Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

BEAM Technology Flight Demonstration

As technologies advance, their growing complexity makes them harder to maintain. Detection methods for isolating and identifying impending problems are needed to balance this complexity. Through comparison of signal pairs from onboard sensors, the Beacon-based Exception Analysis For Multimissions (BEAM) algorithm can identify and help classify deviations in system operation from a data-trained statistical model. The goal of this task is to mature BEAM and validate its performance on a flying test bed. A series of F-18 flight demonstrations with BEAM monitoring engine parameters in real time was used to demonstrate in-the-field readiness. Captured F-18 and simulated F-18 engine data were used in model creation and training. The algorithm was then ported to the embedded system with a data buffering, file writing, and data-time-stamp monitoring shell to reduce the impact of embedded system faults on BEAM'S ability to correctly identify engine faults. Embedded system testing identified hardware related restrictions and contributed to iterative improvements in the code's runtime performance. The system was flown with forced engine flameouts and other pilot induced faults to simulate operation out of the norm. Successful detection of these faults, confirmed through post-flight data analysis, helped BEAM achieve TRL6.

Wang, David↗

A Study of Statistical Errors in MICE

The Muon Ionization Cooling Experiment (MICE) will measure ionization cooling from a beam of muons at the Rutherford Appleton Laboratory in the UK. The aim of MICE is to measure a fractional drop in emittance, due to ionization cooling, of order 10% for a range of emittances and momenta, to an accuracy of 1%. A greater understanding of the statistical (as well as systematic) errors on emittance measurement in MICE is paramount to meeting this goal.This paper describes a study aimed at exploiting the computing power of the Grid to determine the number of muons necessary to meet the scientific goals of MICE. In this study, tens of thousands of G4MICE Monte Carlo simulations were run to determine the scaling laws that govern the fractional change in emittance as a function of the number of muons (N) in the simulation. By varying random conditions, the standard deviation of these distributions was studied as a function of N. The results of the study indicate that, due to the effect of correlations, of order 10{sup 5} muons are required to meet the goal of MICE for large emittance beams, without which 10{sup 6} would be required.

43 PARTICLE ACCELERATORS↗

Precision Electron Beam Polarimetry

Measurements at future electron accelerators will require unprecedented precision in the determination of electron beam polarization. Existing and novel electron beam polarization measurement schemes are examined, and ideas are being presented of how to to achieve sub-1% precision in polarization determination.

43 PARTICLE ACCELERATORS↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Novel 4{pi} Detection System for the Measurement of the {sup 6}Li(n,{alpha}){sup 3}H Reaction Cross Section

A dedicated one-dimensional Time Projection Chamber (1D-TPC) was designed and produced at IRMM to determine the {sup 6}Li(n,{alpha}){sup 3}H cross section in the 0.4-2.8 MeV energy range, aiming at 5% accuracy. The basic TPC components were a twin gridded ionisation chamber (GIC) with interwired electrodes and fast digitisation of the anode and cathode signals. The energy of both reaction products emitted from a thin {sup 6}LiF sample at the common TPC cathode was measured. A Kr(97%)CO{sub 2}(3%) mixture was used as the detector gas at a pressure up to 3.5 bar. A {sup 238}U sample mounted on the cathode of an ionisation chamber without grid was used as the neutron flux monitor. Special care was taken to reduce the experimental sources of uncertainty. The beam-monitor {sup 238}U sample was characterised at IRMM by low-geometry {alpha}-counting with an accuracy of 0.1%. A {sup 6}Li sample was produced at IRMM by vacuum evaporation of {sup 6}LiF onto transparent aluminium backing. The number of {sup 6}Li atoms will be measured via Thermal Neutron Depth Profiling with an expected accuracy of 2% with respect to an IRMM Standard Reference Material. First test measurements were performed using a monoenergetic neutron beam produced by the T(p,n){sup 3}He reaction at the IRMM 7 MV Van de Graaff accelerator. The experimental method and preliminary results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization Upgrade at ELSA

The Electron Stretcher Accelerator ELSA at Bonn University is a fast ramping stretcher ring supplying a polarized electron beam of up to 3.5 GeV to hadron physics experiments. During acceleration (4.5 GeV/sec), sophisticated schemes for the compensation of depolarizing resonances are mandatory, such as betatron tune jumps for intrinsic resonances and harmonic closed orbit corrections for imperfection resonances. This contribution will present recently implemented techniques of dynamic closed orbit correction as well as the newly developed orbit correction system which reduces the time needed for an orbit bump application down to well below 20 milliseconds.

43 PARTICLE ACCELERATORS↗

MICE: The International Muon Ionization Cooling Experiment: Phase Space Cooling Measurement

MICE is an experimental demonstration of muon ionization cooling using a section of an ionization cooling channel and a muon beam. The muons are produced by the decay of pions from a target dipping into the ISIS proton beam at Rutherford Appleton Laboratory (RAL). The channel includes liquid-hydrogen absorbers providing transverse and longitudinal momentum loss and high-gradient radiofrequency (RF) cavities for longitudinal reacceleration, all packed into a solenoidal magnetic channel. MICE will reduce the beam transverse emittance by about 10% for muon momenta between 140 and 240 MeV/c. Time-of-flight (TOF) counters, threshold Cherenkov counters, and a calorimeter will identify background electrons and pions. Spectrometers before and after the cooling section will measure the beam transmission and input and output emittances with an absolute precision of 0.1%.

43 PARTICLE ACCELERATORS↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗

Driven Spin Coherent Precession at RHIC

In a circular accelerator, exciting a coherent spin precession can be used to measure the spin precession tune, which is critical for understanding spin dynamics of the polarized beam. This can be achieved by driving the polarized beam with an rf dipole at an oscillating frequency f{sub res} in the vicinity of the beam spin precession frequency f{sub s}, namely, f{sub res}approx =f{sub s}. The driven coherent spin precession was measured with the RHIC Coulomb Nuclear Interference polarimeter using a carbon target. This paper presents the spin coherent precession observed with polarized proton beam at the BNL RHIC. Both experimental data and its application for spin tune measurement are discussed.

43 PARTICLE ACCELERATORS↗

Fighting the Residual Polarization Loss in the AGS

A dual partial snake scheme has been used for AGS polarized proton operation for several years. It has provided polarized proton beams with 1.5x10{sup 11} protons per bunch and 65% polarization for the RHIC spin program. There is still residual polarization loss due to both snake resonances and horizontal resonances as shown in the data. Several schemes were tested or proposed in the AGS to mitigate the loss, such as putting horizontal tune into the spin tune gap, injection into a accelerating bucket, and tune jump across the horizontal resonances. This paper presents the experiment and simulation results and analyses.

43 PARTICLE ACCELERATORS↗

First Experiments with the Polarized Internal Gas Target (PIT) at ANKE/COSY

For future few-nucleon interaction studies with polarized beams and targets at COSY-Juelich, a polarized internal storage-cell gas target was implemented at the magnet spectrometer ANKE. First commissioning of the polarized Atomic Beam Source (ABS) at ANKE was carried out and some improvements of the system have been done. Storage-cell tests to determine the COSY beam dimensions have been performed. Electron cooling combined with stacking and stochastic cooling have been studied. Experiments with N{sub 2} gas in the storage cell to simulate the background produced by beam interaction with the aluminum cell walls were performed to investigate the beam heating by the target gas. The analysis of the d-vectorp-vector->dp and d-vectorp-vector->(dp{sub sp})pi{sup 0} reactions showed that events from different positions of the extended target can be clearly identified in the ANKE detector system. The polarization of the atomic beam of the ABS, positioned close to the strong dipole magnet D2 of ANKE, was tuned with a Lamb-shift polarimeter (LSP) beneath the target chamber. With use of the known analyzing powers of the quasi-free np->dpi{sup 0} reaction, the polarization in the storage cell was measured to be Q{sub y} = 0.79+-0.07 in the vertical stray field of the D2 magnet acting as a holding field. The target thickness achieved was 2x10{sup 13} atoms/cm{sup 2} for one hyperfine state populated in the ABS beam only. With a COSY beam intensity of 6x10{sup 9} stored polarized deuterons in the ring, the luminosity for double polarized experiments was 1x10{sup 29} cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗

Do Unpolarized Electrons Affect the Polarization of a Stored Beam?

We present a short overview of the PAX physics case for polarized antiprotons. In order to progress towards a stored polarized antiproton beam, it is crucial to understand the interaction of polarized protons with unpolarized electrons. Therefore investigations that address in particular the contributions of electrons to the polarization buildup of a stored proton beam are presented here in more detail. The measurement of the depolarizing p-vectore cross section settled a long-standing controversy about the role of electrons in the polarization buildup of a stored beam by spin-filtering. Instead of studying the buildup of polarization in an initially unpolarized beam, here the inverse situation was investigated by observation of the depolarization of an initially polarized beam. For the first time, electrons in the electron cooler have been used as a target to study their depolarizing effect on a 49.3 MeV proton beam orbiting in COSY. The foreseen spin-filtering experiments at COSY-Juelich and at the AD of CERN are briefly discussed as well.

43 PARTICLE ACCELERATORS↗

Electron Spin Rotation And Matching Scheme For ELIC, A High-Luminosity Ring-Ring Electron-Ion Collider

A unique design feature of a polarized Electron-Ion Collider (ELIC) based on CEBAF is its Figure-8 shaped storage rings for both electrons and ions, which significantly simplifies beam polarization maintenance and manipulation. The CEBAF accelerator is used as a full energy injector of polarized electron beams into the electron storage ring. While electron polarization is maintained vertical in arcs of the ring, a stable longitudinal spin at four collision points is achieved through vertical crossing bending magnets, solenoid spin rotators, and horizontal orbit bends. Spin matching technique needs to be implemented in order to enhance quantum self-polarization and minimize depolarization effects. In this paper, we also discuss several important issues related to the use of positron beams, radiative polarization and quantum depolarization effects, as well as spin in ELIC.

43 PARTICLE ACCELERATORS↗

Experimental Verification of Predicted Oscillations near a Spin Resonance

The Chao matrix formalism allows analytic calculations of a beam's polarization behavior inside a spin resonance. We recently tested its prediction of polarization oscillations occurring in a stored beam of polarized particles near a spin resonance. Using a 1.85 GeV/c polarized deuteron beam stored in COSY, we swept a new rf solenoid's frequency rather rapidly through 400 Hz during 100 ms, while varying the distance between the sweep's end frequency and the central frequency of an rf-induced spin resonance. Our measurements of the deuteron's polarization for sweeps ending near and inside the resonance agree with the Chao formalism's predicted oscillations.

43 PARTICLE ACCELERATORS↗

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗