Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Stock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Embodied Carbon Reduction in New Construction: Reference Guide

The U.S. Department of Energy launched the Advanced Building Construction (ABC) Initiative in 2019 to modernize and streamline building renovation and construction processes that facilitate the integration of high-performance and low-carbon solutions in the U.S. building stock. There are four attributes of ABC that are the focus of the Initiative: affordable, fast, appealing, and low carbon. Substantial improvements have been made to reduce operational carbon emissions of buildings through efficiency and electrification. However, to achieve low-carbon new construction buildings, increased efforts to reduce the embodied carbon of buildings are needed. Embodied carbon emissions in buildings come primarily from the manufacturing of building envelope materials such as concrete, steel, lumber, and glass, among others. Recent studies show that construction and renovation of buildings account for 5% of energy use and 10% of carbon emissions globally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Interior Lighting Controls

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization Dilemmas: Deliberating Difficult Decisions in Laboratory Design

Dive into the depths of design and decision-making, while we discuss the decarbonization of laboratory buildings! Delve into the dense domain of laboratory design and operations, where every development presents a diverse array of dilemmas and delights. Join us for these dynamic sessions focused on decoding the secrets of sustainable success. Dig deep into the dynamic world of heat pump designs and the delicate balance of heating and cooling loads. Debate between constant and variable fume hood designs, where these decisions determine outcomes. Discover the divergent paths of HVAC system implementation, from the deployment of chilled beams to the diverse array of different terminal unit types. But don't delay; decisive action is demanded for these goals! Dare to dream of decarbonization as we direct discussions on retrofitting existing building stock versus innovative new design approaches. Delve into the depths of debate and emerge with a decisive strategy for sustainable success. Discuss recent discoveries in development from experts associated with existing laboratory buildings with decarbonization goals. These insights and lessons learned will help determine the path forward in our industry's drive for decarbonization designs. Decarbonization is no easy task, but with determination, dedication, and devotion, we can defy the odds and forge a brighter future for laboratory design and operations. Let's dare to decarbonize together!

decarbonization↗

Achieving 50% Energy Savings in Chicago Homes: A Case Study for Advancing Equity and Climate Goals

Since 2019, the National Renewable Energy Laboratory (NREL) and Elevate have collaborated to identify pathways to deep energy retrofits in Chicago's housing stock, document equity implications and co-benefits of this transition, and validate the findings by implementing retrofits in real Chicago homes. This document summarizes our analysis process to model advanced retrofit packages that lead to greater than 50% energy savings in Chicago homes. Based on these findings, we have also developed a roadmap with the City to guide implementation, and are deploying the recommended retrofit packages in real Chicago homes to realize these energy savings. This work was developed in collaboration with two key stakeholders - the City of Chicago and Commonwealth Edison (ComEd) - and funded by the U.S. Department of Energy (DOE). NREL's Residential Buildings team maintains the best-in-class ResStock™ energy model of the U.S. residential building stock. For this work, we calibrated ResStock to Chicago's unique local housing stock to accurately simulate energy use in Chicago homes both for current conditions and with various retrofit scenarios. We simulated a wide range of potential building retrofits covering all aspects of residential energy use and then grouped these into packages based on energy and utility bill savings. ResStock can model diverse building types and housing characteristics, so we're able to observe the range of outcomes that might occur when these upgrades are deployed across the entire housing stock. We can then estimate potential energy savings from an advanced retrofit program on Chicago's housing stock by comparing the modeled energy use before versus after a retrofit. This novel version of ResStock, calibrated to Chicago with data from Elevate, can help City officials, ComEd, and other partners plan for community-scale decarbonization via residential retrofits. Specifically, this work contributes the following project goals: Develop a building retrofit prioritization strategy for Chicago single-family and 2- to 4-unit buildings; Identify neighborhoods and home types that have the highest potential for savings from electrification; and Assess the impact of advanced building retrofits on energy use, utility bills, and CO2 emissions at the city and building level. Although this study is specific to Chicago, its methods and learnings are applicable across the United States. These findings are especially notable for heat pumps and electrification retrofits in cold climates.

building energy modeling↗

Introduction to ComStock

This presentation is an introduction to ComStock and the datasets it produces. The goal of this work is to help cities, states, utilities, and other stakeholders have information and resources needed to make informed decisions about their building stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban building energy modeling (UBEM) tools: A state-of-the-art review of bottom-up physics-based approaches

Regulations corroborate the importance of retrofitting existing building stocks or constructing new energy-efficient districts. There is, thus, a need for modeling tools to evaluate energy scenarios to better manage and design cities, and numerous methodologies and tools have been developed. Among them, Urban Building Energy Modelling (UBEM) tools allow the energy simulation of buildings at large scales. Choosing an appropriate UBEM tool, balancing the level of complexity, accuracy, usability, and computing needs, remains a challenge for users. The review focuses on the main bottom-up physics-based UBEM tools, comparing them from a user-oriented perspective. Five categories are used: (i) the required inputs, (ii) the reported outputs, (iii) the exploited workflow, (iv) the applicability of each tool, and (v) the potential users. Moreover, a critical discussion is proposed, focusing on interests and trends in research and development. The results highlighted major differences between UBEM tools that must be considered to choose the proper one for an application. Finally, barriers of adoption of UBEM tools include the needs of a standardized ontology, a common three-dimensional city model, a standard procedure to collect data, and a standard set of test cases. This feeds into future development of UBEM tools to support cities’ sustainability goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Paths Forward: Approaches to Achieve Plug and Process Load Efficiency and Control in Commercial Buildings: Preprint

To accomplish net-zero carbon in the built environment by 2050, we must equitably decarbonize commercial buildings, which includes reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not directly associated with major building end uses like lighting and heating, ventilating, and air conditioning. PPLs account for a growing portion of U.S. commercial building energy consumption. Although commercial building PPL strategies and technologies are available today, they have not been adopted at a level sufficient to achieve significant savings and load flexibility across the building stock. In our "Pathways to Plug and Process Load Efficiency and Control" study, we investigated why these technologies and strategies have not seen widespread adoption and identified five behavior and technology pathways to increase PPL reduction in commercial buildings. In this paper, we expand beyond identifying the pathways and discuss approaches for achieving them. We discuss the importance of collecting and sharing data and case studies on PPL energy consumption and savings from control technology implementation, including code-required measures, for increasing adoption. Centralizing case studies and data, engaging industry organizations, and promoting awareness of PPL efficiency benefits to relevant groups are also key approaches. Additionally, funding, incentives, and rebate programs play important roles in driving PPL efficiency and control adoption. Finally, we discuss integrating PPL efficiency into broader company goals, such as environmental, social and governance (ESG) strategies and green building certifications, to further drive adoption.

adoption pathways↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning energy flexibility in buildings

Demand side energy flexibility is increasingly being viewed as an essential enabler for the swift transition to a low-carbon energy system that displaces conventional fossil fuels with renewable energy sources while maintaining, if not improving, the operation of the energy system. Building energy flexibility may address several challenges facing energy systems and electricity consumers as society transitions to a low-carbon energy system characterized by distributed and intermittent energy resources. For example, by changing the timing and amount of building energy consumption through advanced building technologies, electricity demand and supply balance can be improved to enable greater integration of variable renewable energy. Although the benefits of utilizing energy flexibility from the built environment are generally recognized, solutions that reflect diversity in building stocks, customer behavior, and market rules and regulations need to be developed for successful implementation. In this paper, we pose and answer ten questions covering technological, social, commercial, and regulatory aspects to enable the utilization of energy flexibility of buildings in practice. In particular, we provide a critical overview of techniques and methods for quantifying and harnessing energy flexibility. We discuss the concepts of resilience and multi-carrier energy systems and their relation to energy flexibility. We argue the importance of balancing stakeholder engagement and technology deployment. Finally, we highlight the crucial roles of standardization, regulation, and policy in advancing the deployment of energy flexible buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗