Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Method Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SU-E-T-631: Preliminary Results for Analytical Investigation Into Effects of ArcCHECK Setup Errors

Purpose: As three-dimensional diode arrays increase in popularity for patient-specific quality assurance for intensity-modulated radiation therapy (IMRT), it is important to evaluate an array’s susceptibility to setup errors. The ArcCHECK phantom is set up by manually aligning its outside marks with the linear accelerator’s lasers and light-field. If done correctly, this aligns the ArcCHECK cylinder’s central axis (CAX) with the linear accelerator’s axis of rotation. However, this process is prone to error. This project has developed an analytical expression including a perturbation factor to quantify the effect of shifts. Methods: The ArcCHECK is set up by aligning its machine marks with either the sagittal room lasers or the light-field of the linear accelerator at gantry zero (IEC). ArcCHECK has sixty-six evenly-spaced SunPoint diodes aligned radially in a ring 14.4 cm from CAX. The detector response function (DRF) was measured and combined with inverse-square correction to develop an analytical expression for output. The output was calculated using shifts of 0 (perfect alignment), +/−1, +/−2 and +/−5 mm. The effect on a series of simple inputs was determined: unity, 1-D ramp, steps, and hat-function to represent uniform field, wedge, evenly-spaced modulation, and single sharp modulation, respectively. Results: Geometric expressions were developed with perturbation factor included to represent shifts. DRF was modeled using sixth-degree polynomials with correlation coefficient 0.9997. The output was calculated using simple inputs such as unity, 1-D ramp, steps, and hat-function, with perturbation factors of: 0, +/−1, +/−2 and +/−5 mm. Discrepancies have been observed, but large fluctuations have been somewhat mitigated by aliasing arising from discrete diode placement. Conclusion: An analytical expression with perturbation factors was developed to estimate the impact of setup errors on an ArcCHECK phantom. Presently, this has been applied to simple functions, but is being developed to handle more realistic clinical cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a formaldehyde biosensor with application to synthetic methylotrophy

Formaldehyde is a prevalent environmental toxin and a key intermediate in single carbon metabolism. The ability to monitor formaldehyde concentration is, therefore, of interest for both environmental monitoring and for metabolic engineering of native and synthetic methylotrophs, but current methods suffer from low sensitivity, complex workflows, or require expensive analytical equipment. Here we develop a formaldehyde biosensor based on the FrmR repressor protein and cognate promoter of Escherichia coli . Optimization of the native repressor binding site and regulatory architecture enabled detection at levels as low as 1 µM. We then used the sensor to benchmark the in vivo activity of several NAD‐dependent methanol dehydrogenase (Mdh) variants, the rate‐limiting enzyme that catalyzes the first step of methanol assimilation. In order to use this biosensor to distinguish individuals in a mixed population of Mdh variants, we developed a strategy to prevent cross‐talk by using glutathione as a formaldehyde sink to minimize intercellular formaldehyde diffusion. Finally, we applied this biosensor to balance expression of mdh and the formaldehyde assimilation enzymes hps and phi in an engineered E. coli strain to minimize formaldehyde build‐up while also reducing the burden of heterologous expression. This biosensor offers a quick and simple method for sensitively detecting formaldehyde, and has the potential to be used as the basis for directed evolution of Mdh and dynamic formaldehyde control strategies for establishing synthetic methylotrophy.

Woolston, Benjamin M.↗

Toward predictive permeabilities: Experimental measurements and multiscale simulation of methanol transport in Nafion

A polymer membrane's permeability to solutes determines its suitability for various applications: a permeability value is essential for predicting performance in diverse contexts. Using aqueous methanol permeation through Nafion as an example, we describe a methodology for determining membrane permeability that accounts for boundary layer effects and the possibility of swelling. For the materials and apparatus used herein, analysis of a permeance measurement and computational fluid dynamics simulations show that the mass transfer boundary layer is on the order of ones to tens of microns. Additionally, the data are used to develop and validate a multiscale model describing solute permeation through a hydrated membrane as a series of physical mechanistic steps: reversible adsorption from solution at the membrane interface, diffusion driven by a concentration gradient within the membrane, and reversible desorption into solution at the opposite membrane interface. The validated model is used to predict methanol transport across a solar-driven CO 2 reduction device and to assess the impact of polymer changes on the measured value. The approach of combining experimental data, computational fluid dynamics, and the mechanistic multiscale model is expected to provide more accurate analysis of membrane permeation data in cases with polymer swelling or unusual device geometries, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the Basis for an Analytical Protocol for Feeds and Products of Bio-oil Hydrotreatment

Methods for easily following the main changes in the composition, stability, and acidity of bio-oil in hydrotreatment are presented. The correlation to more conventional methods is provided. Depending on the final use the upgrading requirement is different. This will create challenges also for the analytical protocol. Polar pyrolysis liquids and their products can be divided into five main groups with solvent fractionation the change in which is easy to follow. This method has over ten years been successfully used for comparison of fast pyrolysis bio-oil quality, and the changes during handling, and storage, provides the basis of the analytical protocol presented in this paper. The method has most recently been used also for characterisation of bio-oil hydrotreatment products. Discussion on the use of gas chromatographic and spectroscopic methods is provided. In addition, fuel oil analyses suitable for fast pyrolysis bio-oils and hydrotreatment products are discussed.

02 PETROLEUM↗

Microchannel gel electrophoretic separation systems and methods for preparing and using

A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

47 OTHER INSTRUMENTATION↗

Advanced Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) Demonstration

A key area of the Advanced Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) strategy is the development of methodologies and tools that will be used to predict the safety, security, safeguards, performance, and deployment viability of SMRs. The goal of the SMR PRA activity will be to develop quantitative methods and tools and the associated analysis framework for assessing a variety of risks. Development and implementation of SMR-focused safety assessment methods may require new analytic methods or adaptation of traditional methods to the advanced design and operational features of SMRs. We will need to move beyond the current limitations such as static, logic-based models in order to provide more integrated, scenario-based models based upon predictive modeling which are tied to causal factors. The development of SMR-specific safety models for margin determination will provide a safety case that describes potential accidents, design options (including postulated controls), and supports licensing activities by providing a technical basis for the safety envelope. This report documents the progress that was made to implement the PRA framework, specifically by way of demonstration of an advanced 3D approach to representing, quantifying and understanding flooding risks to a nuclear power plant.

97 MATHEMATICS AND COMPUTING↗

Multi-Task with Procter and Gamble (CRADA No. NFE-10-02672)

The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC (the “Contractor) and Procter & Gamble Company (the “Participant”) is the development of a research partnership to create new tools, tests and analytical methods to improve the performance, safety and/or environmental quality of chemicals, advanced materials, food products and manufacturing processes. The Participant operates in three global business units: Beauty, Health and Well-Being and Household Care. Some of its worldwide products include Head and Shoulders®, Pantene®, Gillette® razors and personal care products, Crest®, Dawn®, Tide®, Bounty®, Duracell® batteries; and Iams® pet food among others. At its core, however, the Participant is a science driven company. It supports one of the most robust industrial research and development (R&D) programs in the world. The Participant uses this rich foundation of science to drive innovation across all of its product lines. But the innovation process is not confined in-house The Participant pursues an “open innovation” policy, seeking partnerships with scientists and researchers in universities and national laboratories where it can contribute its extensive knowledge assets and collaborate to advance scientific understanding. The research under this multi-task CRADA was directed under the following general task areas and, throughout the duration of this CRADA the work statement was modified to match the needs of the Parties and the direction of the research. (1) Software modeling, simulation and development; (2) Manufacturing Technologies; (3) Supply Chain Optimization, (4) Advanced Materials.

36 MATERIALS SCIENCE↗

Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers

Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.

36 MATERIALS SCIENCE↗

Literature Review of Generalized Two-Dimensional Correlation Spectroscopy (2D-COS)

Generalized two-dimensional correlation spectroscopy (2D-COS) is a technique that has improved on traditional spectroscopic techniques by exposing samples to a variable amount of an external perturbation before they have been probed spectroscopically through IR, UV, Raman, etc. These perturbed signals are plotted over a second independent wavenumber axis and after mathematical manipulation, a dynamic spectrum is created that shows the synchronous and asynchronous spectra. The dynamic spectrum shows the way spectral changes in the material are correlated to each other, and a mechanism of material degradation can be proposed through a set of rules that Noda proposed. This technique is important to spectroscopic studies because of improved spectral resolution and the identification of complex or overlapping bands that cannot be distinguished in traditional analytical methods. This technique has been widely utilized since its inception, and has developed towards protein studies, as well as even wine chemistry, because of the advanced capabilities of band separation. Two-dimensional hetero-spectral correlation analysis has also been developed to find correlations in spectra with different spectroscopic probes. 2D-COS as an analytical technique has increasing avenues of expansion, and can be creatively used in many other fields in the future.

2D-COS↗

Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

Purpose: The authors describe the modifications to a previously developed analytical model of indirect CsI:Tl-based detector response required for studying oblique x-ray incidence effects in direct semiconductor-based detectors. This first-order approximation analysis allows the authors to describe the associated degradation in resolution in direct detectors and compare the predictions to the published data for indirect detectors. Methods: The proposed model is based on a physics-based analytical description developed by Freed et al. [''A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems,'' Med. Phys. 37(6), 2593-2605 (2010)] that describes detector response functions for indirect detectors and oblique incident x rays. The model, modified in this work to address direct detector response, describes the dependence of the response with x-ray energy, thickness of the transducer layer, and the depth-dependent blur and collection efficiency. Results: The authors report the detector response functions for indirect and direct detector models for typical thicknesses utilized in clinical systems for full-field digital mammography (150 {mu}m for indirect CsI:Tl and 200 {mu}m for a-Se direct detectors). The results suggest that the oblique incidence effect in a semiconductor detector differs from that in indirect detectors in two ways: The direct detector model produces a sharper overall PRF compared to the response corresponding to the indirect detector model for normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction compared to that found in indirect detectors with respect to the response at normal incidence angles. Conclusions: Compared to the effect seen in indirect detectors, the direct detector model exhibits a sharper response at normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction with respect to the blur in the orthogonal direction. The results suggest that the oblique incidence effect in direct detectors can be considered to be caused mostly by the geometry of the path where the x-ray beam and its secondary particles deposit energy in the semiconductor layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Physics Investigation of a Natural Circulation Molten Salt Micro-Reactor that Utilizes an Experimental In-Pile Device to Improve Core Physics and System Thermal-Hydraulic Performance.

INL employee PhD Dissertation - The Molten Salt Reactor (MSR) concept is a rapidly evolving Generation IV design that has recently attracted favorable attention due to the potential for reducing waste generation, realizing passive safety features, and seizing on the opportunity for cost effective economics. This thesis investigates the performance benefit of a new device invented by the doctoral candidate. The device is referred to as a Wrapped Helix around an Inclined Plane or WHIP. The WHIP is protected under a provisional patent filed with the USA Patent Office on 28 September 2021 under application number 63/261,776, BEA docket number BA-1254. The WHIP device can be located in-core or near-core to promoted enhanced thermal-hydraulics and neutronics performance. While the WHIP can be employed in a variety of solid or liquid fuel designs, this thesis investigates the device’s benefit in the application of a natural-circulation, micro-molten salt nuclear battery concept (MsNB). This thesis will specifically investigate the temperature coefficient of the MsNB fuel (FLiNaK) using novel temperature sensitivity techniques unique to Serpent particle transport code, evaluate the WHIP’s thermal-hydraulic and neutronic performance effects using both established (STAR-CCM+) and novel (Python code developed to estimate the circulation effective delayed neutron fraction, ßef f ) analytical and numerical methods, evaluate the neutron noise behavior of the MsNB and how the WHIP may alter the character of the MsNB’s transfer function, and how the WHIP affects the autonomous, load-following performance under transient power conditions using Python code developed by the candidate. The sum body of this work, in part, has been published in three journal articles as the timing of the provisional patent process has allowed. Results show that creative utilization of WHIP engineering design and function reduces reactor system volume, fuel loading, control/stability in the buoyant regime

buoyant flow↗

Elevating density functional theory to chemical accuracy for water simulations through a density-corrected many-body formalism

Abstract Density functional theory (DFT) has been extensively used to model the properties of water. Albeit maintaining a good balance between accuracy and efficiency, no density functional has so far achieved the degree of accuracy necessary to correctly predict the properties of water across the entire phase diagram. Here, we present density-corrected SCAN (DC-SCAN) calculations for water which, minimizing density-driven errors, elevate the accuracy of the SCAN functional to that of “gold standard” coupled-cluster theory. Building upon the accuracy of DC-SCAN within a many-body formalism, we introduce a data-driven many-body potential energy function, MB-SCAN(DC), that quantitatively reproduces coupled cluster reference values for interaction, binding, and individual many-body energies of water clusters. Importantly, molecular dynamics simulations carried out with MB-SCAN(DC) also reproduce the properties of liquid water, which thus demonstrates that MB-SCAN(DC) is effectively the first DFT-based model that correctly describes water from the gas to the liquid phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comprehensive Chemical Fingerprinting by Multidimensional GC and Supervised Machine Learning

This project leverages advances in machine learning based data analysis techniques and untargeted omic analytical methods to progress nuclear nonproliferation technologies beyond current capabilities. The developed approaches can be used to identify and detect complex chemical fingerprints of facilities of interest. These techniques have been developed for fields such as metabolomics and genomics but have not been applied to nuclear nonproliferation applications. Adaptation of these techniques for volatile organic compound analysis has far reaching application within the scientific community including environmental chemistry, atmospheric physics, and climate sciences.

97 MATHEMATICS AND COMPUTING↗

Lignin Utilization

Valorization of lignin has massive potential economic and sustainability benefits for the lignocellulosic biorefinery. However, challenges remain to realize lignin conversion to coproducts, especially related to selective, high yield depolymerization to monomers and quantitative analytics on lignin, the latter of which is critical for accurate process modeling. Towards these goals, the Lignin Utilization project focuses on catalytic lignin deconstruction chemistries for C-O and C-C bond cleavage, development of analytical chemistry techniques to quantitatively characterize lignin, and syntheses of requisite model compounds for understanding lignin transformations. This work is done with and supports multiple BETO projects, including the Biological Lignin Valorization (BLV) project, the Separations Consortium, and others. Outcomes of Lignin Utilization for analytics and synthesis include 1) development of new mass spectrometry (MS) methods to characterize lignin dimers/oligomers in process streams, 2) deployment of a computational-experimental tool (with Biochemical Process Modeling and Simulation) to identify lignin-derived compounds with high fidelity from MS, and 3) delivery of >40 unique compounds. From a catalysis perspective, we have developed new oxidative approaches to cleave C-O and C-C bonds and produce >50% bio-available aromatic monomers for biological funneling for the BLV project and have developed recoverable bases for base-catalyzed deconstruction of lignin.

BIOMASS FUELS↗

Web-Assisted Methods and Tools for Efficient Remedy Design and System Performance Evaluation at Hanford - 19355

A suite of analytical and numerical methods and web-assisted tools has been developed in support of remedial design and system performance evaluation at the U.S. Department of Energy's Hanford Site in Richland, Washington. These innovative methods and tools facilitate robust and efficient assessments and provide project scientists with a toolbox for performance monitoring of monitored natural attenuation and pump-and-treat remedies and for identifying necessary design elements and system improvements for attainment of remedial action objectives and ultimately site closure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗