Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aging analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Chemical and Thermal Analysis

Work during the past three years has included significant research in several areas aimed at further clarification of the aging and chemical failure mechanism of thermoplastics (PVDF or Tefzel) for pipes. Among the areas investigated were the crystallinity changes associated with both the Coflon and Tefzel after various simulated environmental exposures using X-Ray diffraction analysis. We have found that significant changes in polymer crystallinity levels occur as a function of the exposures. These crystallinity changes may have important consequences on the fracture, fatigue, tensile, and chemical resistance of the materials. We have also noted changes in the molecular weight distribution and the increased crosslinking of the Coflon material using Gel Permeation Chromatographic Analysis. Again these changes may result in variations in the mechanical and chemical properties in the material. We conducted numerous analytical studies with methods including X-ray Diffraction, Gel Permeation Chromatography, Fourier Transform Infrared Spectroscopy, and Differential Scanning Calorimetry. We investigated a plethora of aged samples of both Tefzel and Coflon that were forwarded from MERL. Pressurized tests were performed on powdered PVDF in a modified Fluid A, which we will call A-2. In this case the ethylene diamine concentration was increased to 3 percent in methanol. Coflon pipe sections and powdered Coflon were exposed in pressure cells at 1700 psi at three separate test temperatures.

Bulluck, J. W.↗

Characterizing Fractures Across the Astronaut Corps: Preliminary Findings from Population-Level Analysis

Despite evidence of bone loss during spaceflight and operational countermeasures to mitigate this loss, the subsequent risk of fracture among astronauts is not known. The physiologic process of diminished bone density and bone recovery during or following spaceflight is multifactorial. Such factors as age, sex, fracture history, and others may combine to increase fracture risk among astronauts. As part of the 2016 Bone Research and Clinical Advisory Panel (RCAP), the authors analyzed data collected on 338 NASA astronauts to describe the demographics, bone-relevant characteristics, and fracture history of the astronaut population. The majority of the population are male (n=286, 84.6%), have flown at least one mission (n=306, 90.5%), and were between the ages of 30 and 49 at first mission (n=296, 96.7% of those with at least one mission). Of the 338 astronauts, 241 (71.3%) experienced a fracture over the course of their lifetime. One hundred and five (43.5%) of these 241 astronauts only experienced a fracture prior to being selected into the Astronaut Corps, whereas 53 (22.0%) only experienced a fracture after selection as an astronaut. An additional 80 astronauts (33.2%) had both pre- and post-selection fractures. The remaining 3 astronauts had a fracture of unknown date, which could not be categorized as pre- or post-selection. Among the 133 astronauts with at least one post-selection fracture, males comprised 90.2% (n=120) compared to 84.5% of the entire Corps, and females accounted for 9.8% (n=13) compared to 15.4% of the Corps. Ninety-seven of the 133 astronauts with post-selection fractures (72.9%) had one fracture event, 22 (16.5%) had two fractures, and 14 (10.5%) had three or more fractures. Some astronauts with multiple fractures suffered these in a single event, such as an automobile accident. The 133 astronauts with a post-selection fracture accounted for a total of 188 fracture events. One hundred and four (78.2%) of astronauts with post-selection fractures experienced those fractures following their first mission (mean 12.7 +/- 11.1 years following first mission; range 14.0 days - 50.6 years). Additional analyses are ongoing and include examination of fracture history, skeletal site, mechanism, and type of fracture, age at time of fracture, time from spaceflight to fracture, as well as multivariable analysis comparing fracture events to non-events. The results of such analyses may reveal trends in risk factors for fracture among the astronaut corps that have yet to be systematically described through a corps-wide approach.

Rossi, Meredith M.↗

Zinc and copper balances in healthy adult males during and after 17 wk of bed rest

The effects of long-term bed rest on zinc and copper balances were measured in seven healthy men. Volunteers aged 22-54 y (mean +/- SD, 34 +/- 12 y), 168-185 cm in height (173 +/- 5 cm), and 64-86 kg in weight (74 +/- 9 kg) remained on a metabolic ward for 29 wk. Subjects were ambulatory during weeks 1-5, remained in continuous bed rest for weeks 6-22, and were reambulated during weeks 23-29. Copper and zinc were measured in weekly urine and fecal composites. Dietary intakes provided (mean +/- SD) 19.2 +/- 1.2 mumol Cu (1.22 +/- 0.08 mg), 211 +/- 11 mumol Zn (13.81 +/- 0.72 mg), 25.2 +/- 1.2 mmol Ca (1011 +/- 46 mg), 1086 +/- 46 mmol N (15.21 +/- 0.65 g), and 48.1 +/- 1.4 mmol K (1489 +/- 44 mg)/d. Bed rest increased fecal zinc excretion and decreased zinc balance, whereas copper balance was unchanged. Reambulation decreased fecal zinc excretion and increased both zinc and copper balances. These results suggest that during long-term bed rest or space flight, individuals will lose total body zinc and will retain more zinc and copper when they reambulate.

Non-NASA Center↗

Crosscutting relations and relative ages of ridges and faults in the Tharsis region of Mars

The results of a detailed photogeologic analysis and classification of ridge-fault cross-cutting relationships on ridged plains units of the Tharsis region is reported. The problems involved in using the morphology of ridge-fault intersections to determine relative timing of structural events are discussed. The implications of using intersection angles as well as morphology to determine possible age relationships for the tectonic history of the region are presented. It is concluded that the major ridge-forming events in the Tharsis region were roughly coincident with, and possibly prior to, the extensional events that produced the faulting of the Tempe and Mareotis regions, the Coprates and Memnonia regions, and the rifting of the Valles Marineris. The compressional events that formed most of the ridges are restricted in time both by their relationship to regional extensional events and by the age of the units on which they formed.

Watters, T. R.↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of strontium metabolism in humans on the basis of the Techa river data

Age and sex features of strontium metabolism have been analyzed on studies of the population residing on the banks of the Techa river which was contaminated by fission products during the years 1949-1956. Measurements of 90Sr body burden have been performed since 1974 using a whole-body counter, and these have made it possible to estimate age-specific long-term retention and elimination rates for men and women. Regarding the retention that correlated with the respective maturation ages, distinct sex differences have been observed for adolescents, whereas only postmenopausal women showed a sharp increase of their elimination rates. There were no differences concerning the reproductive ages. Our experimental findings have a clear physiological interpretation and can be used to develop metabolic models for bone-seeking radionuclides.

NASA Discipline Radiation Health↗

Thermal, mechanical, and electrical properties of LSCo/mullite composite contact materials for solid oxide fuel cells

Lanthanum strontium cobaltite (LSCo) is considered as a good candidate cathode contact material for solid oxide fuel cells, due to high electrical conductivity. However, LSCo has a very large coefficient of thermal expansion (CTE) than the cells and metallic interconnects. As a result, poor mechanical stability is expected during thermal cycling. To minimize the CTE mismatch, we investigate a composite approach involving mixing LSCo with an inert material of low CTE, such as mullite at volume fractions from 0.1 to 0.4. Composite’s CTE shows a decreasing trend with increasing mullite volume fractions, and is consistent with model predictions. X-ray powder diffraction analysis of sintered LSCo/mullite composites exhibits no presence of other phases for samples aged for 500h at 800oC, indicating chemical compatibility. Electrical conductivity by a 4-pt method shows a decreasing trend with increasing mullite content. Contact strength of as-sintered and thermally cycled samples show that only the composite with 0.4 volume fraction has a measurable strength; the other composites have no strength. Overall, the composite approach is demonstrated in the LSCo/mullite system to lower the CTE and hence achieve thermal cycle stability. The addition of the inert phase to the LSCo matrix; however, also reduces the electrical conductivity.

Contact materials, LSCo, mullite, CTE, electrical ↗

Predicting drug-metagenome interactions: Variation in the microbial β-glucuronidase level in the human gut metagenomes

Characterizing the gut microbiota in terms of their capacity to interfere with drug metabolism is necessary to achieve drug efficacy and safety. Although examples of drug-microbiome interactions are well-documented, little has been reported about a computational pipeline for systematically identifying and characterizing bacterial enzymes that process particular classes of drugs. The goal of our study is to develop a computational approach that compiles drugs whose metabolism may be influenced by a particular class of microbial enzymes and that quantifies the variability in the collective level of those enzymes among individuals. The present paper describes this approach, with microbial β-glucuronidases as an example, which break down drug-glucuronide conjugates and reactivate the drugs or their metabolites. We identified 100 medications that may be metabolized by β-glucuronidases from the gut microbiome. These medications included morphine, estrogen, ibuprofen, midazolam, and their structural analogues. The analysis of metagenomic data available through the Sequence Read Archive (SRA) showed that the level of β-glucuronidase in the gut metagenomes was higher in males than in females, which provides a potential explanation for the sex-based differences in efficacy and toxicity for several drugs, reported in previous studies. Our analysis also showed that infant gut metagenomes at birth and 12 months of age have higher levels of β-glucuronidase than the metagenomes of their mothers and the implication of this observed variability was discussed in the context of breastfeeding as well as infant hyperbilirubinemia. Overall, despite important limitations discussed in this paper, our analysis provided useful insights on the role of the human gut metagenome in the variability in drug response among individuals. Importantly, this approach exploits drug and metagenome data available in public databases as well as open-source cheminformatics and bioinformatics tools to predict drug-metagenome interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Lifetimes of fiber composites under sustained tensile loading

A description is presented of the test techniques which have been used to apply sustained uniaxial tensile loading to fiber/epoxy composites. The fiber types used include S-glass, aramid, graphite, and beryllium wire. The applied load vs lifetime data for four composite materials are presented in graphs. Attention is given to a statistical analysis of data, a performance comparison of various composites, the age effect on the strength of composites, the applicability of the lifetime data to complex composites, and aspects of accelerated test method development. It is found that the lifetime of a composite under a sustained load varies widely. Depending on the composite system, the minimum life typically differs from the maximum life by a factor of 100 to 1000. It is in this connection recommended that a use of average life data should be avoided in serious design calculations.

Chiao, T. T.↗

Hydrothermal alteration in the 3.5 b.y. old Onverwacht Group of South Africa

K-Ar studies of authigenic and alteration phases from the 3.5 b.y. old Onverwacht group of South Africa delineate hydrothermal metamorphism that ended 3.3 b.y. years ago. A whole rock K-Ar errochron from analysis of barite, dolomite, chert, and serpentinite (komatiite) gives an age of 3.3 b.y. with an intercept of 1,678 + or - 103. The 3.3. b.y. age for the metamorphism in the Onverwacht was confirmed by the Argon isotopes stepwise heating experiments of komatiites and basaltic komatiites from the Onverwacht Group. In addition, the errochron suggests all the phase studied equilibrated with a reservoir of hydrothermal argon with relatively uniform isotopic composition. The concept of hydrothermal activity in the Onverwacht Group is discussed and illustrated with photographs.

Hart, R.↗

The tectonic setting of the Seychelles, Mascarene and Amirante Plateaus in the Western Equatorial Indian Ocean

A system of marine plateaus occurs in the western equatorial Indian Ocean, forming an arcuate series of wide and shallow banks with small islands in places. The oceanic basins that surround the Seychelles - Amirante region are of various ages and reflect a complex seafloor spreading pattern. The structural analysis of the Seychelle - Amirante - Mascarene region reflects the tectonic evolution of the western equatorial Indian Ocean. It is suggested that due to the seafloor spreading during a tectonic stage, the Seychelles continental block drifted southwestwards to collide with the oceanic crust of the Mascarene Basin, forming an elongated folded structure at first, and then a subduction zone. The morphological similarity, the lithological variability and the different origin of the Seychelles Bank, the Mascarene Plateau and the Amirante Arc emphasizes the significant convergent effects of various plate tectonic processes on the development of marine plateaus.

Mart, Y.↗

Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy: a real-time three-dimensional echocardiographic study

BACKGROUND: Left ventricular (LV) reconstruction surgery leads to early improvement in LV function in ischemic cardiomyopathy (ICM) patients. This study was designed to evaluate the impact of mitral valve (MV) repair associated with LV reconstruction on LV function 1-year after surgery in ICM patients assessed by real-time 3-dimensional echocardiography (3DE). METHODS AND RESULTS: Sixty ICM patients who underwent the combination surgery (LV reconstruction in 60, MV repair in 30, and revascularization in 52 patients) were studied. Real-time 3DE was performed and LV volumes were obtained at baseline, discharge, 6-month and >or=12-month follow-up. Reduction in end-diastolic volumes (EDV) by 29% and in end-systolic volumes by 38% were demonstrated immediately after surgery and remained at subsequent follow-up (P<0.0001). The LV ejection fraction significantly increased by about 10% at discharge and was maintained >or=12-month (P<0.0001). Although the LV volumes were significantly larger in patients with MV repair before surgery (EDV, 235+/-87 mL versus 193+/-67 mL, P<0.05), they were similar to LV volumes of the patients without MV repair at subsequent follow-ups. However, the EDV increased from 139+/-24 mL to 227+/-79 mL (P<0.01) in 7 patients with recurrent mitral regurgitation (MR). Improvement in New York Heart Association functional class occurred in 81% patients during late follow-up. CONCLUSIONS: Real-time 3DE demonstrates that LV reconstruction provides significant reduction in LV volumes and improvement in LV function which is sustained throughout the 1-year follow-up with 84% cardiac event free survival. If successful, MV repair may prevent LV redilation, while recurrent MR is associated with increased LV volumes.

Clinical Trial↗

Improved pulmonary function in working divers breathing nitrox at shallow depths

INTRODUCTION: There is limited data about the long-term pulmonary effects of nitrox use in divers at shallow depths. This study examined changes in pulmonary function in a cohort of working divers breathing a 46% oxygen enriched mixture while diving at depths less than 12 m. METHODS: A total of 43 working divers from the Neutral Buoyancy Laboratory (NBL), NASA-Johnson Space Center completed a questionnaire providing information on diving history prior to NBL employment, diving history outside the NBL since employment, and smoking history. Cumulative dive hours were obtained from the NBL dive-time database. Medical records were reviewed to obtain the diver's height, weight, and pulmonary function measurements from initial pre-dive, first year and third year annual medical examinations. RESULTS: The initial forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1) were greater than predicted, 104% and 102%, respectively. After 3 yr of diving at the NBL, both the FVC and FEV1 showed a significant (p < 0.01) increase of 6.3% and 5.5%, respectively. There were no significant changes in peak expiratory flow (PEF), forced mid-expiratory flow rate (FEF(25-75%)), and forced expiratory flow rates at 25%, 50%, and 75% of FVC expired (FEF25%, FEF50%, FEF75%). Cumulative NBL dive hours was the only contributing variable found to be significantly associated with both FVC and FEV1 at 1 and 3 yr. CONCLUSIONS: NBL divers initially belong to a select group with larger than predicted lung volumes. Regular diving with nitrox at shallow depths over a 3-yr period did not impair pulmonary function. Improvements in FVC and FEV1 were primarily due to a training effect.

Non-programmatic↗

Unsafe acts and unsafe outcomes in aircraft maintenance

Road safety studies using the Driver Behaviour Questionnaire (DBQ) have provided support for a three-way distinction between violations, skill-based errors and mistakes, and have indicated that a tendency to commit driving violations is associated with an increased risk of accident involvement. The aims of this study were to examine whether the three-way distinction of unsafe acts is applicable in the context of aircraft maintenance, and whether involvement in maintenance safety occurrences can be predicted on the basis of self-reported unsafe acts. A Maintenance Behaviour Questionnaire (MBQ) was developed to explore patterns of unsafe acts committed by aircraft maintenance mechanics. The MBQ was completed anonymously by over 1300 Australian aviation mechanics, who also provided information on their involvement in workplace accidents and incidents. Four factors were identified: routine violations, skill-based errors, mistakes and exceptional violations. Violations and mistakes were related significantly to the occurrence of incidents that jeopardized the quality of aircraft maintenance, but were not related to workplace injuries. Skill-based errors, while not related to work quality incidents, were related to workplace injuries. The results are consistent with the three-way typology of unsafe acts described by Reason et al. (1990) and with the DBQ research indicating an association between self-reported violations and accidents. The current findings suggest that interventions addressed at maintenance quality incidents should take into account the role of violations and mistakes, and the factors that promote them. In contrast, interventions directed at reducing workplace injury are likely to require a focus on skill-based errors.

Maintenance/manpower/methods↗

Lamb wave characterization of the effects of long-term thermal-mechanical aging on composite stiffness

Lamb waves offer a promising method of evaluating damage in composite materials. The Lamb wave velocity is directly related to the material parameters, so an effective tool exists to monitor damage in composites by measuring the velocity of these waves. The Lamb Wave Imager (LWI) uses a pulse/receive technique that excites an antisymmetric Lamb mode and measures the time-of-flight over a wide frequency range. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. In this study, the time-of-flight as well as the elastic stiffnesses D11, D22, A44, and A55 for composite samples which have undergone combined thermal and mechanical aging are obtained. The samples examined include a baseline specimen with 0 cycles, specimens which have been aged 2350 and 3530 cycles at high strain levels, and one specimen aged 3530 cycles at low strain levels.

Aircraft↗

Characterization of Alloy 709 Commercial Heats

The creep-resistant austenitic stainless steel Alloy 709 (Fe-20Cr-25Ni (wt%) based steel) is being investigated as a candidate structural material for the next generation of advanced reactors. Unlike conventional solid solution strengthened austenitic stainless steels, Alloy 709 develops a variety of precipitates during aging at different temperatures and times. In this study, precipitate evolution during short-term aging at 775°C was characterized. The effect of aging time (e.g., 10 vs. 100 hours) and cooling after aging (e.g., water quench vs. air cool) on grain size and precipitates have been investigated using light optical microscopy (OM), electron backscatter diffraction (EBSD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDS). MX (Ni,Tb)(C,N) and M23C6 (Cr,Mo)C precipitates were observed in all the statically-aged samples. The grain size distribution in the sample aged for 10 hours and water quenched (10Q) versus the one aged for 100 hours and air cooled (100A) were comparable. This indicates that grain structure was fairly stable when aging at 775°C for up to 100 hours. In contrast, the sample aged for 10 hours and air cooled (10A) showed the smallest and the most uniform grain size distribution. This phenomenon was observed in only one sample. More studies on duplicate samples are needed to confirm the results obtained. The cooling medium (e.g., water quench vs. air cool) was not observed to impact the size nor the distribution of the MX and M23C6 precipitates. Increasing the aging time resulted in the following: (1) a decrease in dislocations as well as the number density of small precipitates; (2) an increase in the ratio of free precipitates that were not pinning dislocations; (3) relatively higher N, Nb, and Ti concentration in MX precipitate; (4) some increase in length of M23C6 carbides which were located on the coherent boundaries; and (5) the introduction of Sienriched M6X precipitates. The tensile tests at room temperature showed similar properties for each of the static aging treatments, indicating that the differences observed in the microstructural analysis did not have a significant impact on the tensile properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗