Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Multilevel Analysis, Design, and Modeling of Coupling Advanced Nuclear Reactors and Thermal Energy Storage in an Integrated Energy System

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (A LWR), a high-temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state and transient-state operation with minimum disruption to the nuclear power cycle. This first part of the study presents steady-state models developed using Aspen HYSYS®, with the thermal energy bypass for NPP-TES coupling being varied at up to 50%. The various components were sized using the Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The TES-coupled A-NPP steady-state models and cost functions then provided a baseline for dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools. A stochastic optimization of the various energy storage systems coupled to the A-NPPs was then performed using the Risk Analysis Virtual Environment (RAVEN) and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON). The signal processing and synthetic history capabilities of RAVEN were used to account for the unpredictable behavior of electricity markets. An autoregressive moving average (ARMA) model was used to analyze price signals from the Pennsylvania-New Jersey-Maryland (PJM) market and were applied to the HERON analysis in order to optimize a system with the best economics. Transient modeling evaluation was then performed using Modelica models within the HYBRID repository, which was developed at INL for the Department of Energy Integrated Energy Systems program for the characterization of dynamic integrated system behavior and feedback. This includes evaluation of the TES-coupled A-LWR systems’ impact on physical and thermal system response during imposed system demands. Additional TES-coupled reactor types, coupling approaches, markets, and TES technologies will be evaluated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical Waveguide Solar Energy System for Lunar Materials Processing

This paper discusses results of our work on development of the Optical Waveguide (OW) Solar Energy System for Lunar Materials Processing. In the OW system as shown, solar radiation is collected by the concentrator which transfers the concentrated solar radiation to the OW transmission line consisting of low-loss optical fibers. The OW line transmits the solar radiation to the thermal reactor of the lunar materials processing plant. The feature of the OW system are: (1) Highly concentrated solar radiation (up to 104 suns) can be transmitted via flexible OW lines directly into the thermal reactor for materials processing: (2) Solar radiation intensity or spectra can be tailored to specific materials processing steps; (3) Provide solar energy to locations or inside of enclosures that would not otherwise have an access to solar energy; and (4) The system can be modularized and can be easily transported to and deployed at the lunar base.

Nakamura, T.↗

A Pattern-Recognition-Based Ensemble Data Imputation Framework for Sensors from Building Energy Systems

Building operation data are important for monitoring, analysis, modeling, and control of building energy systems. However, missing data is one of the major data quality issues, making data imputation techniques become increasingly important. There are two key research gaps for missing sensor data imputation in buildings: the lack of customized and automated imputation methodology, and the difficulty of the validation of data imputation methods. In this paper, a framework is developed to address these two gaps. First, a validation data generation module is developed based on pattern recognition to create a validation dataset to quantify the performance of data imputation methods. Second, a pool of data imputation methods is tested under the validation dataset to find an optimal single imputation method for each sensor, which is termed as an ensemble method. The method can reflect the specific mechanism and randomness of missing data from each sensor. The effectiveness of the framework is demonstrated by 18 sensors from a real campus building. The overall accuracy of data imputation for those sensors improves by 18.2% on average compared with the best single data imputation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.

Source record↗

A survey of manufacturers of solar thermal energy systems

Sixty-seven firms that had received funding for development of solar thermal energy systems (STES) were surveyed. The effect of the solar thermal technology systems program in accelerating (STES) were assessed. The 54 firms still developing STES were grouped into a production typology comparing the three major technologies with three basic functions. It was discovered that large and small firms were developing primarily central receiver systems, but also typically worked on more than one technology. Most medium-sized firms worked only on distributed systems. Federal support of STES was perceived as necessary to allow producers to take otherwise unacceptable risks. Approximately half of the respondents would drop out of STES if support were terminated, including a disproportionate number of medium-sized firms. A differentiated view of the technology, taking into account differing firm sizes and the various stages of technology development, was suggested for policy and planning purposes.

Levine, N.↗

The Clouds and the Earth's Radiant Energy System (CERES) Sensors and Preflight Calibration Plans

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft sensors are designed to measure broadband earth-reflected solar shortwave (0.3-5 microns) and earth-emitted longwave (5- > 100 microns) radiances at the top of the atmosphere as part of the Mission to Planet Earth program. The scanning thermistor bolometer sensors respond to radiances in the broadband shortwave (0.3-5 microns) and total-wave (0.3- > 100 microns) spectral regions, as well as to radiances in the narrowband water vapor window (8-12 microns) region. 'ne sensors are designed to operate for a minimum of 5 years aboard the NASA Tropical Rainfall Measuring Mission and Earth Observing System AM-1 spacecraft platforms that are scheduled for launches in 1997 and 1998, respectively. The flight sensors and the in-flight calibration systems will be calibrated in a vacuum ground facility using reference radiance sources, tied to the international temperature scale of 1990. The calibrations will be used to derive sensor gains, offsets, spectral responses, and point spread functions within and outside of the field of view. The shortwave, total-wave, and window ground calibration accuracy requirements (1 sigma) are +/-0.8, +/-0.6, and +/-0.3 W /sq m/sr, respectively, while the corresponding measurement precisions are +/-O.5% and +/-1.0% for the broadband longwave and shortwave radiances, respectively. The CERES sensors, in-flight calibration systems, and ground calibration instrumentation are described along with outlines of the preflight and in-flight calibration approaches.

Lee, Robert B., III↗

Solar energy system performance evaluation: Seasonal report for Elcam Tempe Arizona State University, Tempe, Arizona

The solar system, Elcam-Tempe, was designed by Elcam Incorporated, Santa Barbara, California, to supply commercial domestic hot water heating systems to the Agriculture Department residence at Arizona State University. The building is a single story residence located at the agriculture experiment farm of the Arizona State University. The energy system's four modes of operation are described. Electrical energy savings at the site was a net of 5.54 million Btu after the 0.17 million Btu of operating energy required to operate collector loop circulating pump were subtracted. The energy savings due to solar was less than the system's potential. On an average, twice as much hot water could have been used with significant solar energy contribution. The system corrosion and deposits caused by using dissimilar metals in the collector loop was the only problem noted with the Elcam-Tempe system.

Source record↗

Recent GRC Aerospace Technologies Applicable to Terrestrial Energy Systems

This paper is an overview of a wide range of recent aerospace technologies under development at the NASA Glenn Research Center, in collaboration with other NASA centers, government agencies, industry and academia. The focused areas are space solar power, advanced power management and distribution systems, Stirling cycle conversion systems, fuel cells, advanced thin film photovoltaics and batteries, and combustion technologies. The aerospace-related objectives of the technologies are generation of space power, development of cost-effective and reliable, high performance power systems, cryogenic applications, energy storage, and reduction in gas-turbine emissions, with attendant clean jet engines. The terrestrial energy applications of the technologies include augmentation of bulk power in ground power distribution systems, and generation of residential, commercial and remote power, as well as promotion of pollution-free environment via reduction in combustion emissions.

Kankam, David↗

Solar energy system performance evaluation. Seasonal report for Colt Pueblo, Pueblo, Colorado

The Colt-Pueblo solar energy system, designed to provide space heating and hot water preheating, is described and its operational performance for a 12 month period from February 1979 through January 1980 is evaluated. The space heating subsystem met 31 percent of the measured space heating load which was close to the expected 34 percent solar fraction. Although the hot water solar fraction was 79 percent, the overall energy saving capability was reduced because of the low hot water demand. The measured heating subsystem performance would have improved considerably if the uncontrolled losses primarily from transport piping could have been reduced to an inconsequential level. Fossil energy savings of 70.31 million BTUs are estimated.

Source record↗

Incident Energy Systems Model: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day.

14 SOLAR ENERGY↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Site selection feasibility for a solar energy system on the Fairbanks Federal Building

A feasibility study was performed for the installation of a solar energy system on the Federal Building in Fairbanks, Alaska, a multifloor office building with an enclosed parking garge. The study consisted of determining the collectable solar energy at the Fairbanks site on a monthly basis and comparing this to the monthly building heating load. Potential conventional fuel savings were calculated on a monthly basis and the overall economics of the solar system applications were considered. Possible solar system design considerations, collector and other system installation details, interface of the solar system with the conventional HVAC systems, and possible control modes were all addressed. Conclusions, recommendations and study details are presented.

Source record↗

Quality Guidelines for Energy System Studies: Process Modeling Design Parameters

The National Energy Technology Laboratory (NETL) conducts systems analysis studies that require a large number of inputs, from ambient conditions to parameters for Aspen Plus ® (Aspen) process blocks. The sheer number of assumptions required makes it impractical to document all of them in each issued report. The purpose of the Quality Guidelines for Energy System Studies (QGESS) is to document the assumptions most commonly used in system analysis studies and the basis for those assumptions. In order to develop the systems analysis models presented in various NETL reports, significant vendor data have been obtained, and these data enhance the model outputs. Much of the vendor data obtained are considered proprietary and not suitable for public release or attribution to a specific vendor. As such, several sub-systems common in NETL reports and their process parameter data are not reported in this document to protect proprietary vendor information. The values and ranges of values presented in this report represent assumptions that have been made in previous studies.

97 MATHEMATICS AND COMPUTING↗

Preliminary neutronic and thermal analysis of Inertial Fusion Energy systems with a focus on thick liquid wall concepts

This paper provides an assessment of the neutronic behavior of Inertial Fusion Energy systems using the Serpent 2 Monte Carlo code. The study explores different types of reactor concepts, including dry-wall and thick liquid wall systems. In particular, it characterizes the tritium breeding and energy multiplication performance, as well as the effect of long-term irradiation on structural materials. For this purpose, the displacement per atom (DPA) and the gas production rate in structural materials are calculated. A simplified geometry with varying geometrical parameters is used as a representation for the different kinds of devices. Additionally, the case of the HYLIFE-II concept is used to assess modeling inaccuracies arising from certain approximations. A comparison between the simplified geometry and a realistic one is performed, thanks to Serpent’s capability to run transport calculations on unstructured meshes. The study then addresses the impact of these discrepancies on the temperature distribution in the first wall using the GeN-Foam code for conjugate heat transfer analysis. The results highlight the necessity to consider the heterogeneous nature of the liquid wall, as simplified models tend to underestimate radiation damage metrics and heat loads.

Conjugate heat transfer↗

Analyses of On-orbit Determinations of the Clouds and the Earth Radiant Energy System (CERES) Thermistor Bolometer Sensor Zero-radiance Effects

The Clouds and Earth's Radiant Energy System (CERES) missions were designed to measure broadband earth-reflected shortwave solar (0.3 micrometers to less than 5.0 micrometers) and earth-emitted longwave (5.0 micrometers to greater than 100 micrometers) radiances as well as earth-emitted narrow-band radiances in the water vapor window region between 8 micrometers and 12 micrometers. However, the CERES scanning thermistor bolometer sensor zero-radiance offsets were found to vary as much as 1.0 Wm (exp -2) sr (exp -1) with the scan angle measurement geometry due to gravitational forces and systematic electronic noise. To minimize the gravitational effects, the Tropical Rainfall Measuring Mission (TRMM) Spacecraft CERES sensors' offsets were derived on-orbit as functions of scan elevation and azimuth angles from the January 7-8, 1998 radiometric observations of deep cold space, representative of a 3 K blackbody. In this paper, the TRMM/CERES six orbit data base of on-orbit derived offsets is presented and analyzed to define the sampling requirements for the CERES sensors located on the Earth Science Enterprise (ESE) Terra Spacecraft and on the Earth Observing System (EOS) Afternoon (PM-1) Spacecraft, scheduled for launches in 1999 and 2000, respectively. Analyses of the TRMM/CERES shortwave sensor earth radiance measurements indicate that offsets can be determined on-orbit at the plus or minus 0.02 Wm (exp -2) sr (exp -1) precision level. Offset measuring techniques and sampling requirements are discussed for the TRMM and ESE missions. Ground, pre-launch Terra CERES cross-track scan offsets are presented and described which were measured as a function of scan angle.

Lee, Robert B., III↗

Angular Distribution Models for Top-of-Atmosphere Radiative Flux Estimation from the Clouds and the Earth's Radiant Energy System Instrument on the Terra Satellite: Methodology - Part 1

The Clouds and Earth's Radiant Energy System (CERES) provides coincident global cloud and aerosol properties together with reflected solar, emitted terrestrial longwave and infrared window radiative fluxes. These data are needed to improve our understanding and modeling of the interaction between clouds, aerosols and radiation at the top of the atmosphere, surface, and within the atmosphere. This paper describes the approach used to estimate top-of-atmosphere (TOA) radiative fluxes from instantaneous CERES radiance measurements on the Terra satellite. A key component involves the development of empirical angular distribution models (ADMs) that account for the angular dependence of Earth's radiation field at the TOA. The CERES Terra ADMs are developed using 24 months of CERES radiances, coincident cloud and aerosol retrievals from the Moderate Resolution Imaging Spectroradiometer (MODIS), and meteorological parameters from the Global Modeling and Assimilation Office (GMA0) s Goddard Earth Observing System DAS (GEOS-DAS V4.0.3) product. Scene information for the ADMs is from MODIS retrievals and GEOS-DAS V4.0.3 properties over ocean, land, desert and snow, for both clear and cloudy conditions. Because the CERES Terra ADMs are global, and far more CERES data is available on Terra than was available from CERES on the Tropical Rainfall Measuring Mission (TRMM), the methodology used to define CERES Terra ADMs is different in many respects from that used to develop CERES TRMM ADMs, particularly over snow/sea-ice, under cloudy conditions, and for clear scenes over land and desert.

Loeb, N. G.↗

Clouds and the Earth's Radiant Energy System (CERES) Data Products for Climate Research

NASA's Clouds and the Earth's Radiant Energy System (CERES) project integrates CERES, Moderate Resolution Imaging Spectroradiometer (MODIS), and geostationary satellite observations to provide top-of-atmosphere (TOA) irradiances derived from broadband radiance observations by CERES instruments. It also uses snow cover and sea ice extent retrieved from microwave instruments as well as thermodynamic variables from reanalysis. In addition, these variables are used for surface and atmospheric irradiance computations. The CERES project provides TOA, surface, and atmospheric irradiances in various spatial and temporal resolutions. These data sets are for climate research and evaluation of climate models. Long-term observations are required to understand how the Earth system responds to radiative forcing. A simple model is used to estimate the time to detect trends in TOA reflected shortwave and emitted longwave irradiances.

Kato, Seiji↗

An overview of the Goldstone Energy Systems study

A systems planning methodology was developed for analyzing and synthesizing Deep Space Network (DSN) energy systems. The resultant product, the Deep Space Network Planning and Analysis Methodology supports DSN energy planning evaluations. It addresses a broad spectrum of tradeoff and dispatching scenarios. It evaluates a variety of energy generation configurations and also includes a capability to evaluate conservation measures.

Rosenberg, L. S.↗