Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Robotics for HVAC applications: A critical review and future perspectives

Recent advances in artificial intelligence (AI), enhanced computational capabilities, and innovations in sensors and hardware have driven the increasing development and application of robots in heating, ventilation, and air conditioning (HVAC) systems. We selected and reviewed 101 studies published between 2005 and 2025, sourced from IEEE Xplore, Scopus, Web of Science, and the ACM Digital Library. To analyze these works, we developed a five-dimensional analytical framework (morphology, sensing, navigation, task execution, and system integration), inspired by the Springer Handbook of Robotics and tailored specifically for robotic applications in HVAC. Based on the reviewed studies, six distinct tasks spanning the entire HVAC lifecycle have been identified. Among the six tasks, inspection and maintenance dominate (59 %), followed by indoor monitoring and auditing (21 %), whereas leakage detection, comfort support, and installation/retrofit remain less explored. To address the identified gaps, this review proposes future research directions including investigating robot-aware HVAC design principles, developing multimodal HVAC sensing and data fusion techniques, enhancing robot training and hardware capabilities, and expanding robotic applications beyond Maintenance and Operations (M&O). The findings from this review inform future robotics research for HVAC applications and ultimately enhance system affordability, energy efficiency, resilience or reliability, and occupant environmental comfort. Moreover, it seeks to inspire researchers to explore the intersections of robotics, computer science, building science, and HVAC engineering fostering advancements in this multidisciplinary field.

AI↗

Testing and demonstration of model predictive control applied to a radiant slab cooling system in a building test facility

Radiant slab systems have the potential to significantly reduce energy consumption in buildings. However, control of radiant slab systems is challenging. Classical feedback control is inadequate due to the large thermal inertia of the systems and heuristic feed-forward control often leads to unacceptable indoor comfort and may not achieve the full energy savings potential. Model predictive control (MPC) is now attracting increasing interest in the building industry and holds promise for radiant systems. However, an often-cited barrier to its implementation in the building industry is the high computational cost and complexity relative to the feedback controls used in conventional systems. The objectives of this study were to (i) verify the correct operation of an open source MPC toolchain developed for radiant slab systems, and (ii) demonstrate its efficacy in a test facility. A matched pair of cells in the FLEXLAB building test facility at the Lawrence Berkeley National Laboratory was used in the study. The proposed MPC toolchain was implemented in one cell and the performance compared to that of the other cell, which used a conventional heuristic control strategy. Finally, the results showed that the simplified MPC approach applied in the toolchain worked as expected and realized energy savings over the conventional control strategy. The MPC yielded 42% chilled water pump power reduction and 16% cooling thermal energy savings, while maintaining equal or better indoor comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Optimization Platform Based on Coupled Indoor Environment and HVAC Simulation and its Application in Optimal Thermostat Placement

Model-based optimization can help improve the indoor thermal comfort and energy efficiency of Heating, Ventilation and Air Conditioning (HVAC) systems. The models used in previous optimization studies either omit the dynamic interaction between indoor airflow and HVAC or are too slow for model-based optimization. To address this limitation, we propose an optimization methodology using coupled simulation of the airflow and HVAC that captures the dynamics of both systems. We implement an optimization platform using the coupled models of a coarse grid Fast Fluid Dynamics model for indoor airflow and Modelica models for HVAC which is linked to the GenOpt optimization engine. Then, we demonstrate the new optimization platform by studying the optimal thermostat placement in a typical office room with a VAV terminal box in the design phase. After validating the model, we perform an optimization study, in which the VAV terminal box is dynamically controlled, and find that our optimization platform can determine the optimal location of thermostat to achieve either best thermal comfort or least energy consumption, or the combined. Finally, the time cost for performing such optimization study is about 6.2 h, which is acceptable in the design phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power allocation by load aggregator with heterogeneous loads using weighted projection

With the recently increasing adoption of transactive energy markets, the role of a load aggregator is becoming increasingly important. Among the many tasks of an aggregator, the task of managing the electricity consumption among a group of grid-interactive efficient buildings according to the demand on the grid is taken up. Specifically, here, the task of allocating a certain amount of power among the participating customers while respecting their preferences and comfort is considered. Modeling this as an aggregate flexibility, the virtual battery conditions that are employed to verify the feasibility of a candidate power profile are derived. A feasible power profile, when allocated, satisfies specified comfort bands. To determine the ideal power requirement of the loads, the model-free control method is employed. The feasible power profile is allocated by embedding the customers’ preferences through weights, posing the power constraint as a hyperplane, and employing a weighted projection from the ideal power requirements onto the constraint plane to solve the considered task. The proposed method is computationally efficient and scalable to any number of heterogeneous thermostatically controlled loads in buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based predictive control of multi-zone commercial building with a lumped building modelling approach

Here this study investigates the applicability of a lumped building modeling approach to model-based predictive control (MPC) to alleviate the complex modeling process of the grey-box multi-zone building model. Based on experimental data, two building models were estimated in this study. The detailed model as a reference case and a lumped model were estimated with decentralized and conventional approaches, respectively. Then, simulations were performed with two boundary conditions, including the comfort bound and electricity cost structure. The performances of the MPC with the detailed and lumped models were analyzed compared to the feedback control. More savings was achieved with a larger comfort bound and more aggressive electricity cost structure. The savings potential of the proposed lumped model approach was not as high as that of the detailed model. However, the proposed method yields good control performance, whose savings was approximately 8.6% over that of feedback control. These results suggest that the proposed method can be used to facilitate MPC implementation in multi-zone building applications.

42 ENGINEERING↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Bifunctional Asymmetric Fabric with Tailored Thermal Conduction and Radiation for Personal Cooling and Warming

Personal thermal management is emerging as a promising strategy to provide thermal comfort for the human body while conserving energy. By improving control over the heat dissipating from the human body, personal thermal management can provide effective personal cooling and warming. Here, we propose a facile surface modification approach to tailor the thermal conduction and radiation properties based on commercially available fabrics, to realize better management of the whole heat transport pathway from the human body to the ambient. Additionally, a bifunctional asymmetric fabric (BAF) offering both a cooling and a warming effect is demonstrated. Due to the advantages of roughness asymmetry and surface modification, the BAF demonstrates an effective cooling effect through enhanced heat conduction and radiation in the cooling mode; in the warming mode, heat dissipation along both routes is reduced for personal warming. As a result, a 4.6 °C skin temperature difference is measured between the cooling and warming BAF modes, indicating that the thermal comfort zone of the human body can be enlarged with one piece of BAF clothing. We expect this work to present new insights for the design of personal thermal management textiles as well as a novel solution for the facile modification of available fabrics for both personal cooling and warming.

42 ENGINEERING↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture↗

Enhancing the thermosiphon-driven discharge of a latent heat thermal storage system used in a personal cooling device

Personal cooling devices reduce energy loads by allowing buildings to operate with elevated setpoint temperatures, without compromising on the occupant comfort. One such novel technology called the Roving Comforter (RoCo) uses a compact R134a based vapor compression system for cooling. Following its cooling operation, during which waste heat from the condensing refrigerant is stored in a phase change material (PCM), a two-phase loop thermosiphon is used to discharge (solidify) the PCM to enable its next operation. The transient operation of this thermosiphon is the focus of the present paper. Use of a PCM as the storage medium provides high energy density due to the ability to store thermal energy as latent heat during the phase transition; however, the discharge rate is limited by the low thermal conductivity of the PCM. Insertion of a graphite foam within the PCM can increase the rate of discharge and decrease the downtime of the cooling device. Since graphite enhancement involves a tradeoff between improving the discharge time at the expense of PCM volumetric latent heat, the impact of graphite foam density on the PCM discharge rate is investigated by using a Modelica-based transient model of the thermosiphon. The semi-empirical model, which uses relevant heat transfer coefficient and pressure drop correlations for both refrigerant and airside heat transfer, captures the complex phenomena involving simultaneous phase change of the refrigerant and the PCM. Finally, the graphite enhanced PCM selected from this analysis results in a 51% reduction in the discharge time with addition of only 5% to the thermal storage weight, without compromising the required cooling time.

42 ENGINEERING↗

Separate sensible and latent cooling: Carnot limits and system taxonomy

Energy efficiency and thermal comfort can be improved by independent control of temperature and humidity. In recent work, an emerging class of cooling systems known as separate sensible and latent cooling (SSLC) systems have demonstrated 14 to 47% energy savings, while simultaneously providing better comfort control than conventional air conditioning. In this work, SSLC is defined as using two or more cooling processes with unequal sensible heat ratio (SHR) to control temperature and humidity independently and dynamically. Fundamental efficiency limits of SSLC systems are developed for the first time, demonstrating that the Carnot efficiency for SSLC is higher than that of conventional systems. It is revealed that SSLC has particularly high potential for moderate outdoor temperatures, high sensible building loads, and drier indoor conditions. Additionally, this work proposes a classification scheme for SSLC systems, revealing an enormous number of feasible cycle permutations. This provides a framework for the important research task of developing SSLC systems that will save energy, be practical to construct, and be controllable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Prospective Study of Intrafraction Prostate Motion in the Prone vs. Supine Position

Purpose: To prospectively analyze prostate intrafraction motion in the prone vs. supine position and to assess patient satisfaction with these two positions. Methods and Materials: Fifteen prostate cancer patients underwent implantation of five fiducial gold seeds in their prostate for localization. Patients were treated with high-dose-rate brachytherapy to 2,200 cGy followed by intensity-modulated radiation therapy (IMRT) to 5,040 cGy. Patients underwent computed tomography simulation and IMRT in the prone position. For the first five IMRT treatments, an electronic portal imaging system was used to acquire anteroposterior (AP) and lateral images pretreatment and posttreatment. We then repositioned each patient supine and repeated the process, resulting in 600 images. Results: Mean +- standard deviation intrafraction prostate motion was 2.1 +- 1.2 mm and 1.7 +- 1.4 mm (AP, p = 0.47), 2.2 +- 2.0 mm and 1.6 +- 1.8 mm (superoinferior, p = 0.16), and 1.0 +- 1.2 mm and 0.6 +- 0.9 mm (left-right, p = 0.03) in the prone and supine positions, respectively. Eighty percent of patients stated that they were more comfortable in the supine position (p = 0.02). Conclusions: Prone and supine positions resulted in a similar magnitude of AP and superoinferior intrafraction prostate motion (2 mm). Because there was no significant difference in the magnitude of AP and superoinferior prostate motion prone vs. supine and patients were more comfortable in the supine position, patients now undergo IMRT to the prostate and seminal vesicles at our center in the supine position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Oncology Medical Student Clerkship: Implementation and Evaluation of a Bi-institutional Pilot Curriculum

Purpose: To develop and evaluate a structured didactic curriculum to complement clinical experiences during radiation oncology clerkships at 2 academic medical centers. Methods and Materials: A structured didactic curriculum was developed to teach fundamentals of radiation oncology and improve confidence in clinical competence. Curriculum lectures included: (1) an overview of radiation oncology (history, types of treatments, and basic clinic flow); (2) fundamentals of radiation biology and physics; and (3) practical aspects of radiation treatment simulation and planning. In addition, a hands-on dosimetry session taught students fundamentals of treatment planning. The curriculum was implemented at 2 academic departments in 2012. Students completed anonymous evaluations using a Likert scale to rate the usefulness of curriculum components (1 = not at all, 5 = extremely). Likert scores are reported as (median [interquartile range]). Results: Eighteen students completed the curriculum during their 4-week rotation (University of Chicago n=13, Harvard Longwood Campus n=5). All curriculum components were rated as extremely useful: introduction to radiation oncology (5 [4-5]); radiation biology and physics (5 [5-5]); practical aspects of radiation oncology (5 [4-5]); and the treatment planning session (5 [5-5]). Students rated the curriculum as “quite useful” to “extremely useful” (1) to help students understand radiation oncology as a specialty; (2) to increase student comfort with their specialty decision; and (3) to help students with their future transition to a radiation oncology residency. Conclusions: A standardized curriculum for medical students completing a 4-week radiation oncology clerkship was successfully implemented at 2 institutions. The curriculum was favorably reviewed. As a result of completing the curriculum, medical students felt more comfortable with their specialty decision and better prepared to begin radiation oncology residency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗