Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Iodine Speciation Basis and Gap Analysis for Hanford Tank Farm Inventory and during Processing

Pacific Northwest National Laboratory (PNNL) is providing baseline technical support to Washington River Protection Solutions (WRPS) for the One System River Protection Project (RPP) Integrated Flowsheet team. This report documents the evaluation of the technical bases available to support iodine speciation and distribution within Hanford wastes and subsequent waste streams generated during direct feed low-activity waste (DFLAW) pretreatment operations (specifically, waste retrievals and staging, and particle filtration and cesium decontamination using crystalline silicotitanate (CST) ion exchange [in the tank side cesium removal (TSCR) system]. The task performed a literature survey of information related to iodine species in environments analogous to Hanford tank waste and the subsequent waste streams to define a technical basis for the possible iodine speciation in Hanford waste. In doing so it can be determined how likely laboratory studies on iodine speciation in tank waste are to be universally relevant across the Hanford tanks. The task evaluated iodide and iodate as the primary species of interest with a focus on organo-iodine where appropriate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Side Cesium Removal IXC-150 Cask Detonation Report

A set of experiments were conducted at Los Alamos National Laboratory’s firing point 88 to determine the blast pressure and effects of a stoichiometric gas mixture of Hydrogen (H 2 ) and Nitrous Oxide (N 2 O) on the IXC-150 Storage Pad Vent Stack assemblies. The Lab was asked to design, build, and test the vent stack assemblies using a reaction gas volume of 340 in 3 that mimics the Tank Side Cesium Removal (TSCR) Ion Exchange Column (IXC) assembly. The experimental system with vent stack assembly was designed with input from the Washington River Protection Services (WRPS) to ensure an accurate test setup. The tests were conducted at LANL on the newly built filter/gas assembly at the end of April 2021 timeframe, using WRPS supplied vent stack assemblies and internal HEPA filters. The objective of these tests was to observe that the structural integrity of the vent stack assemblies was maintained and determine the resulting blast overpressures at a distance of 16 and 32 inches from the assembly. All work was performed under the LANL Quality Assurance Program (SD330), using a graded application of ASME NQA-1- 2008/NQA-1a-2009. To ensure that all client quality assurance (QA) expectations were addressed, evaluation of the end data needs was performed and the appropriate controls applied for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Temperature Effect of Cesium Exchange onto Crystalline Silicotitanate in AP-107 and AP-105 Hanford Tank Wastes and Two Simulants

Washington River Protection Solutions, LLC (WRPS) is charged with the development of the Tank Side Cesium Removal (TSCR) system to process Hanford tank waste supernates in preparation for vitrification. In addition to a filtration step, TSCR will remove cesium (Cs) using ion exchange columns filled with crystalline silicotitanate (CST) ion exchange media. CST is produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for the TSCR system limits a single column loading to 141,600 Ci 137 Cs. Given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of 596 L (157.5 gal) in a TSCR column, this equates to 0.10 mmole Cs per g CST (Cs distribution coefficient, K d , 1400 mL/g). Factors that influence Cs uptake by CST include (but are not limited to) (1) CST production (lot-to-lot variations), (2) contact temperature, (3) contact duration, (4) competitors in the tank waste feed, (5) anionic composition of the tank waste feed, and (6) the 137 Cs isotopic mass fraction (differs slightly among tank wastes and decreases with time).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank 241-AP-105 Waste at 7 M Na and Equivalent Simulant

Hanford Site nuclear waste is to be vitrified at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection. Hanford tank 241-AP-105 (referred to herein as AP-105) is one of the initial Hanford radioactive tank wastes planned to be processed and vitrified. A portion of AP-105 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL). The waste went through dilution by Columbia River water to reach a target sodium (Na) concentration of 7 M, solids filtration, and cesium removal by ion exchange. A glass composition was calculated from the Kim et al. glass models to satisfy the WTP baseline requirements based on the as-received sample and the target dilution to 7 M, from which a simulant was calculated and glass forming chemical (GFC) additions were determined to form a liquid/solids mixture called melter feed. To prepare for the processing of the 7 M Na AP-105 waste melter feed and learn about the production expectations, the melter feed simulant of 7 M Na AP-105 waste was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spent zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North and South hemispheres is currently supported by a single Mantis rover sample in each hemisphere. A floor scrape sample was obtained from a compact region near the center riser slightly in the South hemisphere and has been analyzed for a shortened list of key analytes. There is not enough additional material from the floor scrape sample material for completing the full suite of constituents. No floor scrape samples have been previously taken from the North hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 19 residual floor material, four additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Three of the four additional samples from each hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape sample results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.

36 MATERIALS SCIENCE↗

Development of ion specific media to treat Sr-contaminated water at Fukushima Daiichi Nuclear Power Plant - 15486

Since April of 2011, Kurion, Inc. contracted with the Tokyo Electric Power Company (TEPCO) to remediate cooling water using Ion Specific Media targeting cesium (Cs). The effluent of the Cs-sorption systems routed into a reverse osmosis (RO) system. While the RO permeate was recirculated into the cooling loop, the RO reject was captured in carbon-steel tanks. However, the cesium-extracted tank water at Fukushima Daiichi also has a high strontium (Sr) activity (∼4 x 10{sup 5} Bq/mL) and needs to be reduced to lower the onsite and boundary doses. To treat this highly contaminated water, Kurion developed the Kurion Mobile Processing System (KMPS). The KMPS uses a powder batch-contact addition step in concert with a series of ion exchange vessels to decontaminate the high Sr-activity water. Kurion tested and developed several ion specific media to treat the water. Several inorganic media were evaluated in the down-select for the system. Equilibrium batch tests, shortened contact time batch tests and column tests were performed to assess the media depending on water conditions. Two media were selected for KMPS: FAS-P (a powdered zeolite) to reduce Ca{sup 2+} and Sr{sup 2+} concentrations and TS-G (a synthetic titanosilicate) to polish the Sr{sup 2+} downstream. The results of these laboratory tests and their performance in the field will be discussed. The operation of the system has led to the continued reduction of dose at the Fukushima Daiichi nuclear power plant. This system and these media can be applied to other difficult wastewater solutions involving high levels of contaminants and salinity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ROTARY FILTER FINES TESTING FOR SMALL COLUMN ION EXCHANGE

SRNL was requested to quantify the amount of 'fines passage' through the 0.5 micron membranes currently used for the rotary microfilter (RMF). Testing was also completed to determine if there is any additional benefit to utilizing a 0.1 micron filter to reduce the amount of fines that could pass through the filter. Quantifying of the amount of fines that passed through the two sets of membranes that were tested was accomplished by analyzing the filtrate by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) for titanium. Even with preparations to isolate the titanium, all samples returned results of less than the instrument's detection limit of 0.184 mg/L. Test results show that the 0.5 micron filters produced a significantly higher flux while showing a negligible difference in filtrate clarity measured by turbidity. The first targeted deployment of the RMF is with the Small Column Ion Exchange (SCIX) at the Savannah River Site (SRS). SCIX uses crystalline silicotitanate (CST) to sorb cesium to decontaminate a clarified salt solution. The passage of fine particles through the filter membranes in sufficient quantities has the potential to impact the downstream facilities. To determine the amount of fines passage, a contract was established with SpinTek Filtration to operate a 3-disk pilot scale unit with prototypic filter disk and various feeds and two different filter disk membranes. SpinTek evaluated a set of the baseline 0.5 micron filter disks as well as a set of 0.1 micron filter disks to determine the amount of fine particles that would pass the membrane and to determine the flux each set produced. The membrane on both disk sets is manufactured by the Pall Corporation (PMM 050). Each set of disks was run with three feed combinations: prototypically ground CST, CST plus monosodium titanate (MST), and CST, MST, plus Sludge Batch 6 (SB6) simulant. Throughout the testing, samples of the filtrate were collected, measured for turbidity, and sent back to SRNL for analysis to quantify the amount of fines that passed through the membrane. It should be noted that even though ground CST was tested, it will be transferred to the Defense Waste Processing Facility (DWPF) feed tank and is not expected to require filtration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alkali metals in beryl and their role in the formation of derivative structural motifs: Comparative crystal chemistry of vorobyevite and pezzottaite

The crystal structures of high-alkali beryl, i.e., vorobyevite Cs{sub 0.08}Na{sub 0.42}(H{sub 2}O){sub 0.18+y} x [Al{sub 2}(Be{sub 2.35}Li{sub 0.65})Si{sub 6}O{sub 18}], (a = 9.2102(14) A, c = 9.2179(14) A, space group P6/mcc, Z = 2, {rho}{sub calcd}= 2.74 g/cm{sup 3}) and pezzottaite Cs{sub 0.75}Na{sub 0.23}(H{sub 2}O){sub 0.24}[Al{sub 2}Be{sub 2}Li(Si{sub 6}O{sub 18})] (a = 15.955(3) A, c = 27.810(8) A, space group, R3-barc, Z = 18, {rho}{sub calcd}= 3.13 g/cm{sup 3}), are determined at a temperature of 100 K. It is confirmed that, at a high lithium content in minerals of the beryl group, lithium is selectively incorporated into Be tetrahedra. The positive charge deficit due to the replacement of Be{sup 2+} cations by Li{sup +} cations is compensated by incorporating large alkali cations into the 'zeolite' channel. It is shown that, when the lithium content becomes close to unity per the corresponding formula, the Li and Be atoms are ordered and the rhombohedral structure of pezzottaite is formed. It is proposed to retain the historical name vorobyevite for the lithium- and cesium-containing variety of beryl with a disordered distribution of Be and Li atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interesting experimental results in Japan Proton Accelerator Research Complex H{sup -} ion-source development (invited)

The following interesting experimental results observed in Japan Proton Accelerator Research Complex (J-PARC) H{sup -} ion-source developments are reviewed. It was proven that almost all of H{sup -} ions were produced with surface reactions in cesium (Cs)-free J-PARC H{sup -} ion-sources. The world's most intense class H{sup -} ion current of 38 mA in Cs-free ion sources for a high-energy linac was attained by an optimal shape and high temperature of the plasma electrode (PE), usage of a lanthanum hexaboride (LaB{sub 6}) filament, and a newly devised high-power constant-current pulsed-arc power supply indispensable for it. It was also proven that the H{sup -} ion current could be increased to more than 40 mA by optimizing LaB{sub 6}-filament shape. The surface elemental analysis of the PE after operation with a LaB{sub 6}-filament showed that it was coated by boron (B) 95.5%, lanthanum (La) 2.5%, and oxygen (O) 1.9%. The H{sup -} ion current decreased by about 20% when a tungsten (W) filament was used instead of a LaB{sub 6}-filament. The H{sup -} ion current could not be increased by seeding cesium (Cs) if the LaB{sub 6}-filament was used. On the other hand, it was increased to more than 70 mA with much lower arc current of 150 A if Cs was seeded when a W-filament was used.

43 PARTICLE ACCELERATORS↗

Tank 9H Salt Solution Supernatant Characterization in Support of Potential Operating Strategies of Tank 9H Supernatant Through the Tank Closure Cesium Removal System

Savannah River Remediation (SRR) recently initiated an ion exchange process to remove radioactive cesium from dissolved salt solution in Tank 10H, known as Tank Closure Cesium Removal (TCCR). As part of that ongoing campaign, the salt in Tank 9H will be dissolved and transferred to Tank 10H for processing through the TCCR system, and SRR requested the characterization of the dissolved salt solution in Tank 9H prior to the transfer to Tank 10H. On July 18, 2019, Savannah River Remediation Engineering (SRR-E) delivered two variable depth Tank 9H salt solution samples, identified as samples HTF-9-19-74 and HTF-9-19-75 (combined total sample volume of about 400 mL) to the Savannah River National Laboratory (SRNL) for characterization. These two Tank 9H variable depth samples (HTF-9-19-74 and HTF-9-19-75 taken at ~180” and 42”, respectively) were retrieved from Riser 7 after hydro-lancing activities were complete. Approximately 4200 gallons of water were added to the tank during this activity. This report presents the analytical characterization results for the Tank 9H salt solution variable depth samples HTF-9-19-74 and HTF-9-19-75 and contains mainly the filtrate analytical results for anions, elements, mass spectral data, total cesium characterization results and select radionuclide results, along with the X-ray diffraction characterization of the solid fractions from the liquid /solid separation of the variable depth salt solutions. Most of these analyses were performed in duplicate with the percent relative standard deviation (%RSD), a measure of the variability between each duplicate data set expressed as a percentage, used to estimate the analytical result quality for each analyte.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure and transport of aqueous electrolytes: From simple halides to radionuclide ions

Molecular simulations are used to compare the structure and dynamics of conventional and radioactive aqueous electrolytes: chloride solutions with sodium, potassium, cesium, calcium, and strontium. The study of Cs{sup +} and Sr{sup 2+} is important because these radioactive ions can be extremely harmful and are often confused by living organisms for K{sup +} and Ca{sup 2+}, respectively. Na{sup +}, Ca{sup 2+}, and Sr{sup 2+} are strongly bonded to their hydration shell because of their large charge density. We find that the water molecules in the first hydration shell around Na{sup +} form hydrogen bonds between each other, whereas molecules in the first hydration shell around Ca{sup 2+} and Sr{sup 2+} predominantly form hydrogen bonds with water molecules in the second shell. In contrast to these three ions, K{sup +} and Cs{sup +} have low charge densities so that they are weakly bonded to their hydration shell. Overall, the structural differences between Ca{sup 2+} and Sr{sup 2+} are small, but the difference between their coordination numbers relative to their surface areas could potentially be used to separate these ions. Moreover, the different decays of the velocity-autocorrelation functions corresponding to these ions indicates that the difference in mass could be used to separate these cations. In this work, we also propose a new definition of the pairing time that is easy to calculate and of physical significance regardless of the problem at hand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Inorganic Microsphere Composite for the Selective Removal of Cesium 137 from Acidic Nuclear Waste Solutions - Parts 1 and 2

A new inorganic ion exchange composite for removing radioactive cesium from acidic waste streams has been developed. The new material consists of ammonium molybdophosphate, (NH4)3P(Mo3O10)4•3H2O (AMP), synthesized within hollow aluminosilicate microspheres (AMP-C), which are produced as a by-product from coal combustion. The selective cesium exchange capacity of this inorganic composite was evaluated in bench-scale column tests using simulated sodium bearing waste solution as a surrogate for the acidic tank waste currently stored at the Idaho National Laboratory (INL). Total cesium loading on the columns at saturation agreed very well with equilibrium values predicted from isotherm experiments performed previously. A numerical algorithm for solving the governing partial differential equations (PDE) for cesium uptake was developed using the intraparticle mass transfer coefficient obtained from previous batch kinetic experiments. Solutions to the governing equations were generated to obtain the cesium concentration at the column effluent as a function of throughput volume using the same conditions as those used for the actual column experiments. The numerical solutions of the PDE fit the column break through data quite well for all the experimental conditions in the study. The model should therefore provide a reliable prediction of column performance at larger scales. A new inorganic ion exchange composite consisting of ammonium molybdophosphate, (NH4)3P(Mo3O10)4•3H2O (AMP), synthesized within hollow aluminosilicate microspheres (AMP-C) has been developed. Two different batches of the sorbent were produced resulting in 20% and 25% AMP loading for two and three loading cycles, respectively. The selective cesium exchange capacity of this inorganic composite was evaluated using simulated sodium bearing waste solution as a surrogate for the acidic tank waste currently stored at the Idaho National Laboratory (INL). Equilibrium isotherms obtained from these experiments were very favorable for cesium uptake and indicated maximum cesium loading of approximately 9 % by weight of dry AMP. Batch kinetic experiments were also performed to obtain the necessary data to estimate the effective diffusion coefficient for cesium in the sorbent particle. These experiments resulted in effective intraparticle cesium diffusivity coefficients of 4.99 x 10-8 cm2/min and 4.72 x 10-8 cm2/min for the 20% and 25 % AMP-C material, respectively.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DEVELOPMENT OF AN APPROACH TO MODELING LOADING AND ELUTION OF SPHERICAL RESORCINOL FORMALDEHYDE ION-EXCHANGE RESIN

The current strategy for removal of cesium from the Hanford waste stream is ion-exchange using spherical Resorcinol-Formaldehyde (sRF) resin. The original resin of choice was granular SuperLig 644 resin and during testing of this resin several operational issues were identified. For example, the granular material had a high angle of internal friction resulting in fragmentation of resin particles along its edges during cycling and adverse hydraulic performance. Efforts to replace SuperLig 644 were undertaken and one candidate was the granular Resorcinol-Formaldehyde (RF) resin where experience with this cation exchanger dates back to the late 1940's. To minimize hydraulic concerns a spherical version of RF was developed and several different chemically produced batches were created. The 5E-370/641 batch of sRF was selected and for the last decade numerous studies have been performed (e.g., batch contact tests, column loading and elution tests). The Waste Treatment Plant (WTP) flowsheet shows that the aqueous phase waste stream will have a wide range of ionic concentrations (e.g., during the loading step 0-3 M free OH, 5+ M Na, 0-1 M K, 0-3 M NO{sub 3}). Several steps are required in the ion-exchange process to achieve the required Cs separation factors: loading, displacement, washing, elution, and regeneration. The sRF resin will be operated over a wide range in pH (i.e., pH of 12-14 during the loading step and pH of 0.01-1 during the elution step). During some of these steps very high levels of counter-ions and co-ions will be present within the aqueous phase. Alternative process feeds are under consideration as well (e.g., sodium levels as high as 8 M and column operation up to 45 C during loading, reduced and recycled HNO{sub 3} during elution). In order to model the performance of sRF resin through an entire ion-exchange cycle, a more robust isotherm model is required. To achieve this more robust isotherm model requires knowledge of the numbers and kinds of fixed ionogenic groups that make up sRF. Recent literature reviews and scoping titration tests strongly indicate that sRF is a polyfunctional cation exchange resin with at least three dominant types of ring groups playing a role in its isotherm behavior over the wide pH range of operations. Also three types of fixed ionogenic acid groups are present: sulfonic (SO{sub 3}H{sup -}) groups; carboxylic (COOH{sup -}) groups, and resorcylic (OH{sup -}) groups. It is this premise that we are working under in the development of a robust isotherm model for sRF over its entire planned pH operating range. The application of prototypic isotherms for modeling ion-exchange column behavior is demonstrated in Section 3 of this report. This preliminary work served to focus the development effort on the use of a mass-action based isotherm. In Section 4 of this report, the foundational material required to develop a robust isotherm model for sRF is provided. The paths taken, and choices made, are given for the reader to better understand our current status with respect to this goal and to highlight our most recent understanding of sRF exchange equilibria. Our ultimate goal is to update the CERMOD code (Aleman and Hamm, 2007) with a robust isotherm model for sRF that spans the entire pH and concentration ranges of planned operations. The isotherm model will then be used in the VERSE-LC code to model an entire ion-exchange cycle.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗