Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detect And Avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Viral RNA and Infectious Influenza Virus on Mobile Phones of Patients With Influenza in Hong Kong and the United States

Abstract Mobile phones are among the most highly touched personal objects. As part of a broader study on the contribution of fomites to influenza transmission, between 2017 and 2019, we swabbed mobile phones from 138 patients with influenza in 2 locations. Influenza viral RNA detection rates were 23% (23 of 99 phones) and 36% (14 of 39) in Hong Kong and Maryland, respectively. In Hong Kong, infectious influenza virus was recovered from 3 of 23 mobile phones which had influenza viral RNA detected. Mobile phone influenza contamination was positively associated with upper respiratory tract viral load and negatively associated with age. Cleaning personal objects of patients with influenza should be recommended, and individuals should avoid sharing objects with these patients.

Xiao, Jingyi↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗

Analysis of BWR OPRM plant data and detection algorithms with DSSPP

All U.S. BWRs are required to have licensed stability solutions that satisfy General Design Criteria (GDC) 10 and 12 of 10 CFR 50 Appendix A. Implemented solutions are either detect and suppress or preventive in nature. Detection and suppression of power oscillations is accomplished by specialized hardware and software such as the Oscillation Power Range Monitor (OPRM) utilized in Option III and Detect and Suppress Solution - Confirmation Density (DSS-CD) stability Long-Term Solutions (LTSs). The detection algorithms are designed to recognize a Thermal-Hydraulic Instability (THI) event and initiate control rod insertion before the power oscillations increase much higher above the noise level that may threaten the fuel integrity. Option III is the most widely used long-term stability solution in the US and has more than 200 reactor years of operational history. DSS-CD represents an evolutionary step from the stability LTS Option III and its licensed domain envelopes the Maximum Extended Load Line Limit Analysis Plus (MELLLA +) domain. In order to enhance the capability to investigate the sensitivity of key parameters of stability detection algorithms, GEH has developed a new engineering analysis code, namely DSSPP (Detect and Suppress Solution Post Processor), which is introduced in this paper. The DSSPP analysis tool represents a major advancement in the method for diagnosing the design of stability detection algorithms that enables designers to perform parametric studies of the key parameters relevant for THI events and to fine tune these system parameters such that a potential spurious scram might be avoided. Demonstrations of DSSPPs application are also presented in this paper utilizing actual plant THI data. A BWR/6 plant had a plant transient that included unplanned recirculation pump transfer from fast to slow speed resulting in about 100% to {approx}40% rated power decrease and about 99% to {approx}30% rated core flow decrease. As the feedwater temperature is reduced to equilibrium conditions, the power increased from about {approx}40% to about {approx}60% with little change inflow. A THI event developed and subsequently, an OPRM initiated scram occurred with Option III. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Contrasting Time-Frequency Representations for Unknown Waveform Detection

In real-world applications like spectrum management and interference detection, dealing with unseen electromagnetic waveforms is critical. Although some methods attempt to simulate open set data using generator models, they face challenges in generating synthetic samples for open set while simultaneously selecting an optimal discriminator for accurate classification. This results in difficulties capturing distinctive features across classes, especially in dynamic scenarios where new classes emerge. To detect unseen waveforms, we propose combining time and frequency domain features with cosine similarity loss to enhance feature distinctiveness and enabling more accurate predictions. This approach efficiently captures more comprehensive information than single-domain representations or approaches without cosine loss. Additionally, our model avoids generic feature vectors by extracting class-specific features during training, resulting in improved class representation. The experiment results show that this combined feature approach with cosine loss outperforms single-domain models and improves accuracy by 10\% over models without cosine loss.

99 - GENERAL AND MISCELLANEOUS↗

On The gamma-ray emission from Reticulum II and other dwarf galaxies

The recent discovery of ten new dwarf galaxy candidates by the Dark Energy Survey (DES) and the Panoramic Survey Telescope and Rapid Response System (Pan-STARRS) could increase the Fermi Gamma-Ray Space Telescope's sensitivity to annihilating dark matter particles, potentially enabling a definitive test of the dark matter interpretation of the long-standing Galactic Center gamma-ray excess. In this paper, we compare the previous analyses of Fermi data from the directions of the new dwarf candidates (including the relatively nearby Reticulum II) and perform our own analysis, with the goal of establishing the statistical significance of any gamma-ray signal from these sources. We confirm the presence of an excess from Reticulum II, with a spectral shape that is compatible with the Galactic Center signal. The significance of this emission is greater than that observed from 99.84% of randomly chosen high-latitude blank-sky locations, corresponding to a local detection significance of 3.2σ. We caution that any dark matter interpretation of this excess must be validated through observations of additional dwarf spheroidal galaxies, and improved calculations of the relative J-factor of dwarf spheroidal galaxies. We improve upon the standard blank-sky calibration approach through the use of multi-wavelength catalogs, which allow us to avoid regions that are likely to contain unresolved gamma-ray sources.

79 ASTRONOMY AND ASTROPHYSICS↗

UNDERSTANDING DUAL ACTIVE GALACTIC NUCLEUS ACTIVATION IN THE NEARBY UNIVERSE

We study the fraction of dual active galactic nuclei (AGNs) in a sample of 167 nearby (z < 0.05), moderate-luminosity, ultra-hard X-ray-selected AGNs from the all-sky Swift Burst Alert Telescope (BAT) survey. Combining new Chandra and Gemini observations together with optical and X-ray observations, we find that the dual AGN frequency at scales <100 kpc is {approx}10% (16/167). Of the 16 dual AGNs, only 3 (19%) were detected using X-ray spectroscopy and were not detected using emission line diagnostics. Close dual AGNs (<30 kpc) tend to be more common among the most X-ray luminous systems. In dual AGNs, the X-ray luminosity of both AGNs increases strongly with decreasing galaxy separation, suggesting that the merging event is key in powering both AGNs. Fifty percent of the AGNs with a very close companion (<15 kpc) are dual AGNs. We also find that dual AGNs are more likely to occur in major mergers and tend to avoid absorption line galaxies with elliptical morphologies. Finally, we find that SDSS Seyferts are much less likely than BAT AGNs (0.25% versus 7.8%) to be found in dual AGNs at scales <30 kpc because of a smaller number of companion galaxies, fiber collision limits, a tendency for AGNs at small separations to be detected only in X-rays, and a higher fraction of dual AGN companions with increasing AGN luminosity.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing Industrial Catalysts using in situ XAFS under Identical Conditions

In situ X-ray absorption spectroscopy (XAS) in catalysis research has traditionally been conducted by making one measurement at a time on a single sample. In an industrial research environment this is especially limiting as sample throughput (productivity) and turnaround time (direct project relevance) are critical issues in the use of XAS in a fast-moving technology delivery project. In order to address these issues we have developed and implemented a four-channel ionization chamber combined with two different in situcells that allows XAS data to be collected simultaneously from four samples, or four regions, in transmission geometry without any sample or detector movement. In the development of this new capability it was realized that there are other benefits from this simultaneous detection in addition to increased productivity. Namely, (i) the use of EXAFS to determine the structure of a catalystin situ axially at four different positions down a catalyst bed; (ii) the ability to collect up to four XAFS spectra simultaneously and thereby avoid any scan-to-scan uncertainties, and (iii) the added confidence in the ability to discriminate small differences in similarly prepared catalysts which is typical in the development of a commercial catalyst. Specific illustrations of each of these applications are shown. The methodology is simple to implement and could be used on any XAFS beamline with a horizontal fan of radiation, such as at a typical bending magnet or wiggler source beamline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arsenic, lead, mercury and cadmium: Toxicity, levels in breast milk and the risks for breastfed infants

Metals are ubiquitous in nature, being found in all environmental compartments, and have a variety of applications in human activities. Metals are transferred by maternal blood to the fetus via the placenta, and exposure continues throughout life. For the general population, exposure comes mainly from water and food consumption, including breast milk. In this paper, we reviewed studies on the toxicity of arsenic, lead, mercury and cadmium, the toxic metals of most concern to human health, focusing on the potential risks to newborns and infants. A total of 75 studies published since 2000 reporting the levels of these metals in breast milk were reviewed. Lead was the metal most investigated in breast milk (43 studies), and for which the highest levels were reported (up to 1515 µg/L). Arsenic was the least investigated (18 studies), with higher levels reported for breast milk (up to 149 µg/L) collected in regions with high arsenic concentrations in water (>10 µg/L). Data from 34 studies on mercury showed that levels in breast milk were generally higher in populations with high fish consumption, where it may be present mainly as MeHg. Cadmium levels in breast milk were the lowest, with means <2 µg/L in most of the 29 studies reviewed. Results of risk assessments indicated that the intake of arsenic, lead and mercury by infants through breastfeeding can be considered a health concern in most regions of the world. Although the potential risks to infants are mostly outweighed by the benefits of breast milk consumption, it is essential that contaminants be continuously monitored, especially in the most critical regions, and that measures be implemented by health authorities to reduce exposure of newborns and infants to these metals, and thus avoid unnecessary health risks. - Highlights: • Review of 75 studies that analyzed arsenic, lead, mercury and/or cadmium levels. • Higher levels of arsenic found in India; of mercury found in Brazil. • Lead was the most detected in the studies; cadmium levels were the lowest. • Risk for breastfed babies cannot be excluded for arsenic, lead and mercury. • Risks are unavoidable, and outweighed by the benefits of breastfeeding.

54 ENVIRONMENTAL SCIENCES↗

Two dimensional growth of ultrathin Fe films on BaTiO{sub 3} with sharp chemical interface

The Fe/BaTiO{sub 3} interface is a prototypical artificial multiferroic system displaying purely electronic magnetoelectric effects at room temperature. As magneto-electric coupling is essentially localized at the interface, the properties of the very first Fe layers in contact with BaTiO{sub 3} play a major role. In this paper, we investigate, by using X-ray photoemission spectroscopy and photoelectron diffraction, the in-situ growth, by molecular beam epitaxy, of ultrathin Fe films (∼7 monolayers) on a BaTiO{sub 3}/SrTiO{sub 3}(001) template. We found that growing the Fe films above room temperature (373 K) is essential in order to avoid island growth and obtain a continuous film. Post-annealing up to 473 K improves the film crystallinity but prevents chemical interdiffusion and roughening. Just an interfacial monolayer of oxidized iron is detected in these conditions, which appears as an unavoidable consequence of the Fe/BaTiO{sub 3} chemical interaction. Its active role in magnetoelectric coupling must be carefully taken into account to correlate theoretical predictions and experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A semi-supervised machine learning detector for physics events in tokamak discharges

Databases of physics events have been used in various fusion research applications, including the development of scaling laws and disruption avoidance algorithms, yet they can be time-consuming and tedious to construct. This paper presents a novel application of the label spreading semi-supervised learning algorithm to accelerate this process by detecting distinct events in a large dataset of discharges, given few manually labeled examples. A high detection accuracy (> 85%) for H-L back transitions and initially rotating locked modes is demonstrated on a dataset of hundreds of discharges from DIII-D with manually identified events for which only 3 discharges are initially labeled by the user. Lower yet reasonable performance (~75%) is also demonstrated for the core radiative collapse, an event with a much lower prevalence in the dataset. Additionally, analysis of the performance sensitivity indicates that the same set of algorithmic parameters is optimal for each event. Furthermore, this suggests that the method can be applied to detect a variety of other events not included in this paper, given that the event is well described by a set of 0D signals robustly available on many discharges. Procedures for analysis of new events are demonstrated, showing automatic event detection with increasing fidelity as the user strategically adds manually labeled examples. Detections on Alcator C-Mod and EAST are also shown, demonstrating the potential for this to be used on a multi-tokamak dataset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-D-213-06: Quantitative Image Quality Metrics Are for Physicists, Not Radiologists: How to Communicate to Your Radiologists Using Their Language

Purpose: A framework for explaining differences in image quality to non-technical audiences in medial imaging is needed. Currently, this task is something that is learned “on the job.” The lack of a formal methodology for communicating optimal acquisition parameters into the clinic effectively mitigates many technological advances. As a community, medical physicists need to be held responsible for not only advancing image science, but also for ensuring its proper use in the clinic. This work outlines a framework that bridges the gap between the results from quantitative image quality metrics like detectability, MTF, and NPS and their effect on specific anatomical structures present in diagnostic imaging tasks. Methods: Specific structures of clinical importance were identified for a body, an extremity, a chest, and a temporal bone protocol. Using these structures, quantitative metrics were used to identify the parameter space that should yield optimal image quality constrained within the confines of clinical logistics and dose considerations. The reading room workflow for presenting the proposed changes for imaging each of these structures is presented. The workflow consists of displaying images for physician review consisting of different combinations of acquisition parameters guided by quantitative metrics. Examples of using detectability index, MTF, NPS, noise and noise non-uniformity are provided. During review, the physician was forced to judge the image quality solely on those features they need for diagnosis, not on the overall “look” of the image. Results: We found that in many cases, use of this framework settled mis-agreements between physicians. Once forced to judge images on the ability to detect specific structures inter reader agreement was obtained. Conclusion: This framework will provide consulting, research/industrial, or in-house physicists with clinically relevant imaging tasks to guide reading room image review. This framework avoids use of the overall “look” or “feel” to dictate acquisition parameter selection. Equipment grants GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Poster – 02: Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences

PET images are affected by the presence of scattered photons. Incorrect scatter-correction may cause artifacts, particularly in 3D PET systems. Current scatter reconstruction methods do not distinguish between single and higher order scattered photons. A dual-scattered reconstruction method (GDS-MLEM) that is independent of the number of Compton scattering interactions and less sensitive to the need for high energy resolution detectors, is proposed. To avoid overcorrecting for scattered coincidences, the attenuation coefficient was calculated by integrating the differential Klein-Nishina cross-section over a restricted energy range, accounting only for scattered photons that were not detected. The optimum image can be selected by choosing an energy threshold which is the upper energy limit for the calculation of the cross-section and the lower limit for scattered photons in the reconstruction. Data was simulated using the GATE platform. 500,000 multiple scattered photon coincidences with perfect energy resolution were reconstructed using various methods. The GDS-MLEM algorithm had the highest confidence (98%) in locating the annihilation position and was capable of reconstructing the two largest hot regions. 100,000 photon coincidences, with a scatter fraction of 40%, were used to test the energy resolution dependence of different algorithms. With a 350–650 keV energy window and the restricted attenuation correction model, the GDS-MLEM algorithm was able to improve contrast recovery and reduce the noise by 7.56%–13.24% and 12.4%–24.03%, respectively. This approach is less sensitive to the energy resolution and shows promise if detector energy resolutions of 12% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A semi-supervised machine learning detector for physics events in tokamak discharges

Databases of physics events have been used in various fusion research applications, including the development of scaling laws and disruption avoidance algorithms, yet they can be time-consuming and tedious to construct. This paper presents a novel application of the label spreading semi-supervised learning algorithm to accelerate this process by detecting distinct events in a large dataset of discharges, given few manually labeled examples. A high detection accuracy (>85%) for H-L back transitions and initially rotating locked modes is demonstrated on a dataset of hundreds of discharges from DIII-D with manually identified events for which only 3 discharges are initially labeled by the user. Lower yet reasonable performance (~75%) is also demonstrated for the core radiative collapse, an event with a much lower prevalence in the dataset. Additionally, analysis of the performance sensitivity indicates that the same set of algorithmic parameters is optimal for each event. This suggests that the method can be applied to detect a variety of other events not included in this paper, given that the event is well described by a set of 0D signals robustly available on many discharges. Procedures for analysis of new events are demonstrated, showing automatic event detection with increasing fidelity as the user strategically adds manually labeled examples. Detections on Alcator C-Mod and EAST are also shown, demonstrating the potential for this to be used on a multi-tokamak dataset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiological Diagnosis and Management of Epistaxis

The majority of episodes of spontaneous posterior epistaxis treated with embolisation are idiopathic in nature. The angiographic findings are typically normal. Specific angiographic signs are rare and may include the following: a tumour blush, telangiectasia, aneurysm, and/or extravasation. Selective internal carotid artery (ICA) angiography may show rare causes of epistaxis, such as traumatic or mycotic aneurysms, which require different treatment approaches. Complete bilateral selective external and internal carotid angiograms are essential to evaluation. The images should be analysed for detection of central retinal blush in the external carotid artery (ECA) and anastomoses between the branches of the ECA and ICA. Monocular blindness and stroke are two of the most severe complications. Embolisation aims to decrease flow to the bleeding nasal mucosa while avoiding necrosis of the nasal skin and palate mucosa. Embolisation is routinely performed with a microcatheter positioned in the internal maxillary artery distal to the origin of the meningeal arteries. A guiding catheter should be placed in the proximal portion of the ECA to avoid vasospasm. Embolisation with microparticles is halted when the peripheral branches of the sphenopalatine artery are occluded. The use of coils is not recommended because recurrent epistaxis may occur due to proximal embolization; moreover, the option of repeat distal embolisation is lost. The success rate of embolisation therapy (accounting for late recurrence of bleeding) varies between 71 and 94 %. Results from endoscopic surgery are quite comparable. When epistaxis is refractory to nasal packing or endoscopic surgery, embolisation is the treatment of choice in some centres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sol-gel synthesis of mesoporous CaCu{sub 3}Ti{sub 4}O{sub 12} thin films and their gas sensing response

A new sol-gel synthesis procedure of stable calcium copper titanate (CaCu{sub 3}Ti{sub 4}O{sub 12}-CCTO) precursor sols for the fabrication of porous films was developed. The composition of the sol was selected in order to avoid the precipitation of undesired phases; ethanol was used as solvent, acetic acid as modifier and poly(ethyleneglycol) as a linker agent. Films deposited by spin-coating onto oxidized silicon substrates were annealed at 700 {sup o}C. The main phase present in the samples, as detected by X-ray diffraction and Raman spectroscopy, was CaCu{sub 3}Ti{sub 4}O{sub 12}. Scanning electron microscopy analysis showed that mesoporous structures, with thicknesses between 200 and 400 nm, were developed as a result of the processing conditions. The films were tested regarding their sensibility towards oxygen and nitrogen at atmospheric pressure using working temperatures from 200 to 290 {sup o}C. The samples exhibited n-type conductivity, high sensitivity and short response times. These characteristics indicate that CCTO mesoporous structures obtained by sol-gel are suitable for application in gas sensing. - Graphical abstract: A sol-gel synthesis procedure toward stable CaCu{sub 3}Ti{sub 4}O{sub 12}-precursor sols avoiding the precipitation of undesired compounds is proposed. Films deposited by spin-coating onto oxidized silicon substrates were annealed at 700 {sup o}C. The thickness varied between 200 and 400 nm depending on sol composition. The films, tested as gas sensors for O{sub 2}, showed n-type conductivity, good sensitivity and short response times.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thick branes in extra dimensions and suppressed dark couplings

The nature of dark matter (DM) and how it may interact with the various fields of the Standard Model (SM) remains a mystery. In this paper we show that the interaction between new light dark matter mediators and the SM particles can be naturally suppressed if one employs a single, flat extra dimension (ED). In this setup, the SM fields are localized in a finite width ‘fat’ brane, similar to models of Universal Extra Dimensions (UED), while DM, in turn, is confined to a thin brane at the opposite end of the ED interval. Including brane localized kinetic terms on the fat brane for the mediator fields, the resulting coupling between the SM and these light mediators can be several orders of magnitude smaller than the corresponding ones between the mediators and DM which we assume to be a typical gauge coupling. We investigate the implications of this scenario for both vector (i.e, dark photon, DP) and scalar mediator fields in the 5-D bulk. In this setup kinetic mixing, which is usually employed to suppress light mediator couplings, is not required. Here we assume that the SM particles couple to the DP via their B - L charges while the DP couples to the DM via a dark charge. Both the vector DP couplings and the corresponding Higgs portal couplings with the SM are shown to be natural small in magnitude with a size dependent on ratio of the 5-D compactification radius, R -1 ~ 0.1-1 GeV, and the SM brane thickness, L -1 ~ 2-10 TeV, a range chosen to avoid LHC and other experimental constraints. In this framework one can obtain the observed value of the DM relic abundance for a wide range of parameter choices, while the constrains due to direct DM detection and the invisible width of the Higgs do not impose significant challenges to the model. Finally, this mechanism can lead to distinct signatures in both present and upcoming experiments as it combines some common features of UED and DP models in a single ED setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nitrogen diffusion in silicate minerals, with implications for nitrogen transport and cycling in the lithosphere

Diffusion laws for nitrogen in orthoclase, quartz, olivine and clinopyroxene were determined using a combination of experimental strategies that included: in-diffusion from C-H-O-N vapor; in-diffusion from molten NH 4 Cl; and ion implantation followed by heating to mobilize N. Most experiments were conducted at pressures near 1 bar, but seven experiments were also run in a piston-cylinder device at P total = 1 GPa. The C-H-O-N-source experiments were “wet” (H 2 O present); those on ion-implanted samples were dry. All N sources were highly enriched in 15 N to avoid spurious 14 N signals resulting from surface contamination. Use of 15 N also enabled depth profiling by nuclear reaction analysis (NRA) using the 15 N(p,αγ) 12 C reaction, which has a detection limit of ~10 ppm. Nitrogen profiles in three samples were characterized by both NRA and SIMS, with similar results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovative biomagnetic imaging sensors for breast cancer: A model-based study

Breast cancer is a serious potential health problem for all women and is the second leading cause of cancer deaths in the United States. The current screening procedures and imaging techniques, including x-ray mammography, clinical biopsy, ultrasound imaging, and magnetic resonance imaging, provide only 73% accuracy in detecting breast cancer. This gives the impetus to explore alternate techniques for imaging the breast and detecting early stage tumors. Among the complementary methods, the noninvasive biomagnetic breast imaging is attractive and promising, because both ionizing radiation and breast compressions that the prevalent x-ray mammography suffers from are avoided. It furthermore offers very high contrast because of the significant electromagnetic properties' differences between the cancerous, benign, and normal breast tissues. In this paper, a hybrid and accurate modeling tool for biomagnetic breast imaging is developed, which couples the electromagnetic and ultrasonic energies, and initial validations between the model predication and experimental findings are conducted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗