Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR DETECTING CODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

New dark matter analysis of milky way dwarf satellite galaxies with madhatv2

We obtain bounds on dark matter annihilation using 14 years of publicly available Fermi-LAT data from a set of 54 dwarf spheroidal galaxies, using spectral information from 16 energy bins. We perform this analysis using our updated and publicly available code , which can be used to test a variety of models for dark matter particle physics and astrophysics in an accessible manner. In particular, we note that including Carina III in the analysis strengthens constraints on s -wave annihilation into two-body Standard Model final states by a factor of ∼ 3 but broadens the error on the constraint due to the large uncertainty of its J -factor. Our findings illustrate the importance of verifying if Carina III is in fact a dwarf spheroidal galaxy and measuring more precisely its J -factor. More generally, they highlight the significance of forthcoming discoveries of nearby ultrafaint dwarfs for dark matter indirect detection. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

VirSorter2: a multi-classifier, expert-guided approach to detect diverse DNA and RNA viruses

Abstract Background Viruses are a significant player in many biosphere and human ecosystems, but most signals remain “hidden” in metagenomic/metatranscriptomic sequence datasets due to the lack of universal gene markers, database representatives, and insufficiently advanced identification tools. Results Here, we introduce VirSorter2, a DNA and RNA virus identification tool that leverages genome-informed database advances across a collection of customized automatic classifiers to improve the accuracy and range of virus sequence detection. When benchmarked against genomes from both isolated and uncultivated viruses, VirSorter2 uniquely performed consistently with high accuracy (F1-score > 0.8) across viral diversity, while all other tools under-detected viruses outside of the group most represented in reference databases (i.e., those in the order Caudovirales ). Among the tools evaluated, VirSorter2 was also uniquely able to minimize errors associated with atypical cellular sequences including eukaryotic genomes and plasmids. Finally, as the virosphere exploration unravels novel viral sequences, VirSorter2’s modular design makes it inherently able to expand to new types of viruses via the design of new classifiers to maintain maximal sensitivity and specificity. Conclusion With multi-classifier and modular design, VirSorter2 demonstrates higher overall accuracy across major viral groups and will advance our knowledge of virus evolution, diversity, and virus-microbe interaction in various ecosystems. Source code of VirSorter2 is freely available ( https://bitbucket.org/MAVERICLab/virsorter2 ), and VirSorter2 is also available both on bioconda and as an iVirus app on CyVerse ( https://de.cyverse.org/de ).

59 BASIC BIOLOGICAL SCIENCES↗

PHYSICAL PROPERTIES OF THE 0.94-DAY PERIOD TRANSITING PLANETARY SYSTEM WASP-18

We present high-precision photometry of five consecutive transits of WASP-18, an extrasolar planetary system with one of the shortest orbital periods known. Through the use of telescope defocusing we achieve a photometric precision of 0.47-0.83 mmag per observation over complete transit events. The data are analyzed using the JKTEBOP code and three different sets of stellar evolutionary models. We find the mass and radius of the planet to be M {sub b} = 10.43 +- 0.30 +- 0.24 M {sub Jup} and R {sub b} = 1.165 +- 0.055 +- 0.014 R {sub Jup} (statistical and systematic errors), respectively. The systematic errors in the orbital separation and the stellar and planetary masses, arising from the use of theoretical predictions, are of a similar size to the statistical errors and set a limit on our understanding of the WASP-18 system. We point out that seven of the nine known massive transiting planets (M {sub b} > 3 M {sub Jup}) have eccentric orbits, whereas significant orbital eccentricity has been detected for only four of the 46 less-massive planets. This may indicate that there are two different populations of transiting planets, but could also be explained by observational biases. Further radial velocity observations of low-mass planets will make it possible to choose between these two scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed quantum sensing enhanced by continuous-variable error correction

Abstract A distributed sensing protocol uses a network of local sensing nodes to estimate a global feature of the network, such as a weighted average of locally detectable parameters. In the noiseless case, continuous-variable (CV) multipartite entanglement shared by the nodes can improve the precision of parameter estimation relative to the precision attainable by a network without shared entanglement; for an entangled protocol, the root mean square estimation error scales like 1/ M with the number M of sensing nodes, the so-called Heisenberg scaling, while for protocols without entanglement, the error scales like 1 / M . However, in the presence of loss and other noise sources, although multipartite entanglement still has some advantages for sensing displacements and phases, the scaling of the precision with M is less favorable. In this paper, we show that using CV error correction codes can enhance the robustness of sensing protocols against imperfections and reinstate Heisenberg scaling up to moderate values of M . Furthermore, while previous distributed sensing protocols could measure only a single quadrature, we construct a protocol in which both quadratures can be sensed simultaneously. Our work demonstrates the value of CV error correction codes in realistic sensing scenarios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hexagonal Uniformly Redundant Arrays (HURAs) for scintillator based coded aperture neutron imaging

A series of Monte Carlo simulations have been conducted, making use of the EJ-426 neutron scintillator detector, to investigate the potential of using hexagonal uniformly redundant arrays (HURAs) for scintillator based coded aperture neutron imaging. This type of scintillator material has a low sensitivity to gamma rays, therefore, is of particular use in a system with a source that emits both neutrons and gamma rays. The simulations used an AmBe source, neutron images have been produced using different coded-aperture materials (boron- 10, cadmium-113 and gadolinium-157) and location error has also been estimated. In each case the neutron image clearly shows the location of the source with a relatively small location error. Neutron images with high resolution can be easily used to identify and locate nuclear materials precisely in nuclear security and nuclear decommissioning applications. (authors)

42 ENGINEERING↗

TU-FG-201-03: Automatic Pre-Delivery Verification Using Statistical Analysis of Consistencies in Treatment Plan Parameters by the Treatment Site and Modality

Purpose: A novel computer software system, namely APDV (Automatic Pre-Delivery Verification), has been developed for verifying patient treatment plan parameters right prior to treatment deliveries in order to automatically detect and prevent catastrophic errors. Methods: APDV is designed to continuously monitor new DICOM plan files on the TMS computer at the treatment console. When new plans to be delivered are detected, APDV checks the consistencies of plan parameters and high-level plan statistics using underlying rules and statistical properties based on given treatment site, technique and modality. These rules were quantitatively derived by retrospectively analyzing all the EBRT treatment plans of the past 8 years at authors’ institution. Therapists and physicists will be notified with a warning message displayed on the TMS computer if any critical errors are detected, and check results, confirmation, together with dismissal actions will be saved into database for further review. Results: APDV was implemented as a stand-alone program using C# to ensure required real time performance. Mean values and standard deviations were quantitatively derived for various plan parameters including MLC usage, MU/cGy radio, beam SSD, beam weighting, and the beam gantry angles (only for lateral targets) per treatment site, technique and modality. 2D-based rules of combined MU/cGy ratio and averaged SSD values were also derived using joint probabilities of confidence error ellipses. The statistics of these major treatment plan parameters quantitatively evaluate the consistency of any treatment plans which facilitates automatic APDV checking procedures. Conclusion: APDV could be useful in detecting and preventing catastrophic errors immediately before treatment deliveries. Future plan including automatic patient identify and patient setup checks after patient daily images are acquired by the machine and become available on the TMS computer. This project is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Modeling the Swift BAT Trigger Algorithm with Machine Learning

To draw inferences about gamma-ray burst (GRB) source populations based on Swift observations, it is essential to understand the detection efficiency of the Swift burst alert telescope (BAT). This study considers the problem of modeling the Swift BAT triggering algorithm for long GRBs, a computationally expensive procedure, and models it using machine learning algorithms. A large sample of simulated GRBs from Lien et al. (2014) is used to train various models: random forests, boosted decision trees (with AdaBoost), support vector machines, and artificial neural networks. The best models have accuracies of approximately greater than 97% (approximately less than 3% error), which is a significant improvement on a cut in GRB flux which has an accuracy of 89:6% (10:4% error). These models are then used to measure the detection efficiency of Swift as a function of redshift z, which is used to perform Bayesian parameter estimation on the GRB rate distribution. We find a local GRB rate density of eta(sub 0) approximately 0.48(+0.41/-0.23) Gpc(exp -3) yr(exp -1) with power-law indices of eta(sub 1) approximately 1.7(+0.6/-0.5) and eta(sub 2) approximately -5.9(+5.7/-0.1) for GRBs above and below a break point of z(sub 1) approximately 6.8(+2.8/-3.2). This methodology is able to improve upon earlier studies by more accurately modeling Swift detection and using this for fully Bayesian model fitting. The code used in this is analysis is publicly available online.

gamma rays: general↗

SU-F-T-229: A Novel Method for EPID-Based In-Vivo Exit Dose Verification for Intensity Modulated Radiotherapy

Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), and can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.

60 APPLIED LIFE SCIENCES↗

Shared memory for a fault-tolerant computer

A system is described for sharing a memory in a fault-tolerant computer. The memory is under the direct control and monitoring of error detecting and error diagnostic units in the fault-tolerant computer. This computer verifies that data to and from the memory is legally encoded and verifies that words read from the memory at a desired address are, in fact, actually delivered from that desired address. The means are provided for a second processor, which is independent of the direct control and monitoring of the error checking and diagnostic units of the fault-tolerant computer, and to share the memory of the fault-tolerant computer. Circuitry is included to verify that: (1) the processor has properly accessed a desired memory location in the memory; (2) a data word read-out from the memory is properly coded; and (3) no inactive memory was erroneously outputting data onto the shared memory bus.

Gilley, G. C.↗

Towards an Error Model for OpenMP

OpenMP lacks essential features for developing mission-critical software. In particular, it has no support for detecting and handling errors or even a concept of them. In this paper, the OpenMP Error Model Subcommittee reports on solutions under consideration for this major omission. We identify issues with the current OpenMP specification and propose a path to extend OpenMP with error-handling capabilities. We add a construct that cleanly shuts down parallel regions as a first step. We then discuss two orthogonal proposals that extend OpenMP with features to handle system-level and user-defined errors.

97 MATHEMATICS AND COMPUTING↗

Using Pipelined XNOR Logic to Reduce SEU Risks in State Machines

Single-event upsets (SEUs) pose great threats to avionic systems state machine control logic, which are frequently used to control sequence of events and to qualify protocols. The risks of SEUs manifest in two ways: (a) the state machine s state information is changed, causing the state machine to unexpectedly transition to another state; (b) due to the asynchronous nature of SEU, the state machine's state registers become metastable, consequently causing any combinational logic associated with the metastable registers to malfunction temporarily. Effect (a) can be mitigated with methods such as triplemodular redundancy (TMR). However, effect (b) cannot be eliminated and can degrade the effectiveness of any mitigation method of effect (a). Although there is no way to completely eliminate the risk of SEU-induced errors, the risk can be made very small by use of a combination of very fast state-machine logic and error-detection logic. Therefore, one goal of two main elements of the present method is to design the fastest state-machine logic circuitry by basing it on the fastest generic state-machine design, which is that of a one-hot state machine. The other of the two main design elements is to design fast error-detection logic circuitry and to optimize it for implementation in a field-programmable gate array (FPGA) architecture: In the resulting design, the one-hot state machine is fitted with a multiple-input XNOR gate for detection of illegal states. The XNOR gate is implemented with lookup tables and with pipelines for high speed. In this method, the task of designing all the logic must be performed manually because no currently available logic synthesis software tool can produce optimal solutions of design problems of this type. However, some assistance is provided by a script, written for this purpose in the Python language (an object-oriented interpretive computer language) to automatically generate hardware description language (HDL) code from state-transition rules.

Le, Martin↗

A deterministic verification strategy for electrostatic particle-in-cell algorithms in arbitrary spatial dimensions using the method of manufactured solutions

As simulations of kinetic plasmas continue to increase in scope and complexity, a rigorous and straightforward method for verifying particle-in-cell (PIC) implementations is necessary to ensure their correctness. Here, in this paper, we present a deterministic method for the rigorous verification of multidimensional, multispecies, electrostatic particle-in-cell codes based on the method of manufactured solutions. Specifically, we prove that rigorous verification is possible through the exclusive examination of errors of grid quantities (i.e., moments and/or fields), allowing for a very light-weight and non-intrusive implementation in existing PIC codes. This is a marked improvement over earlier PIC verification approaches (only demonstrated with one species in 1D-1V), which rely on the comparison of cumulative distribution functions, and are invasive on the code base, introduce additional stochastic noise, are significantly more computationally expensive, and lack rigorous convergence properties. Interestingly, we show that different grid quantities feature different rates of convergence with the number of particles and mesh size, impacting the verification process. These theoretical results are confirmed numerically with a multi-species 2D-2V particle-in-cell code, including the ability of the method to detect order reduction due to an incorrect implementation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geometry-complete perceptron networks for 3D molecular graphs

Abstract Motivation The field of geometric deep learning has recently had a profound impact on several scientific domains such as protein structure prediction and design, leading to methodological advancements within and outside of the realm of traditional machine learning. Within this spirit, in this work, we introduce GCPNet, a new chirality-aware SE(3)-equivariant graph neural network designed for representation learning of 3D biomolecular graphs. We show that GCPNet, unlike previous representation learning methods for 3D biomolecules, is widely applicable to a variety of invariant or equivariant node-level, edge-level, and graph-level tasks on biomolecular structures while being able to (1) learn important chiral properties of 3D molecules and (2) detect external force fields. Results Across four distinct molecular-geometric tasks, we demonstrate that GCPNet’s predictions (1) for protein–ligand binding affinity achieve a statistically significant correlation of 0.608, more than 5%, greater than current state-of-the-art methods; (2) for protein structure ranking achieve statistically significant target-local and dataset-global correlations of 0.616 and 0.871, respectively; (3) for Newtownian many-body systems modeling achieve a task-averaged mean squared error less than 0.01, more than 15% better than current methods; and (4) for molecular chirality recognition achieve a state-of-the-art prediction accuracy of 98.7%, better than any other machine learning method to date. Availability and implementation The source code, data, and instructions to train new models or reproduce our results are freely available at https://github.com/BioinfoMachineLearning/GCPNet.

59 BASIC BIOLOGICAL SCIENCES↗

A new ensemble-based consistency test for the Community Earth System Model (pyCECT v1.0)

Abstract. Climate simulation codes, such as the Community Earth System Model (CESM), are especially complex and continually evolving. Their ongoing state of development requires frequent software verification in the form of quality assurance to both preserve the quality of the code and instill model confidence. To formalize and simplify this previously subjective and computationally expensive aspect of the verification process, we have developed a new tool for evaluating climate consistency. Because an ensemble of simulations allows us to gauge the natural variability of the model's climate, our new tool uses an ensemble approach for consistency testing. In particular, an ensemble of CESM climate runs is created, from which we obtain a statistical distribution that can be used to determine whether a new climate run is statistically distinguishable from the original ensemble. The CESM ensemble consistency test, referred to as CESM-ECT, is objective in nature and accessible to CESM developers and users. The tool has proven its utility in detecting errors in software and hardware environments and providing rapid feedback to model developers.

58 GEOSCIENCES↗

Water Vapor in Titan's Stratosphere from Cassini/CIRS Far-infrared Spectra

Since the first detection of water vapor in Titan's stratosphere by disk-average observations from the Infrared Space Observatory (Coustenis et al. 1998) we report here the successful detection of stratospheric water vapor using the Cassini Composite Infrared Spectrometer (CIRS, Flasar et al. 2004). CIRS senses water emissions in the far infrared spectral region near 50 microns, which we have modeled using two independent radiative transfer codes (NEMESIS, Irwin et al 2008 and ART, Coustenis et al. 2007, 2010). From the analysis of nadir spectra we have derived a mixing ratio of (0.14 0.05) ppb at an altitude of 97 kilometers, which corresponds to an integrated (from 0 to 600 kilometers) surface normalized column abundance of (3.7 plus or minus 1.3) x 10(exp 14) molecules per square centimeter. In the latitude range 80 S to 30 N we see no evidence for latitudinal variations in these abundances within the error bars. Using limb observations, we obtained mixing ratios of (0.13 plus or minus 0.04) ppb at an altitude of 115 kilometers and (0.45 plus or minus 0.15) ppb at an altitude of 230 kilometers, confirming that the water abundance has a positive vertical gradient as predicted by photochemical models (e.g. Lara et al. 1996, Wilson and Atreya 2004, Horst et al. 2008); retrieved scaling factors (from approximately 0.1 to approximately 0.6) to the water profile suggested by these models show that water vapor is present in Titan stratosphere with less abundance than predicted.

Cottini, V.↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗