Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The Spartan attitude control system - Control electronics assembly

The Spartan attitude control system (ACS) represents an evolutionary development of the previous STRAP-5 ACS through the use of state-of-the-art microprocessors and hardware. Despite a gyro rate signal noise problem that caused the early depletion of argon gas, the Spartan 101 experiment was able to collect several hours of data from two targets. Attention is presently given to the ACS sequencer module, sensor interface box, valve driver box, control electronics software, jam tables, and sequencer programs.

Stone, R. W.↗

The Spartan attitude control system - Ground support computer

The Spartan Attitude Control System (ACS) contains a command and control computer. This computer is optimized for the activities of the flight and contains very little human interface hardware and software. The computer system provides the technicians testing of Spartan ACS with a convenient command-oriented interface to the flight ACS computer. The system also decodes and time tags data automatically sent out by the flight computer as key events occur. The duration and magnitude of all system maneuvers is also derived and displayed by this system. The Ground Support Computer is also the primary Ground Support Equipment for the flight sequencer which controls all payload maneuvers, and long term program timing.

Schnurr, R. G., Jr.↗

The mission configuration process for the Spartan attitude control system

The Spartan attitude control system (ACS) control electronics assembly cold plate has a standard connector interface to the rest of the Spartan payload and ground equipment. The connectors carry gyro signals, optical sensor signals, the experiment interface, the gas command decoder interface, and a pneumatics interface. Different flights can employ different optical sensor complements; the ACS engineer must accordingly connect the sensor error signals to the proper pins and connectors on the ACS electronics.

Stone, R. W.↗

Image data compression with vector quantization in the transform domain

In this paper, an algorithm is presented for image data compression based upon vector quantization of the two-dimensional discrete cosine transformed coefficients. The ac energies of the transformed blocks are used to classify them into eight different ac classes. The ac coefficients of the transformed blocks of class one are set to zero, while those of classes two through eight are transmitted by seven different code books. The dc coefficients of all eight classes are scalar quantized by an adaptive uniform quantizer. As a result, only 4.5 bits instead of eight bits are required to transmit the dc coefficient with negligible additional degradation. Overall, this algorithm requires approximately 0.75 bits per pixel and gives an average reconstruction error of 7.1.

Abdelwahab, A. A.↗

Attitude Control Working Group report

The goals were to establish the Attitude Control System (ACS) requirements, constraints, technology assessment, technology shortfalls, expected in the year 2000. These were based upon all missions, military and civil, for LEO and GEO. The critical ACS technology issues were identified and ACS programs developed to address these critical issues.

Reid, Daniel F.↗

Evaluation, development, and characterization of superconducting materials for space application

Results are reported of low magnetic field studies of dc magnetic susceptibility and ac magnetic susceptibility of bulk samples and powders. These data are analyzed and compared with the microstructures and compositions of the samples as determined by scanning electron microscopic micrographs, X-ray and chemical analysis. Particular emphasis is given to the interpretation of the ac magnetic susceptibility data which were obtained as function of the magnitude and frequency of the ac measuring field, and low values of an applied dc magnetic field. Two general conclusions are given and briefly discussed.

Thorpe, A. N.↗

A signal filter with zero phase lag

Rotorcraft and rotorcraft models are tested at the NASA Ames National Full-Scale Aerodynamics Complex (NFAC). The models tested in the NFAC wind tunnels are controlled by a remote control console located in a control room. Certain critical information must be displayed on the control console to monitor the rotor to insure that the rotor is within operational limits. The signal for these parameters is complex (with ac and dc components) and is derived from pitch and flapping transducers on the rotor head. The pitch and flapping cyclics are derived from resolver circuits that indicate the magnitude and phase of the cyclics. Conventional filter circuits used to separate the ac and dc components have a phase lag on the ac component, which will introduce an error in the cyclic vector. To overcome this error, a filter with zero phase lag needed to be developed. This paper discusses a rotorcraft circuit that was designed to have an ac/dc filter with zero phase lag over the frequency range.

Forsyth, T. J.↗

A comparative study of electric power distribution systems for spacecraft

The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems.

Stuart, Thomas A.↗

Superconductivity in 2-2-3 Y2Ba2Cu3O(sub 8+ delta)

Researchers synthesized a new high T(sub c) 2-2-3 superconductor (Y2Ba2Cu3O8+delta) by a special preparation technique and characterized it by ac-susceptibility measurements. Diamagnetism and Meissner effect sets in at low fields and superconducting transition onsets at 90 K. The systematic investigation of the real and imaginary components of ac-susceptibility as a function of temperature and applied ac magnetic field reveals that the magnetic behavior is that of a granular type superconductor.

Joshi, H. H.↗

The low magnetic field properties of superconducting bulk yttrium barium copper oxide - Sintered versus partially melted material

A comparison of the low magnetic field properties of sintered (990 C) and partially melted samples (1050 C) has been performed. Changes in the microstructure produced by recrystallization from the melt result in a significant increase in flux pinning at 77 K. Low-frequency (10-100 Hz), low-ac magnetic-field (0.01-9.0 Oe) ac susceptibility data show that gross changes in the loss component accompany the observed changes in microstructure. The effects of applied dc magnetic fields (10-220 Oe) on the ac responses of these microstructures have also been probed.

Hein, R. A.↗

20 kHz main inverter unit

A proof-of-concept main inverter unit has demonstrated the operation of a pulse-width-modulated parallel resonant power stage topology as a 20-kHz ac power source driver, showing simple output regulation, parallel operation, power sharing and short-circuit operation. The use of a two-stage dc input filter controls the electromagnetic compatibility (EMC) characteristics of the dc power bus, and the use of an ac harmonic trap controls the EMC characteristics of the 20-kHz ac power bus.

Hussey, S.↗

Propulsion system filter sizing considerations for the Galileo spacecraft

Filtration capacity of the Galileo propulsion system has been investigated. Ground testing of flight spare components has been conducted to determine the representative number and size distribution of particulate matter collected in flow tests. For these tests and for filter qualification tests, a number of effects were examined. The influence of gravitational particle settling on ground test results vs the flight environment was considered. Centrifugal effects inherent in the test apparatus and/or the propulsion system could have an influence. Variability among particle sizing techniques was explored. The influence of size distribution, particle shape, and density in the choice of a particulate test material was studied. Characteristics for AC Coarse Dust (an industry standard filter test media), microscopic polymer beads, and aluminum oxide particulate test matter are listed. Filtration tests were conducted using AC Coarse Dust and mixtures containing components of AC Coarse Dust. These results are expected to be useful data for filter sizing of future spacecraft.

Jan, Darrell L.↗

VUV-visible measurements on different samples of amorphous carbon

Among various candidate materials for interstellar dust, amorphous carbon (AC) is playing an increasingly important role (Greenstein, 1981; Hecht et al., 1984; Jura, 1983, 1986). Furthermore, recent in situ measurements have clearly shown the presence of carbonaceous grains in the coma of comet Halley (Kissel et al., 1986). Laboratory investigations on AC grains may be very useful to better interpret observations and to support theoretical elaborations. Recently, the authors started an international research program which also includes UV extinction analyses on AC samples, by using synchrotron light. Preliminary results obtained in a first shift of measurements, last June, are given. At the present stage of the data analysis, the authors can only draw some preliminary considerations. A wide band falling at around 240 nm is detected in all the analyzed samples. It intensity seems to decrease with increasing the dust collecting distance. A peak at 150 nm decreases in intensity with increasing the collecting distance. The band seems absent in the samples characterized by a larger amount of dust. A feature at about 200 nm is detected in some samples. At the moment the authors tend to attribute it to the transmission properties of the LiF substrates at the wavelength and/or to some problems in the experimental setup. It is unclear if a hump at 120 nm is real or due to instrumental effects. The profile of the spectra does not show substantial changes when the samples are cooled down to about 100 K. The present results appear to be in general agreement with previous findings, but their analysis is in progress and the interpretation is still on the way.

Blanco, A.↗

A new probe for measuring small electric fields in plasmas

A dipolar double probe has been developed for in situ measurements of small electric fields in laboratory plasmas. The probe measures dc to ac electric fields (f values between 0 and 20 MHz) with high sensitivity (Emin about 10 microV/cm) and responds to both space charge electric fields and inductive electric fields. Using voltage-to-frequency conversion, the probe signal is obtained free of errors and loading effects by a transmission line. Various examples of useful applications for the new probe are presented, such as measurements of dc ambipolar fields, ac space-charge fields of ion acoustic waves, ac inductive fields of whistler waves, and mixed inductive and space-charge electric fields in current-carrying magnetoplasmas.

Stenzel, R. L.↗

Thermal and mechanical damping of solar p-modes

Nonadiabatic effects associated with the transfer of energy and with turbulent stresses add small imaginary parts, omega-i(1) and omega-i(2), to solar p-mode eigenfrequencies. Numerical calculations have shown that these quite different processes make comparable contributions to omega-i at frequencies well below the acoustic cutoff at omega-ac. Analytic expressions are derived which reveal the connection between omega-i(1) and omega-i(2). The estimates yield omega-i proportional to omega exp 8 for omega much less than omega-ac in good agreement with the numerical calculations. However, the observed line width is proportional to omega exp 4.2 at low frequencies. It is suspected that there is an unmodeled component of perturbed convective energy transport or of turbulent viscosity that makes an important contribution to omega-i at omega much less than omega-ac.

Goldreich, Peter↗

Superconductivity in 2-2-3 system Y2Ba2Cu2O(8+delta)

Researchers synthesized a new high T(sub c) 2-2-3 superconductor Y2Ba2Cu3O(8+delta) by a special preparation technique and characterized it by ac-susceptibility measurements. Diamagnetism and Meissner effect sets in at low fields and superconducting transition onsets at 90 K. The systematic investigation of the real and imaginary components of ac-susceptibility as a function of temperature and applied ac magnetic field reveals that the magnetic behavior is that of a granular type superconductor.

Joshi, H. H.↗

Modelling a single phase voltage controlled rectifier using Laplace transforms

The development of a 20 kHz, AC power system by NASA for large space projects has spurred a need to develop models for the equipment which will be used on these single phase systems. To date, models for the AC source (i.e., inverters) have been developed. It is the intent of this paper to develop a method to model the single phase voltage controlled rectifiers which will be attached to the AC power grid as an interface for connected loads. A modified version of EPRI's HARMFLO program is used as the shell for these models. The results obtained from the model developed in this paper are quite adequate for the analysis of problems such as voltage resonance. The unique technique presented in this paper uses the Laplace transforms to determine the harmonic content of the load current of the rectifier rather than a curve fitting technique. Laplace transforms yield the coefficient of the differential equations which model the line current to the rectifier directly.

Kraft, L. Alan↗

Gibbs free-energy difference between the glass and crystalline phases of a Ni-Zr alloy

The heats of eutectic melting and devitrification, and the specific heats of the crystalline, glass, and liquid phases have been measured for a Ni24Zr76 alloy. The data are used to calculate the Gibbs free-energy difference, Delta G(AC), between the real glass and the crystal on an assumption that the liquid-glass transition is second order. The result shows that Delta G(AC) continuously increases as the temperature decreases in contrast to the ideal glass case where Delta G(AC) is assumed to be independent of temperature.

Ohsaka, K.↗