Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Reanalysis of the Apollo cosmic gamma-ray spectrum in the 0.3 to 10 MeV energy region

Additional data obtained from the Apollo 16 and 17 missions, together with collateral calculations on background radiation effects, have made possible an improved subtraction of unwanted backgrounds from the diffuse cosmic gamma ray data previously reported from Apollo 15. As a result, the 1 to 10 MeV spectrum is lowered significantly and connects smoothly with recent data at other energies. The inflection reported previously is much less pronounced and has no more than 1.5 sigma significance. Sky occultation by the Apollo 16 spacecraft shows the bulk of the 0.3 to 1 MeV radiation to be diffuse. The analysis of spurious backgrounds points to important improvements for future experiments designed for this spectral region. A light-weight satellite design can give a fourfold improvement in the signal to noise for such a measurement. Use of an anisotropic central crystal, which spins quickly compared with possible time variations in detector background, would enable sensitive limits to be set on galactic plane and point source contributions.

Dyer, C. S.↗

Reanalysis of the Apollo cosmic gamma-ray spectrum in the 0.3 to 10 MeV energy region

Additional data obtained from the Apollo 16 and Apollo 17 missions, together with collateral calculations on background radiation effects, have made possible an improved subtraction of unwanted backgrounds from the diffuse cosmic gamma-ray data previously reported from Apollo 15. As a result, the 1- to 10-MeV spectrum is lowered significantly and connects smoothly with recent data at other energies. The inflection reported previously is much less pronounced and has no more than a 1.5-sigma significance. Sky occultation by the Apollo 16 spacecraft shows the bulk of the 0.3- to 1-MeV radiation to be diffuse. The analysis of spurious backgrounds points to important improvements for future experiments designed for this spectral region.

Trombka, J. I.↗

Pentagonal prism spherical hohlraums for OMEGA

A new configuration is proposed for spherical hohlraums on OMEGA in which seven laser entrance holes (LEHs) are used—five around the equator and one at each pole [Farmer et al., Phys. Plasmas 26, 032701 (2019)]. This is known as the PEPR (pentagonal prism) hohlraum. A new view-factor code LORE is used to model the PEPR hohlraum and compare its performance with tetrahedral hohlraums shot on OMEGA. With optimization of beam pointings, the PEPR hohlraum produces a nonuniformity ranging from 1.1% (rms) at low albedos to 0.6% at high albedos. The tradeoffs between hohlraum-to-capsule ratio, uniformity, and background radiation temperature have been explored, and it has been shown that larger LEH radii on the poles can result in a modest improvement in uniformity. Here, the seven-hole PEPR hohlraum is well matched to the OMEGA symmetry and promises to provide insight into the performance of spherical hohlraums including octahedral (six-LEH) hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on running vacuum model with H ( z ) and f σ{sub 8}

We examine the running vacuum model with Λ ( H ) = 3 ν H {sup 2} + Λ{sub 0}, where ν is the model parameter and Λ{sub 0} is the cosmological constant. From the data of the cosmic microwave background radiation, weak lensing and baryon acoustic oscillation along with the time dependent Hubble parameter H ( z ) and weighted linear growth f ( z )σ{sub 8}( z ) measurements, we find that ν=(1.37{sup +0.72}{sub −0.95})× 10{sup −4} with the best fitted χ{sup 2} value slightly smaller than that in the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

A Methodology for Determining the Concentration of Naturally Occurring Radioactive Materials in an Urban Environment

The detection of radioactive sources in an urban setting is greatly complicated by natural background radiation, which emanates from various materials including roadways, sidewalks, soil, and building exteriors. The method presented and demonstrated here represents an effort to characterize the concentration of naturally occurring radioactive material (NORM) in these types of materials. The location surveyed in this work was the Fort Indiantown Gap Combined Arms Collective Training Facility in Lebanon County, Pennsylvania. Over 70 measurements with a high-purity germanium detector were performed to ascertain the NORM concentrations present in the soil, asphalt, gravel, concrete, and walls found throughout the site. Monte Carlo radiation transport calculations were used to obtain detector responses for these various geometries and materials to convert these measurements into NORM concentration estimates. Lastly, synthetic spectra were simulated using the predicted source terms and compared to actual measurements, showing acceptable agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emissivity measurement of coated copper and aluminum samples at 80 K

Accelerator cryomodules reduce the radiative thermal load to the 1.8 – 4.5 K components by enclosing them within low-emissivity shields cooled to 70–100 K. These heat shields are not continuous and have many penetrations, or holes, to allow for the connection of support structures and the many subsystems running from room temperature. The penetrations have thermal baffles to reduce, or eliminate if possible, the direct line-of-sight between room temperature and the lower temperature components but leave many, low emissivity, paths with only a single reflection required for the room temperature photons to strike the 1.8 – 4.5 K surfaces. To reduce this we are coating our baffles such that the surfaces which face lower temperatures have a low-emissivity while the surfaces which the photons may reflect from but do not have line-of-sight to lower temperature surfaces have a high-absorption. We measure emissivities of different coatings from the heat balance between absorption, from background radiation and the heater attached on the sample, and emission powers. In this paper, design details of our experiment and measurement results will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

METHOD FOR SIMULTANEOUS 90SR AND 137CS IN-VIVO MEASUREMENTS OF SMALL ANIMALS AND OTHER ENVIRONMENTAL MEDIA DEVELOPED FOR THE CONDITIONS OF THE CHERNOBYL EXCLUSION ZONE

To perform in vivo simultaneous measurements of the {sup 90}Sr and {sup 137}Cs content in the bodies of animals living in the Chernobyl Exclusion Zone (ChEZ), an appropriate method and equipment were developed and installed in a mobile gamma beta spectrometry laboratory. This technique was designed for animals of relatively small sizes (up to 50 g). The {sup 90}Sr content is measured by a beta spectrometer with a 0.1 mm thick scintillation plastic detector. The spectrum processing takes into account the fact that the measured object is 'thick-layered' and contains a comparable quantity of {sup 137}Cs, which is a characteristic condition of the ChEZ. The {sup 137}Cs content is measured by a NaI scintillation detector that is part of the combined gamma beta spectrometry system. For environmental research performed in the ChEZ, the advantages of this method and equipment (rapid measurements, capability to measure live animals directly in their habitat, and the capability of simultaneous {sup 90}Sr and {sup 137}Cs measurements) far outweigh the existing limitations (considerations must be made for background radiation and the animal size, skeletal shape and body mass). The accuracy of these in vivo measurements is shown to be consistent with standard spectrometric and radiochemical methods. Apart from the in vivo measurements, the proposed methodology, after a very simple upgrade that is also described in the article, works even more accurately with samples of other media, such as soil and plants.

54 ENVIRONMENTAL SCIENCES↗

RadMAP: The Radiological Multi-sensor Analysis Platform

The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. Here we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

47 OTHER INSTRUMENTATION↗

Inertial mechanism: Dynamical mass as a source of particle creation

A kinetic theory of vacuum particle creation under the action of an inertial mechanism is constructed within a nonperturbative dynamical approach. At the semi-phenomenological level, the inertial mechanism corresponds to quantum field theory with a time-dependent mass. At the microscopic level, such a dependence may be caused for different reasons: the non-stationary Higgs mechanism, the influence of a mean field or condensate, the presence of a conformal multiplier in the scalar-tensor gravitation theory, etc. In what follows, a kinetic theory in the collisionless approximation is developed for scalar, spinor, and massive vector fields in the framework of the oscillator representation, which is an effective tool for transition to the quasiparticle description and for derivation of non-Markovian kinetic equations. Properties of these equations and relevant observables (particle number and energy densities, pressure) are studied. The developed theory is applied here to describe the vacuum matter creation in conformal cosmological models and explain the observed number density of photons in the cosmic microwave background radiation. As another example, the self-consistent evolution of scalar fields with non-monotonic self-interaction potentials (the W-potential and Witten-Di Vecchia-Veneziano model) is considered. In particular, conditions for the appearance of tachyonic modes and the problem of the relevant definition of a vacuum state are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the contribution of a stochastic background of gravitational radiation to the timing noise of pulsars

The influence of a stochastic and isotropic background of gravitational radiation on timing measurements of pulsars is investigated, and it is shown that pulsar timing noise may be used to establish a significant upper limit of about 10 to the -10th on the total energy density of very long-wavelength stochastic gravitational waves. This places restriction on the strength of very long wavelength gravitational waves in the Friedmann model, and such a background is expected to have no significant effect on the approximately 3 K electromagnetic background radiation or on the dynamics of a cluster of galaxies.

Mashhoon, B.↗

Reference reactor module for NASA's lunar surface fission power system

Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO{sub 2}-fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gamma-ray and neutrino backgrounds as probes of the high-energy universe: hints of cascades, general constraints, and implications for TeV searches

Recent observations of isotropic diffuse backgrounds by Fermi and IceCube allow us to get more insight into distant very-high-energy (VHE) and ultra-high-energy (UHE) gamma-ray/neutrino emitters, including cosmic-ray accelerators/sources. First, we investigate the contribution of intergalactic cascades induced by gamma-rays and/or cosmic rays (CRs) to the diffuse gamma-ray background (DGB) in view of the latest Fermi data. We identify a possible 'VHE Excess' from the fact that the Fermi data are well above expectations for an attenuated power law, and show that cascades induced by VHE gamma rays (above ∼ 10 TeV) and/or VHECRs (below ∼ 10{sup 19} eV) may significantly contribute to the DGB above ∼ 100 GeV. The relevance of the cascades is also motivated by the intergalactic cascade interpretations of extreme TeV blazars such as 1ES 0229+200, which suggest very hard intrinsic spectra. This strengthens the importance of future detailed VHE DGB measurements. Then, more conservatively, we derive general constraints on the cosmic energy budget of high-energy gamma rays and neutrinos based on recent Fermi and IceCube observations of extragalactic background radiation. We demonstrate that these multi-messenger constraints are useful and the neutrino limit is very powerful for VHE/UHE hadronic sources. Furthermore, we show the importance of constraints from individual source surveys by future imaging atmospheric Cherenkov telescopes such as Cherenkov Telescope Array, and demonstrate that the cascade hypothesis for the VHE DGB can be tested by searching for distant emitters of cascaded gamma rays.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-142: Prompt Gamma Emission Measurements From a Passively Scattered Proton Beam On Targets Containing 16O, 12C and 14N

Purpose: To measure the prompt gamma emission from the important elements found in tissue ({sup 16}O,{sup 12}C and {sup 14}N) in a clinical passive-scatter treatment environment. Methods: The targets (composed of water, Perspex, graphite and liquid nitrogen) were irradiated with a 200 MeV passive-scatter proton beam and the discrete prompt gamma energy spectra was detected by a high resolution 2′ × 2′ LaBr. detector. In order to reduce the high level of radiation produced by the beam line elements, the detector was surrounded by 10 cm of lead to attenuate the scattered gamma-rays entering the detector with an extra 5 cm thick layer of lead added along the beam direction. A 10 cm thick collimator with a 5 cm × 10 cm rectangular opening was also used. Results: The prompt gamma peaks at 6.13 MeV and 4.44 MeV were clearly identified as a Result of the inelastic nuclear reaction between the protons and the 16O atoms found in the water target. The 6.13 MeV peak was 5% higher than the peak at 4.44 MeV for the water target. The 4.44 MeV peak was the only identified emission in the prompt gamma energy spectra from the graphite target ({sup 12}C). The expected 2.313 MeV peak form the{sup 14}N (liquid nitrogen target) was identified, but the other expected {sup 14}N peaks could not be resolved. Conclusion: Prompt gamma measurements with a passive-scatter proton beam are possible, but the presence of a high amount of background radiation from the patient final collimator presents a challenge at the treatment isocenter. The prominent prompt gamma peaks at 6.13 MeV and 4.44 MeV were identified from the water, Perspex and graphite targets. The prompt gammas from the liquid nitrogen target were difficult to see, but may not be significant in the in-vivo verification process.

60 APPLIED LIFE SCIENCES↗

Cosmological constraints on decoupled dark photons and dark Higgs

Any neutral boson such as a dark photon or dark Higgs that is part of a non-standard sector of particles can mix with its standard model counterpart. When very weakly mixed with the Standard Model, these particles are produced in the early Universe via the freeze-in mechanism and subsequently decay back to standard model particles. In this work, we place constraints on such mediator decays by considering bounds from Big Bang nucleosynthesis and the cosmic microwave background radiation. We find both nucleosynthesis and CMB can constrain dark photons with a kinetic mixing parameter between log ϵ∼−10 to −17 for masses between 1 MeV and 100 GeV. Similarly, the dark Higgs mixing angle ϵ with the Standard Model Higgs is constrained between log ϵ∼−6 to −15. Dramatic improvement on the bounds from CMB spectral distortions can be achieved with proposed experiments such as PIXIE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How dense is your gas? On the recoverability of LVG model parameters

We explore the recoverability of gas physical conditions with the Large Velocity Gradient (LVG) model, using the public code RADEX and the molecules HCN and CO. Examining a wide parameter range with a series of models of increasing complexity, we use both grid and Monte Carlo Markov Chain methods to recover the input conditions, and quantify the inherent and noise-induced uncertainties in the model results. We find that even with the benefit of generous assumptions, the LVG models struggle to recover any parameter better than to within half a dex, although we find no evidence of systemic offsets. Examining isotopologue lines, we demonstrate that it is always preferable to model the isotopologue abundance ratio as a free parameter due to large biases introduced in all other parameters when an incorrect ratio is assumed. Finally, we explore the effects of the background radiation temperature on CO and HCN line ratios, with an emphasis on the effect of the CMB at z>4, and show that while the effect on the line ratios is minor, the effect on the spectral line energy distribution peak is significant and that the CO(1–0) line luminosity to H{sub 2} mass conversion factor (α{sub CO}) needs to be altered to account for the loss of contrast against the hotter CMB as redshift increases.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray diagnostic developments in the perspective of DEMO

Soft X-ray diagnostics at present are not adequate for a burning plasma experiment, neither in term of hardware nor as diagnostic conception. Detectors have to be radiation tolerant, easily shielded, with low sensitivity to neutrons and gammas and with energy discrimination. Layout and viewing capability should be more flexible, thanks to the use also of optical devices, going toward a configuration intermediate between discrete tomography and pure imaging. The general conception of these diagnostics should therefore evolve in the direction of pattern recognition for a real time feedback. This work is focused on the diagnostic developments undertaken at the ENEA- Frascati X-ray Laboratory, following in particular three directions: gas detector for fast and advanced high density tomography, C-MOS solid state imaging detectors for slow control and X-ray polycapillary optics. GEM gas detectors in photon counting mode (noise free) were developed in the range 1-30 keV having high efficiency, high time resolution (up to microseconds), energy discrimination in bands and optical flexibility. Discrimination of X-rays, neutrons and gammas has been demonstrated, thanks to the combination of intrinsic gain and discrimination thresholds, at neutron fluxes (10{sup 7} n/s*cm{sup 2}) comparable with the expected ones at the ports of ITER. GEM detectors are also extremely flexible in the design, allowing optimization of the measurements and solutions for shielding or minimization of the effect of background radiation. Two solid state C-MOS imagers working in photon counting mode, one based on Si semiconductor (Medipix-2, range 5-30 keV) and the other one having a CdTe sensor (Pixirad, range 2-100 keV) have been characterized in laboratory. C-MOS imagers have features and performances thoroughly complementary to the GEM detector and, thanks to their higher pixel density, could be used as remote imaging detectors coupled to optics. X-ray polycapillary lenses have been therefore studied in the laboratory both as imaging optical device (full lens) or to define a line of sight (cylinder lens); the preliminary results are encouraging toward the goal of using these lenses to transport X-ray radiation far from the reactor. Reflective or diffractive X-ray optics can be also an option for tomography. A GEM detector has been installed at KSTAR and in the next future hopefully the other approaches will be tested there: once their feasibility will be demonstrated, the issue of the improvement of the radiation tolerance will be faced and the development of algorithms for data analysis as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generating Polarized High-Brightness Muon Beams With High-Energy Gammas

Hadron colliders are impractical at very high energies as effective interaction energy is a fraction of the energies of the beams and luminosity must rise as energy squared. Further, the prevailing gluon-gluon background radiation makes it difficult to sort out events. e{sup +}e{sup -} colliders, on other hand, are constrained at TeV energies by beamstrahlung radiation and also by cost as long linacs are required to avoid synchrotron radiation in the rings. A muon collider will have the same advantages in energy reach as an e{sup +}e{sup -} collider, but without prohibitive beamstrahlung- and synchrotron- radiation. Generation of the high-brightness polarized muon ({mu}{sup -}{mu}{sup +}) beams through gamma conversion into pairs in the nuclei field is considered in this paper. The dominant effect in the interaction of the high-energy photons with the solid target will be the production of electron-positron pairs. The low-phase space of the resulting muon beams adequately compensates for the small probability of generating a {mu}{sup -}{mu}{sup +} pair.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LARGE PECULIAR MOTION OF THE SOLAR SYSTEM FROM THE DIPOLE ANISOTROPY IN SKY BRIGHTNESS DUE TO DISTANT RADIO SOURCES

According to the cosmological principle, the universe should appear isotropic, without any preferred directions, to an observer whom we may consider to be fixed in the comoving coordinate system of the expanding universe. Such an observer is stationary with respect to the average distribution of the matter in the universe and the sky brightness at any frequency should appear uniform in all directions to such an observer. However, a peculiar motion of such an observer, due to a combined effect of Doppler boosting and aberration, will introduce a dipole anisotropy in the observed sky brightness; in reverse an observed dipole anisotropy in the sky brightness could be used to infer the peculiar velocity of the observer with respect to the average universe. We determine the peculiar velocity of the solar system relative to the frame of distant radio sources, by studying the anisotropy in the sky brightness from discrete radio sources, i.e., an integrated emission from discrete sources per unit solid angle. Our results give a direction of the velocity vector in agreement with the cosmic microwave background radiation (CMBR) value, but the magnitude ({approx}1600 {+-} 400 km s{sup -1}) is {approx}4 times the CMBR value (369 {+-} 1 km s{sup -1}) at a statistically significant ({approx}3{sigma}) level. A genuine difference between the two dipoles would imply an anisotropic universe, with the anisotropy changing with the epoch. This would violate the cosmological principle where the isotropy of the universe is assumed for all epochs, and on which the whole modern cosmology is based upon.

79 ASTRONOMY AND ASTROPHYSICS↗