Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Long-Term Stewardship at a Former Uranium Mill Tailings Site in Riverton, Wyoming - 17090

The US Department of Energy Office of Legacy Management (LM) is responsible for maintaining protective public health and environmental conditions at former uranium mill tailings sites nationwide via long-term stewardship. One of these sites, a former uranium mill near Riverton, Wyoming, is within the boundary of the Wind River Indian Reservation and operated from 1958 to 1963. Tailings and contaminated material associated with mill operations were removed and transported to an offsite disposal cell in 1989. The remedial action was completed under Title I of the Uranium Mill Tailings Radiation Control Act of 1978. Milling operations, which included an unlined tailings impoundment and an unlined evaporation pond, contaminated the shallow groundwater, resulting in a down-gradient groundwater plume that discharges to the Little Wind River. A natural flushing compliance strategy was implemented in 1998. This strategy allows contaminants of concern to naturally flush from the groundwater, provided that contaminants flush below US Environmental Protection Agency maximum concentration limits within 100 years. As part of the compliance strategy, LM has implemented a groundwater monitoring program along with institutional controls that include the installation of an alternate water supply, continued sampling of private wells, and restrictions on well drilling and gravel pit construction. LM works closely with local stakeholders and community members to ensure that these institutional controls are in place and maintained. The Riverton site provides an interesting case study where contaminant remobilization due to river flooding prompted a reevaluation of the conceptual site model to verify if the current compliance strategy would remain protective of human health and the environment. Concentrations of groundwater contaminants, which include sulfate, molybdenum, and uranium, were transiently elevated following flooding of the Little Wind River in 2010 and 2016. These flood events provided the impetus to investigate other aspects of the hydrologic system, including the unsaturated zone, naturally reduced (sulfidic) zones, and evaporite deposits. New site conceptual models, field and laboratory studies, and numerical models are being developed to explain how biogeochemical sediment-water interactions contribute to plume persistence and flood-related increases in groundwater concentrations. Updated human health and ecological risk assessments are progressing to evaluate the risk to human health and the environment based on current site conditions. Groundwater concentrations may remain above US Environmental Protection Agency maximum concentration limits beyond the 100-year natural flushing regulatory time frame. LM in its capacity as a long-term steward continues to monitor the site to ensure protectiveness is maintained and to determine the feasibility of alternative compliance and remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Application for Dust Control in the Central Plateau: Impacts, Alternatives, and Work Strategies

Dust control is needed during many activities at the Hanford Site for health and safety purposes and to prevent contaminant dispersal via atmospheric transport. Spraying of water is the baseline approach at the Hanford Site for dust control in most applications, including use during excavation activities, on roadways and disturbed areas, for facility demolition, and during construction activities. Use of water at or near waste sites may introduce infiltration to the subsurface. As such, the recharge rate (hydraulic driving force) through the vadose zone and to the groundwater may be increased by an extent related to the duration and amount of water applied. An increased recharge rate can increase contaminant fluxes toward the groundwater and potentially induce lateral movement depending on the magnitude of the recharge rate. Thus, dust suppression via water spray is of potential concern for contaminants in the vadose zone. Because Hanford remediation work is transitioning from the River Corridor to efforts on the Central Plateau where there is a significant inventory of contaminants in the vadose zone, dust suppression approaches for these efforts will need to understand the potential negative effects of water addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2015 Assessment of Mercury in the Savannah River Site Environment and Responses to the Agency for Toxic Substances and Disease Registry 2012 Report on Assessment of Biota Exposure to Mercury Originating from the Savannah River Site

The purpose of this report is to 1) update previous Savannah River National Laboratory (SRNL) assessment reports (Kvartek et al. 1994 and Halverson et al. 2008) on the fate of mercury in the Savannah River Site (SRS) environment and 2) address comments and recommendations from the review of SRS by the Agency for Toxic Substances and Disease Registry (ATSDR) concerning the evaluation of exposures to contaminants in biota originating from the SRS. The ATSDR reviewed and evaluated data from SRS, South Carolina Department of Health & Environmental Control (SCDHEC) and the Georgia Department of Natural Resources (GDNR) concerning the non-radioactive contaminant mercury. This report will provide a response and update to conclusions and recommendations made by the ATSDR.

54 ENVIRONMENTAL SCIENCES↗

Effect of Acetonitrile Contamination on Long-Term Degradation of Proton Exchange Membrane Fuel Cells

A long-term contamination (for 1000 hrs) test is conducted under constant current operation with 5 ppm acetonitrile in the air stream, and the results are compared to those for a controlled blank single-cell test. The long-term effects of the contaminant on cell performance and the structure of the membrane electrodes assembly are identified by a series of analyses, including electrochemical impedance spectroscopy, cyclic voltammetry, ion chromatography, transmission electron microscopy and scanning electron microscopy. During the long-term test, the acetonitrile significantly decreases the cell performance for a 0.1-mg Pt cm -2 catalyst coated membrane. The acetonitrile contamination accelerates catalyst particle growth; however, interestingly, it inhibited membrane degradation. This result may provide a possible approach for improving fuel cell durability.

25 ENERGY STORAGE↗

Native Plants in Floodplain in Controlling Hg Flux into East Fork Poplar Creek of Oak Ridge - 18166

Legacy Hg contamination has been identified as the highest priority clean-up risk on the Oak Ridge Reservation (ORR) by the Department of Energy Office of Environmental Management (DOE-EM), Tennessee Department of Environment and Conservation (TDEC), and the US Environmental Protection Agency (EPA). During the 1950's and early 1960's, elemental mercury (Hg) was used to produce enriched Li isotope at the Y-12 National Security Complex (Y-12 Plant) for manufacturing components of various nuclear weapons systems. It is estimated that 350,000 kg of Hg was released to the environment contaminating facilities, soil, sediment, surface water, and groundwater within the boundaries of the Y-12 Plant and the downstream environment (i.e., East Fork Poplar Creek, EFPC). EFPC is a 23-km stream where the headwaters start in the Y-12 Plant, flows through the city of Oak Ridge, and empties into the Clinch River. Although various remediation efforts have reduced Hg fluxes from the Y-12 Plant over the last 25 years, the Hg concentration in water continue to exceed both the regulatory limit (51 ng/L) and the remediation goal (200 μg/L). Perennial grasses as floodplain plants have been successfully employed to control surface runoff and stabilize the floodplain. Hg has been strongly bound to particles suspended with surface runoff. Miscanthus grass is a perennial, tall grass that is adjusted to coarse, fine and medium textured soils. Although it grows best in deep, well-drained floodplain soils it is tolerant of poor to excessive well-drained soils, has an extensive tolerance for acidic to alkaline soils, and tolerates soil textures ranging from sand to clay. These long tangled root systems can reach moisture more deeply than other grasses during drought thus anchoring the plant into the soil. The fine appearance and branching hairs grow to form a dense mat that helps improve soil structure by increasing porosity and adding organic material that helps to bind soil particles together. In compacted or clay soils, spreading roots increase soil porosity by creating fractures in soil aggregates allowing water to penetrate deeper within the subsoil. This study showed that DOE remediation significantly reduced residual Hg to be <400 mg/kg in floodplain. However the residual Hg was mostly present in non-cinnabar mercury which is more bioavailable than cinnabar. The current study also found that Hg transfer flux from floodplain soils through surface soils with trees and grasses under natural rainfall events was an average of 0.28±0.15 μg/L, which was similar to the Hg concentrations in water of EFPC as reported by ORNL. Total Hg concentrations and Hg and speciation in floodplain soils were strongly affected by particle size distribution. Fine particles had higher Hg concentrations rich in cinnabar Hg. Clay particles contained as high as 2000-1600 mg/kg Hg with most Hg as cinnabar Hg, while coarse particles contained less total Hg, dominated by non-cinnabar Hg. Hg speciation in floodplain soil strongly controls its solubility, mobility, and bioavailability in both terrestrial/ aquatic ecosystems and downstream Hg concentrations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed power generation via gasification of biomass and municipal solid waste: A review

The access to electricity has increased worldwide, growing from 60 million additional consumers per year in 2000-2012 to 100 million per year in 2012-2016. Despite this growth, approximately 675 million people will still lack access to electricity in 2030, indicating that electricity demand will continue to increase. Unfortunately, traditional large fossil power technologies based on coal, oil and natural gas lead to a major concern in tackling worldwide carbon dioxide emissions, and nuclear power remains unpopular due to public safety concerns. Distributed power generation utilizing CO 2 -neutral sources, such as gasification of biomass and municipal solid wastes (MSW), can play an important role in meeting the world energy demand in a sustainable way. Furthermore, this review focuses on the recent technology developments on seven power generation technologies (i.e. internal combustion engine, gas turbine, micro gas turbine, steam turbine, Stirling engine, organic rankine cycle generator, and fuel cell) suitable for distributed power applications with capability of independent operation using syngas derived from gasification of biomass and MSW. Technology selection guidelines is discussed based on criteria, including hardware modification required, size inflexibility, sensitivity to syngas contaminants, operational uncertainty, efficiency, lifetime, fast ramp up/down capability, controls and capital cost. Major challenges facing further development and commercialization of these power generation technologies are discussed.

09 BIOMASS FUELS↗

Dominant Controls on Preferential Flow and Their Implications for Future Soil Water Fluxes

Abstract Soil water flow, particularly preferential flow (PF), is a critical control on hydrological and biogeochemical processes, including groundwater recharge, contaminant transport, and carbon cycling. However, it remains challenging to predict PF occurrence across large environmental gradients. Here, we developed a deep learning (DL) model to estimate event‐scale soil water flow velocity and the probability of PF occurrence using high‐frequency soil moisture and precipitation data from 33 sites across the National Ecological Observatory Network. The model demonstrated high skill in predicting the binary occurrence of PF (91% F1‐score; 85% accuracy) but the performance was limited in predicting soil water velocity ( R 2 = 0.31). We found that precipitation characteristics (duration, volume, and intensity) were the most important predictors for soil water velocity. Among the non‐precipitation event variables, sand content showed relatively high predictive skill, though differences among non‐event climate variables were generally modest. Lower sand content was associated with increased predicted soil water velocity, a finding that highlights the role of soil structure in producing more non‐uniform flow, which contrasts with traditional uniform flow models. Projecting a reduced DL model under both moderate and high‐emissions future climate scenarios (2060–2099 Representative Concentration Pathways 4.5 and 8.5), we found ∼7.3% increase under RCP4.5 and ∼15% under RCP8.5 of soil water velocities compared to the historical simulation, while modeled likelihood of PF changed little. These findings suggest climate change is not making PF more frequent, but it is making existing PF pathways more efficient with important consequences for associated nutrient and contaminant transport under climate change. Plain Language Summary Water movement in soil is critical for water quality. While often modeled as a uniform flow process, in reality water moves rapidly through cracks and burrows in what is called “preferential flow” (PF), which limits natural filtration and can transport pollutants. We developed a deep learning model, trained on data from 33 U.S. sites, to predict when and how fast this PF occurs based on precipitation, soil, and climate data. The model showed that precipitation characteristics (duration, intensity, volume) were the most important predictors of PF. Lower soil sand content/higher clay content was associated with faster water flow, likely due to clay soils forming aggregates and cracks that water moves through rather than infiltrating uniformly. Further analyses based on climate projections suggest that the speed at which PF occurs will become more rapid under future climate scenarios compared to historical simulation. This highlights the need to represent PF in soil water models when assessing future water quality. Key Points The effect of precipitation peak intensity on soil water velocities declined with increasing precipitation intensity Antecedent soil moisture failed to predict preferential flow (PF), contrasting the high predictive power of sand content Climate predictions suggest that soil water velocities through PF paths will increase ∼15% by 2099

Li, Bonan↗

A per-cent-level determination of the nucleon axial coupling from quantum chromodynamics

The axial coupling of the nucleon, g A , is the strength of its coupling to the weak axial current of the standard model of particle physics, in much the same way as the electric charge is the strength of the coupling to the electromagnetic current. This axial coupling dictates the rate at which neutrons decay to protons, the strength of the attractive long-range force between nucleons and other features of nuclear physics. Precision tests of the standard model in nuclear environments require a quantitative understanding of nuclear physics that is rooted in quantum chromodynamics, a pillar of the standard model. The importance of g A makes it a benchmark quantity to determine theoretically—a difficult task because quantum chromodynamics is non-perturbative, precluding known analytical methods. Lattice quantum chromodynamics provides a rigorous, non-perturbative definition of quantum chromodynamics that can be implemented numerically. It has been estimated that a precision of two per cent would be possible by 2020 if two challenges are overcome: contamination of g A from excited states must be controlled in the calculations and statistical precision must be improved markedly. Here we use an unconventional method inspired by the Feynman–Hellmann theorem that overcomes these challenges. Furthermore, we calculate a g A value of 1.271 ± 0.013, which has a precision of about one per cent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RNAcentral: a hub of information for non-coding RNA sequences

RNAcentral is a comprehensive database of non-coding RNA (ncRNA) sequences, collating information on ncRNA sequences of all types from a broad range of organisms. We have recently added a new genome mapping pipeline that identifies genomic locations for ncRNA sequences in 296 species. We have also added several new types of functional annotations, such as tRNA secondary structures, Gene Ontology annotations, and miRNA-target interactions. A new quality control mechanism based on Rfam family assignments identifies potential contamination, incomplete sequences, and more. The RNAcentral database has become a vital component of many workflows in the RNA community, serving as both the primary source of sequence data for academic and commercial groups, as well as a source of stable accessions for the annotation of genomic and functional features. These examples are facilitated by an improved RNAcentral web interface, which features an updated genome browser, a new sequence feature viewer, and improved text search functionality.

Sweeney, Blake A.↗

BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 555: Godiva Benchmark Update CED-2 (Final Design Report)

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluation of the Godiva IV critical assembly, HEU-MET-FAST-086: GODIVA-IV DELAYED-CRITICAL EXPERIMENTS (HMF-086), was completed by Russ Mosteller. Five critical experiment configurations performed at the Los Alamos National Laboratory (LANL) Technical Area (TA)-18 were evaluated as acceptable benchmark cases. The five cases consist of four delayed critical configurations which differ in control rod positions and one prompt critical configuration. All cases calculated a lower $k_{eff}$ than measured by experiment. This data is referred to as the TA-18 Godiva IV benchmark in this report. In 2005, Godiva IV was disassembled for relocation to the Nevada Test Site (NTS), now Nevada National Security Site (NNSS), at the National Criticality Experiments Research Center (NCERC). Following the disassembly and subsequent reassembly and startup of Godiva IV at NCERC, additional information about the Godiva IV components was obtained. An errata note was added to the HMF-086 evaluation in the ICSBEP handbook to provide this new information until a revision to the benchmark evaluation could be performed. In addition to those corrections, there are differences between the Godiva IV assembly at TA-18 and the Godiva IV assembly at NCERC. These differences include both assembly-specific differences (differences in the safety block gap, differences in the control rod positions, a new NCERC Top Hat and contamination shield) as well as environmental differences, such as the size and shape of the experimental building where the assembly is located. An additional model with similar cases, referred to as the NCERC Godiva IV benchmark in this report, will be added to the revised HMF-086 to capture these additional differences. This will provide the best benchmark model of Godiva for use by those performing experiments at NCERC. The IER 555 CED-2 report documents the information that will be updated in the HMF-086 revision, both the corrections to the TA-18 Godiva IV benchmark and the subsequent changes to create a NCERC Godiva IV benchmark. It describes the measurements that will be performed for cases similar to those performed at TA-18. It also describes measurements that will be included in the evaluation as additional data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demolition of the K-27 Building at the East Tennessee Technology Park (ETTP) - 17423

On February 8, 2016, URS - CH2M Oak Ridge LLC (UCOR) initiated the demolition of the East Tennessee Technology Park's (ETTP's) final gaseous diffusion building in DOE's Oak Ridge Environmental Management program. Building K-27 was a 35,582 m{sup 2} (383,000 ft{sup 2}) gaseous diffusion building that contained approximately 92,903 m{sup 2} (1 million ft{sup 2}) of floor space. It was one of five gaseous diffusion buildings at the site, formerly known as the Oak Ridge Gaseous Diffusion Plant. The actual demolition of this facility took approximately seven months to complete; however, planning and preparation took more than three years. The deactivation process was a critical element in preparing the building for demolition. UCOR's K-27 deactivation activities began in April 2012 with the installation of safe walking paths and fall protection systems to allow safe work access. Next, all mechanical and electrical systems associated with the facility were shut down and isolated, a process known as 'cold and dark.' More than 19.3 km (12 mi) of process piping and components were marked and measured. Additionally, workers performed nondestructive assay (NDA) and vent-purge-and-drain activities and applied foam to piping and components as needed [1]. Based on characterization results, approximately 4.8 km (3 mi) of process piping, and 372 converters and compressors were removed and shipped offsite prior to demolition. Lower-hazard materials and equipment were demolished with the building structure and transported to onsite disposal facilities. Upfront waste characterization and ongoing monitoring were key to the successful disposal of demolition debris at onsite facilities. Due to process improvements in waste loading recommended by work crews, the project achieved a 50 percent improvement in the daily hauling rate during the 9,000-truckload shipping campaign. Crews worked in high-risk, high-hazard conditions and were exposed to radiological and chemical contaminants, extreme temperatures, and deteriorating infrastructure. However, the hazard controls that were put in place, based on the Integrated Safety Management System (ISMS) walk-downs and hazard determination, made the effort manageable. The overall safety performance during demolition of the facility was excellent, with no significant injuries, and exceeded industry standards and DOE target levels. Outstanding safety performance was a testament to the dedication of the workforce, given the significant hazards presented by the demolition of the Hazard Category 2 nuclear facility. Another key element to the success of the K-27 demolition was the support and approval of all stakeholders involved in this effort, including DOE, the surrounding communities, the State of Tennessee, the UCOR management team, and, most importantly, the workforce that performed this highly hazardous work. This $52 million demolition project was completed ahead of schedule with no significant injuries and in compliance with all DOE orders, site procedures, and environmental controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monticello Mill Tailings Site Operable Unit III Annual Groundwater Report May 2014 Through April 2015, October 2015

This report provides the annual analysis of water quality restoration progress, cumulative through April 2015, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1,700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site (OU I) and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. Contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern. LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of Significant Difference to include a pump-and-treat system using a single extraction well and treatment by zero-valent iron (ex-situ treatment system). The contingency action was optimized in 2015 with the installation of 8 extraction wells and 16 monitoring wells in a focused area of the aquifer (area of attainment). Contaminated water is treated by solar evaporation at an existing onsite LM facility. Environmental monitoring at OU III consists of twice-yearly (April and October) collection and analysis of hydrologic and water-quality data from an established network of observation wells, seeps, and surface water locations. The scope of monitoring was expanded in 2009 for the ex situ treatment system and in 2015 for the remedy optimization system. Operation and monitoring of the ex situ treatment system was discontinued in 2014 with the start-up of the remedy optimization system. No data anomalies for OU III water quality trending or restoration progress are identified for the May 2014 through April 2015 reporting period. Although some regions of the aquifer demonstrate decreasing concentration trends, such trending is not evident for the bulk of the aquifer and a prolonged restoration period is indicated. The groundwater contingency remedy optimization system captures significant contaminant mass (primarily uranium) from the area of attainment; however, because that system only became operational in 2015, a long-term forecast of restoration progress is premature.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Physical Properties of Streambed Interface Sediments Using In Situ Complex Electrical Conductivity Measurements

Streambed sediment physical properties such as surface area, are difficult to quantify in situ but exert a high-level control on a wide range of biogeochemical processes and sorption of contaminants. We introduce the use of complex electrical conductivity (CC) methods (also known as spectral-induced polarization (SIP)) that measure both real and imaginary conductivity to noninvasively and efficiently characterize shallow streambed sediments. We explore the method through synthetic modeling, laboratory, and field measurements to demonstrate the sensitivity of imaginary conductivity to sediment surface area, controlled in part by fine-grained iron oxides produced by anoxic groundwater discharge. Laboratory measurements verify expected relationships between CC parameters and sediment properties. Synthetic modeling using a 1D analytical model illustrates the influence of water layer depth and conductivity on the field CC measurements made at the streambed-stream water interface. Specifically, the inverted sediment imaginary conductivity is less impacted by uncertainty in the water layer depth and conductivity relative to the real conductivity and phase shift. Field CC measurements along a landfill-impacted river reveal discrete streambed zones with enhanced bulk surface area generally corresponding to anoxic groundwater discharge zones with high concentrations of fine-grained iron oxide precipitates.

54 ENVIRONMENTAL SCIENCES↗

Highly-Active and Contaminant-Tolerant Cathodes for Durable Solid Oxide Fuel Cells (Final Report)

The objective of this project is to investigate the fundamental degradation methods occurring in solid oxide fuel cell (SOFC) cathodes when exposed to chromium and carbon dioxide contamination and to rationally design alkaline earth-based catalysts to increase stability and tolerance to contaminate poisoning. With a mechanistic and fundamental understanding of the degradation methods, advanced catalytic surface modifications can be applied to reduce degradation. The specific technical objectives are: (1) To identify/develop new catalysts (alkaline-earth based-) that are compatible chemically with the state-of-the-art cathode materials at high temperatures required for fabrication and with contaminates commonly encountered under operating conditions; (2) To improve the infiltration process for optimal control of the thickness, composition, and uniformity of the catalyst coatings; (3) To evaluate the electro-catalytic activity toward ORR of the chemically-stable materials when exposed to different types of contaminants using electrical conductivity relaxation measurements on bar samples and performance evaluation of catalyst-infiltrated cathodes; (4) To unravel the contamination-tolerant mechanisms of the new catalyst coatings under realistic environmental conditions (with different types of contaminants) using powerful in situ and in operando characterization techniques performed on model cells with thin-film/pattern electrodes, as guided by modeling and simulation; (5) To establish scientific basis for rational design of new catalysts of high tolerance to contaminants; (6) To validate the long term stability of modified LSCF cathodes in commercially available cells/stacks under ROC. Alkaline earth-based catalysts have been systematically explored and tested under various contamination conditions. BaCoO 3-δ (BCO) was shown to produce the best catalytic activity enhancement as well as stability in a variety of contaminating conditions, including CO 2 and chromium. The microstructural evolution was investigated with SEM, EDS, and Raman spectroscopy, showing the BCO catalyst prevents the formation of insulating SrCrO 4 by forming electrically conductive BaCrO 4 . Electrochemical relaxation measurements determined the BCO catalyst coatings increased the surface diffusion coefficient but did not significantly affect the diffusion coefficient and determined an optimum surface modification layer of 100 nm. A novel Ba 0.9 Co 0.7 Fe 0.2 Nb 0.1 O x (BCFN) catalyst was also shown to have excellent stability in chromium containing atmospheres. A novel surface sol-gel (SSG) surface modification, which offers superior thickness and compositional control, was applied to SOFCs to produce BaO catalyst coatings. SSG BaO coatings were shown to produce conformal coatings on the electrode surface, greatly increasing stability in chromium containing atmospheres. An atomic level mechanistic approach was applied to investigate the stability of PrBa 0.8 Ca 0.2 Co2O 5+δ (PBCC) with respect to a variety of common contaminants, demonstrating thermodynamically its superior stability in CO2 containing atmospheres. Finally, the best catalyst coatings demonstrated in this project, BCO and PBCC, were applied to full cells which demonstrated superior stability for over 300 hours in CO 2 and Cr atmospheres.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly-Active and Contaminant-Tolerant Cathodes for Durable Solid Oxide Fuel Cells

The objective of this project is to investigate the fundamental degradation methods occurring in solid oxide fuel cell (SOFC) cathodes when exposed to chromium and carbon dioxide contamination and to rationally design alkaline earth-based catalysts to increase stability and tolerance to contaminate poisoning. With a mechanistic and fundamental understanding of the degradation methods, advanced catalytic surface modifications can be applied to reduce degradation. The specific technical objectives are: (1) To identify/develop new catalysts (alkaline-earth based-) that are compatible chemically with the state-of-the-art cathode materials at high temperatures required for fabrication and with contaminates commonly encountered under operating conditions; (2) To improve the infiltration process for optimal control of the thickness, composition, and uniformity of the catalyst coatings; (3) To evaluate the electro-catalytic activity toward ORR of the chemically-stable materials when exposed to different types of contaminants using electrical conductivity relaxation measurements on bar samples and performance evaluation of catalyst-infiltrated cathodes; (4) To unravel the contamination-tolerant mechanisms of the new catalyst coatings under realistic environmental conditions (with different types of contaminants) using powerful in situ and in operando characterization techniques performed on model cells with thin-film/pattern electrodes, as guided by modeling and simulation; (5) To establish scientific basis for rational design of new catalysts of high tolerance to contaminants; (6) To validate the long term stability of modified LSCF cathodes in commercially available cells/stacks under ROC. Alkaline earth-based catalysts have been systematically explored and tested under various contamination conditions. BaCoO 3-δ (BCO) was shown to produce the best catalytic activity enhancement as well as stability in a variety of contaminating conditions, including CO 2 and chromium. The microstructural evolution was investigated with SEM, EDS, and Raman spectroscopy, showing the BCO catalyst prevents the formation of insulating SrCrO 4 by forming electrically conductive BaCrO 4 . Electrochemical relaxation measurements determined the BCO catalyst coatings increased the surface diffusion coefficient but did not significantly affect the diffusion coefficient and determined an optimum surface modification layer of 100 nm. A novel Ba 0.9 Co 0.7 Fe 0.2 Nb 0.1 O x (BCFN) catalyst was also shown to have excellent stability in chromium containing atmospheres. A novel surface sol-gel (SSG) surface modification, which offers superior thickness and compositional control, was applied to SOFCs to produce BaO catalyst coatings. SSG BaO coatings were shown to produce conformal coatings on the electrode surface, greatly4 increasing stability in chromium containing atmospheres. An atomic level mechanistic approach was applied to investigate the stability of PrBa 0.8 Ca 0.2 Co 2 O 5+δ (PBCC) with respect to a variety of common contaminants, demonstrating thermodynamically its superior stability in CO 2 containing atmospheres. Finally, the best catalyst coatings demonstrated in this project, BCO and PBCC, were applied to full cells which demonstrated superior stability for over 300 hours in CO 2 and Cr atmospheres.

30 DIRECT ENERGY CONVERSION↗

Highly-Active and Contaminant-Tolerant Cathodes for Durable Solid Oxide Fuel Cells

The objective of this project is to investigate the fundamental degradation methods occurring in solid oxide fuel cell (SOFC) cathodes when exposed to chromium and carbon dioxide contamination and to rationally design alkaline earth-based catalysts to increase stability and tolerance to contaminate poisoning. With a mechanistic and fundamental understanding of the degradation methods, advanced catalytic surface modifications can be applied to reduce degradation. The specific technical objectives are: (1) To identify/develop new catalysts (alkaline-earth based-) that are compatible chemically with the state-of-the-art cathode materials at high temperatures required for fabrication and with contaminates commonly encountered under operating conditions; (2) To improve the infiltration process for optimal control of the thickness, composition, and uniformity of the catalyst coatings; (3) To evaluate the electro-catalytic activity toward ORR of the chemically-stable materials when exposed to different types of contaminants using electrical conductivity relaxation measurements on bar samples and performance evaluation of catalyst-infiltrated cathodes; (4) To unravel the contamination-tolerant mechanisms of the new catalyst coatings under realistic environmental conditions (with different types of contaminants) using powerful in situ and in operando characterization techniques performed on model cells with thin-film/pattern electrodes, as guided by modeling and simulation; (5) To establish scientific basis for rational design of new catalysts of high tolerance to contaminants; (6) To validate the long term stability of modified LSCF cathodes in commercially available cells/stacks under ROC. Alkaline earth-based catalysts have been systematically explored and tested under various contamination conditions. BaCoO 3-δ (BCO) was shown to produce the best catalytic activity enhancement as well as stability in a variety of contaminating conditions, including CO 2 and chromium. The microstructural evolution was investigated with SEM, EDS, and Raman spectroscopy, showing the BCO catalyst prevents the formation of insulating SrCrO 4 by forming electrically conductive BaCrO 4 . Electrochemical relaxation measurements determined the BCO catalyst coatings increased the surface diffusion coefficient but did not significantly affect the diffusion coefficient and determined an optimum surface modification layer of 100 nm. A novel Ba 0.9 Co 0.7 Fe 0.2 Nb 0.1 O x (BCFN) catalyst was also shown to have excellent stability in chromium containing atmospheres. A novel surface sol-gel (SSG) surface modification, which offers superior thickness and compositional control, was applied to SOFCs to produce BaO catalyst coatings. SSG BaO coatings were shown to produce conformal coatings on the electrode surface, greatly 4 increasing stability in chromium containing atmospheres. An atomic level mechanistic approach was applied to investigate the stability of PrBa 0.8 Ca 0.2 Co 2 O 5+δ (PBCC) with respect to a variety of common contaminants, demonstrating thermodynamically its superior stability in CO 2 containing atmospheres. Finally, the best catalyst coatings demonstrated in this project, BCO and PBCC, were applied to full cells which demonstrated superior stability for over 300 hours in CO 2 and Cr atmospheres

01 COAL, LIGNITE, AND PEAT↗