Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GEORGIA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Gene expression analysis of whole blood RNA from pigs infected with low and high pathogenic African swine fever viruses

African swine fever virus (ASFV) is a macrophage-tropic virus responsible for ASF, a transboundary disease that threatens swine production world-wide. Since there are no vaccines available to control ASF after an outbreak, obtaining an understanding of the virus-host interaction is important for developing new intervention strategies. In this study, a whole transcriptomic RNA-Seq method was used to characterize differentially expressed genes in pigs infected with a low pathogenic ASFV isolate, OUR T88/3 (OURT), or the highly pathogenic Georgia 2007/1 (GRG). After infection, pigs infected with OURT showed no or few clinical signs; whereas, GRG produced clinical signs consistent with acute ASF. RNA-Seq detected the expression of ASFV genes from the whole blood of the GRG, but not the OURT pigs, consistent with the pathotypes of these strains and the replication of GRG in circulating monocytes. Even though GRG and OURT possess different pathogenic properties, there was significant overlap in the most upregulated host genes. A small number of differentially expressed microRNAs were also detected in GRG and OURT pigs. These data confirm previous studies describing the response of macrophages and lymphocytes to ASFV infection, as well as reveal unique gene pathways upregulated in response to infection with GRG.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling Electric Vehicle Charging Load Using Origin-Destination Data

The accelerating adoption of electric vehicles (EVs) poses challenges to the power grid, necessitating precise representation of mobility patterns for effective infrastructure upgrades. Traditional simulation-based charging demand estimation faces limitations in generating trip chains reflective of actual travel patterns without complex network modeling. Hence, an innovative agent-based trip chain generation model is introduced to overcome these challenges. Drawing from the National Household Travel Survey (NHTS) and the NextGen NHTS origin-destination add-on data for Clarke County, Georgia, this study proposes a simulation method capturing both temporal and spatial mobility patterns without relying on extensive network topology data. The resulting trip chains predict EV charging load at the Census Block Group level, validated with a 1.03 correlation to actual trip counts, affirming their reflective accuracy. Two charging scenarios, residential-only and charging-everywhere, reveal distinct demand profiles. The charging-everywhere scenario aligns closely with the trip profile, while the residential-only scenario exhibits an afternoon peak slightly surpassing the former. This study contributes a data-driven charging demand estimation methodology, offering critical insights for grid resiliency planning amid the evolving landscape of EV adoption.

Pan, Melrose↗

Electron-ion dissociative recombination rate constants relevant to the Titan atmosphere and the Interstellar Medium

Following the arrival of Cassini at Titan in 2004, the Titan atmosphere has been shown to contain large complex polycyclic-aromatic hydrocarbons. Since Cassini has provided a great deal of data, there exists a need for kinetic rate data to help with modeling this atmosphere. One type of kinetic data needed is electron-ion dissociative recombination (e-IDR) rate constants. These data are not readily available for larger compounds, such as naphthalene, or oxygen containing compounds, such as 1,4 dioxane or furan. Here, the rate constants for naphthalene, 1,4 dioxane, and furan have been measured and their temperature dependencies are determined when possible, using the University of Georgia's Variable Temperature Flowing Afterglow. The rate constants are compared with those previously published for other compounds; these show trends which illustrate the effects which multi-rings and oxygen heteroatoms substitutions have upon e-IDR rate constants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NDE reliability and probability of detection (POD) evolution and paradigm shift

The subject of NDE Reliability and POD has gone through multiple phases since its humble beginning in the late 1960s. This was followed by several programs including the important one nicknamed “Have Cracks – Will Travel” or in short “Have Cracks” by Lockheed Georgia Company for US Air Force during 1974–1978. This and other studies ultimately led to a series of developments in the field of reliability and POD starting from the introduction of fracture mechanics and Damaged Tolerant Design (DTD) to statistical framework by Bernes and Hovey in 1981 for POD estimation to MIL-STD HDBK 1823 (1999) and 1823A (2009). During the last decade, various groups and researchers have further studied the reliability and POD using Model Assisted POD (MAPOD), Simulation Assisted POD (SAPOD), and applying Bayesian Statistics. All and each of these developments had one objective, i.e., improving accuracy of life prediction in components that to a large extent depends on the reliability and capability of NDE methods. Therefore, it is essential to have a reliable detection and sizing of large flaws in components. Currently, POD is used for studying reliability and capability of NDE methods, though POD data offers no absolute truth regarding NDE reliability, i.e., system capability, effects of flaw morphology, and quantifying the human factors. Furthermore, reliability and POD have been reported alike in meaning but POD is not NDE reliability. POD is a subset of the reliability that consists of six phases: 1) samples selection using DOE, 2) NDE equipment setup and calibration, 3) System Measurement Evaluation (SME) including Gage Repeatability and Reproducibility (Gage R and R) and Analysis Of Variance (ANOVA), 4) NDE system capability and electronic and physical saturation, 5) acquiring and fitting data to a model, and data analysis, and 6) POD estimation. This paper provides an overview of all major POD milestones for the last several decades and discuss rationale for using Integrated Computational Materials Engineering (ICME), MAPOD, SAPOD, and Bayesian statistics for studying controllable and non-controllable variables including human factors for estimating POD. Another objective is to list gaps between “hoped for” versus validated or fielded failed hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Images reveal that atmospheric particles can undergo liquid-liquid phase separations

A large fraction of submicron atmospheric particles contains both organic material and inorganic salts. As the relative humidity cycles in the atmosphere, these mixed particles can undergo a range of phase transitions, possibly including liquid-liquid phase separation. If liquid-liquid phase separation occurs, the gas-particle partitioning of atmospheric semi-volatile organic compounds, the scattering and absorption of solar radiation, and the uptake of reactive gas species on atmospheric particles will be affected, with important implications for climate predictions. The actual occurrence of these types of phase transitions within individual atmospheric particles has been considered uncertain, in large part because of the absence of observations for real-world samples. Here, using optical and fluorescence microscopy, we observe the coexistence of two non-crystalline phases in particles generated from real-world samples collected on multiple days in Atlanta, Georgia, and in particles generated in the laboratory using atmospheric conditions. These results reveal that atmospheric particles can undergo liquid-liquid phase separations. Using a box model, we show that liquid-liquid phase separation can result in increased concentrations of gas-phase NO3 and N2O5 in the Atlanta region, due to decreased particle uptake of N2O5.

54 ENVIRONMENTAL SCIENCES↗

Progress in the U.S./Japan PHENIX Project for the Technological Assessment of Plasma Facing Components for DEMO Reactors

The PHENIX Project is a 6-year U.S./Japan bilateral, multi-institutional collaboration program for the Technological Assessment of Plasma Facing Components for DEMO Reactors. The goal is to address the technical feasibility of helium-cooled divertor concepts using tungsten as the armor material in fusion power reactors. The project specifically attempts to (1) improve heat transfer modeling for helium-cooled divertor systems through experiments including steady-state and pulsed high-heat-load testing, (2) understand the thermomechanical properties of tungsten metals and alloys under divertor-relevant neutron irradiation conditions, and (3) determine the behavior of tritium in tungsten materials through high-flux plasma exposure experiments. The High Flux Isotope Reactor and the Plasma Arc Lamp facility at Oak Ridge National Laboratory, the Tritium Plasma Experiment facility at Idaho National Laboratory, and the helium loop at Georgia Institute of Technology are utilized for evaluation of the response to high heat loads and tritium interactions of irradiated and unirradiated materials and components. This paper provides an overview of the progress achieved during the first 3 years and discusses the plan for the remainder of the project.

Kato, Yutai↗

Thermal Hydraulics of Helium-Cooled Finger-Type Divertors at Higher Incident Heat Fluxes

Over the last decade, a number of studies at the Georgia Institute of Technology (GT) have evaluated the thermal hydraulics of the design of the helium-cooled modular divertor with multiple jets (HEMJ) originally developed at the Karlsruhe Institute of Technology. Using the GT helium loop, a test section of a single HEMJ finger heated by a radio-frequency (rf) induction heater was studied at near prototypical condition at pressures of ~10 MPa, maximum mass flow rates of 8 g/s, and maximum helium inlet temperatures Ti of 425°C. The area-averaged cooled surface temperature was estimated from embedded thermocouple measurements. This, together with the average incident heat flux q ‾ ′′ , was used to determine the average heat transfer coefficient and the corresponding Nusselt number N u ‾ over the cooled surface. The normalized pressure loss coefficient KL was determined from the pressure drop measured across the test section. The helium loop was modified last year by enclosing the test section and heater within an argon-filled stainless steel chamber to minimize oxidation of the tungsten-alloy test section. Initial results, when extrapolated to prototypical conditions, suggested that N u ‾ was about 20% higher than our previous results. However, the maximum heat flux for these results was less than 3 MW/m2 due to rf coupling with the steel chamber walls. The chamber was then recently upgraded to a glass–stainless steel enclosure with modified feedthroughs for the induction heater connections to minimize this coupling. With this upgrade, a maximum incident heat flux q ‾ ′′ = 8.1 MW/m 2 was achieved. This work presents experimental estimates and correlations for N u ‾ and K L at higher heat fluxes. These results provide greater confidence when estimating the maximum heat flux that can be accommodated by the HEMJ at fully prototypical conditions. Lastly, preliminary metrology results for the test section used to experimentally study the simplified flat design variant of the HEMJ are presented as part of an effort to resolve recently reported discrepancies between experimentally estimated and numerically simulated N u ‾ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Experimental Reversed Heat Flux Investigation of the Helium-Cooled Modular Divertor with Multiple Jets

The Georgia Institute of Technology group has performed studies to characterize the thermal hydraulics of a single “finger” module of the helium-cooled modular divertor with multiple jets (HEMJ) proposed for long-pulse magnetic fusion reactors in a helium (He) loop designed with maximum mass flow rate of 10 g/s. However, testing divertor modules at prototypical heat fluxes and temperatures remains an engineering challenge. A new larger helium loop with a maximum mass flow rate of 100 g/s, suitable for evaluating helium-cooled divertors with larger surface areas such as a nine-finger HEMJ module, is currently being constructed. This work presents an experimental validation of a numerical model exploring the applicability of the “reversed heat flux approach,” which cools (versus heats) the plasma-facing surface of the divertor module to evaluate the helium-side heat transfer coefficient (HTC). The approach is to be used for performance evaluation of single and multiple modules of HEMJ in existing and future large helium loops. A cooling facility for producing a jet of water with a maximum mass flow rate of 1.4 kg/s at a maximum pressure of 0.4 MPa and temperature of 295 K (Re = 2.2 × 10 5 ) is described. Numerical and experimental results are presented for the heat flux and average helium impingement surface temperature over a range of water flow rates (0.5 to 1.4 kg/s) for heat fluxes as high as 5 MW/m 2 . The numerical model suggests that the HTC of the water impingement surface is comparable to or greater than that of the helium impingement surface. For given helium and water temperatures, the heat flux values are generally limited by conduction across the outer shell. These initial studies provide guidance on extending this approach to estimating the thermal-hydraulic performance of larger divertor module designs while reducing the challenges associated with studying such designs in the normal heating configuration at their extremely high prototypical temperatures and incident heat fluxes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

Updated Thermofluid Performance of the Simplified Flat Variant of the HEMJ

Our group has recently developed and studied “finger”-type divertors that are a simplified version of the helium-cooled modular divertor with multiple jets (HEMJ) using coupled computational fluid dynamics and thermal stress simulations. Such a simplified geometry could reduce complexity and cost given the large number of fingers required to cover the total divertor target area. Previous experimental studies for this simplified flat design reported lower heat transfer coefficients and higher pressure drops than the HEMJ, contrary to numerical predictions. Subsequent measurements determined that the original test section had significant dimensional variations in the jet exit holes. A new test section was therefore manufactured and tested in the Georgia Tech (GT) helium loop. The experimental results presented here for this test section at maximum heat flux of 7.1 MW/m 2 are in good agreement with numerical predictions. Correlations developed from these experimental data are extrapolated to predict the maximum heat flux that can be accommodated by the flat design and the coolant pumping power requirements under prototypical conditions. Lastly, numerical simulations are used to estimate the sensitivity of the flat design to geometric variations typical of manufacturing tolerances and variations in the gap width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Comparison of Helium and sCO 2 as Coolants for Modular Finger-Type Divertors

Several studies at the Georgia Institute of Technology have evaluated the thermal and fluids performance of the helium-cooled modular divertor with multiple jets (HEMJ) over the past decade. This finger-type divertor was studied both experimentally at nearly prototypical conditions and numerically at fully prototypical operating conditions using experimentally validated simulations. Recently, supercritical carbon dioxide (sCO 2 ) has been studied as the primary coolant in power cycles and other applications in various systems, in part because CO 2 achieves the high densities typical of supercritical fluids at relatively low temperatures and pressures, with a critical point of (7.38 MPa, 31°C). This density makes it possible to realize very compact and efficient sCO 2 power cycles. The feasibility of sCO 2 as a coolant for plasma-facing components, specifically the divertor, was therefore evaluated as part of the Fusion Energy System Studies design study activities. This work compares the thermal-fluid performance of helium and sCO 2 in the HEMJ divertor geometry using numerical simulations at prototypical conditions: inlet temperatures T i = 600°C to 700°C, pressures p ≈ 10 MPa, and steady-state incident heat fluxes on the tile q″ < 17 MW/m 2 . The performance is quantified here as the maximum heat flux that can be accommodated by the plasma-facing tile, the pumping power fraction, defined as the ratio of the coolant pumping power to the incident thermal power, and the operating stress limits based on ASME pressure vessel criteria. As expected, helium requires lower mass flow rates and pumping power fractions within imposed maximum temperature limits for the HEMJ pressure boundary. However, it also appears that neither helium nor sCO 2 can remove 10 MW/m 2 of incident heat flux while meeting ASME pressure vessel criteria. Finally, the numerical modeling reveals that sCO 2 may remove slightly higher incident heat fluxes than helium due to the imposed stress limits due to the sCO 2 coolant resulting in smaller local temperature gradients, albeit at a considerably higher pumping power fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A convective wind resource model for Solar Vortex power generation

Climate change has increased the need for clean, nonpolluting energy sources to decrease dependence on fossil fuels. Alternative energy sources, mainly solar and horizontal wind, have been the primary focus for producing clean energy. New technologies are being developed, such as the Solar Vortex (SoV), which was developed at the Georgia Institute of Technology, and relies on a vertical wind resource to generate power. The National Renewable Energy Lab (NREL) has resource models representing solar and horizontal wind resources across the 48 United States. This research developed a vertical wind resource model that is comparable in resolution to NREL’s solar and horizontal wind resource models and uses the model for estimating power output for the SoV. This model complements NREL’s existing resource models and supports the deployment of an additional clean energy generation technology. The model was applied to Mesa, Arizona to find feasible sites for a small-scale vertical wind farm.

14 SOLAR ENERGY↗

Stock-Specific Size and Migration of Juvenile Coho Salmon in British Columbia and Southeast Alaska Waters

Abstract The variation at 17 microsatellites was analyzed for 5,270 juvenile Coho Salmon Oncorhynchus kisutch obtained from coastal British Columbia and Gulf of Alaska surveys during 1998–2012. A 270-population baseline was used to determine the individual identifications of the fish sampled, with individuals being identified to 22 stocks of origin. Columbia River and Washington juveniles were consistently larger than those from British Columbia and Alaska. During June, the larger individuals within a stock were observed in more northerly locations. There was a relationship between the timing of northward migration and juvenile body size, with larger individuals migrating earlier than smaller individuals from the same stocks. Stock composition was more diverse in the northern sampling regions than in those in southern British Columbia. There was only a modest change in stock composition between fall and winter samples in both the Strait of Georgia and west coast of Vancouver Island sampling regions, indicating that juvenile migration had largely been completed by the fall. There was a wide divergence among stocks in juvenile size and dispersion among sampling locations. Received December 9, 2015; accepted February 9, 2016

Beacham, Terry D.↗

Lack of long-term effect of coarse woody debris dam restoration on ecosystem functioning and water quality in Coastal Plain streams

Coarse woody debris (CWD) addition is a restoration technique that has been used to reduce effects of landscape disturbance on instream habitat. However, efficacy of this technique for improving ecosystem condition is not well established, in part because monitoring designed to evaluate long-term efficacy is rare. We assessed the effectiveness of CWD additions in disturbed Coastal Plain streams at Fort Benning Military Installation, Georgia, USA, 14 y after initial restoration. In October 2003, 4 disturbed streams received CWD additions (restored streams), and 4 streams were left as unrestored controls. Pre-restoration (2001–2003) and post-restoration (2003–2006) monitoring of nutrient uptake, stream metabolism, and water-quality variables revealed 1) minimal change in water-quality variables, 2) increased stream metabolism and nutrient-uptake rates immediately following restoration, and 3) decreased metabolism and uptake over the remainder of the 3-y post-restoration period. We returned to these streams in 2017 and 2018, measured the same variables, and found minimal long-term effects of restoration on water quality, nutrient uptake, and whole-stream metabolism indicators; however, streamwater pH decreased in all streams 14 y after restoration, and there was a weak treatment × period interaction, indicating that CWD additions may decrease pH in the long term. Further, we found few relationships between watershed disturbance and water-quality variables and ecosystem function metrics, although some relationships were apparent during certain seasons and years. Furthermore, our study is one of the few that have assessed the long-term effects of CWD additions, or any other stream-restoration technique, on ecosystem function. These long-term assessments may be necessary to determine if restorations are a good use of limited resources.

54 ENVIRONMENTAL SCIENCES↗

ELEVEN EXOPLANET HOST STAR ANGULAR DIAMETERS FROM THE CHARA ARRAY

We directly measured the angular diameters for 11 exoplanet host stars using Georgia State University's CHARA Array interferometer and calculated their linear radii and effective temperatures. The sample tends toward evolving or evolved stars and includes one dwarf, four subgiants, and six giants. We then estimated masses and ages for the stars using our effective temperatures combined with metallicity measurements from the literature.

99 GENERAL AND MISCELLANEOUS↗

ANGULAR DIAMETERS AND EFFECTIVE TEMPERATURES OF 25 K GIANT STARS FROM THE CHARA ARRAY

Using Georgia State University's Center for High Angular Resolution Astronomy Array interferometer, we measured angular diameters for 25 giant stars, six of which host exoplanets. The combination of these measurements and Hipparcos parallaxes produces physical linear radii for the sample. Except for two outliers, our values match angular diameters and physical radii estimated using photometric methods to within the associated errors with the advantage that our uncertainties are significantly lower. We also calculated the effective temperatures for the stars using the newly measured diameters. Our values do not match those derived from spectroscopic observations as well, perhaps due to the inherent properties of the methods used or because of a missing source of extinction in the stellar models that would affect the spectroscopic temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ANGULAR DIAMETER AND EFFECTIVE TEMPERATURE OF THE LITHIUM-RICH K GIANT HD 148293 FROM THE CHARA ARRAY

We measured the angular diameter of the lithium-rich K giant star HD 148293 using Georgia State University's Center for High Angular Resolution Astronomy Array interferometer. We used our measurement to calculate the star's effective temperature, which allowed us to place it on an H-R diagram to compare it with other Li-rich giants. Its placement supports the evidence presented by Charbonnel and Balachandran that it is undergoing a brief stage in its evolution where Li is being created.

25 ENERGY STORAGE↗

FUNDAMENTAL PARAMETERS OF THE EXOPLANET HOST K GIANT STAR {iota} DRACONIS FROM THE CHARA ARRAY

We measured the angular diameter of the exoplanet host star {iota} Dra with Georgia State University's Center for High Angular Resolution Astronomy Array interferometer and, using the star's parallax and photometry from the literature, calculated its physical radius and effective temperature. We then combined our results with stellar oscillation frequencies from Zechmeister et al. and orbital elements from Kane et al. to determine the masses for the star and exoplanet. Our value for the central star's mass is 1.82 {+-} 0.23 M{sub Sun }, which means the exoplanet's minimum mass is 12.6 {+-} 1.1 M{sub Jupiter}. Using our new effective temperature, we recalculated the habitable zone for the system, though it is well outside the star-planet separation.

79 ASTRONOMY AND ASTROPHYSICS↗