Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Dynamic Contrast-Enhanced MRI in Head-and-Neck Cancer: The Impact of Region of Interest Selection on the Intra- and Interpatient Variability of Pharmacokinetic Parameters

Purpose: Dynamic contrast-enhanced (DCE) MRI-extracted parameters measure tumor microvascular physiology and are usually calculated from an intratumor region of interest (ROI). Optimal ROI delineation is not established. The valid clinical use of DCE-MRI requires that the variation for any given parameter measured within a tumor be less than that observed between tumors in different patients. This work evaluates the impact of tumor ROI selection on the assessment of intra- and interpatient variability. Method and Materials: Head and neck cancer patients received initial targeted therapy (TT) treatment with erlotinib and/or bevacizumab, followed by radiotherapy and concurrent cisplatin with synchronous TT. DCE-MRI data from Baseline and the end of the TT regimen (Lead-In) were analyzed to generate the vascular transfer function (K{sup trans}), the extracellular volume fraction (v{sub e}), and the initial area under the concentration time curve (iAUC{sub 1min}). Four ROI sampling strategies were used: whole tumor or lymph node (Whole), the slice containing the most enhancing voxels (SliceMax), three slices centered in SliceMax (Partial), and the 5% most enhancing contiguous voxels within SliceMax (95Max). The average coefficient of variation (aCV) was calculated to establish intrapatient variability among ROI sets and interpatient variability for each ROI type. The average ratio between each intrapatient CV and the interpatient CV was calculated (aRCV). Results: Baseline primary/nodes aRCVs for different ROIs not including 95Max were, for all three MR parameters, in the range of 0.14-0.24, with Lead-In values between 0.09 and 0.2, meaning a low intrapatient vs. interpatient variation. For 95Max, intrapatient CVs approximated interpatient CVs, meaning similar data dispersion and higher aRCVs (0.6-1.27 for baseline) and 0.54-0.95 for Lead-In. Conclusion: Distinction between different patient's primary tumors and/or nodes cannot be made using 95Max ROIs. The other three strategies are viable and equivalent for using DCE-MRI to measure head and neck cancer physiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging

Transmission geometry laser ablation directly into a formed liquid microjunction of a continuous flow liquid microjunction surface sampling probe/electrospray ionization emitter was utilized for molecular and elemental detection and mass spectrometry imaging. The ability to efficiently capture and ionize ablated material was demonstrated by the detection of various small soluble n-mers of polyaniline and silver ion solvent clusters formed from laser ablation of electropolymerized polyaniline and silver thin films, respectively. In addition, analysis of surfaces that contain soluble components was accomplished by coating or laminating the sample with an insoluble film to enable liquid junction formation without directly extracting material from the surface. The ability to perform mass spectrometry imaging at a spatial resolution of about 50 m was illustrated by using laminated inked patterns on a microscope slide. In general, these data demonstrate at least an order of magnitude signal enhancement compared to the non-contact, laser ablation droplet capture-based surface sampling/ionization approaches that have been previously presented.

electrospray ionization (ESI)↗

Online supercritical fluid extraction mass spectrometry (SFE-LC-FTMS) for sensitive characterization of soil organic matter

We report a novel technical approach for subcritical fluid extraction (SFE) for organic matter characterization in complex matrices such as soil. The custom platform combines on-line SFE with micro-solid phase extraction, nano liquid chromatography (LC), electrospray ionization and Fourier transform mass spectrometry (SFE-LC-FTMS). We demonstrated the utility of SFE-LC-FTMS, including results from both Orbitrap and FTICR MS, for analysis of complex mixtures of organic compounds in a solid matrix by characterizing soil organic matter in peat, a high-carbon soil. For example, in a single experiment, >6000 molecular formulas can be assigned based upon FTICR MS data from 1–50 μL of soil samples (roughly 1–50 mg of soil, dependent on soil density), nearly twice that typically obtained from direct infusion liquid solvent extraction (LSE) from an order of magnitude larger volume of the same soil. The detected species consisted predominately of lipid-like, lignin-like and protein-like compounds, based on their O/C and H/C ratios, with predominantly CHO and CHONP molecular compositions. These results clearly demonstrate that SFE has the potential to effectively extract a variety of molecular species and could become an important member of a suite of extraction methods for studying SOM and other natural organic matter. This is especially true when comprehensive coverage, minimal sample volumes, and high sensitivity are required, or when the presence of organic solvent residue in residual soil is problematic. Lastly, the SFE based extraction protocol could potentially enable spatially resolved characterization of organic matter in soil with a resolution of ~1 mm3 to facilitate studies probing the spatial heterogeneity of soil.

54 ENVIRONMENTAL SCIENCES↗

NREL Leads Energy Systems Integration, Continuum Magazine: Issue 4 (Book)

Continuum Magazine showcases NREL's latest and most impactful clean energy innovations. This issue, 'NREL Leads Energy Systems Integration' explores the discipline of energy systems integration, in particular the role of the laboratory's new, one-of-a-kind Energy System Integration Facility. NREL scientists, engineers, and analysts deeply understand the fundamental science and technologies underpinning major energy producing and consuming systems, as well as the transmission infrastructure and communications and data networks required to integrate energy systems at all scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inverter Load Rejection Over-Voltage Testing: SolarCity CRADA Task 1a Final Report

Various interconnection challenges exist when connecting distributed PV into the electrical distribution grid in terms of safety, reliability, and stability of electric power systems. One of the urgent areas for additional research - as identified by inverter manufacturers, installers, and utilities - is the potential for transient over-voltage from PV inverters. In one stage of a cooperative tests were repeated a total of seven times. The maximum over-voltage measured in any test did not exceed 200% of nominal, and typical over-voltage levels were significantly lower. The total voltage duration and the maximum continuous time above each threshold are presented here, as well as the time to disconnect for each test. Finally, we present a brief investigation into the effect of DC input voltage as well as a series of no-load tests. This report describes testing conducted at NREL to determine the duration and magnitude of transient over-voltages created by several commercial PV inverters during load-rejection conditions. For this work, a test plan that is currently under development by the Forum on Inverter Grid Integration Issues (FIGII) has been implemented in a custom test setup at NREL. Through a cooperative research and development agreement, NREL is working with SolarCity to address two specific types of transient overvoltage: load rejection overvoltage (LRO) and ground fault overvoltage (GFO). Additional partners in this effort include the Hawaiian Electric Companies, Northern Plains Power Technologies, and the Electric Power Research Institute.

14 SOLAR ENERGY↗

Comparison of venous and pooled capillary hemoglobin levels for the detection of anemia among adolescent girls

Introduction: Blood source is a known preanalytical factor affecting hemoglobin (Hb) concentrations, and there is evidence that capillary and venous blood may yield disparate Hb levels and anemia prevalence. However, data from adolescents are scarce. Objective: To compare Hb and anemia prevalence measured by venous and individual pooled capillary blood among a sample of girls aged 10–19 years from 232 schools in four regions of Ghana in 2022. Methods: Among girls who had venous blood draws, a random subsample was selected for capillary blood. Hb was measured using HemoCue® Hb-301. We used Lin’s concordance correlation coefficient (CCC) to quantify the strength of the bivariate relationship between venous and capillary Hb and a paired t-test for difference in means. We used McNemar’s test for discordance in anemia cases by blood source and weighted Kappa to quantify agreement by anemia severity. A multivariate generalized estimating equation was used to quantify adjusted population anemia prevalence and assess the association between blood source and predicted anemia risk. Results: We found strong concordance between Hb measures (CCC = 0.86). The difference between mean venous Hb (12.8 g/dL, ± 1.1) and capillary Hb (12.9 g/dL, ± 1.2) was not significant (p = 0.26). Crude anemia prevalence by venous and capillary blood was 20.6% and 19.5%, respectively. Adjusted population anemia prevalence was 23.5% for venous blood and 22.5% for capillary ( = 0.45). Blood source was not associated with predicted anemia risk (risk ratio: 0.99, 95% CI: 0.96, 1.02). Discordance in anemia cases by blood source was not significant (McNemar p = 0.46). Weighted Kappa demonstrated moderate agreement by severity (k =0.67). Among those with anemia by either blood source (n = 111), 59% were identified by both sources. Conclusion: In Ghanaian adolescent girls, there was no difference in mean Hb, anemia prevalence, or predicted anemia risk by blood source. However, only 59% of girls with anemia by either blood source were identified as having anemia by both sources. These findings suggest that pooled capillary blood may be useful for estimating Hb and anemia at the population level, but that caution is needed when interpreting individual-level data.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmaps of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.

drug metabolism↗

Trade Study of DEM Software

Review of Open-source Discrete Element Method Softwares: Three open-source solutions have been investigated for integration into OceanWATERS: Yade, EsysParticle, and ProjectChrono.

DEM↗

Idaho Wildfires II: Assessing the Relationship Between Drought Indicators and Wildfire Risk to Enhance Hazard Modeling and Inform Mitigation Planning

The western United States has experienced twenty years of increased and prolonged drought which have exacerbated wildfire hazards. These jeopardize population centers through increased risks to ecosystem services, local economies, and livelihoods. The Idaho Office of Emergency Management, Water Resources, and Department of Lands are seeking methods to dynamically monitor these conditions and update models that inform hazard mitigation planning and resource allocation. Towards this, these agencies partnered with NASA DEVELOP to produce drought-enhanced wildfire hazard models. Part of a two-term project, the two teams revised the state’s static wildfire hazard model with refined data layers and remotely-sensed data to reflect dynamic ecosystem responses to drought conditions and wildfire potential. Our team distinguished between rangeland and forestland ecosystems, and investigated relationships between drought metrics and vegetation condition using TerrSet Earth Trends Modeler. This analysis determined that total precipitation at a 5-month lag interval (r 2 = 0.72) along with the Evaporative Stress Index (r 2 = 0.69); and precipitation at a 5-month interval (r 2 = 0.42) were important drivers in rangeland and forestland, respectively. These driver variables were incorporated into a temporally dynamic wildfire hazard map. Our team used linear regression to correlate hazard ratings with wildfire frequency. For the year 2020, neither the enhanced hazard model (p < 0.10, r 2 = 0.01) nor the state’s static model (p < 0.05, r 2 = 0.03) were strongly correlated with actual wildfire frequency as they expressed an inverse relationship between wildfire hazard and frequency. This suggests wildfire occurrence is complex and not necessarily driven by the variables used.

Wildfire↗

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Humidity↗