Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

New millimeter-wave diagnostics to locally probe internal density and magnetic field fluctuations in National Spherical Torus Experiment-Upgrade (invited)

A set of new millimeter-wave diagnostics will deliver unique measurement capabilities for National Spherical Torus Experiment-Upgrade to address a variety of plasma instabilities believed to be important in determining thermal and particle transport, such as micro-tearing, global Alfvén eigenmodes, kinetic ballooning, trapped electron, and electron temperature gradient modes. These diagnostics include a new integrated intermediate-k Doppler backscattering (DBS) and cross-polarization scattering (CPS) system (four channels, 82.5–87 GHz) to measure density and magnetic fluctuations, respectively. The system can access reasonably large normalized wavenumbers k θ ρ s ranging from ≤0.5 to 15 (where ion sound gyroradius ρ s = 1 cm and k θ is the binormal density turbulence wavenumber). The system addresses the challenges for making useful DBS/CPS measurements with a remote control of launch polarization (X- or O-mode), probed wavenumber, polarization match of the launch beam with the edge magnetic field pitch angle, and beam steering of the launched beam for wave-vector alignment. In addition, a low-k DBS system consisting of eight fixed frequencies (34–52 GHz) and four tunable frequencies (55–75 GHz) for low-k density turbulence and fast ion physics will be located at a nearby port location. Finally, the combined systems cover the near LCFS and pedestal regions (34–52 GHz), the pedestal or mid-radius (50–75 GHz), and core plasmas (82.5–87 GHz).

47 OTHER INSTRUMENTATION↗

Three-dimensional reconstruction of laser-direct-drive inertial confinement fusion hot-spot plasma from x-ray diagnostics on the OMEGA laser facility (invited)

A deep-learning convolutional neural network (CNN) is used to infer, from x-ray images along multiple lines of sight, the low-mode shape of the hot-spot emission of deuterium–tritium (DT) laser-direct-drive cryogenic implosions on OMEGA. The motivation of this approach is to develop a physics-informed 3-D reconstruction technique that can be performed within minutes to facilitate the use of the results to inform changes to the initial target and laser conditions for the subsequent implosion. The CNN is trained on a 3D radiation-hydrodynamic simulation database to relate 2D x-ray images to 3D emissivity at stagnation. The CNN accounts for the lack of an absolute spatial reference and the different bands of photon energies in the x-ray images. While previous works studied the effect of mode-1 asymmetries on implosion performance using nuclear diagnostics, this work focuses on the effect of mode 2 inferred from x-ray diagnostics on implosion performance. A current analysis of 19 DT cryogenic implosions indicates there is an upper limit of ~20% reduction in the neutron yield caused by an ℓ = 2 amplitude for ℓ 2 /ℓ 0 ≤ 0.32. Here, these conclusions are supported by 2D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade

This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Demonstration of full-scale spatiotemporal diagnostics of solid-density plasmas driven by an ultra-short relativistic laser pulse using an X-ray free-electron laser

Understanding the complex plasma dynamics in ultra-intense relativistic laser–solid interactions is of fundamental importance for applications of laser–plasma-based particle accelerators, the creation of high-energy-density matter, understanding planetary science, and laser-driven fusion energy. However, experimental efforts in this regime have been limited by the lack of accessibility of over-critical densities and the poor spatiotemporal resolution of conventional diagnostics. Over the last decade, the advent of femtosecond brilliant hard X-ray free-electron lasers (XFELs) has opened new horizons to overcome these limitations. Here, for the first time, we present full-scale spatiotemporal measurements of solid-density plasma dynamics, including preplasma generation with tens of nanometer scale length driven by the leading edge of a relativistic laser pulse, ultrafast heating and ionization at the main pulse arrival, the laser-driven blast wave, and transient surface return current-induced compression dynamics up to hundreds of picoseconds after interaction. These observations are enabled by utilizing a novel combination of advanced X-ray diagnostics including small-angle X-ray scattering, resonant X-ray emission spectroscopy, and propagation-based X-ray phase-contrast imaging simultaneously at the European XFEL-HED beamline station.

Huang, Lingen [Helmholtz-Zentrum Dresden-Rossendor↗

Application of the portable diagnostic package to the Wisconsin high-temperature-superconducting axisymmetric mirror (WHAM)

We present an application of the Portable Diagnostic Package (PDP) on the Wisconsin High-temperature-superconducting Axisymmetric Mirror (WHAM), which integrates an optical emission spectroscopy (OES) system and an active Thomson scattering (TS) system. The OES system facilitates a comprehensive impurity line survey and enables flow measurements through the Doppler effect observed on impurity lines. Plasma rotation profiles were successfully derived from doubly charged carbon lines. The TS system enabled the first measurements of the electron temperature in commissioning plasmas on WHAM. Notably, the PDP was installed, commissioned, and used to obtain OES and TS data within ∼6 months from project start, enabled by its designed portability and standardized interfaces. These results demonstrate the PDP’s potential to accelerate diagnostic readiness and advance experimental plasma studies.

Doppler effect↗

Multi-diagnostic characterization of laser-produced tin plasmas for EUV lithography

We present a comprehensive characterization of laser-produced tin (Sn) plasmas relevant to extreme ultraviolet (EUV) lithography using a multi-diagnostic suite integrated into the new experimental platform, “SparkLight.” Tin plasmas are generated by irradiating a continuously moving tin-coated wire with laser pulses (1064 nm, 10 ns, up to 5.7 × 10 10 W/cm 2 ) and probed via coherent Thomson scattering, laser interferometry, and EUV emission spectroscopy. Thomson scattering measurements reveal electron temperatures and densities that decay with distance from the target. Densities derived from Thomson scattering are cross-validated against laser interferometry, showing excellent agreement. Correlating the results of these laser diagnostics with spatially resolved EUV spectroscopy suggests that the bulk of useful EUV emission originates within 150 μm of the target and is generated under suboptimal plasma conditions. This work demonstrates a practical integrated approach for plasma characterization in EUV source development.

Musikhin, S. [Princeton Plasma Physics Laboratory ↗

Application of deep neural networks to improve diagnostic accuracy of rheumatoid arthritis using diffuse optical tomography

A set of deep neural network models for rheumatoid arthritis (RA) classification using a highway network, a convolutional neural network and a residual network is proposed based on the data of diffuse optical tomography (DOT) utilising near-infrared light, which ensures early diagnosis of pathophysiological changes resulting from inflammation. A numerical model of the finger is used to generate images to overcome the inherent problem of insufficient clinical DOT images available. The proposed deep neural network models are applied to automatically classify simulated DOT images of inflamed and non-inflamed joints and transfer learning is also used to improve the performance of the classification. The results demonstrate that all three deep neural network methods improve the diagnostic accuracy as compared to the widely applied support vector machine (SVM), especially for high inter-subject variability databases. In cases of distinct modelled severity of disease, residual network achieved the highest accuracy (> 99 %), and both of highway and convolutional neural networks reached 99 %, respectively. However, as the severity of the modelled disease is reduced, this accuracy is reduced to 75.2 % for residual networks. The results indicate that transfer learning can improve the performance of deep neural network methods on RA classification from DOT data and highlight their potential as a computer aided tool in DOT diagnostic systems. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Analysis of the Performance of the ITER Diagnostic Residual Gas Analyzer

The composition of exhausted gas is a key parameter in long-pulse plasma fusion experiments, and its evolution shall be monitored at timescales relevant to plasma dynamics and plasma-wall interactions. A diagnostic residual gas analyzer (DRGA) is a multisensor instrument particularly suited to these studies, and ITER will adopt DRGAs in the equatorial and in the divertor tokamak regions. In this work, we have revisited the design of the ITER divertor DRGA through simple vacuum analytical considerations supported by simulations conducted with Molflow+, a test particle Monte Carlo (TPMC) simulation code commonly used in the particle accelerator community. Here, starting with recommendations on the manufacturing of the vacuum piping of the DRGA, this work is followed by a complete vacuum characterization of the diagnostic vacuum setup (pressure profiles at base pressure and during sampling, orifice diameter, and length optimization), and finally, the in-vessel residence time of the most important gas species is simulated. These studies have allowed us to give insights into some experimental results recently found on the prototype DRGA installed in the Wendelstein W7-X stellarator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wire, hybrid, and laser-cut X-pinches as Talbot–Lau backlighters for electron density diagnostics

Talbot–Lau x-ray deflectometry (TXD) enables refraction-based imaging for high-energy-density physics experiments, and thus, it has been studied and developed with the goal of diagnosing plasmas relevant to inertial confinement and magnetic liner inertial fusion. X-pinches, known for reliably generating fast (~1 ns), small (~1 µm) x-ray sources, were driven on the compact current driver generator for ablation structure and implosion studies (~200 kA, 150 ns) as a potential backlighter source for TXD. Considering that different X-pinch configurations have characteristic advantages and drawbacks as x-ray generating loads, three distinct copper X-pinch configurations were studied: the wire X-pinch, the hybrid X-pinch, and the laser-cut X-pinch. Furthermore, the Cu K-shell emission from each configuration was characterized and analyzed regarding the specific backlighter requirements for an 8 keV TXD system: spatial and temporal resolution, number of sources, time of emission, spectrum, and reproducibility. Recommendations for future experimental improvements and applications are presented. The electron density of static objects was retrieved from Moiré images obtained through TXD. This allowed to calculate the mass density of static samples within 4% of the expected value for laser-cut X-pinches, which were found to be the optimal X-pinch configuration for TXD due to their high reproducibility, small source size (≤5 µm), short duration (~1 ns), and up to 106 W peak power near 8 keV photon energy. Plasma loads were imaged through TXD for the first-time using laser-cut X-pinch backlighting. Experimental images were compared with simulations from the x-ray wave-front propagation code, demonstrating that TXD can be a powerful x-ray refraction-based diagnostic for dense Z-pinch loads. Future plans for Talbot–Lau interferometry diagnostics in the pulsed-power environment are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic x-ray source using electrons produced by a 100 J-class picosecond laser

Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f/#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.

backlighter↗

The Wendelstein 7-X phase contrast imaging diagnostic

We report a phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. The PCI diagnostic provides a line-integrated measurement of turbulent electron density fluctuations, which is essential for understanding high performance scenarios that can lead to improved confinement at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, which arise from Alfvén eigenmodes or other MHD activity. This paper provides an overview of the hardware and the optical system and presents an example PCI measurement from the W7-X OP1.2b experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated assessment model diagnostics: key indicators and model evolution

Integrated assessment models (IAMs) form a prime tool in informing climate mitigation strategies. Diagnostic indicators that allow to compare these models can help to describe and explain differences in model projections. This also increases transparency and comparability. Earlier, the IAM community has developed an approach to diagnose models (Kriegler et al., 2015). Here we build on this, by proposing a selected set of well-defined indicators as a community standard, similar to metrics used for other modeling communities such as climate models. These indicators are the relative abatement index (RAI), emission reduction type index (ERT), inertia timescale (IT), fossil fuel reduction (FFR), transformation index (TI) and cost per abatement value (CAV). We apply the approach to 17 IAMs, including both older version as well as their latest versions, as applied in the IPCC 6th Assessment Report (AR6). The study shows that the approach can be easily applied and allows for comparison of model versions in time. The indicators and their trends can often be explained in terms of model characteristics and changes. We show that together, the set of six indicators can provide an useful indication of the main traits of the model and can roughly indicate the general model behavior. The results also show that there is often a considerable spread across the models. Interestingly, the diagnostic values often change for different model versions, but there does not seem to be a distinct trend across the different models.

54 ENVIRONMENTAL SCIENCES↗

Line identification of boron and nitrogen emissions in EUV and VUV wavelength ranges in the impurity powder dropping experiments of LHD and its application to spectroscopic diagnostics

An impurity powder dropper was installed in the 21st campaign of the Large Helical Device experiment (Oct. 2019–Feb. 2020) under a collaboration between the National Institute for Fusion Science and the Princeton Plasma Physics Laboratory for the purposes of real-time wall conditioning and edge plasma control. In order to assess the effective injection of the impurity powders, spectroscopic diagnostics were applied to observe line emission from the injected impurity. Therefore, extreme-ultraviolet (EUV) and vacuum-ultraviolet (VUV) emission spectra were analyzed to summarize observable impurity lines with B and BN powder injection. Emission lines released from B and N ions were identified in the EUV wavelength range of 5–300 Å measured using two grazing incidence flat-field EUV spectrometers and in the VUV wavelength range of 300–2400 Å measured using three normal incidence 20 cm VUV spectrometers. BI–BV and NIII–NVII emission lines were identified in the discharges with the B and BN powder injection, respectively. Useful B and N emission lines which have large intensities and are isolated from other lines were successfully identified as follows: BI (1825.89, 1826.40) Å (blended), BII 1362.46 Å, BIII (677.00, 677.14, 677.16) Å (blended), BIV 60.31 Å, BV 48.59 Å, NIII (989.79, 991.51, 991.58) Å (blended), NIV 765.15 Å, NV (209.27, 209.31) Å (blended), NVI 1896.80 Å, and NVII 24.78 Å. Applications of the line identifications to the advanced spectroscopic diagnostics were demonstrated, such as the vertical profile measurements for the BV and NVII lines using a space-resolved EUV spectrometer and the ion temperature measurement for the BII line using a normal incidence 3 m VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of x-ray fluorescence spectroscopy as a sensitive temperature diagnostic for high-energy-density physics experiments

We present the use of x-ray fluorescence spectroscopy (XFS) to a sensitive temperature diagnostic in shocked foams at temperatures of 30–75 eV. Cobalt-doped foams were shock compressed using a planar drive at the OMEGA laser facility and photo-pumped with a Zn He⁢𝛼 x-ray source. Analysis of the resulting cobalt 𝐾⁢𝛽 x-ray fluorescence spectra using collisional radiative codes allows the temperature to be determined in the shocked foams. Furthermore, this method provides a sensitive and robust technique to determine temperatures in high-energy-density physics experiments in the tens of electronvolts temperature range. In these experiments, we find that radiation hydrodynamic simulations predict a lower temperature in the shocked foams compared to analysis of the XFS data using collisional radiative models. Although additional experiments with an independent temperature diagnostic to absolutely calibrate XFS spectra for these conditions will be required to resolve this discrepancy, these results demonstrate the excellent temperature sensitivity of XFS spectra for high-energy-density physics experiments.

Atomic spectra↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗