Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Better Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Study Highlights: Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

A recent study of plug load devices in Army buildings has identified opportunities to save over 83 million kWh of electricity valued at over $5 million per year. These savings may be conservative and were identified by inventorying and monitoring plug load and miscellaneous electric load (MEL) equipment within representative Army buildings. The objective was to better understand the energy consumed by these devices and identify approaches for reducing it while enhancing resilience. This summary highlights the findings, lessons learned, and recommendations identified by the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning models for rat multigeneration reproductive toxicity prediction

Reproductive toxicity is one of the prominent endpoints in the risk assessment of environmental and industrial chemicals. Due to the complexity of the reproductive system, traditional reproductive toxicity testing in animals, especially guideline multigeneration reproductive toxicity studies, take a long time and are expensive. Therefore, machine learning, as a promising alternative approach, should be considered when evaluating the reproductive toxicity of chemicals. We curated rat multigeneration reproductive toxicity testing data of 275 chemicals from ToxRefDB (Toxicity Reference Database) and developed predictive models using seven machine learning algorithms (decision tree, decision forest, random forest, k-nearest neighbors, support vector machine, linear discriminant analysis, and logistic regression). A consensus model was built based on the seven individual models. An external validation set was curated from the COSMOS database and the literature. The performances of individual and consensus models were evaluated using 500 iterations of 5-fold cross-validations and the external validation data set. The balanced accuracy of the models ranged from 58% to 65% in the 5-fold cross-validations and 45%–61% in the external validations. Prediction confidence analysis was conducted to provide additional information for more appropriate applications of the developed models. The impact of our findings is in increasing confidence in machine learning models. We demonstrate the importance of using consensus models for harnessing the benefits of multiple machine learning models (i.e., using redundant systems to check validity of outcomes). While we continue to build upon the models to better characterize weak toxicants, there is current utility in saving resources by being able to screen out strong reproductive toxicants before investing in vivo testing. The modeling approach (machine learning models) is offered for assessing the rat multigeneration reproductive toxicity of chemicals. Our results suggest that machine learning may be a promising alternative approach to evaluate the potential reproductive toxicity of chemicals.

consensus model↗

What We Learned From Analyzing 18 Million Rows of Commercial Buildings’ HVAC Fault Data

To achieve ambitious decarbonization goals it is critical that buildings operate to their full potential. Commercial HVAC systems, however, experience a wide range of operational faults, adversely affecting energy consumption, occupant comfort, and maintenance costs. Analytical tools such as fault detection & diagnostics (FDD) software identify and help diagnose these types of sensing, mechanical, or control-related faults. While significant energy savings has been documented for FDD, along with limited-scale studies on technical capabilities, there is a lack of empirical data on faults being reported by FDD tools. With FDD deployment accelerating significantly over the past decade there is an opportunity to gather and analyze data on commercial HVAC operational problems at an unprecedented scale. Such data could address many questions such as: [a] What faults are most commonly reported?; and [b] How does fault reporting vary by time of year and other possible drivers? A recent study into FDD fault reporting amassed the largest U.S. dataset of commercial HVAC air-side fault records, drawn from multi-year monitoring across over 60,000 pieces of HVAC equipment. The results of this study provide granular data on fault reporting for over 90 unique fault types. In this paper we provide an overview of the research process and highlight key findings and lessons learned. This study presents an extraordinary level of detail on FDD fault reporting characteristics across many climate zones and building types. Armed with these new insights, commercial building industry stakeholders can make better informed decisions when designing, configuring, and operating commercial HVAC systems.

Crowe, Eliot↗

Building Science Advisor (BSA): A Tool to Assist in the Design and Education of Durable Envelopes

The moisture durability of a building envelope component can be difficult to predict. It depends on the materials used, the location in the assembly, the macro- and microclimate of the building, the air tightness of the interior environment and construction quality. Modern building codes require more insulation and tighter construction but provide little guidance about how to ensure these energy-efficient assemblies are designed and built to retain moisture durability. Furthermore, as new products are introduced to the market, builders are increasingly uncertain about the long-term durability of their building envelope designs. As building envelopes get tighter and better insulated, moisture management is key to a durable and high-performing wall assembly.

Desjarlais, Andre↗

A review of select human-building interfaces and their relationship to human behavior, energy use and occupant comfort

In recent years, research has emerged to quantitatively and qualitatively understand occupants' interactions with buildings. However, there has been surprisingly little research on building interfaces and how their design, context (e.g., location), and underlying logic impact their usability and occupants’ perceived control, as well as the resulting comfort and energy performance. This means that research is needed to better understand how occupants interact with building interfaces in both commercial and residential applications; both applications are important to address as there are many differences in interface types, level of control and understanding, and even expectations of engagement. Herein, this paper provides a cursory review and discussion of select common building interfaces: windows, window shades/blinds, thermostats, and lighting controls. The goal of this paper is to review literature related to these human-building interfaces to explore interface characteristics, current design and use challenges, and relationships between building interfaces and occupants. Human-building interface interactions are complex, more research is needed to understand design, use, and characteristics. Common themes emerged throughout the literature review to explain occupant interactions (or lack of interactions) with building interfaces, which included thermal and visual comfort, ease and access of control, interface/control placement, poor interface/control design, lack of understanding, and social-behavioral dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Planned Relocation: A Pluralistic and Integrated Approach to Science and Governance

Planned relocation is an ambitious objective that occurs in complex governance settings rife with inequalities of power, discrimination, distrust, deep uncertainty, misalignment of incentives and authorities, and other challenges. Taking planned relocation from ambition to an equitable and effective portfolio of measures will require changes in science, governance and how they work together. Research will need to understand perverse incentives, conflicts, limits to risk perception, and other factors across individuals, communities, governance levels, and sectors. Knowledge to enable planned relocation will emerge not just from technical studies but from entwined processes of action, learning and capacity building. Science and governance must advance their collaboration to better support and learn from these tangled processes to identify adaptive pathways, build agency and implement strategies under deep uncertainty.

global environmental change, adapatation, decision↗

A Roadmap for the Future of Systems Biology in Cancer Research

Cancer systems biology seeks to understand how cancer arises as a system of interconnected molecules, cells, and tissues, with the goal of understanding, predicting, and controlling the disease. In the last decade, the field has rapidly grown as advances in experimental, computational, and analytic technologies have improved our ability to capture and recapitulate the complexities of cancer at multiple scales. However, the field’s promise to understand how specific molecular changes give rise to altered cancer outcomes remains incompletely fulfilled. Fortunately, an opportunity exists to accelerate progress by better coordinating modeling and data-gathering efforts across the cancer systems biology community. This will create the foundation for building accurate, multiscale cancer models that can better predict and identify improved therapeutic interventions. Here, in this study, we outline some of the current challenges in cancer systems biology research, how they can be addressed, and actions that the community can take to accelerate progress in the field.

Modeling & Simulation↗

Making It Happen: On-Site Renewable Energy and Storage Challenges and Solutions for Commercial Buildings: Preprint

The U.S. Department of Energy's (DOE's) Better Climate Challenge invites organizations to partner with DOE to set ambitious, portfolio-wide greenhouse gas (GHG) emissions reduction goals. To better understand the barriers to these goals and to demonstrate successful emissions reduction pathways, organizations can access working groups as one form of technical assistance from leading experts. One working group focus was the use of on-site renewable energy and storage - a key decarbonization strategy after energy efficiency. Members of the Better Climate Challenge onsite renewable energy and storage working group first identified barriers to implementing these technologies. Solutions were then brainstormed to support portfolio building owners to move from single systems to widespread implementation. Example insights include improving understandings of installation processes and location decisions, making the business case to relevant stakeholders, discussing unanticipated challenges throughout the process, and replicating these technologies across portfolios. This paper details valuable market feedback and highlights pathways to move toward widespread deployment of renewable energy and storage solutions.

building decarbonization strategies↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Mertens Unrolled Network (MU-Net): A High Dynamic Range Fusion Neural Network for Through the Windshield Driver Recognition

Face recognition of vehicle occupants through windshields in unconstrained environments poses a number of unique challenges ranging from glare, poor illumination, driver pose and motion blur. In this paper, we further develop the hardware and software components of a custom vehicle imaging system to better overcome these challenges. After the build out of a physical prototype system that performs High Dynamic Range (HDR) imaging, we collect a small dataset of through-windshield image captures of known drivers. We then reformulate the classical Mertens-Kautz-Van Reeth HDR fusion algorithm as a pre-initialized neural network, which we name the Mertens Unrolled Network (MU-Net), for the purpose of fine-tuning the HDR output of through-windshield images. Reconstructed faces from this novel HDR method are then evaluated and compared against other traditional and experimental HDR methods in a pre-trained state-of-the-art (SOTA) facial recognition pipeline, verifying the efficacy of our approach.

Ruby, Max↗

Noble Gas Transport in the MSRE

This study explores the relationship between the physicochemical parameter known as Henry’s gas constant and gas transport across a two-layer film interface. The investigation utilized the Gibbs free energy, incorporating surface and volume terms to elucidate trends in enthalpy and entropy. Notably, our findings align with experimental data and offer predictive insights into the Henry’s gas constants for helium and krypton, which hold significance for future experiments and theoretical developments. Furthermore, this study enhances the Gibbs free energy theory pertaining to the liquid–gas interface. It underscores the substantial contribution of noble gases in this region to volumetric energy as temperature increases. Additionally, we employed Monte Carlo simulations to analyze the effective thermal neutron multiplication factor, denoted as k eff . Our analysis reveals a linear correlation between graphite density and uniform density as a function of temperature. For the 1D Molten Salt Reactor Experiment (MSRE) system, we employed the Mole code to conduct heat and mass transfer calculations. These computations enable us to ascertain the distribution of fuel temperature based on coefficients and thermal properties. We also studied delayed neutron precursors during fuel cycling, taking into account the drift of cycling fuel through Mole–Griffin coupling. Our model represents k eff and β eff across various volume flow rates and salinity compositions. Finally, this study leveraged xenon-135 for continuous on-line monitoring of fuel salts to investigate the impact of steady-state xenon-135 on the MSRE and to better understand its distribution. These efforts build upon previous research related to removal processes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Safe Operations at Roadway Junctions: Intelligent Roadway Infrastructure as Functional Interlocking

Automated vehicle (AV) technology is quickly maturing, and the corresponding infrastructure systems that evaluate traffic and communicate to vehicles requires sophisticated sensing and perception technologies, referred to as intelligent roadway infrastructure (IRI), to complement emerging AV capabilities. IRI provides signals to vehicles, indicating right-of-way for vehicles and communicating to approaching AVs that no other vehicle is failing to yield. This capability, denoted as safety-affirmative signaling, provides a green light or a green arrow as appropriate and affirms through communication links to connected vehicles when it is safe to proceed. About 36% of collisions occur at intersections, with most occurring upon left turns (22.2%) or crossing over (12.6%), and only a small percentage (1.2%) while turning right at an intersection. Of all intersection crashes about half (52.5%) of those vehicles were traveling through a signalized intersection 2. Safety-affirmative signaling would guarantee safety of AV fleet vehicles, by providing the interlocking principle, a term from automated train control that only allows progression through a railway intersection after affirming no opportunity for a crash exists. IRI through safety-affirmative signaling would bring performance and safety to complex roadway intersections where AV transit fleet service is most needed, as well as safety benefits to traditional, non-automated vehicles and vulnerable road users. The implementation of IRI has functional, programmatic, and technical challenges. Research work performed at the National Renewable Energy Laboratory (NREL) in an integrative approach encapsulating these themes, and termed infrastructure perception and control (IPC) is motivated by improved performance (travel time), improved safety (reduced collisions), and improved energy efficiency (less fuel burned and minimized production of greenhouse gases). IPC is intended not only for roadway and intersection applications but also in extension to inform complementary buildings and grid systems to enable better co-management, as vehicles and their charging needs become increasingly integrated into the built environment. The NREL IPC project presents an open-source framework, architecture, and supporting technology to implement IRI, addressing critical issues such as fusion of data, reliability, standardization of data interfaces, and confidence of detection. The framework is informed by previous experience in U.S. Department of Defense research technology, specifically in the use of radar to detect, identify, and track aerial threats. These principles combined with multi-sensor fusion provides for a complete digital twin with known and measurable confidence and accuracy from which safety-affirmative signaling can be developed and deployed.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Lattice Dynamics and Optoelectronic Properties of Vacancy-Ordered Double Perovskite Cs 2 TeX 6 (X = Cl – , Br – , I – ) Single Crystals

The soft, dynamic lattice of inorganic lead halide perovskite CsPbX 3 (X = Cl ⁻ , Br ⁻ , I ⁻ ) leads to the emergence of many interesting photophysical and optoelectronic phenomena. However, probing their lattice dynamics with vibrational spectroscopy remains challenging. The influence of the fundamental octahedral building block in the perovskite lattice can be better resolved in zero-dimensional (0D) vacancy-ordered double perovskites of form A 2 BX 6 . Here we study Cs 2 TeX 6 (X = Cl ⁻ , Br ⁻ , I ⁻ ) single crystals to yield detailed insight into the fundamental octahedral building block and to explore the effect that its isolation in the crystal structure has on structural and electronic properties. The isolated [TeX 6 ] 2- octahedral units serve as the vibrational, absorbing, and emitting centers within the crystal. Serving as the vibrational centers, the isolated octahedra inform the likelihood of a random distribution of 10 octahedral symmetries within the mixed-halide spaces, as well as the presence of strong exciton-phonon coupling and anharmonic lattice dynamics. Serving as the absorbing and emitting centers, the isolated octahedra exhibit compositionally tunable absorption (1.50-3.15 eV) and emission (1.31-2.11 eV) energies. Due to greater molecular orbital overlap between neighboring octahedra with increasing halide anion size, there is a transition from a more molecule-like electronic structure in Cs 2 TeCl 6 and Cs 2 TeBr 6 -as expected from the effective 0D nature of these single crystals-to a dispersive electronic structure in Cs 2 TeI 6 , typical of three-dimensional (3D) bulk single crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗