Diagnosis of high-density, highly ionized nitrogen wind tunnel flows.
High density highly ionized nitrogen flow in plasma wind tunnel
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High density highly ionized nitrogen flow in plasma wind tunnel
Plasma properties and atmospheric composition deduced from antenna impedance measurements during planetary entry
Radioisotopic lung scanning for locating pulmonary aeroemboli following decompression
Diagnosing faults on operational synchronous digital systems
Nozzle expansion of air in hypersonic electric arc heated wind tunnel
Error detecting and correcting codes for locating logic faults in digital computers
Electronic control for space shuttle main engine
Precision machining and repair of radioactive Plum Brook Reactor core fuel grid
Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.
Electron velocity distributions are deduced along axes parallel and perpendicular to the magnetic field in a pulsed, linear Penning discharge in hydrogen by means of a laser Thomson scattering experiment. Results obtained are numerical averages of many individual measurements made at specific space-time points in the plasma evolution. Because of the high resolution in k-space and the relatively low maximum electron density 2 x 10 to the 13th power/cu cm, special techniques were required to obtain measurable scattering signals. These techniques are discussed and experimental results are presented.
Renin is a proteolytic enzyme secreted by the kidney. Techniques for the direct measurement of renin content of human blood are not available at the present time. Two of the best known causes of remediable hypertension can be diagnosed from abnormalities in renin activity and aldosterone production. In renovascular hypertension, renin secretion is increased because of impaired glomerular perfusion. The renin activity assay, when applied in a carefully controlled fashion, is a useful screening test for treatable causes of hypertension.
Published report discusses fault location properties of arithmetic codes. Criterion for effectiveness of given code is detection probability of local fault by application of checking algorithm to results of entire set of algorithms of processor. Report also presents analysis of arithmetic codes with low-cost check algorithm which possesses partial fault-location properties.
The response characteristics of high sensitivity piezoelectric pressure transducers suitable for use in the plasma flow induced by megawatt-level electric discharges in low density (less than 1 Torr) gases are described. The uniquely designed probe records the initial impingement of a large magnitude total pressure pulse, followed by the flow of primary interest with order-of-magnitude smaller signals. Effects relating to probe and support accelerations, blast shielding and probe heating are evaluated and accounted for in a probe system with a sensitivity of 40 V/atm.
An experimental investigation for estimating the nonlinearity of a diagnostic object was carried out on a single-stage, spur gear reducer. The linearity of the properties of spur gearing (including the linearity of its mode of operation) was tested. Torsional vibrations of the driven wheel and transverse (to the meshing plane) vibrations of the drive wheel on its support were taken as the two outputs of the object to be analyzed. The results of the investigation showed that the degree of nonlinearity of a reducing gear is essentially connected with its operating mode, so that different mathematical models of it can correspond to different values of the system parameters.
The physics of noise formation in an internal combustion engine is discussed. A dependence of the acoustical radiation on the engine operating process, its construction, and operational parameters, as well as on the degree of wear on its parts, has been established. An example of tests conducted on an internal combustion engine is provided. A system for cybernetic diagnostics for internal combustion engines by vibroacoustical parameters is diagrammed.
Photography technique determines amount of morbidity present in tissue. Imaging apparatus incorporates numerical filtering. Overall system operates in near-real time. Information gained from this system enables physician to understand extent of injury and leads to accelerated treatment.
Measurements have been made of coherence and phase spectra for the acoustic field in a subsonic wind tunnel. The data are interpreted in terms of simple analytical models for propagating and diffuse noise fields, including the presence of uncorrelated noise signals. It is found that low frequency noise propagates upstream and downstream from the fan, with the noise in the test section arriving in the upstream direction. High frequency sound is generated in the test section and propagates upstream and downstream. In the low frequency range, the ratio of diffuse to propagating energy is about eight for all locations in the test section, diffuser, and settling chamber; the value of the ratio increases with frequency.