Large-eddy simulations of turbulent flow for grid-
The grid-to-rod fretting (GTRF) problem in pressur
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The grid-to-rod fretting (GTRF) problem in pressur
With the advancement of renewable energy, the processing and handling of biomass feedstocks has drawn enormous research interest. The key to economically viable and operationally reliable biomass handling processes involves a complete understanding of the flow behavior of different feedstocks as functions of the inherent critical material properties environmental conditions, and critical processing parameters. This review introduces the basic principles and methods in bulk solids flow and highlights recent efforts to understand the flow behavior of biomass feedstocks. The effects of inherent properties, environmental parameters, and handling equipment on the flow behavior of biomass feedstocks are presented. Particle size, shape, moisture, consolidation stress, temperature, storage time at rest, chemical treatment, and the material and geometry of the handling equipment all substantially influence biomass flowability. The limitations of current studies and the potential methods to overcome them are presented. Finally, an outlook for future research effort is provided, with proposed opportunities for improving the characterization of biomass flow.
A bead-based sandwich immunoassay for botulinum neurotoxin serotype A (BoNT/A) has been developed and demonstrated using a recombinant 50 kDa fragment (BoNT/A-HC-fragment) of the BoNT/A heavy chain (BoNT/A-HC) as a structurally valid simulant. Three different anti-BoNT/A antibodies were attached to three different fluorescent dye encoded flow cytometry beads for multiplexing. The assay was conducted in two formats: a manual microcentrifuge tube format and an automated fluidic system format. Flow cytometry detection was used for both formats. The fluidic system used a novel microbead-trapping flow cell to capture antibody-coupled beads with subsequent sequential perfusion of sample, wash, dye-labeled reporter antibody, and final wash solutions. After the reaction period, the beads were collected for analysis by flow cytometry. Sandwich assays performed on the fluidic system gave median fluorescence intensity signals on the flow cytometer that were 2-4 times higher than assays performed manually in the same amount of time. Limits of detection were estimated at 1 pM (~50 pg/mL for BoNT/A-HC-fragment) for the 15 minute fluidic assay.
Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.
Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.
These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.
Two-phase air-water flow characteristics are experimentally investigated in horizontal circular micro-channels. Test sections are made of fused silica. The experiments are conducted based on three different inner diameters of 0.53, 0.22 and 0.15 mm with the corresponding lengths of 320, 120 and 104 mm, respectively. The test runs are done at superficial velocities of gas and liquid ranging between 0.37-42.36 and 0.005-3.04 m/s, respectively. The flow visualisation is facilitated by systems mainly including stereozoom microscope and high-speed camera. The flow regime maps developed from the observed flow patterns are presented. The void fractions are determined based on image analysis. New correlation for two-phase frictional multiplier is also proposed for practical applications. (author)
A data-driven method was applied to Au+Au collisions at root S-NN = 200 GeV made with the STAR detector at RHIC to isolate pseudorapidity distance Delta eta-dependent and Delta eta-independent correlations by using two- and four-particle azimuthal cumulant measurements. We identified a Delta eta-independent component of the correlation, which is dominated by anisotropic flow and flow fluctuations. It was also found to be independent of. within the measured range of pseudorapidity vertical bar eta vertical bar < 1. In 20-30% central Au+Au collisions, the relative flow fluctuation was found to be 34% +/- 2%(stat.) +/- 3%(sys.) for particles with transverse momentum p(T) less than 2 GeV/c. The Delta eta-dependent part, attributed to nonflow correlations, is found to be 5% +/- 2%(sys.) relative to the flow of the measured second harmonic cumulant at vertical bar Delta eta vertical bar > 0.7. (C) 2015 The Authors. Published by Elsevier B.V.
We demonstrated a two-electron nonaqueous redox flow battery based on structurally tailored organic phenothiazine catholyte and anthraquinone anolyte materials, with doubled charge storage capacities and two voltage plateaus observed in electrochemical cell tests.
The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.
This is the paper we drafted based on CCSI Task 3 work on wetted area prediction with volume of fluids method.
Combustors in modern aerospace propulsion systems are highly optimized devices and further enhancements to their performance will require advanced predictive modeling techniques. The LES approach has potential to be such a technique, but demonstration of its true predictive capability remains a challenge. In this paper, a methodical study is performed to assess the impact of numerical error on the predictive capabilities of LES and to distinguish it from error arising from physical modeling. Four codes are employed to simulate the bluff body stabilized flame experiment of Volvo Flygmotor AB. The physical models (governing equations and sub-grid models) are kept identical between the codes so that the physical modeling error is the same. For the same reason, computational grids are also kept identical since the sub-grid models are grid dependent. Results indicate that all codes produce a very similar solution for the non-reacting flow in terms of large scale unsteady vortex shedding behavior, mean profiles and second order turbulence statistics, on a suitably refined grid. This solution is also very close to the experimentally observed behavior of the flow. In contrast, for the reacting case, solutions from the various codes exhibit significant differences when analyzed under the same metrics and with similar or even finer grid resolution than that used for the non-reacting case. These differences are large enough to change the macroscopic behavior of the flow, e.g. some codes predict symmetric vortex shedding while others predict asymmetric shedding and some codes show strong recirculation zones while others show stagnant regions behind the bluff body. It is also shown that none of the solutions truly predicts the experimentally observed flow. Given that the physical sub-grid models and computational grids are the same in all the simulations, the inconsistency between results points to a significant impact of numerical methods and, hence, numerical error. The need for mitigation of this impact is highlighted, along with the need for metrics detailing how LES should be applied to reacting flows. It is suggested that both of these issues should be the focus of future work.
Abstract Fluids with different densities often coexist in subsurface fractures and lead to variable‐density flows that control subsurface processes such as seawater intrusion, contaminant transport, and geologic carbon sequestration. In nature, fractures have dip angles relative to gravity, and density effects are maximized in vertical fractures. However, most studies on flow and transport through fractures are often limited to horizontal fractures. Here, we study the mixing and transport of variable‐density fluids in vertical fractures by combining three‐dimensional (3D) pore‐scale numerical simulations and visual laboratory experiments. Two miscible fluids with different densities are injected through two inlets at the bottom of a fracture and exit from an outlet at the top of the fracture. Laboratory experiments show the emergence of an unstable focused flow path, which we term a “runlet.” We successfully reproduce the unstable runlet using 3D numerical simulations and elucidate the underlying mechanisms triggering the runlet. Dimensionless number analysis shows that the runlet instability arises due to the Rayleigh‐Taylor instability (RTI), and flow topology analysis is applied to identify 3D vortices that are caused by the RTI. Even under laminar flow regimes, fluid inertia is shown to control the runlet instability by affecting the size and movement of vortices. Finally, we confirm the emergence of a runlet in rough‐walled fractures. Since a runlet dramatically affects fluid distribution, residence time, and mixing, the findings in this study have direct implications for the management of groundwater resources and subsurface applications.
With the introduction of higher levels of renewables and demand response programs, traditional deterministic power system tools fall short of expectations. Probabilistic load flow (PLF) takes into account the inconsistency or the unknown loads, and generation in the fundamental load flow analysis. This study proposes a PLF solution for both balanced and unbalanced, radial and weakly meshed networks without explicitly using the Y ‐bus matrix. It allows for discrete probability density functions as input variables without having to assume a predefined distribution. The nodal voltages and the power flows can be calculated independently from one another. The proposed method is applied to the IEEE 123 Node Test Feeder and the IEEE 13 Node Test Feeder in both its original radial configuration and a modified mesh configuration, including a load replaced with a wind turbine. The results are validated by comparison of the proposed method's solutions to those obtained using cumulants and Monte Carlo simulation. The proposed PLF method provides an accurate and practical way for finding the solution to stochastic problems occurring in power distribution systems allowing for real‐system data to be analysed.
Collisionless trapped ion modes (CTIMs) turbulence exhibits a rich variety of zonal flow physics. The coupling of CTIMs with shear flow driven by the Kelvin-Helmholtz (KH) instability has been investigated. The work explores the parametric excitation of zonal flow modified by wave-particle interactions leading to a new type of resonant low-frequency zonal flow. The KH-CTIM interaction on zonal flow growth and its feedback on turbulence is investigated using semi-Lagrangian gyrokinetic Vlasov simulations based on a Hamiltonian reduction technique, where both fast scales (cyclotron plus bounce motions) are gyro-averaged.
The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.
We extend the discussion of the 'Kerr/CFT correspondence' and its recent developments to the more general gauge/gravity correspondence in the full extremal black hole space-time of the bulk by using a technique of the holographic renormalization group (RG) flow. It is conjectured that the extremal black hole space-time is holographically dual to the chiral two-dimensional field theory. Our example is a typical four-dimensional Reissner-Nordstrom black hole, a system in which the M5-brane is wrapped on four cycles of Calabi-Yau threefold. In the five-dimensional supergravity viewpoint, this near horizon geometry is AdS{sub 3}xS{sup 2}, and three-dimensional gravity coupled to moduli fields is effectively obtained after a dimensional reduction on S{sup 2}. Constructing the Hamilton-Jacobi equation, we define the holographic RG flow from the three-dimensional gravity. The central charge of the Virasoro algebra is calculable from the conformal anomaly at the point where the beta function defined from the gravity side becomes zero. In general, we can also identify the c function of the dual two-dimensional field theory. We show that these flow equations are completely equivalent to not only BPS but also non-BPS attractor flow equations of the moduli fields. The attractor mechanism by which the values of the moduli fields are fixed at the event horizon of the extremal black hole can be understood equivalently to the fact that the RG flows are fixed at the critical points in the dual field theory.