RFR should be categorized as carcinogenic to humans (IARC Group 1). Opportunistic epidemiological studies are proposed that can be carried out through cross-sectional analyses of high, medium, and low mobile phone users with respect to hearing, vision, memory, reaction time, and other indicators that can easily be assessed through standardized computer-based tests. As exposure data are not uniformly available, billing records should be used whenever available to corroborate reported exposures.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Stereotactic Body Radiotherapy for Treatment of Adrenal Metastases

Purpose: To investigate the dosimetry and outcomes of patients undergoing stereotactic body radiotherapy (SBRT) for metastases to the adrenal glands. Methods and Materials: At University of Rochester, patients have been undergoing SBRT for limited metastases since 2001. We retrospectively reviewed 30 patients who had undergone SBRT for adrenal metastases from various primary sites, including lung (n = 20), liver (n = 3), breast (n = 3), melanoma (n = 1), pancreas (n = 1), head and neck (n = 1), and unknown primary (n = 1). Results: Of the 30 patients, 14 with five or fewer metastatic lesions (including adrenal) underwent SBRT, with the intent of controlling all known sites of metastatic disease, and 16 underwent SBRT for palliation or prophylactic palliation of bulky adrenal metastases. The prescribed dose ranged from 16 Gy in 4 fractions to 50 Gy in 10 fractions. The median dose was 40 Gy. Of the 30 patients, 24 had >3 months of follow-up with serial computed tomography. Of these 24 patients, 1 achieved a complete response, 15 achieved a partial response, 4 had stable disease, and 4 developed progressive disease. No patient developed symptomatic progression of their adrenal metastases. The 1-year survival, local control, and distant control rate was 44%, 55%, and 13%, respectively. No patient developed Radiation Therapy Oncology Group Grade 2 or greater toxicity. Conclusion: SBRT for adrenal metastases is well tolerated. Most patients developed widespread metastases shortly after treatment. Local control was poor, although this was a patient population selected for adverse risk factors, such as bulky disease. Additional studies are needed to determine the efficacy of SBRT for oligometastatic adrenal metastases, given the propensity of these patients to develop further disease progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Radiotherapy Interruptions on Survival in Medicare Enrollees With Local and Regional Head-and-Neck Cancer

Purpose: To investigate whether interruptions in radiotherapy are associated with decreased survival in a population-based sample of head-and-neck cancer patients. Methods and Materials: Using the Surveillance, Epidemiology, and End Results-Medicare linked database we identified Medicare beneficiaries aged 66 years and older diagnosed with local-regional head-and-neck cancer during the period 1997-2003. We examined claims records of 3864 patients completing radiotherapy for the presence of one or more 5-30-day interruption(s) in therapy. We then performed Cox regression analyses to estimate the association between therapy interruptions and survival. Results: Patients with laryngeal tumors who experienced an interruption in radiotherapy had a 68% (95% confidence interval, 41-200%) increased risk of death, compared with patients with no interruptions. Patients with nasal cavity, nasopharynx, oral, salivary gland, and sinus tumors had similar associations between interruptions and increased risk of death, but these did not reach statistical significance because of small sample sizes. Conclusions: Treatment interruptions seem to influence survival time among patients with laryngeal tumors completing a full course of radiotherapy. At all head-and-neck sites, the association between interruptions and survival is sensitive to confounding by stage and other treatments. Further research is needed to develop methods to identify patients most susceptible to interruption-induced mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Dose Addition of External Beam Radiotherapy and Brachytherapy for Oropharyngeal Patients Using Nonrigid Registration

Purpose: To develop and evaluate a method for adding dose distributions of combined external beam radiotherapy (EBRT) and brachytherapy (BT) for oropharyngeal patients. Methods and Materials: Two computed tomography (CT) scans were used for 5 patients: the EBRT CT, used for EBRT planning, and the BT CT, acquired after catheter implantation. For each scan, the salivary glands and the chewing and swallowing muscles were contoured, and a dose distribution was calculated. A nonrigid transformation was obtained by registering the organs' surfaces. Then the BT dose distribution was mapped onto the EBRT dose distribution by applying the transformation obtained. To account for differences in fractionation, the physical doses were converted to equivalent dose in 2 Gy (EQD{sub 2}), and the total dose was found by adding dose voxel by voxel. The robustness of the dose addition was investigated by varying delineations and input parameters of the registration method and by varying the {alpha}/{beta} parameter for EQD{sub 2}. The effect of the perturbations was quantified using dose-volume histograms (DVH) and gamma analyses (distance-to-agreement/dose-difference = 1 mm/1 Gy). Results: The variations in input parameters and delineations caused only small perturbations in the DVH of the added dose distributions. For most organs the gamma index was low, and it was moderately elevated for organs lying in areas with a steep gradient (median gamma index {<=}2.3 for constrictor muscles, {<=}0.7 for all other organs). Conclusions: The presented method allows adding dose distributions of combined EBRT and BT for oropharyngeal patients. In general, the method is reliable and robust with respect to uncertainties in organ delineation, perturbations in input parameters of the method, and {alpha}/{beta} values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemo-IMRT of Oropharyngeal Cancer Aiming to Reduce Dysphagia: Swallowing Organs Late Complication Probabilities and Dosimetric Correlates

Purpose: Assess dosimetric correlates of long-term dysphagia after chemo-intensity-modulated radiotherapy (IMRT) of oropharyngeal cancer (OPC) sparing parts of the swallowing organs. Patients and Methods: Prospective longitudinal study: weekly chemotherapy concurrent with IMRT for Stages III/IV OPC, aiming to reduce dysphagia by sparing noninvolved parts of swallowing-related organs: pharyngeal constrictors (PC), glottic and supraglottic larynx (GSL), and esophagus, as well as oral cavity and major salivary glands. Dysphagia outcomes included patient-reported Swallowing and Eating Domain scores, Observer-based (CTCAEv.2) dysphagia, and videofluoroscopy (VF), before and periodically after therapy through 2 years. Relationships between dosimetric factors and worsening (from baseline) of dysphagia through 2 years were assessed by linear mixed-effects model. Results: Seventy-three patients participated. Observer-based dysphagia was not modeled because at >6 months there were only four Grade {>=}2 cases (one of whom was feeding-tube dependent). PC, GSL, and esophagus mean doses, as well as their partial volume doses (V{sub D}s), were each significantly correlated with all dysphagia outcomes. However, the V{sub D}s for each organ intercorrelated and also highly correlated with the mean doses, leaving only mean doses significant. Mean doses to each of the parts of the PCs (superior, middle, and inferior) were also significantly correlated with all dysphagia measures, with superior PCs demonstrating highest correlations. For VF-based strictures, most significant predictor was esophageal mean doses (48{+-}17 Gy in patients with, vs 27{+-}12 in patients without strictures, p = 0.004). Normal tissue complication probabilities (NTCPs) increased moderately with mean doses without any threshold. For increased VF-based aspirations or worsened VF summary scores, toxic doses (TDs){sub 50} and TD{sub 25} were 63 Gy and 56 Gy for PC, and 56 Gy and 39 Gy for GSL, respectively. For both PC and GSL, patient-reported swallowing TDs were substantially higher than VF-based TDs. Conclusions: Swallowing organs mean doses correlated significantly with long-term worsening of swallowing. Different methods assessing dysphagia resulted in different NTCPs, and none demonstrated a threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association between organophosphate pesticides exposure and thyroid hormones in floriculture workers

The ability of organophosphate pesticides to disturb thyroid gland function has been demonstrated by experimental studies on animal, but evidence of such effects on human remains scarce. The aim of this study was to assess the association between exposure to organophosphate compounds and serum levels of thyroid hormones in floriculture workers. A longitudinal study was conducted on 136 male subjects from the State of Mexico and Morelos, Mexico, occupationally exposed to organophosphate pesticides, during agricultural periods of high (rainy season) and low (dry season) levels of pesticide application. Using a structured questionnaire, a survey was carried out on sociodemographic characteristics, anthropometry, clinical history, alcohol and tobacco consumption, residential chemical exposure, and occupational history. Urine and blood samples were taken the day after pesticide application to determine urine dialkylphosphate (DAP) levels, serum levels of TSH, total T{sub 3}, total T{sub 4}, serum PON1 activity, and serum p,p'-DEE levels. The analysis of the association between DAP levels and thyroid hormonal profile was carried out using multivariate generalized estimating equation (GEE) models. Our results showed an increase in both TSH and T{sub 4} hormones in serum associated with a increase in total dimethylphosphate levels (SIGMADMP) in urine (p-trend < 0.001) and a decrease in total T{sub 3} serum levels with an increase of SIGMADMP levels in the urine (p-trend = 0.053). These results suggest that exposure to organophosphate pesticides may be responsible of increasing TSH and T{sub 4} serum hormone levels and decreasing T{sub 3} serum hormone levels, therefore supporting the hypothesis that organophosphate pesticides act as endocrine disruptors in humans.

60 APPLIED LIFE SCIENCES↗

Toxicity and toxicokinetics of metformin in rats

Metformin is a first-line drug for the treatment of type 2 diabetes (T2D) and is often prescribed in combination with other drugs to control a patient's blood glucose level and achieve their HbA1c goal. New treatment options for T2D will likely include fixed dose combinations with metformin, which may require preclinical combination toxicology studies. To date, there are few published reports evaluating the toxicity of metformin alone to aid in the design of these studies. Therefore, to understand the toxicity of metformin alone, Crl:CD(SD) rats were administered metformin at 0, 200, 600, 900 or 1200 mg/kg/day by oral gavage for 13 weeks. Administration of >= 900 mg/kg/day resulted in moribundity/mortality and clinical signs of toxicity. Other adverse findings included increased incidence of minimal necrosis with minimal to slight inflammation of the parotid salivary gland for males given 1200 mg/kg/day, body weight loss and clinical signs in rats given >= 600 mg/kg/day. Metformin was also associated with evidence of minimal metabolic acidosis (increased serum lactate and beta-hydroxybutyric acid and decreased serum bicarbonate and urine pH) at doses >= 600 mg/kg/day. There were no significant sex differences in mean AUC{sub 0-24} or C{sub max} nor were there significant differences in mean AUC{sub 0-24} or C{sub max} following repeated dosing compared to a single dose. The no observable adverse effect level (NOAEL) was 200 mg/kg/day (mean AUC{sub 0-24} = 41.1 mug h/mL; mean C{sub max} = 10.3 mug/mL based on gender average week 13 values). These effects should be taken into consideration when assessing potential toxicities of metformin in fixed dose combinations.

60 APPLIED LIFE SCIENCES↗

Perchlorate transport and inhibition of the sodium iodide symporter measured with the yellow fluorescent protein variant YFP-H148Q/I152L

Perchlorate is an environmental contaminant that impairs thyroid function by interacting with the sodium iodide symporter (NIS), the transporter responsible for iodide uptake in the thyroid gland. Perchlorate is well known as a competitive inhibitor of iodide transport by NIS, and recent evidence demonstrates that NIS can also transport perchlorate. In this study, we evaluated the yellow fluorescent protein (YFP) variant YFP-H148Q/I152L, as a genetically encodable biosensor of intracellular perchlorate concentration monitored by real-time fluorescence microscopy. Fluorescence of recombinant YFP-H148Q/I152L was suppressed by perchlorate and iodide with similar affinities of 1.2 mM and 1.6 mM, respectively. Perchlorate suppressed YFP-H148Q/I152L fluorescence in FRTL-5 thyroid cells and NIS-expressing COS-7 cells, but had no effect on COS-7 cells lacking NIS. Fluorescence changes in FRTL-5 cells were Na{sup +}-dependent, consistent with the Na{sup +}-dependence of NIS activity. Perchlorate uptake in FRTL-5 cells resulted in 10-fold lower intracellular concentrations than iodide uptake, and was characterized by a higher affinity (K{sub m} 4.6 muM for perchlorate and 34.8 muM for iodide) and lower maximal velocity (V{sub max} 6.8 muM/s for perchlorate and 39.5 muM/s for iodide). Perchlorate also prevented iodide-induced changes in YFP-H148Q/I152L fluorescence in FRTL-5 cells, with half-maximal inhibition occurring at 1.1-1.6 muM. In conclusion, YFP-H148Q/I152L detects perchlorate accumulation by thyroid and other NIS-expressing cells, and reveals differences in the kinetics of perchlorate versus iodide transport by NIS.

60 APPLIED LIFE SCIENCES↗

Interaction between organophosphate pesticide exposure and PON1 activity on thyroid function

Organophosphate pesticides are widely used in agricultural purposes. Recently, a few studies have demonstrated the ability of these chemicals to alter the function of the thyroid gland in human. Moreover, the paraoxonase-1 enzyme (PON1) plays an important role in the toxicity of some organophosphate pesticides, with low PON1 activity being associated with higher pesticide sensitivity. This study evaluates the interaction between exposure to organophosphate compounds and PON1 enzyme activity on serum levels of TSH and thyroid hormones in a population of workers occupationally exposed to pesticides. A longitudinal study was conducted on a population of floriculture workers from Mexico, during two periods of high and low-intensity levels of pesticide application. A structured questionnaire was completed by workers containing questions on sociodemographic characteristics and other variables of interest. Urine and blood samples were taken, and biomarkers of exposure (dialkylphosphates), susceptibility (PON1 polymorphisms and activity) and effect (thyroid hormone levels) were determined. Interaction between dialkylphosphates and PON1 polymorphisms or PON1 activity on hormone levels was evaluated by generalized estimating equation (GEE) models. A significant interaction was found between serum diazoxonase activity and total dialkylphosphates ({Sigma}DAP) on TSH levels. Thus, when PON1 activity was increased we observed a decrease in the percentage of variation of TSH level for each increment in one logarithmic unit of the {Sigma}DAP levels. This interaction was also observed with the PON1{sub 192}RR genotype. These results suggest a stronger association between organophosphate pesticides and thyroid function in individuals with lower PON1 activity.

60 APPLIED LIFE SCIENCES↗

A new Phytoreovirus infecting the glassy-winged sharpshooter (Homalodisca vitripennis)

A new virus species of the genus Phytoreovirus was isolated from glassy-winged sharpshooter (GWSS), Homalodisca vitripennis Germar (Hemiptera: Cicadellidae), in California and designated here as Homalodisca vitripennis reovirus (HoVRV). Extraction of nucleic acid from GWSS adults collected from three Californian populations revealed an array of double-stranded (ds) RNA species that was soluble in 2 M LiCl and resistant to degradation upon exposure to S1 nuclease and DNase. Analysis of nucleic acid samples from single GWSS adults indicated that HoVRV dsRNA accumulated to high titer in individual insects. Double-shelled isometric virus particles purified from GWSS adults resembled those observed in thin sections of GWSS salivary glands by transmission electron microscopy. Purified HoVRV virions contained 12 dsRNA segments that, based on complete nucleotide sequences, ranged in size from 4475 to 1040 bp. Sequence comparisons indicated that the HoVRV dsRNA segments were most closely related (58.5 to 43.7% nt sequence identity) to the corresponding genome segments of Rice dwarf virus (RDV). Each HoVRV dsRNA segment encoded a single open reading frame (> 300 nts) except for segment 11, which appears to be dicistronic. Terminal nucleotide sequences of HoVRV positive-sense RNAs were similar to other phytoreoviruses (GGCG or GGCA at the 5'-end and UGAU or CGAU at the 3'-end) with adjacent imperfect inverted repeats potentially able to base pair. Phylogenetic analyses of the RNA-directed RNA polymerase (encoded by segment 1) and the outer capsid protein (encoded by segment 8) confirmed placement of HoVRV as a species of the genus Phytoreovirus sharing a most recent common ancestor with RDV. Reverse transcription-polymerase chain reaction assays revealed that HoVRV infection of GWSS in California was common and that the virus also occurred in GWSS populations from the Carolinas and Texas.

60 APPLIED LIFE SCIENCES↗

Neutron dosimetry in organs of an adult human phantom using linacs with multileaf collimator in radiotherapy treatments

Purpose: To calculate absorbed doses due to neutrons in 87 organs/tissues for anthropomorphic phantoms, irradiated in position supine (head first into the gantry) with orientations anteroposterior (AP) and right-left (RLAT) with a 18 MV accelerator. Conversion factors from monitor units to {mu}Gy per neutron in organs, equivalent doses in organs/tissues, and effective doses, which permit to quantify stochastic risks, are estimated. Methods: MAX06 and FAX06 phantoms were modeled with MCNPX and irradiated with a 18 MV Varian Clinac 2100C/D accelerator whose geometry included a multileaf collimator. Two actual fields of a pelvic treatment were simulated using electron-photon-neutron coupled transport. Absorbed doses due to neutrons were estimated from kerma. Equivalent doses were estimated using the radiation weighting factor corresponding to an average incident neutron energy 0.47 MeV. Statistical uncertainties associated to absorbed doses, as calculated by MCNPX, were also obtained. Results: Largest doses were absorbed in shallowest (with respect to the neutron pathway) organs. In {mu}GyMU{sup -1}, values of 2.66 (for penis) and 2.33 (for testes) were found in MAX06, and 1.68 (for breasts), 1.05 (for lenses of eyes), and 0.94 (for sublingual salivary glands) in FAX06, in AP orientation. In RLAT, the largest doses were found for bone tissues (leg) just at the entrance of the beam in the body (right side in our case). Values, in {mu}GyMU{sup -1}, of 1.09 in upper leg bone right spongiosa, for MAX06, and 0.63 in mandible spongiosa, for FAX06, were found. Except for gonads, liver, and stomach wall, equivalent doses found for FAX06 were, in both orientations, higher than for MAX06. Equivalent doses in AP are higher than in RLAT for all organs/tissues other than brain and liver. Effective doses of 12.6 and 4.1 {mu}SvMU{sup -1} were found for AP and RLAT, respectively. The organs/tissues with larger relative contributions to the effective dose were testes and breasts, in AP, and breasts and red marrow, in RLAT. Equivalent and effective doses obtained for MAX06/FAX06 were smaller (between 2 and 20 times) than those quoted for the mathematical phantoms ADAM/EVA in ICRP-74. Conclusions: The new calculations of conversion coefficients for neutron irradiation in AP and RLAT irradiation geometries show a reduction in the values of effective dose by factors 7 (AP) and 6 (RLAT) with respect to the old data obtained with mathematical phantoms. The existence of tissues or anatomical regions with maximum absorbed doses, such as penis, lens of eyes, fascia (part of connective tissue), etc., organs/tissues that classic mathematical phantoms did not include because they were not considered for the study of stochastic effects, has been revealed. Absorbed doses due to photons, obtained following the same simulation methodology, are larger than those due to neutrons, reaching values 100 times larger as the primary beam is approached. However, for organs far from the treated volume, absorbed photon doses can be up to three times smaller than neutron ones. Calculations using voxel phantoms permitted to know the organ dose conversion coefficients per MU due to secondary neutrons in the complete anatomy of a patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that contralateral breast doses and LAR were comparable to WBRT, despite their added complexity. The smaller irradiated volume of the ABPI plan contributed to a halving of LAR for contralateral breast compared with the other plan types. Daily image guided radiotherapy (IGRT) for a left breast protocol using kilovoltage CBCT contributed <10% to LAR for the majority of organs, and did not exceed 22% of total organ dose. Conclusions: Phantom measurements and calculations of LAR from the BEIR VII models predict that complex breast radiotherapy techniques do not increase the theoretical risk of second cancer incidence for organs distant from the treated breast, or the contralateral breast where appropriate plan constraints are applied. Complex SIB treatments are predicted to increase the risk of second cancer incidence in the lungs compared to standard whole breast radiotherapy; this is outweighed by the threefold reduction in 5 yr local recurrence risk for patients of high risk of recurrence, and young age, from the use of radiotherapy. APBI may have a favorable impact on risk of second cancer in the contralateral breast and lung for older patients at low risk of recurrence. Intensive use of IGRTincreased the estimated values of LAR but these are dominated by the effect of the dose from the radiotherapy, and any increase in LAR from IGRT is much lower than the models' uncertainties.

60 APPLIED LIFE SCIENCES↗

A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model

Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: PENELOPE was first translated from FORTRAN to C++ and the result was confirmed to produce equivalent results to the original code. The C++ code was then adapted to CUDA in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gPENELOPE as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gPENELOPE. Ultimately, gPENELOPE was applied toward independent validation of patient doses calculated by MRIdian’s KMC. Results: An acceleration factor of 152 was achieved in comparison to the original single-thread FORTRAN implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: A Monte Carlo simulation platform was developed based on a GPU- accelerated version of PENELOPE. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-07: PENELOPE-Based GPU-Accelerated Dose Calculation System Applied to MRI-Guided Radiation Therapy

Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: We first translated PENELOPE from FORTRAN to C++ and validated that the translation produced equivalent results. Then we adapted the C++ code to CUDA in a workflow optimized for GPU architecture. We expanded upon the original code to include voxelized transport boosted by Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, we incorporated the vendor-provided MRIdian head model into the code. We performed a set of experimental measurements on MRIdian to examine the accuracy of both the head model and gPENELOPE, and then applied gPENELOPE toward independent validation of patient doses calculated by MRIdian’s KMC. Results: We achieve an average acceleration factor of 152 compared to the original single-thread FORTRAN implementation with the original accuracy preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen (1), mediastinum (1) and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: We developed a Monte Carlo simulation platform based on a GPU-accelerated version of PENELOPE. We validated that both the vendor provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

60 APPLIED LIFE SCIENCES↗