Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Characterization of ambient polychlorinated biphenyl background conditions in surface waters of the Pajarito Plateau, New Mexico

Abstract This study presents the development of polychlorinated biphenyl (PCB) background threshold values (BTVs) that statistically characterize ambient background conditions for surface waters in undeveloped and developed landscapes of the Pajarito Plateau in the Rio Grande Basin of New Mexico. Between 2009 and 2018, surface water data were collected at 45 locations under a variety of flow conditions and regimes. A total of 163 samples were collected, with roughly 1/3 of samples and locations being in undeveloped areas (n = 53 from 17 locations), and the remainder being in developed areas (n = 110 from 28 locations). While there are areas on the Pajarito Plateau where PCB point sources are known or likely to have contributed to PCBs in soils, PCB BTVs calculated for undeveloped portions of watersheds (upstream of areas where PCB point sources are known or likely to have contributed to PCBs in soils, and therefore not affected by PCB sources within the watershed) are well above New Mexico's human health organism-only (HH-OO) water quality criterion (0.64 ng/L). Background threshold values are even higher in developed areas upstream of managed soil sites, suggesting that in developed areas, both diffuse ambient PCB sources (e.g., atmospheric deposition) and localized urban sources (e.g., building materials, paints, and electrical equipment) contribute to PCBs in those watersheds. These findings indicate that New Mexico's current HH-OO water quality criterion for PCBs cannot practicably be met due to ambient conditions. It is also impracticable to meet the US Environmental Protection Agency (EPA) criterion continuous concentration (CCC) of 14 ng/L in developed background areas, where the BTV is approximately 1.5 times the CCC. Integr Environ Assess Manag 2023;19:1307–1319. © 2022 SETAC

54 ENVIRONMENTAL SCIENCES↗

Design and construction of a low-background, internal-source proportional counter

Abstract High-purity copper has emerged as a preferred construction material for ultra-low-background HPGe spectrometers and offers excellent bulk radiopurity along with good electrical, thermal, and vacuum properties. Recently, these materials and techniques have been applied to the construction of low-background internal-source gas proportional counters. This work describes the design, construction, and testing of an ultra-low-background internal-source gas proportional counter built primarily of high purity electroformed copper. Energy resolution of *10% FWHM at 59.5 keV has been achieved, a lowenergy threshold of *3 keV has been reached, and gas gain stability over a 4-week period has been demonstrated. Progress toward low-background operation is described.

Electroformed copper↗

Controlling Low-Rate Signal Path Microdischarge for an Ultra-Low-Background Proportional Counter

ABSTRACT Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ~30 meters water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ~1 meter of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.

low noise↗

Triboelectric backgrounds to radio-based polar ultra-high energy neutrino (UHEN) experiments

Here, in the hopes of observing the highest-energy neutrinos (E EeV) populating the Universe, both past (RICE, AURA, ANITA) and current (RNO-G, ARIANNA, ARA and TAROGE-M) polar-sited experiments exploit the impulsive radio emission produced by neutrino interactions. In such experiments, rare single event candidates must be unambiguously identified above backgrounds. Background rejection strategies to date primarily target thermal noise fluctuations and also impulsive radio-frequency signals of anthropogenic origin. In this paper, we consider the possibility that ‘fake’ neutrino signals may also be generated naturally via the ‘triboelectric effect.’ This broadly describes any process in which force applied at a boundary layer results in displacement of surface charge, leading to the production of an electrostatic potential difference V. Wind blowing over granular surfaces such as snow can induce such a potential difference, with subsequent coronal discharge. Discharges over timescales as short as nanoseconds can then lead to radio-frequency emissions at characteristic MHz–GHz frequencies. Using data from various past (RICE, AURA, SATRA, ANITA) and current (RNO-G, ARIANNA and ARA) neutrino experiments, we find evidence for such backgrounds, which are generally characterized by: (a) a threshold wind velocity which likely depends on the experimental trigger criteria and layout; for the experiments considered herein, this value is typically $\mathscr{O}$(10 m/s), (b) frequency spectra generally shifted to the low-end of the frequency regime to which current radio experiments are typically sensitive (100–200 MHz), (c) for the strongest background signals, an apparent preference for discharges from above-surface structures, although the presence of more isotropic, lower amplitude triboelectric discharges cannot be excluded.

Background rejection↗

Modeling of proton-induced radioactivation background in hard X-ray telescopes: Geant4-based simulation and its demonstration by Hitomi ’s measurement in a low Earth orbit

Hard X-ray astronomical observatories in orbit suffer from a significant amount of background due to radioactivation induced by cosmic-ray protons and/or geomagnetically trapped protons. Within the framework of a full Monte Carlo simulation, we present modeling of in-orbit instrumental background which is dominated by radioactivation. To reduce the computation time required by straightforward simulations of delayed emissions from activated isotopes, we insert a semi-analytical calculation that converts production probabilities of radioactive isotopes by interaction of the primary protons into decay rates at measurement time of all secondary isotopes. Therefore, our simulation method is separated into three steps: (1) simulation of isotope production, (2) semi-analytical conversion to decay rates, and (3) simulation of decays of the isotopes at measurement time. This method is verified by a simple setup that has a CdTe semiconductor detector, and shows a 100-fold improvement in efficiency over the straightforward simulation. To demonstrate its experimental performance, the simulation framework was tested against data measured with a CdTe sensor in the Hard X-ray Imager onboard the Hitomi X-ray Astronomy Satellite, which was put into a low Earth orbit with an altitude of 570 km and an inclination of 31°, and thus experienced a large amount of irradiation from geomagnetically trapped protons during its passages through the South Atlantic Anomaly. The simulation is able to treat full histories of the proton irradiation and multiple measurement windows. As a result, the simulation results agree very well with the measured data, showing that the measured background is well described by the combination of proton-induced radioactivation of the CdTe detector itself and thick Bi 4 Ge 3 O 12 scintillator shields, leakage of cosmic X-ray background and albedo gamma-ray radiation, and emissions from naturally contaminated isotopes in the detector system.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Background Attenuation by Sample Matrix in Gamma Spectrometric Analyses

In laboratory gamma spectrometric analyses, the procedures for estimating background usually overestimate it. If an empty container similar to that used to hold samples is measured, it does not consider the background attenuation by sample matrix. If a 'blank' sample is measured, the hypothesis that this sample will be free of radionuclides is generally not true. The activity of this 'blank' sample is frequently sufficient to mask or to overwhelm the effect of attenuation so that the background remains overestimated. In order to overcome this problem, a model was developed to obtain the attenuated background from the spectrum acquired with the empty container. Beyond reasonable hypotheses, the model presumes the knowledge of the linear attenuation coefficient of the samples and its dependence on photon energy and samples densities. An evaluation of the effects of this model on the Lowest Limit of Detection (LLD) is presented for geological samples placed in cylindrical containers that completely cover the top of an HPGe detector that has a 66% relative efficiency. The results are presented for energies in the range of 63 to 2614keV, for sample densities varying from 1.5 to 2.5 g{center_dot}cm{sup -3}, and for the height of the material on the detector of 2 cm and 5 cm. For a sample density of 2.0 g{center_dot}cm{sup -3} and with a 2cm height, the method allowed for a lowering of 3.4% of the LLD for the energy of 1460keV, from {sup 40}K, 3.9% for the energy of 911keV from {sup 228}Ac, 4.5% for the energy of 609keV from {sup 214}Bi, and8.3% for the energy of 92keV from {sup 234}Th. For a sample density of 1.75 g{center_dot}cm{sup -3} and a 5cm height, the method indicates a lowering of 6.5%, 7.4%, 8.3% and 12.9% of the LLD for the same respective energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DESIGN OF A THERMOSIPHON FOR COOLING LOW-BACKGROUND HPGE ARRAYS

ABSTRACT A two-phase nitrogen thermosiphon was developed for the new generation of low-background high-purity germanium (HPGe) arrays. The cooling system for these arrays has to be able to handle the heat load (>20 W) presented by a large detector mass while meeting stringent requirements necessary for low-background systems. The HPGe detector modules should operate as close to liquid nitrogen temperature (<80K) as possible to provide adequate operating conditions for a full range of HPGe impurity concentrations. In addition, exceptional temperature stability (<1 K) is needed to reduce electronic gain shifts due to changes in the front-end electronics operating temperature. In order to meet the background requirements of state-of-the-art systems these arrays are enclosed in passive lead and copper shielding up to 1 m thick. In this paper we present a cooling system for low-background experiments that complies with these stringent geometrical restrictions. Active cooling was integrated via a horizontal thermosiphon that can be fabricated using ultra-pure electroformed copper. It was charged with nitrogen to 434 kPa (63 PSIA) at 292 K, which provided a fill ratio of 10%. The results showed that the thermosiphon can effectively remove in excess of 25 W of heat load.

low-background, thermal conductivity, radiation de↗

Modeling surface backgrounds from radon progeny plate-out

The next generation low-background detectors operating deep underground aim for unprecedented low levels of radioactive backgrounds. The surface deposition and subsequent implantation of radon progeny in detector materials will be a source of energetic background events. We investigate Monte Carlo and model-based simulations to understand the surface implantation profile of radon progeny. Depending on the material and region of interest of a rare event search, these partial energy depositions can be problematic. Motivated by the use of Ge crystals for the detection of neutrinoless double-beta decay, we wish to understand the detector response of surface backgrounds from radon progeny. We look at the simulation of surface decays using a validated implantation distribution based on nuclear recoils and a realistic surface texture. Results of the simulations and measured α spectra are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EXTRAGALACTIC VERY HIGH ENERGY GAMMA-RAY BACKGROUND

We study the origin of the extragalactic diffuse gamma-ray background using the data from the Fermi telescope. To estimate the background level, we count photons at high Galactic latitudes |b| > 60 Degree-Sign . Subtracting photons associated with known sources and the residual cosmic-ray and Galactic diffuse backgrounds, we estimate the extragalactic gamma-ray background (EGB) flux. We find that the spectrum of EGB in the very high energy band above 30 GeV follows the stacked spectrum of BL Lac objects. Large Area Telescope data reveal the positive (1 + z) {sup k}, 1 < k < 4 cosmological evolution of the BL Lac source population consistent with that of their parent population, Fanaroff-Riley type I radio galaxies. We show that EGB at E > 30 GeV could be completely explained by emission from unresolved BL Lac objects if k {approx_equal} 3.

79 ASTRONOMY AND ASTROPHYSICS↗

The unusual smoothness of the extragalactic unresolved radio background

If the radio background is coming from cosmological sources, there should be some amount of clustering due to the large scale structure in the universe. Simple models for the expected clustering combined with the recent measurement by ARCADE-2 of the mean extragalactic temperature lead to predicted clustering levels that are substantially above upper limits from searches for anisotropy on arcminute scales using the Australia Telescope Compact Array and the Very Large Array. The rms temperature variations in the cosmic radio background appear to be more than a factor of 10 smaller (in temperature) than the fluctuations in the cosmic infrared background. It is therefore extremely unlikely that this background comes from galaxies, galaxy clusters, or any sources that trace dark matter halos at z ≲ 5, unless typical sources are smooth on arcminute scales, requiring typical sizes of several Mpc.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MYSTERY OF THE COSMIC DIFFUSE ULTRAVIOLET BACKGROUND RADIATION

The diffuse cosmic background radiation in the Galaxy Evolution Explorer far-ultraviolet (FUV, 1300-1700 Å) is deduced to originate only partially in the dust-scattered radiation of FUV-emitting stars: the source of a substantial fraction of the FUV background radiation remains a mystery. The radiation is remarkably uniform at both far northern and far southern Galactic latitudes and increases toward lower Galactic latitudes at all Galactic longitudes. We examine speculation that this might be due to interaction of the dark matter with the nuclei of the interstellar medium, but we are unable to point to a plausible mechanism for an effective interaction. We also explore the possibility that we are seeing radiation from bright FUV-emitting stars scattering from a ''second population'' of interstellar grains—grains that are small compared with FUV wavelengths. Such grains are known to exist, and they scatter with very high albedo, with an isotropic scattering pattern. However, comparison with the observed distribution (deduced from their 100 μm emission) of grains at high Galactic latitudes shows no correlation between the grains' location and the observed FUV emission. Our modeling of the FUV scattering by small grains also shows that there must be remarkably few such ''smaller'' grains at high Galactic latitudes, both north and south; this likely means simply that there is very little interstellar dust of any kind at the Galactic poles, in agreement with Perry and Johnston. We also review our limited knowledge of the cosmic diffuse background at ultraviolet wavelengths shortward of Lyα—it could be that our ''second component'' of the diffuse FUV background persists shortward of the Lyman limit and is the cause of the reionization of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-ray background anisotropy from Galactic dark matter substructure

Dark matter annihilation in Galactic substructure will imprint characteristic angular signatures on the all-sky map of the diffuse gamma-ray background. We study the gamma-ray background anisotropy due to the subhalos and discuss detectability at the Fermi Gamma-ray Space Telescope. In contrast to earlier work that relies on simulated all-sky maps, we derive analytic formulae that enable to directly compute the angular power spectrum, given parameters of subhalos such as mass function, and radial profile of gamma-ray luminosity. As our fiducial subhalo models, we adopt M{sup -1.9} mass spectrum, subhalos radial distribution suppressed toward the Galactic center, and luminosity profile of each subhalo dominated by its smooth component. We find that, for multipole regime corresponding to {theta} < or approx. 5 deg., the angular power spectrum is dominated by a noiselike term, with suppression due to internal structure of relevant subhalos. If the mass spectrum extends down to Earth-mass scale, then the subhalos would be detected in the anisotropy with Fermi at angular scales of {approx}10 deg., if their contribution to the gamma-ray background is larger than {approx}20%. If the minimum mass is around 10{sup 4}M{sub {center_dot}}, on the other hand, the relevant angular scale for detection is {approx}1 deg., and the anisotropy detection requires that the subhalo contribution to the gamma-ray background intensity is only {approx}4%. These can be achieved with a modest boost for particle-physics parameters. We also find that the anisotropy analysis could be a more sensitive probe for the subhalos than individual detection. We also study dependence on model parameters, where we reach the similar conclusions for all the models investigated. The analytic approach should be very useful when Fermi data are analyzed, and the obtained angular power spectrum is interpreted in terms of subhalo models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Anatomical background and generalized detectability in tomosynthesis and cone-beam CT

Purpose: Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background ''noise'' in cascaded systems analysis of 2D and 3D imaging performance to yield ''generalized'' metrics of noise-equivalent quanta (NEQ) and detectability index as a function of the orbital extent of the (circular arc) source-detector orbit. Methods: A physical phantom was designed based on principles of fractal self-similarity to exhibit power-law spectral density ({kappa}/f{sup {beta}}) comparable to various anatomical sites (e.g., breast and lung). Background power spectra [S{sub B}(f)] were computed as a function of source-detector orbital extent, including tomosynthesis ({approx}10 deg. - 180 deg.) and CBCT (180 deg. +fan to 360 deg.) under two acquisition schemes: (1) Constant angular separation between projections (variable dose) and (2) constant total number of projections (constant dose). The resulting S{sub B} was incorporated in the generalized NEQ, and detectability index was computed from 3D cascaded systems analysis for a variety of imaging tasks. Results: The phantom yielded power-law spectra within the expected spatial frequency range, quantifying the dependence of clutter magnitude ({kappa}) and correlation ({beta}) with increasing tomosynthesis angle. Incorporation of S{sub B} in the 3D NEQ provided a useful framework for analyzing the tradeoffs among anatomical, quantum, and electronic noise with dose and orbital extent. Distinct implications are posed for breast and chest tomosynthesis imaging system design--applications varying significantly in {kappa} and {beta}, and imaging task and, therefore, in optimal selection of orbital extent, number of projections, and dose. For example, low-frequency tasks (e.g., soft-tissue masses or nodules) tend to benefit from larger orbital extent and more fully 3D tomographic imaging, whereas high-frequency tasks (e.g., microcalcifications) require careful, application-specific selection of orbital extent and number of projections to minimize negative effects of quantum and electronic noise. Conclusions: The complex tradeoffs among anatomical background, quantum noise, and electronic noise in projection imaging, tomosynthesis, and CBCT can be described by generalized cascaded systems analysis, providing a useful framework for system design and optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FCC-ee interaction region backgrounds

The FCC-ee machine induced backgrounds on the two proposed detectors (CLD and IDEA) have been studied in detail. Synchrotron Radiation (SR) considerations dictate the Interaction Region (IR) optimization. An asymmetric IR design limits the final bend critical energy to 100 keV. Masks placed before the final focus quadrupole protect the detector from direct hits, and a shield placed around the beam pipe from secondary particles, keeping the effect of SR on the detector to negligible levels. The most important source of background is expected to be the Incoherent Pair Creation (IPC). Its effect has been studied in full simulation and reconstruction, and it was shown that it will not pose a problem for the detector, even if conservative estimations for the time resolution of the detector sensors are assumed. Moreover, the γγ → hadrons, radiative Bhabhas and beam-gas interaction induced backgrounds were studied. All were found to have small to negligible effect on the detector. Finally overall, the FCC–ee interaction region backgrounds are not expected to compromise the detector performance.

47 OTHER INSTRUMENTATION↗

Rain-Induced Increase in Background Radiation Detected by Radiation Portal Monitors

A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to detect the illicit movement of nuclear material. In the present work, transient increases in gamma ray counting rates in RPMs due to rain are investigated. The increase in background activity associated with rain, which has been well documented in the field of environmental radioactivity, originates from the atmospheric deposition of two radioactive daughters of radon-222, namely lead-214 and bismuth-214 (henceforth {sup 222}Rn, {sup 214}Pb and {sup 214}Bi). In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and High Purity Germanium spectra. The data verifies these radionuclides are responsible for the dominant transient natural background fluctuations in RPMs. Effects on system performance and potential mitigation strategies are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Aperture "Photon Bucket" Optical Receiver Performance in High Background Environments

The potential development of large aperture groundbased "photon bucket" optical receivers for deep space communications, with acceptable performance even when pointing close to the sun, is receiving considerable attention. Sunlight scattered by the atmosphere becomes significant at micron wavelengths when pointing to a few degrees from the sun, even with the narrowest bandwidth optical filters. In addition, high quality optical apertures in the 10-30 meter range are costly and difficult to build with accurate surfaces to ensure narrow fields-of-view (FOV). One approach currently under consideration is to polish the aluminum reflector panels of large 34-meter microwave antennas to high reflectance, and accept the relatively large FOV generated by state-of-the-art polished aluminum panels with rms surface accuracies on the order of a few microns, corresponding to several-hundred micro-radian FOV, hence generating centimeter-diameter focused spots at the Cassegrain focus of 34-meter antennas. Assuming pulse-position modulation (PPM) and Poisson-distributed photon-counting detection, a "polished panel" photon-bucket receiver with large FOV will collect hundreds of background photons per PPM slot, along with comparable signal photons due to its large aperture. It is demonstrated that communications performance in terms of PPM symbol-error probability in high-background high-signal environments depends more strongly on signal than on background photons, implying that large increases in background energy can be compensated by a disproportionally small increase in signal energy. This surprising result suggests that large optical apertures with relatively poor surface quality may nevertheless provide acceptable performance for deep-space optical communications, potentially enabling the construction of cost-effective hybrid RF/optical receivers in the future.

photon bucket detection↗

Removing Background Noise with Phased Array Signal Processing

Preliminary results are presented from a test conducted to determine how well microphone phased array processing software could pull an acoustic signal out of background noise. The array consisted of 24 microphones in an aerodynamic fairing designed to be mounted in-flow. The processing was conducted using Functional Beam forming software developed by Optinav combined with cross spectral matrix subtraction. The test was conducted in the free-jet of the Nozzle Acoustic Test Rig at NASA GRC. The background noise was produced by the interaction of the free-jet flow with the solid surfaces in the flow. The acoustic signals were produced by acoustic drivers. The results show that the phased array processing was able to pull the acoustic signal out of the background noise provided the signal was no more than 20 dB below the background noise level measured using a conventional single microphone equipped with an aerodynamic forebody.

Background Noise↗