Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Variable frequency inverter for ac induction motors with torque, speed and braking control

A variable frequency inverter was designed for driving an ac induction motor which varies the frequency and voltage to the motor windings in response to varying torque requirements for the motor so that the applied voltage amplitude and frequency are of optimal value for any motor load and speed requirement. The slip frequency of the motor is caused to vary proportionally to the torque and feedback is provided so that the most efficient operating voltage is applied to the motor. Winding current surge is limited and a controlled negative slip causes motor braking and return of load energy to a dc power source.

Nola, F. J.↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CHEETAH: Compact High Efficiency Electrically Tunable Amplifier (Final Report)

The goal of this project was to develop a new type of optically triggered, high speed and high power switch for radiofrequency applications with potential to exceed current state-of-the-art power and bandwidth. This device operates under a new operation principle, where discrete packets of charge carriers are generated with defined size. These are then swept out of the device at high enough fields to prevent diffusion and expansion of these packets. Individual pulse widths are determined by the spatial extent of these packets and their drift velocity, which would enable control over both amplitude and frequency by control of the initial packet size, illumination intensity, and applied voltage. This effort demonstrated this new mode of operation, while uncovering a new regime of pulse compression using negative differential mobility (NDM) semiconductors such as GaAs, where the output electrical pulse is substantially shorter than the input optical pulse.

42 ENGINEERING↗

CHEETAH: Compact High Efficiency Electrically Tunable Amplifier (Abbreviated Final Report)

The goal of this project was to develop a new type of optically triggered, high speed and high power switch for radiofrequency applications with potential to exceed current state-of-the-art power and bandwidth. This device operates under a new operation principle, where discrete packets of charge carriers are generated with defined size. These are then swept out of the device at high enough fields to prevent diffusion and expansion of these packets. Individual pulse width are determined by the spatial extent of these packets and their drift velocity, which would enable control over both amplitude and frequency by control of the initial packet size, illumination intensity, and applied voltage. This effort demonstrated this new mode of operation, while uncovering a new regime of pulse compression using negative differential mobility (NDM) semiconductors such as GaAs, where the output electrical pulse is substantially shorter than the input optical pulse.

42 ENGINEERING↗

A spaceborne receiver for measuring electromagnetic field intensity

Description of a very accurately controlled receiver for monitoring the electromagnetic radiations in both existing and projected space communication bands. Based on analysis of the existing and projected space communication bands, 108 to 174 MHz, 240 to 478 MHz, and 1535 to 1665 MHz were covered. The receiver achieves accurate control via a digitally tuned synthesizer and a wide range of digital control including frequency band coverage and gain control selection. Digital memory was provided to store 16 separate digital command instructions which can be programmed via a command data link. The receiver provides for transmission to the ground of both a predetection signal and signals in digital format, which in turn, were provided by sampling and analog-to-digital conversions.

Reich, B. W.↗

The effects of localized damping on structural response

The effect of localized structural damping on the excitability of higher order normal modes of the large space telescope was investigated. A preprocessor computer program was developed to incorporate Voigt structural joint damping models in a NASTRAN finite-element dynamic model. A postprocessor computer program was developed to select critical modes for low-frequency attitude control problems and for higher frequency fine-stabilization problems. The mode selection is accomplished by ranking the flexible modes based on coefficients for rate gyro, position gyro, and optical sensors, and on image-plane motions due to sinusoidal or random power spectral density force and torque inputs.

Merchant, D. H.↗

Infrared detector responsivity measured simultaneously at multiple frequencies

The responsivity (the ratio of the output electrical signal to the incident radiation power) of an IR detector is measured at several frequencies simultaneously. A computer-controlled variable frequency chopper is used. Chopper modulation of a blackbody is square-wave-like, hence measurements can be taken not only at the fundamental frequency but also at the harmonics. The technique gives excellent agreement with the classical technique of measuring the fundamental response alone at a set of modulation frequencies. With a small enough aperture and a high enough chopper speed, agreement can be within five percent out to 31 times the fundamental frequency. The technique allows the rapid and automated acquisition of the frequency response of IR detectors, which may then be screened for responsivity, noise, and noise equivalent power.

Brasunas, John C.↗

An Experimental Investigation of the Hinge-moment Characteristics of a Constant-chord Control Surface Oscillating at High Frequency

The results of an experimental investigation of the hinge-moment characteristics of a constant-chord control surface oscillating at high frequency is presented. The control surface was mounted on an aspect-ratio-2 triangular wing. The aerodynamic restoring-moment coefficient and damping-moment coefficient were determined at a frequency of 260 cycles per second for a Mach number range of 0.6 to 0.8 and 1.3 to 1.9 at angles of attack of 5 degrees and 10 degrees. The test results showed linear theory to be a reliable guide to the prediction of the trend of the restoring-moment coefficient with Mach number for the supersonic speed range of the investigation but overestimated the magnitude of the coefficient. The experimental values of the damping-moment coefficient were, for the most part, more positive than those indicated by the theory and, for some conditions, could lead to instability of the control surface. Comparison of the results of this investigation with those of previous investigations at 0 and 50 cycles per second showed that frequency had little effect on the restoring-moment coefficient. The damping-moment coefficient was similarly insensitive to frequency at an oscillation amplitude of plus-or-minus 1.0 degrees but at an amplitude ofplus-or-minus 2.5 degrees the results showed a destabilizing shift with increasing frequency.

Reese, David E JR↗

Frequency Response Improvement in a Standalone Small Hydropower Plant Using Battery Storage

This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. In conclusion, simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.

13 HYDRO ENERGY↗

A wide-band fiber optic frequency distribution system employing thermally controlled phase compensation

An active wide-band fiber optic frequency distribution system employing a thermally controlled phase compensator to stabilize phase variations induced by environmental temperature changes is described. The distribution system utilizes bidirectional dual wavelength transmission to provide optical feedback of induced phase variations of 100 MHz signals propagating along the distribution cable. The phase compensation considered differs from earlier narrow-band phase compensation designs in that it uses a thermally controlled fiber delay coil rather than a VCO or phase modulation to compensate for induced phase variations. Two advantages of the wide-band system over earlier designs are (1) that it provides phase compensation for all transmitted frequencies, and (2) the compensation is applied after the optical interface rather than electronically ahead of it as in earlier schemes. Experimental results on the first prototype shows that the thermal stabilizer reduces phase variations and Allan deviation by a factor of forty over an equivalent uncompensated fiber optic distribution system.

Johnson, Dean↗

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

Frequency-Weighting Filter Selection, for H2 Control of Microgravity Isolation Systems: A Consideration of the "Implicit Frequency Weighting" Problem

Many space-science experiments need an active isolation system to provide them with the requisite microgravity environment. The isolation systems planned for use with the International Space Station (ISS) have been appropriately modeled using relative position, relative velocity, and acceleration states. In theory, frequency-weighting design filters can be applied to these state-space models, in order to develop optimal H2 or mixed-norm controllers with desired stability and performance characteristics. In practice, however, since there is a kinematic relationship among the various states, any frequency weighting applied to one state will implicitly weight other states. These implicit frequency-weighting effects must be considered, for intelligent frequency-weighting filter assignment. This paper suggests a rational approach to the assignment of frequency-weighting design filters, in the presence of the kinematic coupling among states that exists in the microgravity vibration isolation problem.

Hampton, Roy David↗

Frequency-Weighting Filter Selection for H2 Control of Microgravity Isolation Systems: A Consideration of the "Implicit Frequency Weighting" Problem

Many space-science experiments need an active isolation system to provide them with the requisite microgravity environment. The isolation system planned for use with the International Space Station (ISS) have been appropriately modeled using relative position, relative velocity, and acceleration states. In theory, frequency-weighting design filters can be applied to them state-space models, In order to develop optimal H2 or mixed-norm controllers with desired stability and performance characteristics. In practice. however, since there Is a kinematic relationship among the various states. any frequency weighting applied to one state will implicitly weight other states. These implicit frequency-weighting effects must be considered, for intelligent frequency-weighting filter assignment. This paper suggests a rational approach to the assignment of frequency-weighting design filters, in the presence of the kinematic coupling among states that exists in the microgravity vibration isolation problem.

Hampton, R. David↗

Resolved rate and torque control schemes for large scale space based kinematically redundant manipulators

Resolved rate control of kinematically redundant ground based manipulators is a challenging problem. The structural, actuator, and control loop frequency characteristics of industrial grade robots generally allow operation with resolved rate control; a rate command is achievable with good accuracy. However, space based manipulators are different, typically have less structural stiffness, more motor and joint friction, and lower control loop cycle frequencies. These undesirable characteristics present a considerable Point of Resolution (POR) control problem for space based, kinematically redundant manipulators for the following reason: a kinematically redundant manipulator requires an arbitrary constraint to solve for the joint rate commands. A space manipulator will not respond to joint rate commands because of these characteristics. A space based manipulator simulation, including free end rigid body dynamics, motor dynamics, motor striction/friction, gearbox backlash, joint striction/friction, and Space Station Remote Manipulator System type configuration parameters, is used to evaluate the performance of a documented resolved rate control law. Alternate schemes which include torque control are also evaluated.

Robert W Bailey↗