Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Investigation of the effects of inlet shapes on fan noise radiation

The effect of inlet shape on forward radiated fan tone noise directivities was investigated under experimentally simplified zero flow conditions. Simulated fan tone noise was radiated to the far field through various shaped zero flow inlets. Baseline data were collected for the simplest baffled and unbaffled straight pipe inlets. These data compared well with prediction. The more general inlet shapes tested were the conical, circular, and exponential surfaces of revolution and an asymmetric inlet achieved by cutting a straight pipe inlet at an acute angle. Approximate theories were developed for these general shapes and some comparisons with data are presented. The conical and exponential shapes produced directivities that differed considerably from the baseline data while the circular shape produced directivities similar to the baseline data. The asymmetric inlet produced asymmetric directivities with significant reductions over the straight pipe data for some angles.

Clark, T. L.↗

Energetic ions as remote probes of X type neutral lines in the geomagnetic tail

The study presents a summary of particle orbit signatures of a neutral line in the geomagnetic tail current sheet (CS) as a function of spatial position along the CS boundary layer, as well as within the CS. Six types of CS particle orbits are reviewed: transient B sub z, transient X line, quasi-trapped, trapped, noncrossing X line, and limiting (singular) cases. It is found that for single particle dynamics in a current sheet with neutral line, the phase space ridge is predicted to be found throughout the current sheet if it is not destroyed by collective behavior. An initially tailward flowing distribution causes asymmetries in distributions earthward vs tailward of the neutral line. It is suggested that the chaotic pitch angle scattering may be a dominant mechanism to produce nightside proton isotropy in the auroral zones.

Speiser, T. W.↗

Conjugate heat transfer from a heated disk to a thin liquid film formed by a controlled impinging jet

An experimental and numerical study of the heat transfer from a heated horizontal disk to a thin film of liquid is described. The liquid was delivered to the disk by a collar arrangement such that the film thickness and radial velocity were known at the outer radius of the collar. This method of delivery is termed as a controlled impinging jet. Flow visualization tests were performed and heat transfer data were collected along the radius of the disk for different volumetric flow rates and inlet temperatures in the supercritical and subcritical regions. The heat transfer coefficient was found to increase with flow rate when both supercritical and subcritical regions were present on the heated surface. A numerical simulation of this free surface problem was performed, which included the effects of conjugate heat transfer within the heated disk and the liquid. The numerical predictions agree with the experimental results and show that conjugate heat transfer has a significant effect on the local wail temperature and heat transfer coefficient.

Faghri, A.↗

[Photodissociation of Acetylene and Acetone using Step-Scan Time-Resolved FTIR Emission Spectroscopy]

The photodissociation of acetylene and acetone was investigated as a function of added quenching gas pressures using step-scan time-resolved FTIR emission spectroscopy. Its main components consist of Bruker IFS88, step-scan Fourier Transform Infrared (FTIR) spectrometer coupled to a flow cell equipped with Welsh collection optics. Vibrationally excited C2H radicals were produced from the photodissociation of acetylene in the unfocused experiments. The infrared (IR) emission from these excited C2H radicals was investigated as a function of added argon pressure. Argon quenching rate constants for all C2H emission bands are of the order of 10(exp -13)cc/molecule.sec. Quenching of these radicals by acetylene is efficient, with a rate constant in the range of 10(exp -11) cc/molecule.sec. The relative intensity of the different C2H emission bands did not change with the increasing argon or acetylene pressure. However, the overall IR emission intensity decreased, for example, by more than 50% when the argon partial pressure was raised from 0.2 to 2 Torr at fixed precursor pressure of 160mTorr. These observations provide evidence for the formation of a metastable C2H2 species, which are collisionally quenched by argon or acetylene. Problems encountered in the course of the experimental work are also described.

McLaren, Ian A.↗

Cardiovascular Adaptations to Long Duration Head Down Tilt Bed Rest

Orthostatic hypotension is a recognized risk for crewmembers returning from space. Numerous cardiovascular mechanisms have been proposed to account for this problem including vascular and cardiac dysfunction. We studied arterial and cardiac function in 6-degree head-down tilt bed rest, which is the most widely accepted ground-based analog of spaceflight. Eleven subjects are included in this study (8 men and 3 women). Data analysis was limited to the first 49 days, and compared to pre-bed rest baseline data. Using ultrasound, data was collected on arterial diameters and flows at baseline and during reactive hyperemia and following administration of nitroglycerin. Echocardiography was used to acquire information regarding systolic and diastolic function as well as ventricular mass and diameter. Plasma volumes were significantly decreased by 7 days of bed rest and stayed down through 49 days. There were no differences in reactive hyperemic response in the arm at any time point. However, the hyperemic response in the leg was significantly increased at day 49. Arterial responses to nitroglycerin did not change over the duration of bed rest (day effect) in either the arm or leg, but there was a significant difference between the arm and the leg responses. There was a marked decrease in anterior tibial intimal-medial thickness at days 21, 35 and 49. Several cardiac functional parameters including IVRT, Mitral e-wave, ejection time, velocity of circumferential shortening and myocardial performance index were significantly changed following 49 days of bed rest. These data show that some cardiovascular measures change during bed rest, while others do not. Further study is needed to determine if these measures can provide any insight into the effects of bed rest, or spaceflight, on human cardiovascular performance.

Platts, Steven H.↗

Quantitative Spectral Radiance Measurements in the HYMETS Arc Jet

Calibrated spectral radiance measurements of gaseous emission spectra have been obtained from the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. A fiber-optic coupled spectrometer collected natural luminosity from the flow. Spectral radiance measurements are reported between 340 and 1000 nm. Both Silicon Carbide (SiC) and Phenolic Impregnated Carbon Ablator (PICA) samples were placed in the flow. Test gases studied included a mostly-N2 atmosphere (95% nitrogen, 5% argon), a simulated Earth Air atmosphere (75% nitrogen, 20% oxygen, 5% argon) and a simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon). The bulk enthalpy of the flow was varied as was the location of the measurement. For the intermediate flow enthalpy tested (20 MJ/kg), emission from the Mars simulant gas was about 10 times higher than the Air flow and 15 times higher than the mostly-N2 atmosphere. Shock standoff distances were estimated from the spectral radiance measurements. Within-run, run-to-run and day-to-day repeatability of the emission were studied, with significant variations (15-100%) noted.

Danehy, Paul M.↗

Improved Whole-Blood-Staining Device

Dramatic improvements have been made in NASA s Whole Blood Staining Device (WBSD) since it was last described in "Whole-Blood-Staining Device," NASA Tech Briefs, Vol. 23, No. 10 (October 1999), page 64. The new system has a longer shelf life, a simpler and more effective operational procedure, improved interface with instrumentation, and shorter processing time. More specifically, the improvements have targeted bag and locking clip materials, sampling ports, and air pocket prevention. The WBSD stains whole blood collected during spaceflight for subsequent flow cytometric analysis. In short, the main device stains white blood cells by use of monoclonal antibodies conjugated to various fluorochromes, followed by lysing and fixing of the cells by use of a commercial reagent that has been diluted according to NASA safety standards. This system is compact, robust, and does not require electric power, precise mixing, or precise incubation times. Figure 1 depicts the present improved version for staining applications, which is a poly(tetrafluoroethylene) bag with a Luer-lock port and plastic locking clips. An InterLink (or equivalent) intravenous- injection port screws into the Luer-lock port. The inflatable/collapsible nature of the bag facilitates loading and helps to minimize the amount of air trapped in the fully loaded bag. Some additional uses have been identified for the device beyond whole blood staining. The WBSD has been configured for functional assays that require culture of live cells by housing sterile culture media, mitogens, and fixatives prior to use [Figure 2(a)]. Simple injection of whole blood allows cell-stimulation culture to be performed in reduced gravity conditions, and product stabilization prior to storage, while protecting astronauts from liquid biohazardous materials. Also, the improved WBSD has reconstituted powdered injectable antibiotics by mixing them with diluent liquids [Figure 2(b)]. Although such mixing can readily be performed on Earth by shaking in glass vials, it cannot readily be performed this way in outer space without entraining air bubbles. The present device can be preloaded with the powder and diluent(s) in separate compartments. The powder and diluent( s) can be mixed, without introducing air bubbles, by removing the clip(s), then shaking. This use of the device could also be advantageous in terrestrial applications because it maintains the isolation of the constituents until the time of use.

Sams, Clarence F.↗

Fluorescence-Doped Particles for Simultaneous Temperature and Velocity Imaging

Polystyrene latex microspheres (PSLs) have been used for particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) measurements for several decades. With advances in laser technologies, instrumentation, and data processing, the capability to collect more information about fluid flow beyond velocity is possible using new seed materials. To provide additional measurement capability, PSLs were synthesized with temperature-sensitive fluorescent dyes incorporated within the particle. These multifunctional PSLs would have the greatest impact if they could be used in large scale facilities with minimal modification to the facilities or the existing instrumentation. Consequently, several potential dyes were identified that were amenable to existing laser systems currently utilized in wind tunnels at NASA Langley Research Center as well as other wind and fluid (water) tunnels. PSLs incorporated with Rhodamine B, dichlorofluorescein (DCF, also known as fluorescein 548 or fluorescein 27) and other dyes were synthesized and characterized for morphology and spectral properties. The resulting particles were demonstrated to exhibit fluorescent emission, which would enable determination of both fluid velocity and temperature. They also would allow near-wall velocity measurements whereas laser scatter from surfaces currently prevents near-wall measurements using undoped seed materials. Preliminary results in a wind tunnel facility located at Virginia Polytechnic Institute and State University (Virginia Tech) have verified fluorescent signal detection and temperature sensitivity of fluorophore-doped PSLs.

Danehy, Paul M.↗

Jet-Surface Interaction Noise from High-Aspect Ratio Nozzles: Test Summary

Noise and flow data have been acquired for a 16:1 aspect ratio rectangular nozzle exhausting near a simple surface at the NASA Glenn Research Center as part of an ongoing effort to understand, model, and predict the noise produced by current and future concept aircraft employing a tightly integrated engine airframe designs. The particular concept under consideration in this experiment is a blended-wing-body airframe powered by a series of electric fans exhausting through slot nozzle over an aft deck. The exhaust Mach number and surface length were parametrically varied during the test. Far-field noise data were acquired for all nozzle surface geometries and exhaust flow conditions. Phased-array noise source localization data and in-flow pressure data were also acquired for a subset of the isolated (no surface) and surface configurations; these measurements provide data that have proven useful for modeling the jet-surface interaction noise source and the surface effect on the jet-mixing noise in round jets. A summary of the nozzle surface geometry, flow conditions tested, and data collected are presented.

Propulsion Noise↗

TPSAS-NF1676L-10819-DND

Additional aerodynamic data for the benchmark configuration of partially-dressed cavity-closed nose landing gear (PDCC-NLG), obtained at a flow Mach number of 0.166, are provided in this presentation. A detailed account of the unsteady surface pressure fluctuations acquired with a Kulite transducer designed to be mobile is also given. The roving nature of the transducer allowed the sensor to be placed at numerous locations where high-amplitude pressure fluctuations are expected. The measured surface pressure spectra are mainly broadband in nature, lacking any local peaks associated with coherent vortex shedding. This finding is in agreement with off-surface flow measurements based on particle image velocimetry, which revealed the flow field to be a collection of separated shear layers without any dominant vortex shedding processes.

Mehdi R Khorrami↗

TPSAS-NF1676L-10756-DND

Additional aerodynamic data for the benchmark configuration of partially-dressed cavity-closed nose landing gear (PDCC-NLG), obtained at a flow Mach number of 0.166, are provided in this presentation. A detailed account of the unsteady surface pressure fluctuations acquired with a Kulite transducer designed to be mobile is also given. The roving nature of the transducer allowed the sensor to be placed at numerous locations where high-amplitude pressure fluctuations are expected. The measured surface pressure spectra are mainly broadband in nature, lacking any local peaks associated with coherent vortex shedding. This finding is in agreement with off-surface flow measurements based on particle image velocimetry, which revealed the flow field to be a collection of separated shear layers without any dominant vortex shedding processes.

Mehdi R Khorrami↗

Global Evaluation of Process Conditions and Wave Modes in a Rotating Detonation Engine

Rotating Detonation Engines (RDEs) show significant promise for enhancing the efficiency of gas turbine engines while maintaining low 𝑁𝑂𝑥 emissions. This work investigates the predictability of wave modes in a water-cooled RDE under varying operational conditions. Experimental data comprising over 6,700 samples was collected, including parameters such as flow rates, temperatures, pressures, and equivalence ratios. A machine learning approach using the XGBoost library was used to build a multi-class classifier, predicting wave modes based on these inputs. The model achieved a high accuracy of 97%, demonstrating that wave modes are not random but deterministic based on the process conditions. SHAP analysis was used to identify the most influential parameters affecting wave mode prediction. The results show that for the water-cooled NETL RDE, wave mode is determinant and predictable based on the process parameters.

Weber, Justin [NETL] (ORCID:0000000218487035)↗

Combined aerodynamic and structural dynamic problem emulating routines (CASPER): Theory and implementation

The Combined Aerodynamic and Structural Dynamic Problem Emulating Routines (CASPER) is a collection of data-base modification computer routines that can be used to simulate Navier-Stokes flow through realistic, time-varying internal flow fields. The Navier-Stokes equation used involves calculations in all three dimensions and retains all viscous terms. The only term neglected in the current implementation is gravitation. The solution approach is of an interative, time-marching nature. Calculations are based on Lagrangian aerodynamic elements (aeroelements). It is assumed that the relationships between a particular aeroelement and its five nearest neighbor aeroelements are sufficient to make a valid simulation of Navier-Stokes flow on a small scale and that the collection of all small-scale simulations makes a valid simulation of a large-scale flow. In keeping with these assumptions, it must be noted that CASPER produces an imitation or simulation of Navier-Stokes flow rather than a strict numerical solution of the Navier-Stokes equation. CASPER is written to operate under the Parallel, Asynchronous Executive (PAX), which is described in a separate report.

Jones, William H.↗

Characterization of a platform for the gas transport, collection, and identification of fission products in the high-intensity laser environment

Recent progress in the production of laser accelerated high flux proton beams opens new possibilities for the study of fission in unique environments. To this end, we are currently pursuing the development of a platform for the swift gas transport, collection, and identification of fission products. Fission is induced in targets fixed inside a sealed chamber through which a carrier gas flows, transporting fission products to a carbon filter for collection and online spectroscopy. This has been recently demonstrated using target normal sheath accelerated protons at the PHELIX laser facility. There were large discrepancies between measured rates and those expected based on established fission yields and measured beam parameters. These discrepancies prompted a large number of tests at the Idaho Accelerator Center (IAC), where fission in uranium is induced by bremsstrahlung photons generated by 21 MeV electrons from a linear electron accelerator. Here, the results are compared to a series of models that account for the slowing of energetic fission fragments in the carrier gas and the fluid dynamics of the gas flow that transports fission products to the collection filter. Characterization of the apparatus reveals a few mechanisms that together account for a portion of the previously observed discrepancies at the PHELIX laser facility. However, additional research is necessary before high-accuracy experiments can be performed with the apparatus. Work performed under the auspices of the U.S. Department of Energy by LLNL under contract DE-AC52-07NA27344.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Full-flow fluid filter

Etched-disk filter was developed with fluid passageways in configuration which allows relatively unrestricted flow of fluid and has stagnation areas for collection of impurities. In addition, filter housing without center post was developed to improve flow characteristics.

Toth, L. R.↗

Ground-based measurements of DM-2 rocket exhaust effluents using fixed-flow samplers and electrets

Electret devices were used to collect samples of rocket exhaust products. The samples were analyzed by X-ray spectroscopy. The performance of the electrets was compared with that of Thiokol fixed flow samplers during the static test firing of a solid rocket motor (SRM) demonstration model. A vertical profile of wind speed, wind direction, and air temperature, used as inputs to the multilayer diffusion model for the SRM static test is presented.

Susko, M.↗

Ice Nucleating Particles (INP) Raw Data

The ice nucleation spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice-nucleating particle (INP) number concentrations. It is almost identical to the Colorado State University (CSU) ice spectrometer design. Filter samples are collected at ARM facilities routinely and during intensive operational periods, and on the ARM tethered balloon system operated by Sandia National Laboratories, then processed on the INS at CSU. This filter log contains the detailed metadata at all ARM sites where INP filter sample collection has occurred or is currently ongoing. Metadata include start and end times, vacuum line pressures and temperatures, and flow rates; total accumulated flow through each filter; and notes on collection issues or weather conditions. Users can also keep up to date with the status of filter and data processing, even before data are available on ARM's Data Discovery. Users can contact INP mentors Jessie Creamean or Thomas Hill with any questions.

54 ENVIRONMENTAL SCIENCES↗

Two-Photon Flow Cytometry

Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.

Zhog, Cheng Frank↗