Hypervelocity impact studies using a rotating mirror framing laser shadowgraph camera

The need to study the effects of the impact of micrometeorites and orbital debris on various space-based systems has brought together the technologies of several companies and individuals in order to provide a successful instrumentation package. A light gas gun was employed to accelerate small projectiles to speeds in excess of 7 km/sec. Their impact on various targets is being studied with the help of a specially designed continuous-access rotating-mirror framing camera. The camera provides 80 frames of data at up to 1 x 10 to the 6th frames/sec with exposure times of 20 nsec.

Parker, Vance C.↗

Experience with the UKIRT InSb array camera

The cryogenic infrared camera, IRCAM, has been operating routinely on the 3.8 m UK Infrared Telescope on Mauna Kea, Hawaii for over two years. The camera, which uses a 62x58 element Indium Antimonide array from Santa Barbara Research Center, was designed and built at the Royal Observatory, Edinburgh which operates UKIRT on behalf of the UK Science and Engineering Research Council. Over the past two years at least 60% of the available time on UKIRT has been allocated for IRCAM observations. Described here are some of the properties of this instrument and its detector which influence astronomical performance. Observational techniques and the power of IR arrays with some recent astronomical results are discussed.

Mclean, Ian S.↗

Initial astronomical results with a new 5-14 micron Si:Ga 58x62 DRO array camera

A new array camera system was developed using a 58 x 62 pixel Si:Ga (gallium doped silicon) DRO (direct readout) photoconductor array detector manufactured by Hughes/Santa Barbara Research Center (SBRC). The camera system is a broad band photometer designed for 5 to 14 micron imaging with large ground-based optical telescopes. In a typical application a 10 micron photon flux of about 10(exp 9) photons sec(exp -1) m(exp -2) microns(exp -1) arcsec(exp -2) is incident in the telescope focal plane, while the detector well capacity of these arrays is 10(exp 5) to 10 (exp 6) electrons. However, when the real efficiencies and operating conditions are accounted for, the 2-channel 3596 pixel array operates with about 1/2 full wells at 10 micron and 10% bandwidth with high duty cycle and no real experimental compromises.

Gezari, Dan↗

Geometric database maintenance using CCTV cameras and overlay graphics

An interactive graphics system using closed circuit television (CCTV) cameras for remote verification and maintenance of a geometric world model database has been demonstrated in GE's telerobotics testbed. The database provides geometric models and locations of objects viewed by CCTV cameras and manipulated by telerobots. To update the database, an operator uses the interactive graphics system to superimpose a wireframe line drawing of an object with known dimensions on a live video scene containing that object. The methodology used is multipoint positioning to easily superimpose a wireframe graphic on the CCTV image of an object in the work scene. An enhanced version of GE's interactive graphics system will provide the object designation function for the operator control station of the Jet Propulsion Laboratory's telerobot demonstration system.

Oxenberg, Sheldon C.↗

Search for atmospheric holes with the Viking cameras

Images taken with the two ultraviolet cameras on board the Viking spacecraft were examined for evidence of transient decreases in the near-nadir dayglow. Comparison of near-limb observations of dayglow intensities with those at smaller angles to the nadir with the camera sensitive to O I 130.4 nm emissions supports the existence of transient decreases in the near-nadir dayglow. However, the amount of near-nadir imaging is severely limited and only several significant events are found.

Frank, L. A.↗

Potential applications of MMC and aluminum-lithium alloys in cameras for CRAF spacecraft

In undertaking the design of a 2000-mm focal length camera for the Mariner Mark II series of spacecraft, JPL sought novel materials with the requisite dimensional and thermal stability, outgassing and corrosion resistance, low mass, high stiffness, and moderate cost. Metal-matrix composites and Al-Li alloys have, in addition to excellent mechanical properties and low density, a suitably low coefficient of thermal expansion, high specific stiffness, and good electrical conductivity. The greatest single obstacle to application of these materials to camera structure design is noted to have been the lack of information regarding long-term dimensional stability.

Lane, Marc↗

Thermal analysis of the ultraviolet imager camera and electronics

The Ultraviolet Imaging experiment has undergone design changes that necessiate updating the reduced thermal models (RTM's) for both the Camera and Electronics. In addition, there are several mission scenarios that need to be evaluated in terms of thermal response of the instruments. The impact of these design changes and mission scenarios on the thermal performance of the Camera and Electronics assemblies is discussed.

Dirks, Gregory J.↗

Analysis of a multiple reception model for processing images from the solid-state imaging camera

A detection model to identify the presence of Galileo optical communications from an Earth-based Transmitter (GOPEX) signal by processing multiple signal receptions extracted from the camera images is described. The model decomposes a multi-signal reception camera image into a set of images so that the location of the pixel being illuminated is known a priori and the laser can illuminate only one pixel at each reception instance. Numerical results show that if effects on the pointing error due to atmospheric refraction can be controlled to between 20 to 30 microrad, the beam divergence of the GOPEX laser should be adjusted to be between 30 to 40 microrad when the spacecraft is 30 million km away from Earth. Furthermore, increasing beyond 5 the number of receptions for processing will not produce a significant detection probability advantage.

Yan, T.-Y.↗

Measurement of surface microtopography using helicopter-mounted stereo film cameras and two stereo matching techniques

A common problem in acquiring ground-truth data for use in microwave interaction modeling is the capture of surface roughness data that are both sampled at distances comparable to a fraction of the wavelength and extensive enough to represent the surface statistics in at least one resolution cell of the microwave remote sensor used. A technique has been developed for acquiring the necessary photogrammetric data using twin 70-mm film cameras mounted on a helicopter boom. The apparatus is described, and the accuracy with which ground surface roughness can be characterized using this device is estimated. Both standard and cross-correlation methods were used for data reduction. Stereogrammetry is compared with a completely automated image-matching technique. Dense disparity images were generated from the helicopter stereo pairs. Using interior orientation parameters supplied by the camera manufacturers, and assuming that exterior orientation parameters remain constant between control target and test field photography, an extremely dense DEM (digital elevation model) for a test field has been derived. Results are compared, and accuracy estimates are presented.

Wall, S. D.↗

Strategy for contamination control to improve Wide-Field/Planetary Camera far-ultraviolet performance

A multifaceted contamination control strategy has been developed for the second generated Wide-Field and Planetary Camera (WFPC-2) to improve the FUV stability by several orders of magnitude, compared to the first camera (WFPC-1). The strategy involves: improved on-orbit boil-off capability of the detector optics, added internal shielding and instrument venting, in-process subassembly vacuum bakeout at elevated temperatures, material substitution, sample testing in ultraclean vacuum facility, and internal instrument contamination-transport modeling. A science performance goal of 1 percent photometric accuracy at 1470 A over an extended time (of at least 30 days) has been established as a contamination control target for WFPC-2. The WFPC-2 is currently planned to be launched by the Shuttle in mid-1993 and replace the WFPC-1 which was recently launched with the HST.

Leschly, Kim↗

Gain, Level, And Exposure Control For A Television Camera

Automatic-level-control/automatic-gain-control (ALC/AGC) system for charge-coupled-device (CCD) color television camera prevents over-loading in bright scenes using technique for measuring brightness of scene from red, green, and blue output signals and processing these into adjustments of video amplifiers and iris on camera lens. System faster, does not distort video brightness signals, and built with smaller components.

Major, Geoffrey J.↗

Optical synthesizer for a large quadrant-array CCD camera: Center director's discretionary fund

The objective of this program was to design and develop an optical device, an optical synthesizer, that focuses four contiguous quadrants of a solar image on four spatially separated CCD arrays that are part of a unique CCD camera system. This camera and the optical synthesizer will be part of the new NASA-Marshall Experimental Vector Magnetograph, and instrument developed to measure the Sun's magnetic field as accurately as present technology allows. The tasks undertaken in the program are outlined and the final detailed optical design is presented.

Hagyard, Mona J.↗

An electronic pan/tilt/zoom camera system

A camera system for omnidirectional image viewing applications that provides pan, tilt, zoom, and rotational orientation within a hemispherical field of view (FOV) using no moving parts was developed. The imaging device is based on the effect that from a fisheye lens, which produces a circular image of an entire hemispherical FOV, can be mathematically corrected using high speed electronic circuitry. An incoming fisheye image from any image acquisition source is captured in memory of the device, a transformation is performed for the viewing region of interest and viewing direction, and a corrected image is output as a video image signal for viewing, recording, or analysis. As a result, this device can accomplish the functions of pan, tilt, rotation, and zoom throughout a hemispherical FOV without the need for any mechanical mechanisms. A programmable transformation processor provides flexible control over viewing situations. Multiple images, each with different image magnifications and pan tilt rotation parameters, can be obtained from a single camera. The image transformation device can provide corrected images at frame rates compatible with RS-170 standard video equipment.

Zimmermann, Steve↗

Movable Cameras And Monitors For Viewing Telemanipulator

Three methods proposed to assist operator viewing telemanipulator on video monitor in control station when video image generated by movable video camera in remote workspace of telemanipulator. Monitors rotated or shifted and/or images in them transformed to adjust coordinate systems of scenes visible to operator according to motions of cameras and/or operator's preferences. Reduces operator's workload and probability of error by obviating need for mental transformations of coordinates during operation. Methods applied in outer space, undersea, in nuclear industry, in surgery, in entertainment, and in manufacturing.

Diner, Daniel B.↗

Refinements on the pinhole camera measurements of the LDEF attitude

The results from the University of Alabama in Huntsville (UAH) pinhole camera were reanalyzed to include the effects of corotation of the atmosphere with the Earth as well as satellite oscillation. Previous results from the instrument showed that the satellite had stable attitude offsets in yaw of 8.0 deg and 1.0 deg in pitch; these offsets are unchanged by the present analysis. The primary impact zone of oxygen, i.e., the directly exposed spot on a silver detector, had a ratio of major to minor axes equal to 1.05, which was interpreted as being caused by a small oscillation of plus or minus 0.35 degrees (with precision plus or minus 0.15 degrees). The present analysis shows that the observed effect can largely be accounted for by atmospheric corotation, but that an additional oscillation in yaw of the order of a degree cannot be excluded. The sensitivity of the pinhole camera to satellite oscillations is shown to decrease nonlinearly with decreasing magnitude of the oscillation and to vary inversely with the gas temperature.

Peters, Palmer N.↗

Development and test of an IR camera for astronomical observation at the Palomar 200-in. observatory using the NICMOS II array

A NICMOS II array, a NIR (0.80 - 2.6 micron) imaging system, was integrated into the California Institute of Technology Palomar Observatory camera. The Palomar camera system which consists of six discrete subsystems including a focal plane, an electrical interface, data acquisition electronics, a dewar, dewar optics, and the software is described. The performance and calibration data for each subsystem are presented. Emphasis is placed on test data on the focal plane performance.

Bruce, Carl↗

The explosive transient camera - An automatic, wide-field sky monitor for short-timescale optical transients

The Explosive Transient Camera (ETC) is a widefield sky monitor designed to detect short-timescale (1-l0 s) celestial optical flashes. It consists of two arrays of wide-field CCD cameras monitoring about 0.4 steradian of the night sky for optical transients with risetimes of about 1-10 s and peak magnitudes m(V) of less than about 10. The ETC was designed to be completely automated in order to make year-round observations with minimal human intervention. A small, powerful 68,000-based computer controls all aspects of observations, including roof motion, CCD readouts, and weather sensing: under software control, the ETC is able to perform all the functions of a human observer automatically.

Vanderspek, Roland K.↗

The NASA Electronic Still Camera system

The Electronic Still Camera (ESC) project has been implemented in its first form for space shuttle operations. The system is composed of three components: (1) a hand-held battery-operated fully digital and programmable high-resolution camera; (2) a laptop-computer-based playback/downlink unit for onboard image processing; and (3) a ground station capable of receiving shuttle data, processing images, producing hardcopies, and distributing the data and hardcopies to end users. The advantages of the ESC system over film and satellites are discussed, and system specifications are summarized.