Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Conditional Normalizing Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Hydrological Drought in the Anthropocene: Impacts of Local Water Extraction and Reservoir Regulation in the U.S.

Hydrological drought is a substantial negative deviation from normal hydrologic conditions and is influenced by climate and human activities such as water management. By perturbing the streamflow regime, climate change and water management may significantly alter drought characteristics in the future. Here we utilize a high-resolution integrated modeling framework that represents water management in terms of both local surface water extraction and reservoir regulation, and use the Standardized Streamflow Index (SSI) to quantify hydrological drought. We explore the impacts of water management on hydrological drought over the contiguous US in a warming climate with and without emissions mitigation. Despite the uncertainty of climate change impacts, local surface water extraction consistently intensifies drought that dominates at the regional to national scale. However, reservoir regulation alleviates drought by enhancing summer flow downstream of reservoirs. The relative dominance of drought intensification or relief is largely determined by the water demand, with drought intensification dominating in regions with intense water demand such as the Great Plains and California, while drought relief dominates in regions with low water demand. Here, at the national level, water management increases the spatial extent of extreme drought despite some alleviations of moderate to severe drought. In an emissions mitigation scenario with increased irrigation demand for bioenergy production, water management intensifies drought more than the business-as-usual scenario at the national level, so the impacts of emissions mitigation must be evaluated by considering its benefit in reducing warming and evapotranspiration against its effects on increasing water demand and intensifying drought.

54 ENVIRONMENTAL SCIENCES↗

Building the Next Generation of Regional Geothermal Potential Maps: Examples from the Great Basin Region, Western USA

Over the past decade research has greatly advanced our understanding of structurally controlled geothermal systems and the potential for “deep stratigraphic reservoirs” in the Great Basin region, western USA. For example, studies have shown that structurally controlled geothermal systems are associated with specific structural settings, such as terminations of major normal faults, accommodation zones, pull-aparts in strike-slip faults, displacement transfer zones, or step-overs in range-front faults. However, we know that not every structure (e.g., termination of a major normal fault or step-over in a range-front fault) hosts an active geothermal system. Recent research has also shown that regional strain rate model as determined from GPS geodesy, the composition of that strain (extensional versus shear or compressive strain), recency of Quaternary faulting, and slip and dilation tendency of faults correlate positively with the distribution of both high and low-temperature, structurally controlled geothermal systems within the Great Basin. Combining these strain data and fault slip history data sets with existing temperature gradient data, heat flow data, spring temperatures, fluid geothermometry, and geophysical data provides an effective platform for evaluating the geothermal potential of respective structural plays. Recent studies focused on deep stratigraphic reservoirs indicate the best conditions for economically viable development are associated with thick sedimentary basins with low-thermal-conductivity sedimentary cap rocks overlying permeable host rocks (e.g. carbonates) and co-located with areas of high heat flow. Some of the factors that contribute to the potential for deep stratigraphic reservoirs and conventional structurally controlled geothermal systems apply to both types of resources, and in some places the potential for these two types of resources overlap in space, suggesting the potential for hybrid reservoirs (structurally controlled deep stratigraphic reservoirs). Effective and complete evaluation of geothermal potential in the Great Basin should include parameters that cover both types of resources. In this study, two areas with a combined area of 26,000 km 2 were evaluated for geothermal resource potential, equating to <4% of the total 680,000 km 2 size of the Great Basin region. Within these two study areas, 73 potential structural targets and 8 potential deep sedimentary target areas were identified. Four of the 73 potential structural target areas are associated with known thermal anomalies. All 73 structural target areas were ranked according to multiple data sets.

15 GEOTHERMAL ENERGY↗

Monitored Fluctuating Hydrodynamics

We introduce a hydrodynamic framework for describing monitored classical stochastic processes. We study the conditional ensembles for these monitored processes—i.e., we compute spacetime correlation functions conditioned on a fixed, typical measurement record. In the presence of global symmetries we show that these conditional ensembles can undergo measurement-induced “sharpening” phase transitions as a function of the monitoring rate; moreover, even weak monitoring can give rise to novel critical phases, derived entirely from a classical perspective. We give a simple hydrodynamic derivation of the known “charge-fuzzy phase” for weakly monitored diffusive many-body quantum systems. We show that although the unmonitored symmetric and asymmetric exclusion processes are in different universality classes of transport, the fluctuations in their conditional ensembles flow to the same fixed point with emergent relativistic invariance under monitoring. On the other hand, weakly monitored systems with non-Abelian symmetries enter a novel strongly coupled fixed point with nontrivial dynamical exponent, which we characterize. Our formalism naturally accounts for monitoring general observables, such as currents or density gradients, and allows for a direct calculation of information-theoretic diagnostics of sharpening transitions, including the Shannon entropy of the measurement record.

classical statistical mechanics↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Waste handling and storage in the decontamination pilot projects of JAEA for environments of Fukushima

After the Fukushima Daiichi nuclear accident, Japan Atomic Energy Agency (JAEA) was chosen by the national government to conduct decontamination pilot projects at selected sites in Fukushima prefecture. Despite tight boundary conditions in terms of timescale and resources, the projects served their primary purpose to develop a knowledge base to support more effective planning and implementation of stepwise regional remediation of the evacuated zone. A range of established, modified and newly developed techniques were tested under realistic field conditions and their performance characteristics were determined. The results of the project can be summarized in terms of site characterization, cleanup and waste management. A range of options were investigated to reduce the volumes of waste produced and to ensure that decontamination water could be cleaned to the extent that it could be discharged to normal drainage. Resultant solid wastes were packaged in standard flexible containers, labelled and stored at the remediation site (temporary storage until central interim storage becomes available). The designs of such temporary storage facilities were tailored to available sites, but all designs included measures to ensure mechanical stability (e.g., filling void spaces between containers with sand, graded cover with soil) and prevent releases to groundwater (impermeable base and cap, gravity flow drainage including radiation monitors and catch tanks). Storage site monitoring was also needed to check that storage structures would not be perturbed by external events that could include typhoons, heavy snowfalls, freeze/thaw cycles and earthquakes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing

A Tank-Side Cesium Removal (TSCR) system is under development by Washington River Protection Solutions to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. Tank waste supernate will be filtered to remove suspended solids and then Cs will be removed by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable after undetermined storage time. Previous testing with AP-105 simulant showed that rinsing the CST bed with 3 bed volumes (1.4 apparatus volumes [AVs]) of 0.1 M NaOH resulted in a dried bed that maintained flow characteristics indicative of ease of recovery. This study explored the intermediate conditions (between feed dried in place and the 1.4 AVs of 0.1 M NaOH rinse) to evaluate CST bed properties after: 1) stoppage with feed in place; 2) stoppage after draining feed; 3) stoppage after 0.7 AV of 0.1 M NaOH rinse through column; 4) stoppage after 1.5 AVs of 0.1 M NaOH rinse through column. Post processing, each column was heated at 50 °C for 19 days under pseudo-storage conditions to simulate the expected dried and stored CST bed conditions. Testing was conducted at the small scale (12-mL bed volume); actual, Cs-depleted, AP-105 tank waste was used as the feed. Post-dried CST bed physical properties (angle of repose and penetration depth) were measured to evaluate how CST moved and flowed. All process stop-conditions resulted in a solidified CST bed except for the final condition, 1.5 AVs of 0.1 M NaOH rinse. At this small scale, the three CST beds presented an issue for retrievability after the short storage period (19 days at 50 °C). The latter case confirmed the results from simulant testing. The testing was intended to provide a preliminary assessment of issues that may arise from desiccation of CST during storage with the indicated salt solutions in place. Since these were small-scale tests, the processing system did not scale to full scale conditions exactly; however, the tests did provide insight into the impact on the dried and stored CST bed after stopping processing at an earlier step (upset condition) than normal. These results indicate that if an upset condition occurs at TSCR, a dilute hydroxide rinse should be considered before the CST dries from internal heating.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Macroscopic modeling of gas permeability in hierarchical micro/nanoporous media: A unified characterization of rarefaction using Klinkenberg theory and equivalent diameter

Estimating gas transport through a hierarchical micro/nanoporous system is challenging due to non-equilibrium gas dynamics. The primary difficulty lies in determining the rarefaction level, because identifying a representative flow dimension in a complex porous system with multiple pore scales is not straightforward. Our study performed a pore-level analysis for gas permeability in dual-scale porous media with varying porosity, throat size, and secondary pore size under different rarefaction conditions. We found that secondary porosity negatively affects permeability due to increased friction forces, with this influence growing as the secondary pore size and porosity increase until the secondary pore becomes comparable to the throat. However, rarefaction reduces the effects of secondary pores due to boundary slip. Traditional Knudsen number (Kn) calculations based on Darcy-defined height failed to accurately describe the rarefaction effects on gas permeability. Instead, we introduced an equivalent diameter to calculate the Kn, which provided an accurate normalization of apparent gas permeability independent of pore geometry. Furthermore, the extended Kozeny–Carman–Klinkenberg model developed in our previous study successfully yielded a macroscopic model for apparent gas permeability in hierarchical micro/nanoporous systems as a function of the traditional Darcy height and porosity.

04 OIL SHALES AND TAR SANDS↗

Report on Sodium Compatibility of Advanced Structural Materials

This report provides an update on the evaluation of sodium structural materials. The report is a deliverable (level 3) in FY11 (M3A11AN04030403), under the Work Package A-11AN040304, “Sodium Compatibility of Advanced Structural Materials” performed by Argonne National Laboratory (ANL), as part of Advanced Structural Materials Program for the Advanced Reactor Concepts. This work package supports the advanced structural materials development by providing corrosion and tensile data from the standpoint of sodium compatibility of advanced structural alloys. The scope of work involves exposure of advanced structural alloys such as G92, mod.9Cr-1Mo (G91) ferritic-martensitic steels and HT-UPS austenitic stainless steels to a flowing sodium environment with controlled impurity concentrations. The exposed specimens are analyzed for their corrosion performance, microstructural changes, and tensile behavior. Previous reports examined the thermodynamic and kinetic factors involved in the design, fabrication, and construction of a forced convection sodium loop for sodium compatibility studies of advanced materials. This report presents the results on corrosion performance, microstructure, and tensile properties of advanced ferritic-martensitic and austenitic alloys exposed to liquid sodium at 550°C for up to 2700 h and at 650°C for up to 5064 h in the forced convection sodium loop. The oxygen content of sodium was controlled by the cold-trapping method to achieve ~1 wppm oxygen level. Four alloys were examined, G92 in the normalized and tempered condition (H1 G92), G92 in the cold-rolled condition (H2 G92), G91 in the normalized and tempered condition, and hot-rolled HT-UPS. G91 was included as a reference to compare with advanced alloy, G92. It was found that all four alloys showed weight loss after sodium exposures at 550 and 650°C. The weight loss of the four alloys was comparable after sodium exposures at 550°C; the weight loss of ferritic-martensitic steels, G92 and G91 is more significant than that of austenitic stainless steel, HT-UPS after sodium exposures at 650°C. Sodium exposures up to 2700 h at 550°C had no significant influence on tensile properties, while sodium exposures up to 5064 h at 650°C dramatically lowered the tensile strengths of the four alloys. The ultimate tensile strength of H1 G92, H2 G92, and G91 ferritic-martensitic steels was reduced to as much as nearly half of its initial value after sodium exposures at 650°C. Though the uniform elongation was recovered to some extent, these three ferritic-martensitic steels showed considerable strain softening after sodium exposures. The yield stress of HT-UPS austenitic stainless steel increased, the ultimate tensile strength decreased, and the total elongation was reduced after sodium exposures at 650°C. The dynamic strain aging effect observed in the as-received HT-UPS specimens became less pronounced after sodium exposures at 650°C. Microstructural characterization of sodium-exposed specimens showed no appreciable surface deterioration or grain structure changes under an optical microscope, except for the H2 G92 steel, in which the martensite structure transformed to large grain ferrite after sodium exposures at 650°C. TEM observations of the sodium-exposed H2 G92 steel showed significant recrystallization after sodium exposure for 2700 h at 550°C, and transformation of martensite to ferrite and high density of precipitates in nearly dislocation-free matrix after sodium exposures at 650°C. Further microstructural analysis and evaluation of decarburization/carburization behavior is needed to understand the dramatic changes in the tensile strengths of advanced ferritic-martensitic and austenitic steels after sodium exposures at 650°C.

36 MATERIALS SCIENCE↗

Neural simulation-based inference of the neutron star equation of state directly from telescope spectra

Neutron stars provide a unique opportunity to study strongly interacting matter under extreme density conditions. The intricacies of matter inside neutron stars and their equation of state are not directly visible, but determine bulk properties, such as mass and radius, which affect the star's thermal X-ray emissions. However, the telescope spectra of these emissions are also affected by the stellar distance, hydrogen column, and effective surface temperature, which are not always well-constrained. Uncertainties on these nuisance parameters must be accounted for when making a robust estimation of the equation of state. In this study, we develop a novel methodology that, for the first time, can infer the full posterior distribution of both the equation of state and nuisance parameters directly from telescope observations. This method relies on the use of neural likelihood estimation, in which normalizing flows use samples of simulated telescope data to learn the likelihood of the neutron star spectra as a function of these parameters, coupled with Hamiltonian Monte Carlo methods to efficiently sample from the corresponding posterior distribution. Our approach surpasses the accuracy of previous methods, improves the interpretability of the results by providing access to the full posterior distribution, and naturally scales to a growing number of neutron star observations expected in the coming years.

79 ASTRONOMY AND ASTROPHYSICS↗

Meteoric fluid infiltration in crustal-scale normal fault systems as indicated by δ 18 O and δ 2 H geochemistry and 40 Ar/ 39 Ar dating of neoformed clays in brittle fault rocks

Both the sources and pathways of fluid circulation are key factors to understanding the evolution of low-angle normal fault (LANF) systems and the distribution of mineral deposits in the upper crust. In recent years, several reports have shown the presence of meteoric waters in mylonitic LANF systems at mid-crustal conditions. However, a mechanism for meteoric water infiltration to these mid-crustal depths is not well understood. Here we report paired δ 18 O and δ 2 H isotopic values from dated, neoformed clays in fault gouge in major detachments of the southwest United States. Furthermore, these isotopic values demonstrate that brittle fault rocks formed from exchange with pristine to weakly evolved meteoric waters at multiple depths along the detachment. 40 Ar/ 39 Ar dating of these same neoformed clays constrains the Pliocene ages of fault-gouge formation in the Death Valley area. The infiltration of ancient meteoric fluids to multiple depths in LANFs indicates that crustal-scale normal fault systems are highly permeable on geologic timescales and that they are conduits for efficient, coupled flow of surface fluids to depths of the brittle-plastic transition.

58 GEOSCIENCES↗

Average Soil Water Retention Curves Measured by Neutron Radiography

Water retention curves are essential for understanding the hydrologic behavior of partially-saturated porous media and modeling flow transport processes within the vadose zone. In this paper we report direct measurements of the main drying and wetting branches of the average water retention function obtained using 2-dimensional neutron radiography. Flint sand columns were saturated with water and then drained under quasi-equilibrium conditions using a hanging water column setup. Digital images (2048 x 2048 pixels) of the transmitted flux of neutrons were acquired at each imposed matric potential (~10-15 matric potential values per experiment) at the NCNR BT-2 neutron imaging beam line. Volumetric water contents were calculated on a pixel by pixel basis using Beer-Lambert s law after taking into account beam hardening and geometric corrections. To remove scattering effects at high water contents the volumetric water contents were normalized (to give relative saturations) by dividing the drying and wetting sequences of images by the images obtained at saturation and satiation, respectively. The resulting pixel values were then averaged and combined with information on the imposed basal matric potentials to give average water retention curves. The average relative saturations obtained by neutron radiography showed an approximate one-to-one relationship with the average values measured volumetrically using the hanging water column setup. There were no significant differences (at p < 0.05) between the parameters of the van Genuchten equation fitted to the average neutron radiography data and those estimated from replicated hanging water column data. Our results indicate that neutron imaging is a very effective tool for quantifying the average water retention curve.

neutron imaging↗

Modeling Contact Angle vs. Temperature for the Quartz-Water-Decane System

Innovative approaches are needed to improve the efficiency of oil recovery technologies to meet the growing demands of fossil-fuel based energy consumption. Enhanced oil recovery (EOR) methods such as low-salinity waterflooding and chemically tuned waterflooding aim to optimize the reservoir’s wetting properties, detaching oil globules from rock surfaces and allowing easier oil flow through pore throats. This wetting behavior is commonly quantified by contact angle measurements of the rock-oil-brine interface, which have been thoroughly investigated and theorized for many systems at ambient temperatures and pressures. However, few studies exist for extending contact angle theories away from ambient conditions. In this paper, we model the contact angles of a quartz-water-decane system at elevated temperatures using the surface tension component (STC) approach. Temperature-dependent van der Waals [Lifshitz-van der Waals (LW)] interactions and hydrogen-bonding (acid-base) interactions were calculated and are incorporated into the model for the quartz-water-decane interface. Additionally, the Hough and White procedure was used to create temperature-dependent dielectric functions of quartz, water, and normal decane for calculations of Hamaker coefficients. Hamaker coefficients calculated this way are highly linear with temperature and agree well with Israelachvili’s approximation. The acid-base interactions likely contribute the most to system wettability changes. Resulting contact angles of the quartz-water-decane system shift from water-wet (16°) to slightly water-wet (57.4°) as temperature increases. The model was also successfully verified for the quartz-air-water system. Our results can be used in future studies to determine optimal injected water compositions for specific rock-oil-brine and other systems with consideration of reservoir temperature.

02 PETROLEUM↗

On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327

Calibration assessment of nuclear plant sensors and transmitters is currently performed through periodic maintenance actions during plant refueling outages. On-line monitoring (OLM) can be used to reduce the time and cost of this maintenance process by using empirical models to evaluate sensor calibration. The implementation of OLM can also mitigate human error associated with unnecessary maintenance on sensors operating within calibration tolerances. OLM has been studied and validated for plants under steady-state baseload operation, but the extension to load-following operation is not well-documented in the literature. Auto-associative kernel regression (AAKR) provides an error-corrected prediction of process sensor measurements for OLM through a weighted average of historic data. The current study evaluates the performance of AAKR for prediction under normal operational transients (such as expected under load-following operation). Performance of the AAKR model with two anomaly detection routines, error uncertainty limit monitoring (EULM) and sequential probability ratio test (SPRT), was evaluated for normal operation, sensor faults, and process degradation. The data used to develop and evaluate the OLM system were collected from a forced flow loop with temperature and flow sensors. Three models of well-correlated groups of sensors are trained to predict normal system behavior under planned transients. The anomaly detection routines are tested for sensor faults and process faults. The results of this experimental study suggest AAKR and an appropriate anomaly detection routine can be applied for sensor calibration and process fault detection under transient operation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HEPA Filter Age Evaluation Report

In 2020, PNNL completed a literature search for high-efficiency particulate air (HEPA) filter age information. HEPA filters are used in many operations to remove particulate matter from effluent exhaust streams. They are thought to degrade over time both during proper storage and during normal operational service; however, the rate at which the filters degrade remains unknown. This brings into question if age is an adequate indicator of HEPA filter performance. Data from six previous reports were obtained from the literature search and combined to create a data set of 1600 operating filters. Filter usage was identified from multiple facilities. The various types of filters (e.g., axial flow, self-contained, and standard 24 x 24 x 11.5 inches; and both separator and separatorless) reported were constructed to the requirements Section FC (HEPA Filters) or Section FK (Special HEPA Filters) of the American Society of Mechanical Engineers AG-1 code. Filters were presumed to have continuously met the operational criteria and in particular passed both annual efficiency tests and annual DP measurements. The environmental conditions within the exhaust system were also assumed adequate for long-term filter operation. The data, by the nature of the reports, excludes rejected filters from quality assurance evaluations, intake, or installation testing. The collective data set shows over half of were operating past the current 10-year Department of Energy (DOE) limit. Data was evaluated for age lifetime using a linear trendline, survival function, probability functions, and failure rate; financial impacts were also addressed. This report supports the notion that HEPA filters can operate safely and efficiently under proper maintenance well past the 10-year lifetime established by DOE. Using the results of the four age evaluation approaches, they collectively point to the reasonableness of an operating HEPA filter lifetime of 20 years. The results are not necessarily definitive, but nevertheless, they are promising. The analysis provides reasonable assurance that when implemented using a graded approach with well-defined performance and operational requirements, extending the service life for HEPA filters beyond 10 years is low risk.

42 ENGINEERING↗

AGR-2 Irradiation Test Final As-Run Report

This document presents the as-run analysis of the AGR-2 irradiation experiment. AGR-2 is the second of the planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the U.S. Department of Energy as part of the Very High Temperature Reactor (VHTR) Technology Development Office (TDO) program. The objectives of the AGR-2 experiment are to: 1. Irradiate UCO (uranium oxycarbide) and UO 2 (uranium dioxide) fuel produced in a large coater. Fuel attributes are based on results obtained from the AGR-1 test and other project activities. 2. Provide irradiated fuel samples for post-irradiation experiment (PIE) and safety testing. 3. Support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. The primary objective of the test was to irradiate both UCO and UO 2 TRISO (tristructural isotropic) fuel produced from prototypic scale equipment to obtain normal operation and accident condition fuel performance data. The UCO compacts were subjected to a range of burnups and temperatures typical of anticipated prismatic reactor service conditions in three capsules. The test train also includes compacts containing UO 2 particles produced independently by the United States, South Africa, and France in three separate capsules. The range of burnups and temperatures in these capsules were typical of anticipated pebble bed reactor service conditions. The results discussed in this report pertain only to U.S.-produced fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Study for Two Phase Flow Instability in the PCHE Type Steam Generator in SMR

Conventional U-tube type heat exchangers have some limitations when applied to Small Modular Reactor (SMRs). In particular, the size of steam generators is important in the SMR, as it greatly affects the size, and thus the cost, of the reactor vessel.. Therefore, the circuit heat exchanger (PCHE) is suggested as an alternative. PCHE, a compact type heat exchanger manufactured by HEATRIC, has several advantages such as the reduced size, wide operation range until 900? and 900 bar and high power density due to the large heat transfer area over volume ratio. Recently, it is newly suggested as an application of a steam generator. MIT and KAIST have already conceptually suggested PCHE as a steam generator. Under boiling condition, flow instability is one of the critical issues-resulting in unstable mass flow rate, sudden temperature change and system control failure. According to the flow mechanism, there are various types of instabilities in the heat exchanger and each flow tendency is different. Typical examples are Ledinegg instability of the static instability and pressure-drop oscillation and density-wave oscillation of the dynamic instability. The characteristic of Ledinegg instability is that the flow under unstable condition changes into the stable flow. The characteristic of dynamic instability is that the flow fluctuates continuously. Pressure-drop oscillation has the period of tens of seconds and the system pressure also highly oscillates with the period of flow instability. In comparison, the density-wave oscillation has the period of few seconds and the system pressure is relatively stable. Previous studies on flow instability are focused on the single channel flow and helical tube type heat exchanger. There has been very limited experimental research on flow instability using PCHE. In KAIST, the test facility was constructed to study the thermal hydraulics in PCHE. The objectives of our test facility are: (1) to identify the occurrence of instability under two phase and super-heated steam flow in PCHE, and (2) to examine whether it can operate normally using throttling effect. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress on the development of new correlations under the framework of the IAEA Coordinated Research Programme on heat transfer in SCWR's

This paper begins with an introduction designed to provide researchers who are new to field of heat transfer to fluids at supercritical pressure with a brief picture of early developments, and to set the scene for the review of work on the development of new correlations for such fluids under the framework of the IAEA CRP. These are needed because of the active consideration now being given to water-cooled nuclear reactors operating at pressures above the critical value. Work on the development of a trans-critical look-up table aimed at covering the region near the critical point is outlined. A very large heat transfer databank has been compiled and subjected to a thorough screening process. It covers a wide range of conditions and has been used for the assessment of the performance of a number of empirical equations. A detailed error analysis was carried out for the most promising ones and an examination of parametric trends was made. A new correlation is described which has been specifically designed to combine simplicity of structure, explicit connection with physically-based phenomena whilst being able to cover both normal and deteriorated heat transfer conditions. It avoids direct dependence of heat transfer coefficient on wall temperature. The performance of this correlation was evaluated using the data set of Herkenrath et al for water at supercritical pressure. Results from a recent experimental study of heat transfer to carbon dioxide at supercritical pressure under conditions of mixed convection have been used to develop a set of equations to describe the general behaviour observed. Comparisons are made between the performance of a number of equations and the data from the carbon dioxide experiments and also some for water. Finally, the development is outlined of physically-based, semi-empirical models aimed at extending an empirical equation for variable property forced convection heat transfer to fluids at supercritical pressure to account for influences of buoyancy and flow acceleration. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗