Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code

India is experiencing unprecedented construction boom. The country doubled its floorspace between 2001 and 2005 and is expected to add 35 billion m 2 of new buildings by 2050. Buildings account for 35% of total final energy consumption in India today, and building energy use is growing at 8% annually. Studies have shown that carbon policies will have little effect on reducing building energy demand. Chaturvedi et al. predicted that, if there is no specific sectoral policies to curb building energy use, final energy demand of the Indian building sector will grow over five times by the end of this century, driven by rapid income and population growth. The growing energy demand in buildings is accompanied by a transition from traditional biomass to commercial fuels, particularly an increase in electricity use. This also leads to a rapid increase in carbon emissions and aggravates power shortage in India. Growth in building energy use poses challenges to the Indian government.

Code Compliance Evaluation↗

ACCELERATING HIGH-ENERGY PULSAR RADIATION CODES

Curvature radiation (CR) is believed to be a dominant mechanism for creating gamma-ray emission from pulsars and is emitted by relativistic particles that are constrained to move along curved magnetic field lines. Additionally, synchrotron radiation (SR) is expected to be radiated by both relativistic primaries (involving cyclotron resonant absorption of radio photons and re-emission of SR photons), or secondary electron-positron pairs (created by magnetic or photon-photon pair production processes involving CR gamma rays in the pulsar magnetosphere). When calculating these high-energy spectra, especially in the context of pulsar population studies where several millions of CR and SR spectra have to be generated, it is profitable to consider approximations that would save computational time without sacrificing too much accuracy. This paper focuses on one such approximation technique, and we show that one may gain significantly in computational speed while preserving the accuracy of the spectral results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A collision history-based approach to Sensitivity/Perturbation calculations in the continuous energy Monte Carlo code SERPENT

In this work, the implementation of a collision history-based approach to sensitivity/perturbation calculations in the Monte Carlo code SERPENT is discussed. The proposed methods allow the calculation of the eects of nuclear data perturbation on several response functions: the eective multiplication factor, reaction rate ratios and bilinear ratios (e.g., eective kinetics parameters). SERPENT results are compared to ERANOS and TSUNAMI Generalized Perturbation Theory calculations for two fast metallic systems and for a PWR pin-cell benchmark. New methods for the calculation of sensitivities to angular scattering distributions are also presented, which adopts fully continuous (in energy and angle) Monte Carlo estimators.

97 MATHEMATICS AND COMPUTING↗

National Cost-Effectiveness of the Residential Provisions of the 2024 IECC

This analysis focuses on single-family and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). The IECC is developed by the International Code Council (ICC) on a 3-year cycle through a public development and consensus process. While proponents of code changes often include the energy and cost-effectiveness criteria for their respective code change, the IECC process does not include an energy or cost-effectiveness analysis of the entire edition of the code. PNNL evaluated the cost effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2024 edition of the IECC, hereafter referred as the 2024 IECC, compared to those in the prior edition, the 2021 IECC. The simulated performance path and the Energy Rating Index (ERI) path (introduced in the 2015 IECC) are not considered in this analysis due to the wide variation in building construction characteristics that are allowed.

2024 IECC↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Whole core analysis of OECD/NEA TVA-WB1 benchmark exercise 1 using continuous-energy Monte Carlo code MVP with JENDL-4.0u and ENDF/B-VII.0

The TVA WB1 benchmark problem was precisely modeled in accordance with the geometry and material specifications, and benchmark exercise 1 was solved with the MVP code and the nuclear data libraries based on JENDL-4.0u (JENDL-4.0 updated file) and ENDF/B-VII.0. The criticality, the control rod bank worth, the isothermal temperature coefficient (ITC), the integral rod worth of bank D, and differential soluble boron worth (DBW) were obtained. The criticality and the control rod bank worth were compared with the measured data and published calculation results with other codes, Serpent and KENO. The criticality and the control rod bank worth calculated by MVP and the libraries agree with the measured and the published calculation results within the criteria specified in the ANSI/ANS standard. From these results, the calculation model for the MVP and the libraries was verified. The other parameters such as ITC, the integral rod worth, and DBW were also compared between JENDL-4.0u and ENDF/B-VII.0. The comparison of the results shows JENDL-4.0u and ENDF/B-VII.0 give comparable results within the standard deviation, the difference between libraries is small. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SimProp: a simulation code for ultra high energy cosmic ray propagation

A new Monte Carlo simulation code for the propagation of Ultra High Energy Cosmic Rays is presented. The results of this simulation scheme are tested by comparison with results of another Monte Carlo computation as well as with the results obtained by directly solving the kinetic equation for the propagation of Ultra High Energy Cosmic Rays. A short comparison with the latest flux published by the Pierre Auger collaboration is also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Residential Heat Recovery Ventilation

Heat recovery ventilators (HRVs) save energy by recovering heat that would otherwise be exhausted as part of energy code-mandated mechanical ventilation systems. Residential HRVs can be life cycle cost effective depending on equipment/installation costs and the severity of the climate. This brief evaluates HRV cost effectiveness in the context of building energy codes to identify the climate zones in which a code might reasonably require residential HRVs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preparing an Incompressible-Flow Fluid Dynamics Code for Exascale-Class Wind Energy Simulations

The U.S. Department of Energy has identified exascale-class wind farm simulation as critical to wind energy scientific discovery. A primary objective of the ExaWind project is to build high-performance, predictive computational fluid dynamics (CFD) tools that satisfy these modeling needs. GPU accelerators will serve as the computational thoroughbreds of next-generation, exascale-class supercomputers. Here, we report on our efforts in preparing the ExaWind unstructured mesh solver, Nalu-Wind, for exascale-class machines. For computing at this scale, a simple port of the incompressible-flow algorithms to GPUs is insufficient. To achieve high performance, one needs novel algorithms that are application aware, memory efficient, and optimized for the latest-generation GPU devices. The result of our efforts are unstructured-mesh simulations of wind turbines that can effectively leverage thousands of GPUs. In particular, we demonstrate a first-of-its-kind, incompressible-flow simulation using Algebraic Multigrid solvers that strong scales to more than 4000 GPUs on the Summit supercomputer.

algebraic multigrid↗

Energy and Energy Cost Savings Analysis of the IECC for Commercial Buildings

The purpose of this analysis is to assess the relative energy and energy cost performance of commercial buildings designed to meet the requirements found in the commercial energy efficiency provisions of the International Energy Conservation Code (IECC). Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. As many states have historically adopted the IECC for both residential and commercial buildings, PNNL has evaluated the impacts of the commercial provisions of the 2006, 2009, and 2012 editions of the IECC. PNNL also compared energy performance with corresponding editions of ANSI/ASHRAE/IES Standard 90.1 to help states and local jurisdictions make informed decisions regarding model code adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Storage System Safety Documenting and Validating Compliance with Codes and Standards

Energy, environmental, and economic challenges are spurring more widespread consideration and use of energy storage systems (ESSs), which in turn are driving increased development of new ways to store energy electrochemically, mechanically, and thermally. These new methods necessitate an increased focus on ensuring that public health, safety, and welfare are not adversely affected—something that has been addressed for many years through codes, standards, and regulations (CSR5)1. CSRs provide requirements that establish a basis for determining if an ESS is safe, whether electrochemical, mechanical, or thermal and regardless of the range of ESS applications, energy capacities, physical sizes, location, or number installed at any given site. The key to achieving desired safety goals, as memorialized through CSRs, is through documenting and validating compliance with applicable CSRs. The process of documenting and validating compliance, which is a key component to the initial approval as well as continuing acceptance of an ESS installation, is generally called conformity assessment.

25 ENERGY STORAGE↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗