Boiling Water Capsule Irradiation Test Device Design Study Report
RELAP5 calculations were conducted to support an experimental design, referred to as water capsule, which can facilitate fuel performance testing within ATR. The main objective is to provide useful insights into the experimental design and operating strategies that can mimic LWR operating conditions within the spatial constraints of the ATR position under consideration. This report summarizes the RELAP5 analysis results based on the most recent water capsule design derived through various tests. To discuss a design under conservative conditions, fuel power is consistently assumed to be 400 W/m in all analyses.