Three-dimensional simulation of whistler mode excited by the Spacelab 2 electron beam

During the Spacelab 2 mission, while an electron beam was being ejected from the Shuttle, the Plasma Diagnostics Package (PDP) detected a clear funnel-shaped emission that is believed to be caused by whistler-mode emission from the electron beam. In order to understand the mechanism of this emission, simulations with a three-dimensional partially magnetostatic code have been performed. The simulation results show that whistler-mode and lower hybrid waves are excited by the electron beam, which is initially localized in the column in the three-dimensional simulation system, and that they propagate away from the beam. The wave spectra of the electric and magnetic fields diagnosed at some points show several peaks due to the waves excited by the electron beam. The frequency range of these spectra is in qualitative agreement with the PDP data. The intense narrowband electrostatic emission near the electron plasma frequency is observed by the simulations. The simulation results show that the beam instability is responsible for the generation mechanism of these emissions.

Nishikawa, K.-I.↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cascade Models in Simulation of Extended Heavy Targets Irradiated by Accelerated Proton and Deuteron Beams

The paper presents a survey of the main numerical models used for simulation of interaction of accelerated particle beams with target nuclei. These models form the core of the software for simulation of various experiments and experimental facilities both for scientific and applied purposes. The beam and target parameters considered in detail in this study (protons and deuterons with energies from 0.66 to 4 AGeV and bulk U targets) cover the range of interest in development of new concepts of nuclear power production aided by accelerated particle beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First benchmarked electron cooling simulations from first principles

We present the first microscopic electron cooling simulations from first principles with accurate prediction of cooling time. These simulations were performed using our previously developed numerical method, PHAD, which is the first efficient large-scale collisional numerical method in beam physics. The simulation results are benchmarked with the experimental data of the low energy bunched electron cooling of ion beams at the storage ring CSRm at the IMP facility in China. Here, we have accurately considered the nonlinear dynamics in the whole accelerator system in addition to the electron cooling section. As a result, our simulations correctly reproduced cooling times of the experiments from first principles and without any tuning or fitting parameters in the code.

43 PARTICLE ACCELERATORS↗

Low Earth Orbit satellite traffic simulator

This paper describes a significant tool for Low Earth Orbit (LEO) capacity analysis, needed to support marketing, economic, and design analysis, known as a Satellite Traffic Simulator (STS). LEO satellites typically use multiple beams to help achieve the desired communication capacity, but the traffic demand in these beams in usually not uniform. Simulations of dynamic, average, and peak expected demand per beam is a very critical part of the marketing, economic, and design analysis necessary to field a viable LEO system. An STS is described in this paper which can simulate voice, data and FAX traffic carried by LEO satellite beams and Earth Station Gateways. It is applicable world-wide for any LEO satellite constellations operating over any regions. For aeronautical applications to LEO satellites. the anticipates aeronautical traffic (Erlangs for each hour of the day to be simulated) is prepared for geographically defined 'area targets' (each major operational region for the respective aircraft), and used as input to the STS. The STS was designed by Constellations Communications Inc. (CCI) and E-Systems for usage in Brazil in accordance with an ESCA/INPE Statement Of Work, and developed by Analytical Graphics Inc. (AGI) to execute on top of its Satellite Tool Kit (STK) commercial software. The STS simulates constellations of LEO satellite orbits, with input of traffic intensity (Erlangs) for each hour of the day generated from area targets (such as Brazilian States). accumulated in custom LEO satellite beams, and then accumulated in Earth Station Gateways. The STS is a very general simulator which can accommodate: many forms of orbital element and Walker Constellation input; simple beams or any user defined custom beams; and any location of Gateways. The paper describes some of these features, including Manual Mode dynamic graphical display of communication links, to illustrate which Gateway links are accessible and which links are not, at each 'step' of the satellite orbit. In the two Performance Modes, either Channel capacity or Grade Of Service (GOS) for objects (Satellite beams, Gateways, and an entire satellite) are computed respectively by standard traffic table capacity lookup and blocking probability equations. GOS can be input, with number of channels calculated, or number of channels can be input, with GOS calculated. Also described are some of the STS Test Procedure approach and results. AGI plans to make the STS features available through their normal commercial STK products. E-Systems is a co-developer, tester, and user of the STS. The Test Procedure for the STS was prepared by E-Systems, as an independent tester for CCI, to support the CCI delivery of the STS to ESCA, for their customer INPE.

Hoelzel, John↗

On the Bandwidth and Beam Profile Characteristics of a Simple Low-Frequency Collimated Ultrasound Beam Source

We numerically investigate the bandwidth and collimation characteristics of ultrasound beams generated by a simple collimated ultrasound beam source that consists of a piezoelectric disk operated near its radial mode resonances. We simulate the ultrasound beam generated in a fluid medium as a function of the excitation frequency for two cases: (1) free piezoelectric disk that corresponds to zero-traction along the lateral edge and (2) fixed piezoelectric disk that corresponds to zero-displacement along the lateral edge. We present and discuss the physical mechanism underpinning the frequency-dependent collimation and bandwidth properties of the ultrasound beams. We observe that the collimated beam generated by the free disk repeatedly lengthens/shortens and also extends/retracts sidelobes with increasing frequency. Alternatively, fixing the piezoelectric disk results in a consistent beam profile shape across a broad range of frequencies. This facilitates generating broadband signals such as a Gaussian pulse or chirp, which are common in ultrasound imaging. Thus, the fixed piezoelectric disk finds application as a collimated ultrasound beam source in a wide range of applications including medical ultrasound imaging, scanning acoustic microscopy, sonar detection, and other nondestructive ultrasound inspection techniques.

47 OTHER INSTRUMENTATION↗

Optics reconstruction in the SCL section of the FNAL Linac

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 116 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole correctors and measured by 29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings of an upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code TraceWin. A comparison between TraceWin simulations and the beam envelope measured by the 12 wire scanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance and exit of the SCL section will be reported.

Carneiro, Jean-Paul [Fermilab]↗

Experimental investigation of contamination prevention techniques for a cryogenically cooled telescope in earth-orbit

A one-tenth scale model of the Shuttle Infrared Telescope Facility (SIRTF) was constructed to experimentally investigate the feasibility of a helium purge system to reduce contamination on cryogenic surfaces. The on-orbit ambient contaminant environment was simulated with ion beams of N2(+), O(+) and H2O(+). Helium was injected into the model telescope at the simulated plane of the primary optics using two techniques: a) porous plug, b) nozzle. Helium flow rates and telescope pressures were varied to determine the purge effectiveness against potential contaminants. Based on the subscale results, a 90% reduction in O, N2, and H2O at the primary optics of the SIRTF can be obtained using 20 K helium with a pressure of .00001 torr and a flow rate of less than 0.1 g/s.

Hetrick, M. A.↗

Room Temperature Stamping of High-Strength Aluminum for Lightweight Structural Automotive Components

The use of aluminum (Al) 7xxx series in automobile structural applications is limited by factors such as its low room-temperature formability in T6 temper and the need for off-line artificial aging to regain high strength if it is formed in soft temper. In this study, two tempers were established that enable Al 7075 blanks to be room temperature stamped to create side impact beams that achieve near-T6 strength without post-forming artificial aging. It is shown that natural aging at room temperature, after solution treatment and before stamping, provides an alternative to high temperature pre-aging and hot stamping techniques in 7xxx alloys. Both tempers enabled room temperature stamping of the beams without cracking, indicating good formability. The Al beams were ~38% lighter than the benchmark boron steel beam. Further, the hardness in the low-deformation regions of the stamped Al beams were within 88% of a conventional 7075-T6 sheet. Paint-bake treatment of the beams appeared to cause over aging, lowering the ultimate tensile strength and ductility. Finite element three point bending simulations of the beams showed higher bending force and energy absorption before failure for the Al 7075 showing good promise for 7xxx series Al as a light-weight alternative to steel beams.

36 MATERIALS SCIENCE↗

Development of a Platform at the Matter in Extreme Conditions End Station for Characterization of Matter Heated by Intense Laser-Accelerated Protons

High intensity short-pulse lasers have made possible the generation of energetic proton beams, unlocking numerous applications in high energy density science. One such application is uniform and isochoric heating of materials to the warm dense matter (WDM) state. We have developed a new experimental platform to simultaneously create and probe warm dense matter at the Matter in Extreme Conditions (MEC) end station at the Linac Coherent Light Source (LCLS). The short pulse optical laser (delivering up to 1 J in 45 fs) and the ultra-bright LCLS x-ray laser with tunable frequency respectively deliver high power required to heat materials to WDM and precision-timed high-resolution x-rays to probe them. The laser-accelerated proton beam driven from a flat 1.5 μm Cu foil was first measured then directed to a secondary sample of Al or polypropylene, typically 300-400 μm away. The time evolution of the sample electron temperature was measured using streaked optical pyrometry, where we observed a peak temperature of 0.9 0.15 eV on the rear surface of an Al sample heated by the proton beam. Here, the simulations using the hybrid-PIC code LSP and the rad-hydro code HELIOS show that a measured proton beam can heat Al to approximately 4 eV and polypropylene to 1 eV if instead focused by a hemispherical Cu target. Through additional LSP simulations, we anticipate creating hotter warm dense matter states (20 eV) by increasing the laser energy to 10 J and keeping the other laser parameters fixed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optics Reconstruction in the SCL Section of the FNAL Linac

The Side-CoupledLinac (SCL) section oftheFNAL linac acceleratesthe beamfrom 117 MeV to 401.5 MeV, operatingat 22-24mA beam current. Transverse focusing is performedby32 quadrupoles, and the beam orbit is guidedby19dipolecorrectors andmeasuredby29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings o fan upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code Trace Win. A comparison between Trace Win simulations and the beam envelope measured bythe12wirescanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance of the transition section will be reported

Carneiro, Jean-Paul [Fermilab]↗

Temperature effects in plasma-based positron acceleration schemes using electron filaments

Preserving the quality of a positron beam in a plasma-based accelerator, where a wakefield suitable for positron transport and acceleration is generated by means of an electron filament, is challenging. This is due to the nature of the wakefields, characterized by focusing fields that vary nonlinearly in the transverse direction, and by accelerating fields that are non-uniform. These fields also change slice-by-slice along the beam. Maintaining a high beam quality is pivotal for application of positron beams in a plasma-based collider. In this paper, we show that an initial background plasma temperature can help mitigate the positron beam quality degradation in plasma-based accelerators that rely on electron filaments. We show that temperature effects broaden the electron filament and smooth radially both the non-linear transverse and the non-uniform longitudinal wakefields. Using warm plasmas opens up new possibilities to improve beam quality in several plasma-based positron acceleration concepts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micro-beam bending of FCC bicrystals: A comparison between defect dynamics simulations and experiments

To understand the role of the grain boundary (GB) in plasticity at small scale, a concurrently coupled mesoscale plasticity model was developed to simulate micro-bending of bicrystalline micron-sized beams. By coupling dislocation dynamics (DD) with a finite element model (FEM), a novel defect dynamics model provides the means to investigate intricate interactions between dislocations and GBs under various loading conditions. Our simulations of micro-bending agree well with corresponding micro-bending experiments, and they show that mechanical response of bicrystals could have not only hardening but also softening depending on the characters of the GB. In addition, changing the location of the GB in the microbeams results in different mechanical responses; GBs located at the neutral plane show softening compared to single crystals, while inclined GBs located halfway along the length of the beam show little effect. In conclusion, simulation results could provide a clear picture on detailed dislocation-GB interactions, and quantitative resolved shear stress analysis supplemented by dislocation density distribution is used to analyze the mechanical response of bicrystalline samples.

36 MATERIALS SCIENCE↗

Galactic Cosmic Ray Simulation at the NASA Space Radiation Laboratory – 2021 Update

For missions beyond low Earth orbit to the Moon or Mars, astronauts will encounter a complex space radiation field composed of various ion species with a broad range of energies. Such missions pose significant radiation protection challenges that need to be managed to minimize astronaut exposures and associated health risks. An innovative galactic cosmic ray simulator (GCRsim) was recently developed for the NASA Space Radiation Laboratory at Brookhaven National Laboratory. The GCRsim technology is intended to recapitulate major components of the space radiation environment in a ground-analog laboratory setting. It is used for experimental studies to improve the understanding of biological risks and act as a test bed for counter measure development and validation. Currently, the GCRsim consists of 33 energetic ion beams that collectively simulate the primary and secondary GCR field encountered by astronauts over the broad range of particle types, energies, and linear energy transfer (LET) of interest to human health effects. A virtual workshop was held in December 2020 to assess the status of NASA's GCRsim and attendees examined various aspects of simulator design, with an emphasis on beam selection strategies. Modeling approaches, experimental constraints, areas of consensus, and questions of concern were also discussed in detail. An overview of the workshop considerations and discussion for research strategies that are important for future advancements and applications in space radio biology are presented.

Nafisah Khan↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial laser and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C., within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable of focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and man be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

Endothelium Preserving Microwave Treatment for Atherosclerois

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount about 20 C, with the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radical sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C. within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗