Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIALIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Verification of Transactive Control for Commercial Buildings

Commercial buildings account for a significant portion of electrical energy demand in the United States. Thus, they serve as an ideal target for energy efficiency improvements, which can reduce congestion on the electrical grid and result in lower payments for building owners. One of the proposed approaches to improving energy efficiency in commercial buildings is transactive control, which allows system components to negotiate for resources within a market. The market is designed so that the control objective is met when components consume their allocation of energy. In this paper, a method is proposed to verify that the consumption of market participants matches their allocation. The method regards energy allocations at the beginning of market periods as predictions. Using collected measurements, actual consumption is then estimated at the end of the market period. Agreement between the predicted and estimated use indicates that the system component is behaving as expected. Initial results from the deployment of this verification method in a commercial building are reported, demonstrating the practicality and utility of the method.

Follum, James D.↗

A Data-driven Control Method for Operating the Commercial HVAC Load as a Virtual Battery

Building loads have a great potential to provide ancillary services because of its large power consumption. In order to quantify their flexibility, methods of modeling building loads as virtual battery (VB) have been proposed. The VB model provides an effective way to coordinate building loads and energy storage systems together when providing service to grid. However, after grid send a power signal to VB, the control strategy has not been fully studied to let building consumes this desired amount of power yet. This paper introduces a method to control commercial heating, ventilation, and air conditioning (HVAC) system. First, the thermal model of commercial building is introduced. We then used several data-driven models to approximate this thermal dynamic and the operation of different HVAC components. Base on these data-driven models, we developed a centralized control algorithm to utilize HVAC system consuming the desired amount of power. Finally, we modeled a realistic commercial building in EnergyPlus to test the performance of this proposed control algorithm

Wang, Jiyu↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Transactive Control of Commercial Buildings for Demand Response

Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On Parallelizing Single Dynamic Simulation Using HPC Techniques and APIs of Commercial Software

Time-domain simulations are heavily used in today’s planning and operation practices to assess power system transient stability and post-transient voltage/frequency profiles following severe contingencies to comply with industry standards. Because of the increased modeling complexity, it is several times slower than real time for state-of-the-art commercial packages to complete a dynamic simulation for a large-scale model. With the growing stochastic behavior introduced by emerging technologies, power industry has seen a growing need for performing security assessment in real time. This paper presents a parallel implementation framework to speed up a single dynamic simulation by leveraging the existing stability model library in commercial tools through their application programming interfaces (APIs). Several high performance computing (HPC) techniques are explored such as parallelizing the calculation of generator current injection, identifying fast linear solvers for network solution, and parallelizing data outputs when interacting with APIs in the commercial package, TSAT. The proposed method has been tested on a WECC planning base case with detailed synchronous generator models and exhibits outstanding scalable performance with sufficient accuracy.

Diao, Ruisheng↗

Time allocations across collaborations of academic scientists and their impact on efforts to commercialize novel technologies: is more always better?

We investigate how time spent in different collaborative research arrangements by academic scientists affect their propensity of involvement in the commercialization of novel, university‐originated technologies. Three common collaborative strategies used by academic scientists: (1) internal (within the research group or within the home university) research collaboration; (2) cosmopolitan research collaboration (with scientists in other US or foreign universities); or (3) university–industry research collaboration are assessed. Drawing on the concepts of cognitive and spatial distance, the empirical findings suggest that only one internal research collaboration strategy has a significant impact on the propensity of academic scientists to engage in the commercialization of novel technologies with a private firm; however, this relationship is inverse U shaped. More importantly, academic scientists adopting a university–industry collaboration strategy and spending more research time in such an arrangement have a significantly stronger propensity for being involved in technology commercialization with a private firm; however, this relationship is inverse U shaped as well. We discuss the managerial and policy implications of the findings.

Libaers, Dirk↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Considerations of Alloy N Code Extension for Commercial Molten Salt Reactor Development and Deployment

For commercial development and deployment of the molten salt reactor, a structural alloy that provides both strength at high temperature and resistance to very corrosive molten salt environment is required. To meet this requirement, a survey is conducted on domestic and international candidate alloys. Alloy N turns out to be the sole frontrunner in readiness for qualification to enable the desired deployment within an estimated 10 years. A review of the qualification for commercial nuclear applications indicates that Alloy N has met a large portion of the requirements. Gaps in the qualification are also identified. A search for historical data is underway to retrieve information needed for filling the gaps and upgrading the qualification. Scope of the discovered historical data is briefly discussed and strategic planning for research and development pathway is suggested to ensure successful evolution in commercial deployment of the molten salt reactor system.

Ren, Weiju↗

TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle{sup 3}), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA verification.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-182: Clinical Implementation of TG71-Based Electron MU Calculation and Comparison with a Commercial Secondary Calculation

Purpose: The TG-71 report was published in 2014 to present standardized methodologies for MU calculations and determination of dosimetric quantities. This work explores the clinical implementation of a TG71-based electron MU calculation algorithm and compares it with a recently released commercial secondary calculation program–Mobius3D (Mobius Medical System, LP). Methods: TG-71 electron dosimetry data were acquired, and MU calculations were performed based on the recently published TG-71 report. The formalism in the report for extended SSD using air-gap corrections was used. The dosimetric quantities, such PDD, output factor, and f-air factors were incorporated into an organized databook that facilitates data access and subsequent computation. The Mobius3D program utilizes a pencil beam redefinition algorithm. To verify the accuracy of calculations, five customized rectangular cutouts of different sizes–6×12, 4×12, 6×8, 4×8, 3×6 cm{sup 2}–were made. Calculations were compared to each other and to point dose measurements for electron beams of energy 6, 9, 12, 16, 20 MeV. Each calculation / measurement point was at the depth of maximum dose for each cutout in a 10×10 cm{sup 2} or 15×15cm{sup 2} applicator with SSDs 100cm and 110cm. Validation measurements were made with a CC04 ion chamber in a solid water phantom for electron beams of energy 9 and 16 MeV. Results: Differences between the TG-71 and the commercial system relative to measurements were within 3% for most combinations of electron energy, cutout size, and SSD. A 5.6% difference between the two calculation methods was found only for the 6MeV electron beam with 3×6 cm{sup 2}cutout in the 10×10{sup 2}cm applicator at 110cm SSD. Both the TG-71 and the commercial calculations show good consistency with chamber measurements: for 5 cutouts, <1% difference for 100cm SSD, and 0.5–2.7% for 110cm SSD. Conclusions: Based on comparisons with measurements, a TG71-based computation method and a Mobius3D program produce reasonably accurate MU calculations for electron-beam therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-793: Validation of COMPASS 3D Dosimetry as Pre Treatment Verification with Commercial TPS Algorithms

Purpose: The purpose of this study was to validate the advent of COMPASS 3D dosimetry as a routine pre treatment verification tool with commercially available CMS Monaco and Oncentra Masterplan planning system. Methods: Twenty esophagus patients were selected for this study. All these patients underwent radical VMAT treatment in Elekta Linac and plans were generated in Monaco v5.0 with MonteCarlo(MC) dose calculation algorithm. COMPASS 3D dosimetry comprises an advanced dose calculation algorithm of collapsed cone convolution(CCC). To validate CCC algorithm in COMPASS, The DICOM RT Plans generated using Monaco MC algorithm were transferred to Oncentra Masterplan v4.3 TPS. Only final dose calculations were performed using CCC algorithm with out optimization in Masterplan planning system. It is proven that MC algorithm is an accurate algorithm and obvious that there will be a difference with MC and CCC algorithms. Hence CCC in COMPASS should be validated with other commercially available CCC algorithm. To use the CCC as pretreatment verification tool with reference to MC generated treatment plans, CCC in OMP and CCC in COMPASS were validated using dose volume based indices such as D98, D95 for target volumes and OAR doses. Results: The point doses for open beams were observed <1% with reference to Monaco MC algorithms. Comparisons of CCC(OMP) Vs CCC(COMPASS) showed a mean difference of 1.82%±1.12SD and 1.65%±0.67SD for D98 and D95 respectively for Target coverage. Maximum point dose of −2.15%±0.60SD difference was observed in target volume. The mean lung dose of −2.68%±1.67SD was noticed between OMP and COMPASS. The maximum point doses for spinal cord were −1.82%±0.287SD. Conclusion: In this study, the accuracy of CCC algorithm in COMPASS 3D dosimetry was validated by compared with CCC algorithm in OMP TPS. Dose calculation in COMPASS is feasible within < 2% in comparison with commercially available TPS algorithms.

60 APPLIED LIFE SCIENCES↗

A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signals for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors’ method based on the use of a commercially available color camera is useful to evaluate and understand the display performances of both monochrome and color LCDs in radiology departments.

60 APPLIED LIFE SCIENCES↗

Long term occupancy estimation in a commercial space: an empirical study: poster abstract

Understanding occupancy patterns in a building is very useful to control HVAC systems for improving energy efficiency of the building and occupant comfort. There has been a very little attempt to understand long term occupancy patterns in a commercial space. In this work, we leverage depth sensors (Kinect for XBOX One) to collect occupancy count from an 11,000 square foot commercial space (Bosch office) for nine months. We analyze the collected data and describe key findings that provide deep insights about how a commercial space is used and serve as a guideline to formulate novel and efficient control strategies.

Liu, Kin Sum↗

Commercial Fleet Level Emissions and Energy Tracker (COFLEET) v1.0

This tool generates the latest US commercial vehicle fleet composition and operational characteristics using 2021 US VIUS data and assess the fleetwide energy and emission outcomes. The emission rates for commercial trucks and default fleet composition are collected from the U.S. EPA's MOtor Vehicle Emission Simulator (MOVES4). The 2021 US VIUS data is applied to generate fleet characteristics such as the long-haul fraction and the vehicle mileage accumulation rate. The tool also provides fleet turnover and emission forecasts under various forecasted fleet electrification scenarios. This tool helps policymakers and practitioners advance the commercial fleet generation for emission models. This study also provides some sample datasets for state and local transportation/air quality agencies to test, which can reduce the estimation bias associated with using MOVES default fleets.

Xu, Xiaodan [Lawrence Berkeley National Laboratory↗

CIECAT (Cyber-Informed Engineering Commercial Buildings Analysis Tool) [SWR-25-172]

The Cyber-Informed Engineering Commercial Buildings Analysis Tool (CIECAT) was developed in collaboration with the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This tool is a energy source subcomponent integrated into the CIEMAT ecosystem and is developed to enhance the security and resilience of Commercial Buildings by incorporating Cyber-Informed Engineering (CIE) principles into the Commercial Buildings.

Etigowni, Sriharsha [National Laboratory of the Ro↗

Prospects for commercial production of diatoms

In this paper, a simple procedure that portends the open-pond growth of commercially viable diatoms is discussed. We examined a number of topics relevant to the production and harvesting of diatoms as well as topics concerning the production of bioproducts from diatoms. Among the former topics, we show that it is currently possible to continuously grow diatoms and control the presence of invasive species without chemical toxins at an average annual yield of 132 MT dry diatoms ha -1 over a period of almost 5 years, while maintaining the dominancy of the optimal diatom species on a seasonal basis. The dominant species varies during the year. The production of microalgae is essentially agriculture, but without the ability to control invasive species in the absence of herbicides and insecticides, pollution and production costs would be prohibitive. Among the latter topics are the discussions of whether it is better to produce lipids and then convert them to biofuels or maximize the production of diatom biomass and then convert it to biocrude products using, for example, hydrothermal processes. It is becoming increasingly evident that without massive public support, the commercial production of microalgal biofuels alone will remain elusive. While economically competitive production of biofuels from diatoms will be difficult, when priority is given to multiple high-value products, including wastewater treatment, and when biofuels are considered co-products in a systems approach to commercial production of diatoms, an economically competitive process will become more likely.

09 BIOMASS FUELS↗

Efficacy of commercial recombinant HVT vaccines against a North American clade 2.3.4.4b H5N1 highly pathogenic avian influenza virus in chickens

The outbreak of clade 2.3.4.4b H5 highly pathogenic avian influenza (HPAI) in North America that started in 2021 has increased interest in applying vaccination as a strategy to help control and prevent the disease in poultry. Two commercially available vaccines based on the recombinant herpes virus of turkeys (rHVT) vector were tested against a recent North American clade 2.3.4.4b H5 HPAI virus isolate: A/turkey/Indiana/22-003707-003/2022 H5N1 in specific pathogen free white leghorn (WL) chickens and commercial broiler chickens. One rHVT-H5 vaccine encodes a hemagglutinin (HA) gene designed by the computationally optimized broadly reactive antigen method (COBRA-HVT vaccine). The other encodes an HA gene of a clade 2.2 virus (2.2-HVT vaccine). There was 100% survival of both chicken types COBRA-HVT vaccinated groups and in the 2.2-HVT vaccinated groups there was 94.8% and 90% survival of the WL and broilers respectively. Compared to the 2.2-HVT vaccinated groups, WL in the COBRA-HVT vaccinated group shed significantly lower mean viral titers by the cloacal route and broilers shed significantly lower titers by the oropharyngeal route than broilers. Virus titers detected in oral and cloacal swabs were otherwise similar among both vaccine groups and chicken types. To assess antibody-based tests to identify birds that have been infected after vaccination (DIVA-VI), sera collected after the challenge were tested with enzyme-linked lectin assay-neuraminidase inhibition (ELLA-NI) for N1 neuraminidase antibody detection and by commercial ELISA for detection of antibodies to the NP protein. As early as 7 days post challenge (DPC) 100% of the chickens were positive by ELLA-NI. ELISA was less sensitive with a maximum of 75% positive at 10DPC in broilers vaccinated with 2.2-HVT. Both vaccines provided protection from challenge to both types of chickens and ELLA-NI was sensitive at identifying antibodies to the challenge virus therefore should be evaluated further for DIVA-VI.

60 APPLIED LIFE SCIENCES↗